首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Gas chromatography coupled to ion trap tandem mass spectrometry (CG-MS-MS) has been evaluated for the analysis of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (dl-PCBs) in vegetable oil samples containing different concentration levels (0.2-6 pg WHO-TEQ g(-1) for both PCDD/Fs and dl-PCBs) of the 29 toxic congeners of PCDD/F and dioxin-like PCBs. The effect of potential interfering compounds such as polychlorinated naphthalenes (PCNs), polychlorinated biphenyls (PCBs) and polychlorinated diphenylethers (PCDEs) on the quantification of mono-ortho PCBs has been investigated. In addition, the influence of the clean-up procedure on the final determination by CG-MS-MS was studied, showing that the quality of the results depends to a great extent on this analytical step. Quality parameters have been established and good precisions (CV: 3-19%) and low limits of detection for PCDD/Fs (0.04-0.20 pg g(-1) oil) and dl-PCBs (0.08-0.64 pg g(-1) oil) were obtained. The method was validated by a comparison of the CG-MS-MS results with those obtained by GC-HRMS.  相似文献   

2.
样品采用索氏抽提,抽提液依次经酸性硅胶床、多段混合硅胶柱和凝胶渗透色谱柱(GPC)净化后,用Florisil硅藻土柱分离出样品中的二噁英(PCDD/Fs)和类二噁英多氯联苯(dioxin-like PCBs),采用同位素稀释法和气相色谱/高分辨质谱联用仪(GC/HRMS)测定了其中的17个2,3,7,8-氯取代二噁英类化合物和12个类二噁英多氯联苯。结果表明,用该法分析二噁英和多氯联苯标准溶液,平行4次的分析结果为:RSD(PCDD/Fs)<8.9%,RSD(PCBs)<11.4%;回收率可达60%-105%。PCDD/Fs和PCBs的检出限分别为0.1-0.8 pg/g和0.05-0.6 pg/g。应用本方法成功测定了沉积物、淤泥、土壤和飞灰中的二噁英和类二噁英多氯联苯,并计算出它们的毒性当量。  相似文献   

3.
The chemical-activated luciferase expression (CALUX) assay is a reporter gene assay that detects dioxin-like compounds based on their ability to activate the aryl hydrocarbon receptor (AhR) and thus expression of the reporter gene. In this paper, the CALUX assay was examined for its application in the screening of polychlorinated dibenzo-p-dioxins (PCDDs), dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (dioxin-like PCBs) in retail fish. The sample extracts were cleaned up on a sulfuric acid-silica gel column followed by an activated carbon column, and the AhR activity of the separated PCDD/F and dioxin-like PCB fractions was determined using the assay. The quantitative limit for 2,3,7,8-tetrachlorodibenzo-p-dioxin (2,3,7,8-TCDD) was 0.98 pg ml(-1) (0.19 pg assay(-1) in the standard curve, corresponding to 0.16 pg g(-1) of CALUX-based toxic equivalency (2,3,7,8-TCDD equivalents) in the tested sample. Recovery tests in which dioxins were added to fish samples resulted in acceptable recoveries (77-117%). The CALUX assay performed well in the analysis of dioxins in fish samples and a comparative study revealed a strong correlation between the CALUX assay and high-resolution gas chromatography-high-resolution mass spectrometry analysis for the determination of PCDD/Fs (r = 0.89) and dioxin-like PCBs (r = 0.91) in retail fish (n = 22). These data revealed that the CALUX assay would be a useful screening method for PCDD/Fs and dioxin-like PCBs in retail fish.  相似文献   

4.
采用HRGC/HRMS和同位素稀释定量技术对样品中17种4~8个氯原子取代的二噁英和呋喃(PCDDs/Fs)与12种共平面多氯联苯(PCBs)定量分析。样品经索式抽提、FMSPowerPrep系统净化、浓缩,利用高分辨气相色谱/高分辨质谱联用仪的多离子检测方式,同位素稀释技术对样品中的目标化合物进行定性和定量。该方法的检出限为pg/g水平。13C同位素内标回收率范围为47%~100%。对3个CRM鱼样中17个PCDDs/Fs和4个PCBs的检测值均在标准定值允许误差范围内。对5个不同的实际样品鱼进行测定表明,样品的回收率在48%~100%之间,回收率的相对标准偏差小于20%;对同一样品进行定量检测的精密度测试结果表明,17种PCDDs/Fs浓度的RSD低于16%,12种PCBs浓度的RSD低于11%。本方法定量分析重现性良好。  相似文献   

