首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 109 毫秒
1.
采用氟化铵-盐酸-硝酸-硫酸分解样品,氨水沉淀分离铁、锰、铅等共存元素,滤液中加入掩蔽剂掩蔽少量干扰元素,在pH=5~6的乙酸-乙酸钠缓冲溶液中,以二甲酚橙为指示剂,用EDTA标准滴定溶液滴定。测得结果为锌、镉合量,扣除镉量,即为锌量。方法用于测定再生锌原料中锌,结果的相对标准偏差(RSD,n=11)为0.15%~1.0%。按照实验方法对再生锌原料样品进行加标回收实验,回收率为99.1%~102%。能满足日常对再生锌原料中锌含量的检测要求。  相似文献   

2.
建立了测定粗锌中镉的火焰原子吸收光谱法。粗锌样品经硝酸溶液(1+1)溶解,以体积分数约为5%的硝酸溶液为测定介质,使用空气–乙炔火焰,以水调零,选定228.8 nm为测定波长。干扰试验表明,锌的基体和其它杂质元素均不干扰镉的测定。在选定的仪器条件下,镉在0.20~3.00μg/mL范围内与其对应的吸光度呈良好的线性关系,相关系数为0.999 6,方法检出限为0.02μg/mL。镉的加标回收率为98%~101%,测定结果的相对标准偏差为0.70%~2.70%(n=7)。该法准确可靠,灵敏度高,干扰少,重现性好,适用于镉含量在0.001 0%~2.00%之间的粗锌中镉的测定。  相似文献   

3.
建立了电感耦合等离子体原子发射光谱(ICP-AES)法测定铜冶炼烟尘中锌含量的分析方法。针对样品中碳、硅含量高的特点,有针对性地研究了样品的消解方法,确定采用盐酸、硝酸、氢氟酸、高氯酸对铜冶炼烟尘样品进行消解。同时进行了干扰实验,确定样品中高含量的铜、铅、砷等对样品测定结果没有影响。并对仪器的工作参数进行了优化。方法检出限为0.011mg/L,测定下限为0.019mg/L,3个样品的相对标准偏差在0.54%~0.92%,加标回收率在96.0%~101%。样品消解完全,流程短,操作简单,快速,测定准确度高,可以满足铜冶炼烟尘中锌含量的测定。  相似文献   

4.
目的测定耳草中4种金属元素含量。方法采用微波消解-原子荧光光谱法测定了中药材耳草中砷、汞、硒、镉的含量。结果在最佳实验条件下,砷、汞、硒、镉的检出限分别为0.305、0.016、0.082、0.039 ng/mL,样品中4种元素的加标回收率在97.2%~105.4%之间。结论该法快速、准确、简便且准确度高,为中药材中重金属含量的测定提供了较好的方法。  相似文献   

5.
采用微波消解系统对某电镀污泥进行消解,利用ICP-MS对污泥中的重金属进行测定。称取制备后样品,置于消解罐中充分反应后,赶酸、定容后利用电感耦合等离子体质谱法进行测定。电镀污泥中的铬为18845.2mg/kg、镉为10.3mg/kg、镍为5200.0mg/kg、铅为189.7mg/kg、铜为3271.7mg/kg、锌为49632.6mg/kg。测定结果表明所检测项目工作曲线线性关系好,相关系数r均大于0.999。铬加标回收率在91.6~97.7%之间、镉加标回收率在92.0~97.0%之间、镍加标回收率在95.1~98.0%之间、铅加标回收率在94.3~95.2%之间、铜加标回收率在97.1~102%之间、锌加标回收率在96.3~98.7%之间,均满足相关测定要求。计算的潜在生态危害系数、潜在生态危害指数结果表明,电镀污泥中的铬、镉、铅、铜、锌为轻微生态危害,镍为强生态危害;潜在生态危害指数RI计算值为216.69,属于中等生态危害。  相似文献   

6.
建立极谱法同时测定海水中铜、镉、铅、锌的含量。在10.0~35.0℃条件下,试样于–1.15 V恒压下电解,富集在汞电极上生成汞齐,并随电极电位的变化而发生氧化还原反应,产生电流,通过标准加入法进行定性和定量。铜、镉、铅、锌的检出限分别为0.64,0.14,0.17,2.0μg/L,定量限分别为2.5,0.50,0.50,10.0μg/L。样品加标回收率为80.4%~106.0%,测定结果的相对标准偏差为0.43%~6.09%(n=6)。该法具有操作简便、抗干扰性能强、灵敏度高等特点,能够满足海水中铜、镉、铅、锌的监测要求。  相似文献   

