共查询到20条相似文献,搜索用时 62 毫秒
1.
2.
3.
本文在比较检测波长以及不同提取方法的基础上,优化了测定拟穴青蟹血淋巴、肌肉、鳃和肝胰腺等组织中磺胺嘧啶和甲氧苄啶含量的反相高效液相色谱法(RPHPLC)。采用Aglient Zorbax SB-C18柱(150×4.6mm,5μm),以乙腈和0.01mol·L~(-1)乙酸铵(乙酸调节pH为3.80)为流动相,柱温35℃;紫外检测波长245nm;进样量10μL,流速1.0mL·min-1。磺胺嘧啶在0.05~10μg·mL~(-1)范围内线性关系良好,相关系数R2=0.9999。甲氧苄啶在0.05~10μg·mL~(-1)范围内线性关系良好,相关系数R2=0.9999。采用乙腈提取青蟹血淋巴、肌肉、肝胰腺和鳃组织中磺胺嘧啶和甲氧苄啶,加标回收率分别为82.26%~95.23%、81.52%~98.59%,日内精密度分别为1.77%~2.53%、1.75%~4.09%,日间精密度分别为2.27%~3.30%、1.95%~4.82%;定量限分别为0.05μg·mL~(-1)、0.05μg·g-1。该方法操作简单,重现性好,药峰无干扰,适用于青蟹样品中磺胺嘧啶和甲氧苄啶含量的同时分析测定。 相似文献
4.
建立了一种超高效液相色谱-串联质谱法(UPLC-MS/MS)测定多种基质(鸡肉、鱼肉、鸡肝、鸡蛋和牛奶)中三甲氧苄氨嘧啶的分析方法。样品用甲酸-乙腈(1:9,V/V)溶液提取,正己烷除脂净化,Acquity UPLC BEH C18柱(1.7μm,2.1 mm×50 mm)分离,以甲醇和体积分数0.1%甲酸5 mmol乙酸铵(V/V)作为流动相进行梯度洗脱,电喷雾正离子(ESI+)模式电离,多反应监测(MRM)模式检测。结果表明:三甲氧苄氨嘧啶质量浓度在1.25~15.0μg/L范围内线性关系良好(r≥0.99)。方法的定量限(信噪比为10)为5.0μg/kg,在5.0,10.0μg/kg添加浓度的回收率为61.2%~108.5%,相对标准偏差(n=6)在1.4%~9.8%之间。方法适合于多种基质中三甲氧苄氨嘧啶的测定。 相似文献
5.
建立了一种超高效液相色谱-串联质谱(UPLC-MS/MS)测定多种基质(鸡肉、鱼肉、鸡肝、鸡蛋和牛奶)中三甲氧苄氨嘧啶、二甲氧苄胺嘧啶和二甲氧甲基苄胺嘧啶的分析方法。样品用甲酸-乙腈(1:9,v/v)溶液提取,正己烷除脂净化,Acquity UPLC BEH C18柱(50 mm×2.1 mm,1.7 μm)分离,以甲醇和5 mmol/L醋酸铵(含0.1%(v/v)甲酸)作为流动相进行梯度洗脱,电喷雾正离子(ESI+)模式电离,多反应监测(MRM)模式检测。考察了3种提取溶液的提取效率,优化了净化条件和浓缩条件,并对流动相、柱温和固相萃取柱进行了优化。结果表明:三甲氧苄氨嘧啶、二甲氧苄胺嘧啶和二甲氧甲基苄胺嘧啶在1.25~30.0 μg/L范围内线性关系良好(r≥0.99)。方法的定量限(S/N=10)为5.0 μg/kg,在5.0、10.0、20.0 μg/kg的添加浓度的回收率为61.2%~108.5%,相对标准偏差(RSD,n=6)为1.1%~9.8%。该方法快速、灵敏、准确,适合于多种基质中磺胺增效剂的测定。 相似文献
6.
毛细管电泳-电化学检测法测定饲料中的磺胺类药物 总被引:1,自引:0,他引:1
采用毛细管电泳-电化学检测法(CE-ED),对饲料中的6种磺胺类药物磺胺脒、磺胺二甲嘧啶、磺胺甲嘧啶、磺胺二甲氧嘧啶、磺胺嘧啶、磺胺甲恶唑进行了分离和测定。分别考察了工作电极电位、运行缓冲液的pH和浓度、分离电压和进样时间等实验参数对实验结果的影响。在优化的实验条件下,以直径300μm的碳圆盘电极为工作电极,检测电位为0.95 V(vs.SCE),在30 mmol/L硼砂-KH2PO4(pH7.6)的运行缓冲溶液中,6个分析物能够在16 min内实现很好的基线分离,被测物浓度与峰电流在3个数量级呈良好的线性,检出限(S/N=3)范围0.08~0.20μg/mL。该方法已应用于实际样品的分析。 相似文献
7.
