首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 688 毫秒
1.
We describe an application of capillary zone electrophoresis (CZE) with transient isotachophoresis (ITP) as the on-line concentration procedure for the determination of iodide in seawater. The effective mobility of iodide was decreased by the addition of 10 mM cetyltrimethylammonium chloride (CTAC) to an artificial seawater background electrolyte (BGE) so that transient ITP functioned and iodide was separated from other coexisting anions such as bromide, nitrite, and nitrate in seawater samples. After sample injection, 600 mM acetate was separately injected into the capillary as the terminating ion to generate transient ITP. The limit of detection (LOD) for iodide was 3.0 microg/L. The LOD was obtained at a signal-to-noise ratio (S/N) of 3. The values of the relative standard deviation (RSD) of peak area, peak height, and migration time for iodide were 2.9, 2.1, and 0.6%. The proposed method was applied to the determination of iodide in seawater collected around the Osaka Bay. The results obtained by use of the calibration graph were agreed with those obtained by the addition of the standard solutions for iodide.  相似文献   

2.
We describe a combination of selected ions as a terminating ion which is useful for transient isotachophoresis (ITP) in capillary zone electrophoresis (CZE) for the determination of nitrite and nitrate in seawater. In addition to 150 mM sulfate as the principal terminating ion, 10 mM bromate was added to a sample solution as the additional terminating ion. Artificial seawater containing 3 mM cetyltrimethylammonium chloride (CTAC) was adopted as a background electrolyte (BGE). The limits of detection (LODs) for nitrite and nitrate were 2.2 and 1.0 microg/L (as nitrogen), respectively. The LODs were obtained at a signal to noise ratio (S/N) of 3. The values of the relative standard deviation (RSD) of peak area for these ions were 1.9 and 1.4%. The RSDs of peak height were 1.7 and 1.9%, the RSDs of migration time 0.11%. The proposed method was applied to the determination of nitrite and nitrate in a proposed certified reference material for nutrients in seawater, MOOS-1, distributed by the National Research Council of Canada (NRC). The results almost agreed with the assigned tolerance interval.  相似文献   

3.
We describe capillary zone electrophoresis (CZE) with transient isotachophoresis (ITP) for the determination of low concentrations of nitrite and nitrate ions in seawater. Bromide-free artificial seawater was adopted as background electrolyte (BGE) to eliminate the interference of high concentrations of salts in seawater. To reverse the electroosmotic flow (EOF), 3 mM cetyltrimethylammonium chloride (CTAC) was added to the BGE. High concentrations of chlorate were added to sample solutions as the terminating ion to generate the ITP process before the CZE separation. In general, the stacking effect increased with increasing amounts of chlorate injected into the capillary. The limits of detection (LODs) for nitrite and nitrate were 0.063 and 0.033 mg/L when the chlorate concentration was 600 and 200 mM, respectively; these were half of those obtained by CZE without the transient ITP. The LODs were obtained at a signal to noise ratio (S/N) of 3. The relative standard deviations (RSD, n = 10) of the peak areas for these ions were 3.2 and 2.9%. The RSDs of peak heights for these ions were 1.6 and 2.1%. The RSDs of migration times for these ions were 0.67 and 0.46%.  相似文献   

4.
We describe capillary zone electrophoresis (CZE) for the simultaneous determination of bromide, nitrite and nitrate ions in seawater. Artificial seawater was adopted as the carrier solution to eliminate the interference of high concentrations of salts in seawater. The artificial seawater was free from bromide ion to enable the determination of bromide ion in a sample solution. For the purpose of reversing the electroosmotic flow (EOF), 3 mM cetyltrimethylammonium chloride (CTAC) was added to the carrier solution. A 100 microm ID (inside diameter) capillary was used to extend the optical path length. The limits of detection (LODs) for bromide, nitrite, and nitrate ions were 0.46, 0.072, and 0.042 mg/L (as nitrogen), respectively. The LODs were obtained at a signal to noise ratio (S/N) of 3. The values of the relative standard deviation (RSD) of peak area for these ions were 1.1, 1.5, and 0.97%. The RSDs of migration time for these ions were 0.61, 0.69, and 0.66%. Artificial seawater samples containing various concentrations of bromide, nitrite, and nitrate ions were analyzed by the method. The error was less than +/-12% even if the concentration ratio of bromide ion to nitrite or nitrate ion was 20-240. The proposed method was applied to the determination of bromide, nitrite, and nitrate ions in seawater samples taken from the surface and the seabed. These ions in other environmental waters such as river water and rainwater samples were also determined by ion chromatography (IC) as well as this method.  相似文献   