5.
建立了加速溶剂萃取(ASE),酸性硅胶柱、复合硅胶柱及碱性氧化铝柱纯化分离,气相色谱-三重四极杆质谱测定土壤中二噁英/呋喃(PCDD/Fs)、多氯联苯(PCBs)、多氯萘(PCNs)的分析方法.选用正己烷-二氯甲烷(50∶50, V/V)作为ASE的提取溶剂,设定提取温度为120℃,加标回收实验表明本方法可行.用100 mL正己烷-二氯甲烷(95∶5, V/V)及50 mL正己烷-二氯甲烷(50∶50, V/V)依次淋洗碱性氧化铝柱,得到组分A(PCBs及PCNs)与组分B(PCDD/Fs),实现了PCDD/Fs与另外两种化合物的分离,排除了同系物间及其它杂质的干扰.使用同位素稀释-气相色谱三重四极杆质谱法(GC-MS/MS), 在选择反应监测(Selected reaction monitoring, SRM)模式下测定PCDD/Fs、PCBs和PCNs,3种化合物的仪器检出限(LOD)范围分别为0.04~0.25 μg/L, 0.10~0.20 μg/L和0.01~0.05 μg/L,目标物平均相对响应因子(RRF)的相对标准偏差(RSD)均小于13%.基质土加标实验中,3种化合物13C标记的同位素内标回收率的范围分别为50%~95%,51%~103%, 49%~74%.实际样品的分析结果表明,PCDD/Fs、PCBs及PCNs在土壤样品中的总含量范围分别为16.1~1148 pg/g、6.6~152.6 pg/g及10.9~99.5 pg/g,且样品测定结果与高分辨质谱测定结果相吻合.  相似文献   

6.
采用高分辨气相色谱/高分辨质谱(HRGC/HRMS)定量测定了底泥中的17种2,3,7,8位多氯代二噁英和呋喃(PCDD/Fs) ,并测定了四至八氯取代的二噁英和呋喃总量。样品经加速溶剂萃取,然后通过流体控制系统(FMS)自动过硅胶柱、氧化 铝柱和碳柱净化,最后浓缩。以HRGC/HRMS电压选择离子检测模式对样品中的PCDD/Fs进行了定性分析,采用同位素稀释 技术定量,该方法可精确定量到pg/g水平。结果表明该方法分析的17种二噁英和呋喃异构体的检出限可达0.1 pg/g。同 位素标准的回收率为49.8%~85.3%,样品中各异构体的回收率为93.2%~115.6%。该方法不但满足国际标准的要求,还大 大提高了分析速度,使分析周期从原来的2周缩短到2 d以内。  相似文献   

7.
Liu H  Zhang Q  Song M  Jiang G  Cai Z 《Talanta》2006,70(1):20-25
A comprehensive method was developed for quantitative analysis of polybrominated diphenyl ethers (PBDEs), polychlorinated biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins and dibenzo-furans (PCDD/Fs) in one single extract of environmental samples. The sample preparation procedure included two fractionation steps using silver nitrate silica chromatography to separate PBDEs from PCBs and PCDD/Fs and florisil column to separate PCBs from PCDD/Fs. Acidic silica, acidic alumina and gel permeation chromatography (GPC, for PCBs) or activated carbon column (for PCDD/Fs) were used for further clean-up. The sample extracts were analyzed by using high-resolution gas chromatography/high-resolution mass spectrometry. The entire method was validated from the analysis of mixed standards of PBDEs, PCBs and PCDD/Fs (n = 3); the analysis of certified reference biota (WMF-01). The method was applied for the analysis of 10 sediment samples collected from Haihe River and Dagu Drainage River in Tianjin City. No significant PBDEs pollution was found in the areas.  相似文献   

8.
Two gas chromatography-mass spectrometry systems equipped with an ion-trap mass analyzer working in tandem mode (GC-MS-MS) were evaluated for the determination of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and dioxin-like polychlorinated biphenyls (PCBs) in food samples. The performance of the two ion-trap instruments, which dispose of an external ion source (ThermoFinnigan GCQ/Polaris) and internal ionization (Varian Saturn 2,200), have been compared in terms of linearity, repeatability, limit of detection and long-term precision. Both instruments provided similar run-to-run and day-to-day precisions, ranging from 2% to 8% and between 2% and 13%, and instrumental limits of detection between 0.09 and 0.36 pg injected for PCDD/Fs and from 0.03 to 0.09 pg injected for dioxin-like PCBs. Although both instruments seem to be suitable for food analysis, only the use of external ionization allowed to achieve reliable results for PCDD/F determination at concentrations close to the maximum residue levels established by the EU for foods. Internal ionization provides high limits of detection (from 10- to 30-fold higher) and worse precision (RSD, 14-43%). In contrast, for dioxin-like PCBs both instruments allowed to obtain excellent results with precisions lower than 15%.  相似文献   