建立了非磺胺类兽药粉剂中磺胺二甲嘧啶、磺胺醋酰、磺胺甲噻二唑、磺胺氯哒嗪、磺胺甲基异唑、磺胺噻唑、磺胺-6-甲氧嘧啶、磺胺甲基嘧啶、磺胺邻二甲氧嘧啶、磺胺吡啶、磺胺对甲氧嘧啶、磺胺甲氧哒嗪、磺胺苯吡唑、磺胺间二甲氧嘧啶、磺胺二甲异唑、磺胺喹啉、磺胺嘧啶、甲氧苄氨嘧啶18种磺胺及其增效剂等违禁添加药物的超高效液相色谱-串联质谱分析方法。样品经甲醇-水(90∶10)萃取后,以乙腈(含0.1%甲酸)和水(含0.1%甲酸)为流动相,C18(2.1 mm×150 mm,5μm)色谱柱分离后,在正离子模式下以电喷雾串联质谱仪进行测定。方法的线性范围为50~2 000μg/kg,18种磺胺类药物残留的检出限为10μg/kg。在50,200,1 000μg/kg 3个浓度水平下进行加标回收实验,平均回收率为86.8%~115%,相对标准偏差为1.0%~9.7%。 相似文献
8.
研制了甲氧苄啶分子印迹吸附萃取搅拌棒涂层,并应用于复杂样品中痕量甲氧苄啶和磺胺药物的分析。分子印迹涂层的厚度约为21.5μm,相对标准偏差为5.9%(n=10),涂层均匀、致密,具有良好的热稳定性和化学稳定性。分子印迹涂层的萃取容量是非印迹涂层萃取容量的1.7倍,分子印迹涂层对抗菌增效剂、磺胺药物、三嗪化合物和甲氨蝶呤都表现出良好的选择性吸附萃取能力。建立了分子印迹吸附萃取搅拌棒联用高效液相色谱的分析方法,成功应用于加标尿样和血浆中痕量甲氧苄啶的分析,线性范围为5~200μg/L,检出限为1.6μg/L,在尿样和血浆中的回收率范围分别为84.5%~91.7%和71.9%~85.1%,标准偏差分别为2.9%~4.4%和3.0%~7.3%。该方法还应用于加标牛奶中痕量磺胺药物的分析,线性范围为10~200μg/L,检出限在4.5~6.1μg/L之间,回收率为83.2%~110.2%,标准偏差为4.1%~8.0%. 相似文献
9.
10.
在硫酸介质中,高锰酸钾可以氧化甲氧苄啶发生化学发光反应,硫代硫酸钠对这一化学发光反应有极强的增敏作用。采用流动注射技术,建立了高锰酸钾甲氧苄啶硫代硫酸钠化学发光体系测定甲氧苄啶的化学发光新方法.考察了各种影响因素,确立了反应的最佳条件。方法的检出限为3.8×10-8 g/mL甲氧苄啶;线性响应范围为1×10-7~1×10-5 g/mL。对4×10-6 g/mL甲氧苄啶进行11次平行测定,相对标准偏差为1.8%。方法已成功地用于片剂中甲氧苄啶含量的测定,结果与药典标准法测得值一致。 相似文献
11.
Kambiz A. Mahabadi Isabel Rodriguez Chee Y. Lim Devendra K. Maurya Peter C. Hauser Nico F. de Rooij 《Electrophoresis》2010,31(6):1063-1070
An optimized capacitively coupled contactless conductivity detector for microchip electophoresis is presented. The detector consists of a pair of top–bottom excitation electrodes and a pair of pickup electrodes disposed onto a very thin plastic microfluidic chip. The detection cell formed by the electrodes is completely encased and shielded in a metal housing. These approaches allow for the enhancement of signal coupling and extraction from the detection cell that result in an improved signal‐to‐noise‐ratio and detection sensitivity. The improved detector performance is illustrated by the electrophoretic separation of six cations (NH, K+, Ca2+, Na+, Mg2+, Li+) with a detection limit of approximately 0.3 μM and the analysis of the anions (Br?, Cl?, NO, NO, SO, F?) with a detection limit of about 0.15 μM. These LODs are significantly improved compared with previous reports using the conventional top–top electrode geometry. The developed system was applied to the analysis of ions in bottled drinking water samples. 相似文献
12.
