首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We demonstrate experimentally an atomic magnetometer based on optical pumping theory, a magnetic resonance that is induced by a radio frequency field and dependent on the magnetic field strength. Compared with the conventional method using one radiation field, which is used not only as the probe beam but also as a pump beam, the additional re-pump beam can increase remarkably the amplitude of the signal. It is shown that the amplitude of the magnetic field resonance signal can increase more than 55% by using an additional re-pump beam, which makes the sensitivity of the magnetometer higher. Finally, we investigate the relation between amplitude of the signal and re-pump laser power, and calculate the atomic population in the trapping states with rate equations.  相似文献   

2.
A simple Erbium Doped Fiber Laser (EDFL) in linear cavity configuration is reported. The cavity design is based on an FBG as a back reflector, and a loop back optical circulator with an output coupler as the front reflector. Different coupling ratios of the coupler are tested and 50: 50 provides the highest coupling output power of 22.06 dBm (160.7 mW). The pump power conversion efficiency is about 95% when pumping with two pump lasers at 1460 and 1490 nm with combined pumping power of 545 mW. The laser output has a measured linewidth of 0.0179 nm.  相似文献   

3.
Wyllie R  Kauer M  Wakai RT  Walker TG 《Optics letters》2012,37(12):2247-2249
We describe an array of spin-exchange-relaxation-free optical magnetometers designed for detection of fetal magnetocardiography (fMCG). The individual magnetometers are configured with a small volume with intense optical pumping, surrounded by a large pump-free region. Spin-polarized atoms that diffuse out of the optical pumping region precess in the ambient magnetic field and are detected by a probe laser. Four such magnetometers, at the corners of a 7 cm square, are configured for gradiometry by feeding back the output of one magnetometer to a field coil to null uniform magnetic field noise at frequencies up to 200 Hz. We present the first measurements of fMCG signals using an atomic magnetometer.  相似文献   

4.
激光光泵碱金属磁力仪具有很高的灵敏度,测量范围可以从地球磁场到生物磁场。给出了铯(Cs)光泵磁力仪的理论分析和系统设计以及磁场梯度测量原理,铯原子能级在I—J耦合时形成超精细结构,在外磁场的作用下超精细结构进一步产生塞曼分裂形成塞曼子能级,利用激光泵浦和射频磁场能够使电子在超精细结构中进行能级跃迁,产生光磁双共振的结果,最终通过共振频率就能够达到精确测量外磁场的目的。  相似文献   

5.
杨晨  左冠华  田壮壮  张玉驰  张天才 《物理学报》2019,68(9):90701-090701
利用适用于线极化Bell-Bloom测磁系统的布洛赫方程和含有自旋弛豫的速率方程,以铯原子为研究对象,分析了抽运光对磁场灵敏度的影响,并在实验上分别采用与铯原子D1线和D2线共振的线偏光作为抽运光和探测光,用充有缓冲气体的气室进行了实验.实验结果与理论分析一致,均表明只有在一定的光强范围内,增大抽运光光强可以提高磁场灵敏度.且利用这一方法分析了原子的自旋弛豫对磁场灵敏度的影响.这项研究对于深入认识线极化的Bell-Bloom测磁系统,以及如何通过优化系统实现磁场灵敏度的提高具有重要的意义.  相似文献   

6.
基于中红外光源的气体光谱检测是新的痕量气体监测与分析方法,在大气监测领域具有重要的应用。构建了一套基于中红外DFG光源的甲烷气体光谱检测系统。该系统以1 550 nm和1 060 nm波段可调谐半导体激光器作为基频光源,采用PPLN晶体作为差频非线性变频器件,实现了3.3 μm处的窄线宽可调谐中红外光源输出。实验结果表明,当PPLN晶体工作温度为99.5℃时,闲频光的输出功率为112 μW,差频转换效率达到1.246 mW/W2。晶体的温度接受带宽为4.3℃,泵浦光波长接受带宽为5.3 nm。在此基础上,分别利用直接吸收法和谐波检测法获得了3 028.751 cm-1处的甲烷气体吸收光谱和二次谐波检测信号。  相似文献   

7.
半导体泵浦铷蒸气激光器国内首次出光北大核心CSCD   总被引:4,自引:4,他引:0       下载免费PDF全文
采用体光栅对商用线阵半导体激光器进行线宽压缩,得到线宽0.1nm、中心波长780.2nm、最高连续输出功率80W的泵浦激光输出。为了降低热效应,通过外加斩波器将泵浦光转化为脉冲模式,脉宽440μs,占空比为1∶5。采用长度为5mm的铷金属饱和蒸气作为增益介质,并在常温下充入33kPa乙烷和47kPa氦气,进行了出光实验。在泵浦峰值功率35.4W,铷吸收池温度120℃时,得到峰值功率600mW的795nm铷激光输出,斜率效率为1.7%。  相似文献   