7.
建立了测定粗锌中砷含量的原子荧光光谱法。粗锌样品经硝酸溶液(1+1)低温溶解完全以后,在盐酸介质中,用抗坏血酸预还原,以硫脲掩蔽铜、铁、银等杂质元素,砷被硼氢化钾还原为氢化物,用氩气导入原子化器测量。砷测定结果的相对标准偏差为1.5%~3.0%(n=11),加标回收率为98.4%~103.6%。与国家标准测定方法分光光度法测定结果对比,相对偏差为0.1%~2.4%。该法准确、可靠,适用于砷含量在0.005 0%~0.50%之间的粗锌中砷的测定。  相似文献   

8.
利用HNO3–HClO4混合酸消解样品,采用氢化物发生–原子荧光光谱法测定牡蛎中镉的含量。在优化的仪器工作条件下,镉的质量浓度在0.20~1.50μg/L范围内与荧光强度呈良好的线性关系,线性相关系数为0.9992,检出限为0.10μg/L,测定结果的相对标准偏差为4.48%(n=12),加标回收率为94.3%~106.1%。测定了标准物质贻贝GB 08571中镉的含量,测定结果与标准值一致。该方法可满足牡蛎中微量镉的分析测定。  相似文献   

9.
研究了EDTA容量法测定冰铜中含量在2%~6%锌的测定方法,其中重点讨论了冰铜中的铜、铁、铅、铝、砷、锑、镉等干扰元素对锌的测定影响及其消除方法;讨论了滴定酸度、滴定温度及陈化时间对锌的测定影响;7次测定相对标准偏差为1.1%~1.6%,加标回收率达到96.2%~104%,与原子吸收光谱法测定结果比对,满足分析要求。  相似文献   

10.
火焰原子吸收分光光度法测定路边青中重金属含量   总被引:1,自引:0,他引:1  
采用浓硝酸-高氯酸常压消解路边青样品,用火焰原子吸收分光光度法(FAAS)测定了路边青中五种重金属含量.实验结果表明:路边青样品中五种重金属元素含量大小顺序为铜>铅>铬>锌>镉,加标回收率为98.45%~99.45%,相对标准偏差小于0.78%.该法回收率和准确度高,精密度和重复性好,在中草药重金属含量分析中具有良好的...  相似文献   

11.
采用氯化铵-氨水体系溶解试样,干过滤后,向移取的滤液中加入氯化钡和硫酸共沉淀铅离子,过滤分离硫酸铅沉淀,向滤液中加人抗坏血酸、氟化钾、硫代硫酸钠等掩蔽剂掩蔽少量干扰元素。在pH=5~6的乙酸-乙酸钠缓冲溶液中,以二甲酚橙为指示剂,用EDTA标准滴定溶液滴定测得结果为氧化锌、水溶性锌和镉合量,扣除由原子吸收光谱法测得的水溶性锌量和镉量,即为氧化锌量。对总氨浓度、氯化铵-氨水浓度比、溶液加入量、搅拌时间、共存离子干扰、精密度等进行了实验,建立了EDTA滴定法测定含锌物料中氧化锌物相的分析方法。实验证明,氧化锌含量在24%~83%时,方法精密度(RSD)为0.25%~0.54%,加标回收率在99%~104%,完全满足含锌物料中氧化锌的测定要求。  相似文献   

12.
建立火焰原子吸收光谱法测定粗锌中的铜含量。采用硝酸–酒石酸溶解样品,并以其为测定溶液介质,检测波长为324.7 nm,以水为参比,采用空气–乙炔火焰以原子吸收光谱仪进行测定。在优化的实验条件下,铜的质量浓度在0.10~2.50μg/m L范围内与吸光度有良好线性关系,相关系数为0.999 7,方法检出限为0.01μg/m L。测定结果的相对标准偏差为1.0%~3.0%(n=11),样品加标回收率为97%~102%。该方法具有灵敏度高,干扰少,重现性好等优点,适用于铜含量在0.001%~0.50%之间的粗锌中铜的测定。  相似文献   