13.
14.
15.
Frank-Michael Matysik 《Mikrochimica acta》2008,160(1-2):1-14
Amperometric and conductometric detection are currently the two major electrochemical detection modes in capillary and chip
electrophoresis. The ease of miniaturization and integration of electrochemical detection elements offers a high potential
for the development of portable analytical devices based on electromigrative separations. The challenges and basic concepts
of both detection principles in the context of capillary/chip electrophoresis are shortly introduced and milestones of the
methodical developments are summarized from a historical perspective. Recent advances and applications are discussed with
more detail. Particular attention is paid to new trends in this area of research such as measurements in short capillaries
and the enormous progress and increased popularity of contactless conductivity detection.
Correspondence: Frank-Michael Matysik, Institute of Analytical Chemistry, University of Leipzig, Linnéstr. 3, D-04103 Leipzig,
Germany 相似文献
16.
毛细管电泳高频电导法测定虫草中的有效成份 总被引:1,自引:0,他引:1
建立了毛细管电泳高频电导法同时测定腺苷和虫草素的方法。实验对电泳介质的种类、浓度以及操作电压和进样时间等因素进行了优化,在4mmol/L乳酸+10%异丙醇+80μg/mL羟甲基纤维素钠(pH=4.0),分离电压20.OkV的条下测定了天然虫草和人工虫草菌丝制品中的腺苷和虫草素的含量,线性范围分别为2.0μg/mL~120μg/mL和3.0μg/mL~110μg/mL,检出限分别为0.5μg/mL和1.0μg/mL。 相似文献
17.
毛细管电泳高频电导法测定苦参中的苦参碱和氧化苦参碱 总被引:3,自引:1,他引:2
建立了用毛细管电泳高频电导法测定苦参药材中苦参碱和氧化苦参碱的方法。对电泳介质的种类、浓度、pH值以及操作电压和进样时间对分离检测的影响进行了研究。缓冲液为2.0mmol LNa2HPO4 1.0mmol LH3PO4 体积分数为25%乙醇(pH6.0),分离电压为16.0kV时可实现较好的分离与检测。苦参碱和氧化苦参碱的线性范围为:25.0~1.00×103μg mL(相关系数分别为0 987和0.999);RSD(n=6)分别为:2.1%和0.70%;检出限分别为10.0和5.00μg mL;回收率分别为92.7%~99.1%和100%~102%。 相似文献
18.
建立了毛细管电泳高频电导法快速简便测定牛黄粉中胆酸的新方法.考察了电泳介质的种类、浓度、 pH值以及操作电压和进样时间对分离检测的影响.缓冲液为0.5 mmol/L Na3PO4 2 mmol/L Na2HPO4 0.2 mmol/L CTAB(pH 11.7), 分离电压为 -15 kV时可实现较好的分离和检测.胆酸的线性范围为75~200 μg/mL, 检出限为0.1 μg/mL.线性方程为y=0.6054ρ-4.14991, r=0.953.回收率为100.9%, RSD(n=5)=2.1%. 相似文献
19.
氨基酸(Am ino acids,AA s)是组成生物大分子的基本单元,与人的健康状况有极其密切的关系.在医学和生命科学研究中,微量氨基酸的分离检测具有重要意义. 相似文献
20.
研制了一种适合普通厚度盖片的分析芯片的差示式非接触电导检测器。在芯片上制作分离通道和参比通道,并在独立的电极板上对应于两通道末端位置设置两对电极,分析芯片置于电极板上。信号发生器产生的高频信号分成两路,分别加至分离通道和参比通道对应的激发电极,两通道对应的接收电极的微弱信号经差示放大和整流。当组分经过分离通道电极间区域时,电导率与参比通道出现差异,获得检测信号。实验考察了激发频率、激发电压、电极间距等对检测性能的影响。在优化检测条件下,即检测频率100 kHz、检测电压10 V(Vp-p)、电极间距0.9 mm时,对K+的检出限达12μmol·L-1,相对标准偏差为1.1%,并成功用于Na+、K+离子的分离检测。该检测器适用于容易制作的普通厚度盖片的分析芯片的检测,且芯片与电极板相互独立,使用方便。 相似文献