8.
LD抽运Cr,Tm,Ho∶YAG微片激光器单纵模运转特性的研究   总被引:1,自引:0,他引:1       下载免费PDF全文
研究了LD抽运的单纵模Cr,Tm,Ho∶YAG微片激光器,激光器厚度为1?mm,在用波长785?nm的LD进行端面抽运时,激光器阈值为1060?mW,单纵模激光最大输出功率为31?mW. 对激光器输出功率随温度变化特性进行了研究,验证了CTH∶YAG晶体的温度敏感性. 还研究了激光器的温度调谐特性,实验测得激光器的温度调谐系数为14?GHz/℃. 关键词: 激光光学 CTH∶YAG微片激光器 LD抽运 单纵模运转  相似文献   

9.
We experimentally investigate the laser characteristics of a series of short pieces of newly-developed Er3+/Yb3+ codoped single mode phosphate glass fibres via the cladding pump of a 976nm multimode laser diode. A stablecontinuous-wave single transverse mode laser with over 85mW at 1553nm is generated from a 5.5-cm-long active fibre. Single mode laser output power per unit length is up to 15mW/cm. Moreover, the slope efficiency is 11.8% when the pump power is below 940mW and the 3dB linewidth is 0.06nm at the maximum pump power. The numerical simulation results show that the laser emission slope efficiency can exceed 20% by means of increasing the coupling efficiency of the pump to the fibre core further.  相似文献   

10.
Continuous-wave laser oscillation of Cr(3+):MgO at room temperature was realized under argon-ion laser pumping at 476 and 514 nm. The free-running laser wavelength was 840 nm, and with different mirror sets laser oscillation at 824, 830, 870, and 878 nm was also realized. With different crystals a maximum output power of 48 mW and a lowest threshold with respect to the absorbed pump power of 80 mW were realized. The slope efficiencies with respect to the absorbed pump power were as high as 2.3%. No thermal effects were observed for absorbed pump powers as great as 2.7 W.  相似文献   

11.
基于外腔的高效频率转换, 尤其是当系统运行在抽运不消耗近似机理下, 信号光可实现大于90%的转换, 因此无法通过信号光直接获得其到腔模频率锁定的误差信号. 本文通过对信号光调制、和频光解调的方法获得了该误差信号, 实现了双波长激光到外腔腔模的级联锁定. 实验中外部环形腔将1.3 W的1064 nm抽运光放大到约14.3 W. 当1583 nm信号光从10 μW变化到50 mW, 其到636 nm和频光的转化效率约为73%; 当从50 mW变化到295 mW时, 转换效率呈线性降低到60%, 最终获得了440 mW的636 nm激光.  相似文献   

12.
Nd:YAG laser pumped at 946 nm   总被引:1,自引:0,他引:1  
Goldring S  Lavi R 《Optics letters》2008,33(7):669-671
A Nd:YAG laser crystal was pumped at 946 nm and lased at 1064 nm. This pump-lase format was investigated in order to reduce the quantum defect between the pump and laser photons as compared to other pump schemes of this material. To the best of our knowledge, this is the first realization of this scheme. A room temperature absorption coefficient and linewidth of approximately 0.075 cm(-1) and approximately 1 nm for 1% at. Nd(+3) concentrations were measured for the 946 nm absorption line. Those parameters impose both narrow-bandwidth pumping and a long absorption path. By increasing the laser crystal temperature above room temperature, the absorption cross sections at 946 and 938 nm increase due to enhanced thermal population of the upper energy level of the ground manifold. The possibility of exploiting this phenomenon to enhance the pump absorption is also discussed.  相似文献   

13.
The effects of a strong control or pump laser, counter propagating or copropagating with the probe beam, on the probe absorption spectra of 85Rb and 87Rb-D2 transitions have been investigated inside a room temperature Rb vapour cell. In both cases a set of strong velocity selective resonance dips are observed at different velocities. Their movements across the Doppler broadened probe absorption profile have been studied for different lock frequencies of the control laser. These spectra are modified by optical pumping effects due to the presence of another hyperfine component of the ground state. A repumping laser, from the dark hyperfine component of the ground level transfers almost 75% of the atoms from the dark state to the pump probe cycle hence reducing the optical pumping effect. A numerical simulation is done to explain the observed spectra. The effect of a control laser on the Lamb dip spectrum of the probe laser has also been investigated. The control beam is used to improve the strength of a weak hyperfine dip on the Doppler broadened probe spectrum. The strength of the hyperfine dip increases by a factor of 3.2 in presence of the control laser. The observed dips show that pump-probe spectroscopy can be used as velocity selectors of atoms.  相似文献   

