首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 328 毫秒
1.
A normal pressure MWPC for beam diagnostics at RIBLL2 has been developed, which has a sensitive area of 80mm×80mm and consists of three-layer wire planes. The anode plane is designed with a wider frame to reduce the discharge and without using protection wires. The detector has been tested with a (55)Fe X-ray source and a 200 MeV/u(12)C beam from CSRm. A position resolution better than 250 μm along the anode wires and a detection efficiency higher than 90% have been achieved.  相似文献   

2.
中国科学院近代物理研究所气体探测器组研制了一种大型位置灵敏的平行板雪崩计数器(PPAC)。它主要由中心阴极和X,Y位置阳极构成,灵敏面积为244 mm×284 mm,阴极为双面镀金1.5 μm厚的Mylar膜,阳极为直径20 μm,间距1 mm的镀金钨丝。位置读出选用延迟块读出法。这种探测器经测试在灵敏面积内位置分辨小于4 mm,时间分辨为0.42 ns,已在兰州放射性束流线(RIBLL)上清华大学的核反应实验中使用。该实验中使用了主束40Ar直接轰击Au靶,产生裂变碎片,使用了4个这种大型位置灵敏的PPAC,用来探测裂变碎片的飞行时间和速度,实验表明,PPAC对裂变碎片有90.3%的效率,给出了裂变碎片的位置分布,为理论分析工作提供了非常好的实验数据。A kind of large position sensitive parallel plate avalanche counter(PPAC) was developed at Gas Detector Research Group, Institute of Modern Physics of CAS. Each of the detector with large sensitive area of 244 mm×284 mm, consists of one central cathode, X anode and Y anode. The cathode plane in the middle of detector is a 1.5 μm thick Mylar foil coated with a thin Au-layer on both sides. The position resolution of the PPAC is better than 4 mm, and the time resolution is 0.42 ns. The detectors were used in the fission experiment with 30MeV/u 40Ar beam bombarding on a gold target to measure the velocity of the fission fragments at Radioactive Ion Beam Line In Lanzhou(RIBLL). Four PPACs were used and the experiment result showed that a rather high detection efficiency (90.3%) is achieved. The position distribution of fission fragments is given by PPACs, which provides very good experimental data for further theoretical analysis.  相似文献   

3.
The structure of micromegas (micro-mesh gaseous structure) detectors with different micro-meshes of stainless steel wire woven netting and Ni foil has been presented. The counting rates, energy resolution, gain, discharge probability and time resolution have been measured. Wider counter plateaus and gain for the developed detector were obtained. Excellent energy resolution of the micromegas detector, 17% (FWHM) based on Ni foil micro-mesh and 25% (FWHM) based on stainless steel wire woven netting micro-mesh, has been obtained for the 5.9 keV photon peak of the 55Fe X-ray source in an Ar/CO2(10%) gas mixture. The best time resolution at -620 V micro-mesh voltage and -870 V drift voltage is 14.8 ns for cosmic rays in an Ar/CO2(10%) gas mixture. These results satisfy the basic demand of the micromegas detector preliminary design.  相似文献   

4.
A 2D neutron detector based on 3 He convertor and MWPC with an active area of 200 mm×200 mm has been successfully designed and fabricated.The detector has been tested with Am/Be neutron source and with collimated neutron beam with the wavelength of =1.37.The best spatial resolution of 1.18 mm(FWHM) and good linearity were obtained.This is in good agreement with theoretical calculations.  相似文献   

5.
介绍了Si-APD的工作原理并对Si-APD中的暗电流进行了理论分析。基于RIBLL上产生的放射性核束流,使用CsI(Tl)+Si-APD探测器对中能重离子进行了能量测试。测试结果显示,CsI(Tl)+Si-APD探测器测量20 MeV/u的重离子时,可得到3%的能量分辨;同时还发现Si-APD中的暗电流大小以及入射粒子的能量大小都会对探测器的能量分辨产生影响。In this paper, the working principle of Si-APD was introduced and the dark current of Si-APD was analyzed theoretically. The intermediate energy heavy ions, which are produced on the RIBLL(Radioactive Ion Beam Line in Lanzhou), were measured with CsI(Tl)+Si-APD detector. The energy resolution of CsI(Tl)+Si-APD detector is about 3% for heavy ions with energy around 20 MeV/u. It is also found that the energy resolution of detector can be in uenced by the dark current of Si-APD and the energy of incident particles.  相似文献   