9.
The 2,3,7,8-substituted polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) are among the most toxic compounds known, and several sources of exposure to these chemicals should be monitored to protect human and environmental health. The current predominant method of analysis is too expensive and cumbersome, and comprehensive two-dimensional GC coupled to time-of-flight mass spectrometry (GC x GC--TOF-MS) has the potential to lower the costs and speed analysis of PCDD/Fs. In this study, GC x GC--TOF parameters were evaluated and optimized to yield complete separation of the 17 most important PCDD/F congeners from polychlorinated biphenyls (PCBs) interferences, and to attain the lowest detection limits. The optimization study entailed evaluation of oven temperature programs, column flow rates, ion source temperatures, electron ionization energy, data acquisition rate, and various GC x GC parameters, including modulation period, modulator temperature offset and hot pulse duration. After optimization, all 17 PCDD/Fs were separated in <60 min, and in particular, the critical pair of 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) and pentachlorobiphenyl congener CB126 did not co-elute chromatographically. Accurate identification and determination of all analytes could be made using their deconvoluted full mass spectra. In GC x GC, the modulation period and start time were the most important factors that affected sensitivity and selectivity for the analysis of the PCDD/Fs. The modulation period should be < or = 4s to preserve separations achieved in one-dimensional GC, and the modulation start time was important to achieve one large slice and two smaller symmetrical slices of TCDD to maximize its detection sensitivity. After optimization, the method could identify 0.25 pg of TCDD with standard injection from its full mass spectrum.  相似文献   

10.
2,3,7,8-Substituted polychlorinated dibenzo-p-dioxins/polychlorinated dibenzofurans (PCDD/Fs) and non-ortho-substituted polychlorinated biphenyls (PCBs) account for almost all of the total toxic equivalents (TEQ) in environmental samples. Activated carbon columns are used to fractionate the samples for GC-MS analysis or bioassay. Micropore-free surface-activated carbon is highly selective for PCDD/Fs and non-ortho-PCBs and can improve the conventional activated carbon column clean-up. Along with sulfuric acid-coated diatomaceous earth columns, micropore-free surface-activated carbon provides a rapid, robust, and high-throughput sample preparation method for PCDD/Fs and non-ortho-PCBs analysis.  相似文献   

11.
There is a need for cost-efficient alternatives to gas chromatography (GC)–high-resolution mass spectrometry (HRMS) for the analysis of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and dioxin-like polychlorinated biphenyls (PCBs) in food and feed. Comprehensive two-dimensional GC–micro electron capture detection (GC×GC-μECD) was tested and all relevant (according to the World Health Organisation, WHO) PCDD/Fs and PCBs could be separated when using a DB-XLB/LC-50 column combination. Validation tests by two laboratories showed that detectability, repeatability, reproducibility and accuracy of GC×GC-μECD are all statistically consistent with GC-HRMS results. A limit of detection of 0.5 pg WHO PCDD/F tetrachlorodibenzo-p-dioxin equivalency concentration per gram of fish oil was established. The reproducibility was less than 10%, which is below the recommended EU value for reference methods (less than 15%). Injections of vegetable oil extracts spiked with PCBs, polychlorinated naphthalenes and diphenyl ethers at concentrations of 200 ng/g showed no significant impact on the dioxin results, confirming in that way the robustness of the method. The use of GC×GC-μECD as a routine method for food and feed analysis is therefore recommended. However, the data evaluation of low dioxin concentrations is still laborious owing to the need for manual integration. This makes the overall analysis costs higher than those of GC-HRMS. Further developments of software are needed (and expected) to reduce the data evaluation time. Combination of the current method with pressurised liquid extraction with in-cell cleanup will result in further reduction of analysis costs. Electronic supplementary material The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

12.
2014年1月在杭州市选择5个点位采集大气颗粒物PM2.5样品,采用同位素稀释高分辨气相色谱/高分辨质谱测定PM2.5中的二恶英(PCDD/Fs)和多氯联苯(PCBs),对PM2.5的污染状况以及PM2.5中PCDD/Fs和PCBs的污染水平及分布特征进行了研究。PM2.5的质量浓度范围为85~168 μg/m3,PM2.5污染较重,但与2004年同期相比明显降低。PM2.5中PCDD/Fs的毒性当量(TEQ)为0.277~0.488 pg I-TEQ/m3,明显高于2004年同期采集样品。颗粒物中PCDD/Fs以八氯代二苯并-对-二恶英(OCDD)为主,毒性当量主要贡献者为2,3,4,7,8-五氯代二苯并呋喃(2,3,4,7,8-PeCDF)。PM2.5中PCBs的质量浓度范围为2.9~8.1 pg/m3,二恶英类多氯联苯(DL-PCBs)的毒性当量范围为2.6~6.1 fg WHO-TEQ/m3,污染较低。PCBs在颗粒物中分布以PCB-28为主,但对毒性当量贡献最大的为PCB-126。PCDD/Fs和PCBs的气-固分配特征表现为PCDD/Fs主要分布于颗粒物中,而PCBs主要分布于气相中。  相似文献   