5.
We developed CZE with indirect UV detection for the determination of phosphate in seawater using transient ITP as an on-line concentration procedure. The following optimum conditions were established: BGE, 5 mM 2,6-pyridinedicarboxylic acid (PDC) containing 0.01% hydroxypropylmethylcellulose (HPMC) adjusted to pH 3.5; detection wavelength, 200 nm; vacuum injection period of sample, 3 s (45 nL); terminating ion solution, 500 mM MES adjusted to pH 4.0; vacuum injection period of the terminating ion solution, 30 s (450 nL); applied voltage, 30 kV with the sample inlet side as the cathode. The LOD for phosphate was 16 microg/L (PO(3-)(4) -P) at S/N of 3. The respective values of the RSD of the peak area, peak height, and migration time for phosphate were 2.6, 2.3, and 0.34%. The proposed method was applied to the determination of phosphate in a seawater certified reference material for nutrients, MOOS-1, distributed by the National Research Council of Canada (NRC). The results were very similar to certified values. The method was also applied to the determination of phosphate in coastal seawaters. The results agreed with those obtained using a conventional spectrophotometric method.  相似文献   

6.
Transient isotachophoresis-capillary zone electrophoresis with artificial seawater as the background electrolyte (BGE) was improved to further lower the limit of detection (LOD) for determination of nitrite and nitrate in seawater. By lowering the pH of BGE, the difference between effective mobility of nitrite and that of nitrate increased, thereby permitting increased sample volumes to be tolerated and their LOD values to decrease. Artificial seawater with pH adjusted to 3.0 using phosphate buffer was adopted as the BGE. To reverse electroosmotic flow (EOF), a capillary was flushed with 0.1 mM dilauryldimethylammonium bromide for 3 min before the capillary was filled with the BGE. Limits of detection (LODs) for nitrite and nitrate were 2.7 and 3.0 microg/l (as nitrogen), respectively. The LODs were obtained at a signal-to-noise ratio of 3. Values of the relative standard deviation (RSD) of peak area for these ions were 2.0 and 0.75%, respectively, when nitrite concentration was 0.05 mg/l and that of nitrate was 0.5 mg/l. The RSDs of peak height were 4.4 and 2.3%. The RSD values of migration time for these ions were 0.19 and 0.17%. The proposed method was applied to determination of nitrite and nitrate in a proposed certified reference material for nutrients in seawater, MOOS-1, distributed by the National Research Council of Canada. Results agreed with the assigned tolerance interval. This method was also applied to determination of these ions in seawater collected around Osaka Bay. Results nearly agreed with those obtained by a conventional spectrophotometric method.  相似文献   

7.
毛细管离子电泳法同时测定腌菜中硝酸根和亚硝酸根   总被引:3,自引:0,他引:3  
以溴离子(Br-)为内标,建立了毛细管离子电泳同时测定腌菜中的硝酸根和亚硝酸根的方法。讨论了缓冲液pH、样品和缓冲液中氯化钠浓度、分离电压对分离的影响。结果表明:以含1mol LNaCl的40mmol LH3PO4 NaOH缓冲-、-得到基线分离。NO3-和NO2液(pH3.5)为背景电解质,4min内Br-、NO3-检出限分别为0.1g L和0.3g L,峰面积相对标准偏差分别为4.6%和NO25 8%。  相似文献   

8.
We developed capillary zone electrophoresis with transient isotachophoresis (ITP) as an on-line concentration procedure for simultaneous determination of iodide and iodate in seawater. The effective mobility of iodide was decreased by addition of 20 mM cetyltrimethylammonium chloride to an artificial seawater background electrolyte so that transient ITP functioned for both iodide and iodate. Limits of detection for iodide and iodate were 4.0 and 5.0 microg/l (as iodine) at a signal-to-noise ratio of 3. Values of the relative standard deviation of peak area, peak height, and migration times for iodide and iodate were 2.9, 1.3, 1.0 and 2.3, 2.1, 1.0%, respectively. The proposed method was applied to simultaneous determination of iodide and iodate in seawater collected at a pond at our university.  相似文献   