6.
为兰州第二条放射性束流线(RIBLL2)研制了一台用于ΔE测量的纵向场多次取样型电离室。 利用3组分α源(239Pu为3.435 MeV, 241Am为3.913 MeV, 244Cm为4.356 MeV)对取样单元进行了测试, 确定了电离室的最佳工作电压为-500 V, 沉积能量为3.435 MeV时, 取样单元的能量分辨为271.4 keV(FWHM)。 利用Geant4对此电离室的整体性能进行了模拟, 表明可以对Z≥4的离子实现较好的粒子鉴别。 A longitudinal field MUltiple Sampling Ionization Chamber (MUSIC), which makes multiple measurements of energy loss for very high energy heavy ions at RIBLL2, has been constructed and tested with 3 constituent α source (239Pu: 3.435 MeV, 241Am: 3.913 MeV, 244Cm: 4.356 MeV). The voltage plateau curve has been plotted and -500 V is determined as a proper work voltage. The energy resolution is 271.4 keV FWHM for the sampling unit when 3.435 MeV energy deposited. A Geant4 Monte Carlo simulation is made and it indicates the detector can provide unique particle identification for ions Z≥4.  相似文献   

7.
A position-sensitive detector is designed for neutron detection. It uses a single continuous screen of a self-made lithium glass scintillator, rather than discrete crystal implementations, coupling with a multi-anode PMT (MaPMT). The scintillator is fast and efficient; with a decay time of 34 ns and thermal neutron detection efficiency of around 95.8% for the 3 mm thick screen, and its light yield is around 5670 photons per neutron and 3768 photons per MeV γ rays deposition. The spatial resolution is around 1.6 mm (FWHM) with the energy resolution around 34.7% by using α (5.2 MeV) rays test.  相似文献   

8.
25 MeV/u 6He+9Be反应的实验中利用多个探测器望远镜对反应产物进行了测量, 对实验中各个角度测量到的4He进行观察, 将其中两个有高能峰成分的探测器划分成三部分, 得到不同角度4He的单举能谱和破裂产生4He的微分截面. Different products of 6He nuclei from 9Be target has been measured with a 6He beam at energy of 25 MeV/u. The energy spectra at different angles for 4He isotope were analyzed and the experiment differential cross sections for the direct breakup reaction were obtained.  相似文献   

9.
A low background thermal neutron flux detection system has been designed to measure the ambient thermal neutron flux of the second phase of the China Jinping Underground Laboratory(CJPL-Ⅱ),right after completion of the rock bolting work.A ~3He proportional counter tube combined with an identical ~4He proportional counter tube was employed as the thermal neutron detector,which has been optimised in energy resolution,wall effect and radioactivity of construction materials for low background performance.The readout electronics were specially designed for long-term stable operation and easy maintenance in an underground laboratory under construction.The system was installed in Lab Hall No.3 of CJPL-Ⅱ and accumulated data for about 80 days.The ambient thermal neutron flux was determined under the assumption that the neutron field is fully thermalized,uniform and isotropic at the measurement position.  相似文献   

10.
随着国内高通量中子源及中子散射谱仪的快速发展,对高探测效率、高位置分辨、低伽玛灵敏度的位置灵敏型热中子探测器需求日益迫切。目前国际上中子散射谱仪大多数采用了基于3He的热中子探测器,由于当前3He价格昂贵,寻求3He替代型热中子探测器的相关研究任务紧迫。提出了一种基于10B4C转换体的多层多丝正比室新型二维位置灵敏型热中子探测器,并利用蒙特卡罗模拟软件Geant4和Garfield++对其探测效率、位置分辨、n/γ抑制比等性能展开了详细的模拟研究。结果表明,当多丝正比室单元为40层,阈值为200 keV时,热中子(E=0.025 eV)探测效率可达到~54%,位置分辨为2.6 mm (FWHM),n/γ抑制比为~107,可以满足大多数中子散射谱仪的需求,为此类探测器设计及实验研究提供了理论依据。As the development of high flux neutron sources and neutron scattering spectrometers in China, more and more neutron detectors with high detection efficiency, high position resolution, high time resolution and low gamma sensitivity are need ungently. 3He based neutron detector is one of the best options. Recently, because of the 3He gas shortage and its expensive price, we must find a new replacement of 3He. A two-dimensional position sensitive neutron detector based on multi-layer Multi Wires Proportional Chambers (mMWPC) with 10B4C converter was proposed in this paper. The neutron detection efficiency, position resolution and γ compression were simulated with Geant4 and Garfield++. The results show that with 40 layers of neutron convertor, high themal neutron (E=0.025 eV) detection of~54%, best position resolution of 2.6 mm (FWHM) and high n/γ rejection ratio of~107 with the threshold of 200 keV can be achieved, which can meet the requirements of most spectrometers. This simulation results lay a good foundation for the next step of detector construction and test.  相似文献   