14.
杨未强  侯静  宋锐  刘泽金 《物理学报》2011,60(8):84210-084210
从理论上分析了高功率光纤激光器直接抽运和二级抽运的斜率效率和热管理问题. 计算结果表明:波长为975 nm的激光直接抽运产生波长为1070 nm的激光时,理论斜率效率为80%,但当抽运光功率为10 kW时,在强制水冷条件下纤芯极值温度也难以降到150 ℃以下;在二级抽运技术中,波长为1018 nm的激光抽运产生波长为1070 nm的激光时,若采用传统的包层抽运技术,其斜率效率不足20%,如果抽运功率填充因子由0.0025提高到0.1,则理论上斜率效率可由18.5%提高到80.9%,从而总斜率效率由15.5 关键词: 二级抽运 功率填充因子 斜率效率 热管理  相似文献   

15.
The performance characteristics of a doubly (signal and idler) resonant continuous-wave optical parametric oscillator based on periodically poled lithium niobate and pumped by a 100-mW single-mode laser diode at 810 nm are reported. Pump power thresholds as low as 16 mW and wavelength tuning over the range 1.15-1.25 microm at the signal and 2.31-2.66 microm at the idler were achieved through variation of crystal temperature, pump wavelength, and grating period. Up to 5 mW of signal output was obtained with the single-mode diode pump, and signal powers of up to 39 mW were obtained when pumping with a 400-mW injection-locked broad-area diode laser.  相似文献   

16.
高效全固化紫外四倍频激光器的研究   总被引:7,自引:0,他引:7  
用半导体激光器抽运的调Q YLF倍频激光器抽运掺钛蓝宝石激光器,用LBO晶体在腔内产生二次谐波,再聚焦到BBO晶体上产生四次谐波深紫外激光。为了提高谐波转换效率,在腔内分别插入了单片、组合双折射滤光片和聚焦透镜,在平均功率为3.6W,波长为527nm的抽运光下得到410mW,417nm的蓝光。用长焦距的透镜聚焦二次谐波,得到34mW,208nm的紫外脉冲激光。从实验上详细研究了基频光的线宽对二次谐波效率的影响,二次谐波的线宽对四次谐波效率的影响、基频光的波长对四次谐波产生效率的影响。全面地分析了单片和组合大拆射滤光片及抽运功率对钛蓝宝石激光器基频光的脉宽、线宽等参量的影响。  相似文献   

17.
提出了一种基于高掺杂硅酸盐增益光纤、输出波长为1 064nm的超短腔单频光纤激光器.该单频光纤激光器采用分布布拉格反射式腔型结构,有效腔长为2cm,其增益介质为1.1cm长的高浓度掺Yb3+光纤.通过恰当的温度控制,获得了线宽为4.8kHz的稳定单频激光输出.当注入泵浦光为378mW时,输出功率为13mW,斜效率为3.4%.在频率大于1 MHz时,测得该光纤激光器的相对噪声强度值约为-132dB/Hz.采用主振荡功率放大结构,对该单频光纤激光器的输出功率进行放大.当放大增益光纤长度选取为56cm时,得到了325mW的最大输出功率,其斜效率为52.8%.  相似文献   

18.
史久林  许锦  罗宁宁  王庆  张余宝  张巍巍  何兴道 《物理学报》2019,68(4):44201-044201
为提高液体介质中受激拉曼散射的输出能量,提出了通过温度调控来抑制受激布里渊散射的方法,设计了532 nm多纵模宽带脉冲激光泵浦的受激拉曼散射发生系统,测量了不同温度下水中前向受激拉曼散射及后向受激布里渊散射的输出能量,分析了水温、泵浦激光线宽及热散焦效应对受激拉曼散射输出能量影响的物理机制.实验结果表明:通过降低水温可实现对受激布里渊散射过程的有效抑制,同时减小热散焦效应带来的光束畸变,从而有效提高受激拉曼散射的输出能量.研究结果对液体介质中的受激拉曼散射多波长转换具有重要意义.  相似文献   

19.
钛宝石泵浦的Yb:YAG晶体的激光性能   总被引:1,自引:0,他引:1  
测量了Yb:YAG晶体的光谱特性,用Ar+离子泵浦钛宝石激光器作为泵浦源泵浦Yb:YAG晶体,采用平平腔设计,当输出耦合镜T1.053μm=4.26%,泵浦功率为1410mW时,得到320mW1.053μm的高效CW激光输出,斜率效率为54%,外推阈值功率为203mW。  相似文献   

20.
Efficient continuous-wave laser operation of Cr2+:ZnSe was demonstrated with an output power of 1400 mW at an absorbed pump power of 1900 mW from a Tm:YAG laser. Under continuous-wave diode pumping at 1.54 μm an output power of 15 mW was obtained from a Cr+2:ZnSe laser. Excited state absorption is shown to be negligible in the pump and laser spectral region. Received: 12 October 2000 / Published online: 30 November 2000  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号