9.
An on-line preconcentration capillary electrophoresis (CE) technique, which combines a large volume sample stacking with a dynamic pH junction technique, is introduced in this paper. This dynamic pH junction with co-electroosmotic migration is formed between sodium borate pH 9.5 and sodium phosphate pH 2.5 with 150 mM sodium dodecylsulfate (SDS). A full capillary based injection allows determination of weak acidic compounds at ppb concentration levels (achieved LOD for benzoic acid was 11 nmol L(-1)). The proposed preconcentration method was compared with ITP/ITP (LOD 120 nmol L(-1)), ITP/CZE (LOD 740 nmol L(-1)) and a simple CZE method (LOD 23,330 nmol L(-1)). The analytical potential of this method was assessed with juice test samples.  相似文献   

10.
A capillary zone electrophoresis (CZE) method was established to determine low concentration nitrate which was online preconcentrated with chloride-induced leading-type sample self-stacking for seawater samples. The sample self-stacking was based on transient isotachophoresis in which chloride served as leading ion, and dihydrogenphosphate in the background electrolyte (0.1 M phosphate) as the terminating one. Due to the small mobility difference between nitrate and chloride, the isotachophoresis time was so long that nitrate could not separate from the rear sharp boundary between chloride and the background electrolyte (BGE) when it migrated to the detection window. A zwitterionic surfactant, 3-(N,N-dimethyldodecylammonio)propane sulfonate was added to the BGE to enlarge the mobility difference for its selective interaction with anions. Thus, a highly conductive sample could be injected in a large volume with about fourfold sensitivity enhancement compared to that of field amplification sample stacking in which nitrate was dissolved in pure water. The relative standard deviations (n=5) of migration time, peak area, peak height were 0.1, 3.0, 1.5%, respectively. The limit of detection (S/N=3) for nitrate was 35 microg/l in seawater samples with relatively low concentration BGE (0.1 M sodium phosphate, pH 6.2). The overall procedure consisting of online preconcentration and separation was as simple as routine CZE except for a slightly longer sample injection time (3-4 min).  相似文献   

11.
An ion-chromatographic (IC) system with high selectivity for separation of nitrite is described. It is analogous to the EIC (electrostatic IC) previously reported and was established using 3-(N,N-dimethylstearylammonio)propanesulfonate (C23H49NO3S, a sulfobetaine type of zwitterionic surfactants) as the stationary phase and dilute aqueous HCl solutions as the mobile phase. Five inorganic anions, sulfate, chloride, bromide, nitrate, and nitrite were chosen as the model analytes and were analyzed using this EIC system. Sulfate was always eluted first, followed by chloride, bromide and nitrate. Nitrite, however, could be eluted either before or after nitrate, depending on the concentration of HCl in the eluent. An elution order nitrate< nitrite was always obtained simply by using >3 mmol L(-1) HCl as the eluent. For nitrite the detection limit was better than 2.1 x 10(-7) mol L(-1) (100 microL sample injection volume, S/N=3, UV at 210 nm). Bromide and nitrate could also be separated under these HPLC conditions. The detection limit for bromide was 7.2 x 10(-8) mol L(-1) and for nitrate 6.5 x 10(-8) mol L(-1). Both nitrite and nitrate in real seawater samples were successfully determined with direct sample injection using this EIC system.  相似文献   

12.
基于苯胺与亚硝酸盐的重氮化反应及反应产物与甲萘酚的显色,借助流动分析技术,实现了海水中苯胺含量的分析测定。体系以30.9g/L的NaCl做载液、人工海水配制标准样品,对各个影响因素进行了优化。苯胺浓度在0.01~1.0mg/L范围内与相对峰高呈线性关系,线性方程ΔH(mV)=200.53ρ+1.0728(n=8,ρ为苯胺浓度mg/L),相关系数R2=0.9982。方法的检出限(3σ)为0.005mg/L,相对标准偏差(RSD)为4.8%(n=11)。考察了共存离子、不同盐度样品对分析测定的影响。用于实际海水样品的分析,回收率为95.8%~106.6%。  相似文献   