11.
The structure of micromegas (micro-mesh gaseous structure) detectors with different micro-meshes of stainless steel wire woven netting and Ni foil has been presented. The counting rates, energy resolution, gain, discharge probability and time resolution have been measured. Wider counter plateaus and gain for the developed detector were obtained. Excellent energy resolution of the micromegas detector, 17% (FWHM) based on Ni foil micro-mesh and 25% (FWHM) based on stainless steel wire woven netting micro-mesh, has been obtained for the 5.9 keV photon peak of the 55Fe X-ray source in an Ar/CO2(10%) gas mixture. The best time resolution at -620 V micro-mesh voltage and -870 V drift voltage is 14.8 ns for cosmic rays in an Ar/CO2 (10%) gas mixture. These results satisfy the basic demand of the micromegas detector preliminary design.  相似文献   

12.
The characteristics of scintillation counters measured in a 90-MeV proton beam have been presented. Two-meter long scintillators BC-404 and BC-408, which were viewed from both ends with photoelectron multipliers R1828-01 (PMT) have been used. Both the amplitude and time distributions of the PMT signals are well described by the Gaussian function. It turned out that the amplitude resolution σ(А)/А weakly depends on the type of scintillator and the proton position along the counter, and lies in the interval between 4 and 5%. The best time resolution σ(T) is about 50 ps near the counter ends and 63 ps at the center.  相似文献   

13.
高能量分辨率的平面晶体位置灵敏谱仪   总被引:2,自引:0,他引:2  
平面晶体波长色散位置灵敏谱仪是一新型高能量分辨率的X射线分析装置,可用于高能量分辨的元素分析、化学态及原子物理等研究中.这里简要介绍所研制的位置灵敏谱仪装置及其性能,以及位置灵敏谱仪与其核心部件──位置灵敏正比计数器的基本原理.所研制位置灵敏谱仪对55Fe,Ti和Si所达到的能量分辨率(FWHM)分别为25eV,15eV及7eV.因此,它将可以用作高分辨的元素分析.  相似文献   

14.
A scanning transmission X‐ray microscope is operational at the 10A beamline at the Pohang Light Source. The 10A beamline provides soft X‐rays in the photon energy range 100–2000 eV using an elliptically polarized undulator. The practically usable photon energy range of the scanning transmission X‐ray microscopy (STXM) setup is from ~150 to ~1600 eV. With a zone plate of 25 nm outermost zone width, the diffraction‐limited space resolution, ~30 nm, is achieved in the photon energy range up to ~850 eV. In transmission mode for thin samples, STXM provides the element, chemical state and magnetic moment specific distributions, based on absorption spectroscopy. A soft X‐ray fluorescence measurement setup has been implemented in order to provide the elemental distribution of thicker samples as well as chemical state information with a space resolution of ~50 nm. A ptychography setup has been implemented in order to improve the space resolution down to 10 nm. Hardware setups and application activities of the STXM are presented.  相似文献   

15.
 利用双狭缝、透射光栅配亚仟X光条纹相机做了具有一维空间、时间和能谱分辨的三维软X光测量仪器(双狭缝透射光栅软X光时空分辨谱仪), 并成功地获得了金盘靶的N带X光(中心波长1.7nm)时空分辨图象 。该仪器空间分辨可达23μm, 时间分辨可达003ns, 能谱分辨(当源大小为100~300μm时对波长1.7nm的X光)可达0.4~ 0.7nm, 只需稍加改动, 即可用于其它波段的X光测量。  相似文献   

16.
Micro-gas chambers (MGC) have been produced with a gain of ~500 and the enegy resolution (FWHM) of ~14% for 55Fe 5.9keV X-ray at anode voiltage of 380V.  相似文献   

17.
描述了北京谱仪桶部簇射计数器(BanelShowerCounter)的改进升级工作,改进后的桶部簇射计数器在能量分辨和位置分辨方面有了明显的提高,经对Bhabha事例进行离线刻度后,能量分辨好于21%,z向位置分辨小于3cm.  相似文献   

18.
Timing and amplitude properties of a prototype scintillator TOF counter at an external target facility are studied with a cosmic rays test. The dependence of signal pulse height and time resolution on the coordinate along the scintillator TOF counter is investigated with two different discriminators. A time resolution of 165 ps can be achieved at the center of the counter with a constant fraction discriminator. Time resolution better than 150 ps is obtained at the center with a leading edge discriminator after time walk correction is applied for off-line analysis.  相似文献   

19.
Timing and amplitude properties of a prototype scintillator TOF counter at an external target facility are studied with a cosmic rays test. The dependence of signal pulse height and time resolution on the coordinate along the scintillator TOF counter is investigated with two different discriminators. A time resolution of 165 ps can be achieved at the center of the counter with a constant fraction discriminator. Time resolution better than 150 ps is obtained at the center with a leading edge discriminator after time wall( correction is applied for off-line analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号