13.
王丽  李书书  张展  王守林  李磊 《色谱》2015,33(8):878-884
建立了气相色谱-负化学电离源质谱(GC-NCI-MS)同时测定鱼油中16种多氯联苯(PCBs)的方法。鱼油样品经正己烷提取和浓硫酸净化,在选择离子监测模式下进行GC-NCI-MS检测。所检测的PCBs在0.01~10 μg/L范围内呈现良好的线性关系(r>0.99),定量限(S/N=10)在3~67 pg/g之间。基质加标回收率为62.3%~121.8%,相对标准偏差(n=3)≤12%。相比传统的多种填料固相萃取前处理法,本方法样品处理简单快速,有机溶剂使用量少,具有较好的抗基质干扰能力和较高的灵敏度,适用于鱼油中痕量共平面多氯联苯及常见指示性多氯联苯等的同时检测。  相似文献   

14.
A method was developed on a gas chromatograph coupled to a triple quadrupole mass spectrometer(GC-MS/MS) for trace level determination of polychlorinated dibenzo-p-dioxins/dibenzofurans(PCDD/Fs) and dioxin-like polychlorinated biphenyls(DL-PCBs) in food and feed. The results demonstrated good sensitivity and repeatability for PCDD/Fs and DL-PCBs at an extremely low level(10 pg mL~(-1) for 2,3,7,8-TCDD/F), as well as wide linear response of over 3 or 4 orders of magnitude in concentration ranges; 0.5–200 ng mL~(-1) for PeCDD/F and 0.2–2000 ng mL~(-1) for DL-PCBs. The method detection limits for PCDD/Fs and DL-PCBs were in the range from 0.018–0.17 pg g~(-1) to 0.13–0.36 pg g~(-1), respectively. The performance of the GC-MS/MS for food and feed sample analysis showed high precision and accuracy compared to the high resolution gas chromatograph/high resolution mass spectrometer. The results indicated the feasibility of GC-MS/MS as a confirmatory method for the measurement of PCDD/Fs and DL-PCBs in food and feed as required by European Union legislation.  相似文献   

15.
McAlister DR  Fern MJ  Allen RL 《Talanta》2008,74(4):992-997
A method for the estimation of polychlorinated dibenzo-p-dioxin and furan (PCCD/F) toxicity equivalent quotient (TEQ) of soil and sediment matrices is described. The method includes extraction, isolation of the PCDD/Fs from interfering compounds, such as polychlorinated biphenyls (PCBs) and polycyclic aromatic hydrocarbons (PAHs), and measurement of PCDD/F using the PROCEPT aryl hydrocarbon (AhR) receptor based polymerase chain reaction (PCR) assay. The values obtained using the PROCEPT assay correlate well with reference TEQ values generated from gas chromatography-high resolution mass spectrometry (GC-HRMS), with a linearity coefficient (R(2)) of 0.94. Applied in a screening mode at 50pg/g PCDD/F TEQ, the PROCEPT assay yielded five false positive results (2.6%) and no false negative results for 196 analyses of spiked soils and environmental samples obtained from US EPA Superfund sites.  相似文献   

16.
张磊  李敬光  吴永宁  赵云峰 《色谱》2007,25(6):887-892
采用索氏提取及自动净化处理系统对乳品进行提取和净化,在高分辨气相色谱-高分辨双聚焦质谱仪(HRGC/HRMS)上进行定性和定量检测。在3种不同残留水平的奶粉样品中,17种多氯代二苯并-对二恶英和多氯代二苯并呋喃(PCDD/Fs)的测定结果与给定值具有很好的一致性,且所有具有保证值的二恶英同系物测定结果的相对标准偏差(RSD)均小于20%;12种共平面多氯联苯(PCBs)测定结果的RSD均在15%以内,内标物的回收率为44%~133%,完全符合国际标准方法的要求。母乳样品的国际考核结果表明本方法在不同实验室间具有良好的准确度和精密度。本方法定量准确可靠,适用于乳品中二恶英及共平面PCBs的同时检测。  相似文献   