13.
A method has been developed for the determination of iodide in mineral water, seawater, cooking salt, serum, and urine based on hyphenation of capillary ITP and zone electrophoresis. A commercially available instrumentation for capillary ITP with column-switching system was used. ITP served for removal of chloride present in the analyzed samples in a ratio of 10(6)-10(7):1 to iodide, zone electrophoresis was used for evaluation. Isotachophoretic separation proceeded in a capillary made of fluorinated ethylene-propylene copolymer of 0.8 mm id and 90 mm total length to the bifurcation point filled with a leading electrolyte (LE) composed of 8 mM HCl + 16 mM beta-alanine (beta-Ala) + 10% PVP + 2.86 mM N(2)H(4)x2HCl, pH 3.2; and a terminating electrolyte composed of 8 mM H(3)PO(4) + 16 mM beta-Ala + 10% PVP + 5 mM N(2)H(4), pH 3.85 for all the matrices except seawater. For ITP of seawater the LE consisted of 50 mM HCl + 100 mM beta-Ala + 10% PVP + 2.86 mM N(2)H(4)x2HCl, pH 3.52. Distance of conductivity detector from the injection point and bifurcation point was 52 and 38 mm, respectively. Zone electrophoresis was performed in a capillary made of fused silica of 0.3 mm id and 160 mm total length filled with LE from isotachophoretic step. LODs reached for all matrices were 2-3x10(-8) M concentration (2.5-4 microg/L) enabled monitoring of iodide in all analyzed samples with RSD 0.4-9.3%. Estimated concentrations of iodide in individual matrices were 10(-6)-10(-8) M.  相似文献   

14.
A fast and highly sensitive ion chromatographic method using monolithic ODS columns was developed for the determination of nitrite (NO2-) and nitrate (NO3-) in seawater. Two monolithic ODS columns (50 mm x 4.6 mm i.d. + 100 mm x 4.6 mm i.d.) connected in series were coated and equilibrated with 5 mM cetyltrimethylammonium chloride (CTAC) aqueous solution. The column efficiency with 0.5 M NaCl as the mobile phase did not decrease in spite of the increase in flow rate of the mobile phase. Thus, good chromatograms were obtained within 3 minutes for NO2- and NO3 in artificial seawater without interferences by coexisting ions. The detection limit (S/N = 3) with UV detection at 225 nm was 0.8 and 1.6 microg/L for NO2- and NO3-, respectively. The characteristics of the monolithic CTA(+)-coated ODS columns were discussed. The present method was successfully applied to the fast and sensitive determination of NO2- and NO3- in real seawater samples.  相似文献   

15.
A rapid and simple capillary electrophoretic method was developed for the direct determination of bromide ion in seawater. We have found an effective method, based on the use of polyethyleneimine-coated capillaries and the addition of sodium chloride to the background electrolyte. The use of coated capillaries with a cationic polymer changes the direction of the electroosmotic flow in the capillary, which favors the migration speed of the bromide ion and enables the use of low salt concentrations in the separation electrolyte. Bromide ion in seawater can be determined within 2 min using this system and 20 mmol L-1 NaCl-containing separation electrolyte. The detection limit for the bromide ion was 0.45 g ml-1. The method was applied to the determination of bromide ion in seawater samples collected from the Bosphorus and the Black Sea. Bromide contents in samples from 0 to 72 m depths varied between 33.2 and 72.8 mg L-1 with a mean 3.0% RSD.  相似文献   

16.
A novel, simple and highly sensitive CE method was developed to determine total iodine (TI) in seawater. The method is based on the on-capillary reduction of iodine species to iodide by a reductant, introduced into the capillary before sample injection, the preconcentration of iodide using isotachophoresis, followed by its UV detection. Under optimized conditions for reduction and CE separation, the limit of detection for TI (S/N = 3) reached 0.4 microg L(-1) (226 nm). The repeatability of migration time and peak area, expressed by relative standard deviation, was 0.46 and 1.45%, respectively (n = 19). The correlation factor was 0.9991 (n = 10) for the concentration range of 12-115 microg I L(-1). The CE results obtained for the real seawater analysis agreed with the data of ion chromatography. To determine the genuine TI by the proposed method, organic iodinated compounds in the sample were treated with H202 and irradiation with UV light before analysis.  相似文献   