13.
Microwave assisted pre-treatments for atomic spectrometric determination (inductive coupled plasma-optical emission spectrometry, ICP-OES or flame atomic absorption spectrometry, FAAS) of metallic elements, usually present in antidandruff shampoos, are proposed. They are based on the digestion of the sample with HNO3 into a closed reactor, which is irradiated at 800 W for a few minutes. Selenium was determined by ICP-OES. The limit of detection was 0.11 mg l−1; the relative standard deviation (R.S.D.) for the selenium content in the samples was in the 0.6–3.6% range. The results obtained were in agreement with the label contents and the recovery of the proposed method was in the 100–106% range. Zinc and cadmium were determined by FAAS. The limit of detection for zinc determination was 0.078 mg l−1; the R.S.D. for zinc contents was in the 0.8–8.6% range. A limit of detection of 0.09 mg l−1 was obtained for cadmium determination; the R.S.D. for cadmium contents was in the 0.7–2.7% range. The determinations were performed after two different sample mineralization pre-treatments — dry ashing (in an electric furnace) and wet mineralization (in a microwave oven). Both methodologies provided comparable results for zinc and cadmium determination in shampoos. The proposed microwave assisted digestion procedures allow a precise and accurate determination of selenium, zinc and cadmium in commercial antidandruff shampoos, and the sample pre-treatment is less time-consuming than the classic methods.  相似文献   

14.
建立了电感耦合等离子体发射光谱法测定直接法氧化锌中铝、铜、铅、铁、镉、锰元素含量的分析方法。确定了溶样方法和分析谱线,对方法精密度和准确度进行了考察,结果表明,各元素的相对标准偏差在2.5%~6.5%,加标回收率在92%~105%,测定结果与其它经典分析方法测定结果一致。所建立的方法准确、快速,适用于直接法氧化锌中多元素同时测定。  相似文献   

15.
研究了湿法冶炼产出的析出锌,经过冲床冲压脱模、马弗炉高温熔化、模具浇铸成型、车床切削等过程,于直读光谱仪上测定析出锌中铅、铜、铁、镉、锡、铝含量的方法。通过实验确认了仪器的工作条件、熔样器皿、熔样温度、析出锌取样位置,并对熔样铸锭后铅、铜、铁、镉、锡、铝的偏析情况进行了分析,铅最大偏差达到30%,经玻璃棒搅动后保温,铅的偏差消除,拟定了直读光谱法测定析出锌中铅、铜、铁、镉、锡、铝含量的方法,应用后可以快速出具分析结果,指导生产。  相似文献   

16.
采用火焰原子吸收光谱法进行镉镍电池陶瓷绝缘子镀液中锌、铜、铁含量的连续测定。在优化条件下.该方法灵敏度高,干扰小,选择性和重现性好,步骤简单,操作容易,分析周期短。测定结果的相对标准偏差均小于1.0%,加标回收率为97.0%~99.0%。该法适用于镉镍电池陶瓷绝缘子镀液中锌、铜、铁含量的现场控制分析和样品系统分析。  相似文献   

17.
称取0.25 g样品加入5ml硝酸和2ml氢氟酸,用微波消解技术对样品进行前处理。以Re作为As、Pb、Tl的内标,Rh作为Cd、Co、Cr、Ni的内标,Bi作为Be、Cu、Zn的内标,Tb作为V的内标,建立了KED模式下可同时测定土壤中Be、As、Cd、Co、Cr、Cu、Ni、Pb、Tl、V、Zn 11种金属元素的微波消解ICP-MS方法。该方法线性关系良好,线性相关系数均在0.9990以上,检出限为0.002mg/kg-0.054 mg/kg。检测土壤标准物质GSS-17、GSS-18验证方法准确性,结果显示测定值均在标准差允许范围内,相对标准偏差在0.29%-5.33%,是一种快速、可靠的土壤多种金属元素检测方法。  相似文献   

18.
A novel, simple and sensitive adsorptive stripping voltammetry method was developed for simultaneous determination of Cd and Zn using N‐Nitrozo‐N‐phenylhydroxylamine (Cupferron) as a selective complexing agent. Cadmium and zinc metals gave peaks that were distinctly separated by 450–1200 mV, allowing their determination over a wide range of concentrations. The influence of pH and the nature of supporting electrolytes, concentration of ligand, preconcentration time and applied potential were investigated. The detection limits were 0.058 ng/mL for Zn and 0.092 ng/mL for Cd, and the RSD at a concentration level of 50 ppb, were 1.8–2.1 % for both zinc and cadmium, respectively. The method was applied to the determination of cadmium and zinc in blood, drug, food and water samples with the satisfactory results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号