17.
In this study, a capillary electrophoresis (CE) methodology for the determination of free glycerol in biodiesel using oxidative cleavage with periodate was optimized and validated. The amount of iodate produced in the reaction was determined by CE. The optimized electrolyte was 20 mmol L(-1) glycine and 10 mmol L(-1) trifluoroacetic acid (direct UV detection, 210 nm). The short total analysis time (less than 28 s) was obtained using the short end injection mode. The optimization of the method was carried out using Peakmaster software. The choice of the components of the run electrolyte and of the internal standard (nitrate) was made through the use of effective mobility curves. A good correlation coefficient higher than 0.9991 and low LOD 4.3 mg L(-1) was obtained. The recovery of free glycerol was 95.4-102.4%. This method was used to determine glycerol in commercial biodiesel samples.  相似文献   

18.
A simple, fast, inexpensive and reliable capillary zone electrophoresis (CZE) method for the determination of econazole nitrate in cream formulations has been developed and validated. Optimum conditions comprised a pH 2.5 phosphate buffer at 20 mmol L(-1) concentration, +30 kV applied voltage in a 31.5 cm x 50 microm I.D. capillary. Direct UV detection at 200 nm led to an adequate sensitivity without interference from sample excipients. A single extraction step of the cream sample in hydrochloric acid was performed prior to injection. Imidazole (100 microg mL(-1)) was used as internal standard. Econazole nitrate migrates in approximately 1.2 min. The analytical curve presented a coefficient of correlation of 0.9995. Detection and quantitation limits were 1.85 and 5.62 microg mL(-1), respectively. Excellent accuracy and precision were obtained. Recoveries varied from 98.1 to 102.5% and intra- and inter-day precisions, calculated as relative standard deviation (RSD), were better than 2.0%. The proposed CZE method presented advantageous performance characteristics and it can be considered suitable for the quality control of econazole nitrate cream formulations.  相似文献   

19.
In the present study, field amplified sample stacking (FASS) techniques in the nonaqueous capillary electrophoresis method (NACE) were introduced for the on-line concentration of the acrylamide to improve acrylamide detection at 210 nm by diode-array detection. Acetonitrile (ACN) as a nonaqueous solvent permits acrylamide to be protonated through the change of its acid-base chemistry, allowing capillary electrophoretic separation of this compound. Choosing 30 mmol L(-1) HClO(4), 20 mmol L(-1) NaClO(4), 218 mmol L(-1) CH(3)COOH in ACN as the separation electrolyte and employing sample stacking methods, the LOD value of acrylamide was decreased to 2.6 ng mL(-1) with electrokinetic injection and 4.4 ng mL(-1) with hydrodynamic injection. Optimized stacking conditions were applied to the determination of acrylamide in several foodstuffs. The method is simple, rapid, inexpensive, and widely applicable for the determination of acrylamide in food samples.  相似文献   

20.
A new method for the determination of trace glyphosate (GLYP), non-selective pesticide, by CZE with online ITP pre-treatment of drinking waters on a column-coupling (CC) chip has been developed. CC chip was equipped with two injection channels of 0.9 and 9.9 μL volumes, two separation channels of 9.3 μL total volume and a pair of conductivity detectors. A very effective ITP sample clean-up performed in the first channel at low pH (3.2) was introduced for quick CZE resolution and detection of GLYP carried out at higher pH (6.1) in the second channel on the CC chip. The LOD for GLYP was estimated at 2.5 μg/L (15 nmol/L) using a 9.9 |mL volume of the injection channel. ITP-CZE analyses of model and real samples have provided very favorable intra-day (0.1-1.2% RSD) and inter-day (2.9% RSD) repeatabilities of the migration time for GLYP while 0.2-6.9% RSD values were typical for the peak area data. Recoveries of GLYP in spiked drinking water varied in the range of 99-109%. A minimum pre-treatment of drinking water (degassing and dilution) and a short analysis time (ca. 10 min) were distinctive features of ITP-CZE determinations of GLYP on the CC chip with high sample volume loaded, as well.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号