17.
Environmental chemists have been challenged for over 30 years to analyse complex mixtures of halogenated organic pollutants like polychlorinated biphenyls (PCBs), polychlorinated alkanes (PCAs), polybrominated diphenyl ethers (PBDEs) and polychlorinated dibenzo-p-dioxins and polychlorinated furans (PCDD/Fs). Gas chromatography (GC) often proved to be the method of choice because of its high resolution. The recent developments in the field of comprehensive two-dimensional GC (GCxGC) show that this technique can provide much more information than conventional (single-column) GC. Large volume injection (e.g. by programmed temperature vaporiser, or on-column injection) can be employed for the injection of tens of microliters of sample extract, in that way substantially improving the detection limits. Electron-capture detection (ECD) is a sensitive detection method but unambiguous identification is not possible and misidentification easily occurs. Mass spectrometric (MS) detection substantially improves the identification and the better the resolution (as with MS/MS, time-of-flight (TOF) MS and high-resolution (HR)MS), the lower the chances of misidentification are. Unfortunately, this comes only with substantially higher investments and maintenance costs. Co-extracted lipids, sulphur and other interferences can disturb the GC separation and detection leading to unreliable results. Extraction, and more so, sample clean-up and fractionation, are crucial steps prior to the GC analysis of these pollutants. Recent developments in sample extraction and clean-up show that selective pressurised liquid extraction (PLE) is an effective and efficient extraction and clean-up technique that enables processing of multiple samples in less than 1h. Quality assurance tools such as interlaboratory studies and reference materials are very well established for PCDD/Fs and PCBs but the improvement of that infrastructure is needed for brominated flame retardants, PCAs and toxaphene.  相似文献   

18.
Instrumental methods based on gas chromatography coupled to mass spectrometry (GC–MS) have been developed and compared using two different MS ionisation modes, electron impact (EI) and electron capture negative ionisation (ECNI), for the fast, quantitative and simultaneous determination of polychlorinated biphenyls (PCBs) and their main metabolites (hydroxylated PCBs, OH-PCBs, and methyl sulfone PCBs, MeSO2-PCBs). Parameters affecting chromatographic separation and MS detection were evaluated in order to achieve the highest selectivity and sensitivity for both operation modes. The analytical characteristics of the developed methods were studied and compared in terms of linear range, limits of detection (LODs), limits of quantification (LOQs), and instrumental precision (repeatability and intermediate precision). Both ionisation methods showed similar precision, being relative standard deviations (RSD, %) lower than 9% and 14% for repeatability and intermediate precision, respectively. However, better LODs (from 0.01 to 0.14 pg injected for the three families of congeners studied) were achieved using ECNI-MS as ionisation mode. The suitability of the developed method was demonstrated through their application to fish liver oil samples.  相似文献   

19.
The development of a unique analytical method for the determination of five classes of persistent organic pollutants (POPs) in atmospheric gas and the particle phase through gas chromatography coupled to high-resolution mass spectrometry is presented. Every step of the pre-analytical and analytical optimization process is described. Great effort was put into simplifying the traditional techniques, with reference to EPA and literature methods. Automated instruments were used for sample extraction and cleanup in order to enhance repeatability and reduce contamination risks. Unlike most common approaches, no separation of the analytes was performed before the GC analysis in order to avoid sample fractionation and to save time and materials. This allowed low instrumental and method detection limits (pg to sub-pg) to be achieved. Accuracy and precision were tested by fortifying the matrix and analysing standard reference materials (NIST SRM 1649b Urban Dust and 2585 Organic Contaminants in House Dust). The method was applied to five samples from Terra Nova Bay, Antarctica. Concentrations of polychlorinated dibenzo-p-dioxins and furans (PCDD/Fs), polychlorinated biphenyls (PCBs), polychlorinated naphthalenes (PCNs), polybrominated diphenyl ethers (PBDEs) and polycyclic aromatic hydrocarbons (PAHs) are presented. Lighter compounds dominate the distribution and are mainly present in the gaseous phase. The observed pattern may be attributable to long-range transport. Results are in general agreement with literature data, where available.  相似文献   

20.
Selective pressurized liquid extraction (PLE) of polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDD/Fs) and dioxin-like polychlorinated biphenyls (dl-PCBs) from various food and feed samples was performed with a selective PLE method previously developed for bulk PCBs. The method utilizes sulfuric acid impregnated silica inside the extraction cell to oxidize coextracted fat. Extractions were performed at 100 degrees C with n-heptane for 5 min in two cycles. Data obtained by selective PLE combined with gas chromatography/high-resolution mass spectrometry (GC-HRMS) were compared to concentrations derived from reference laboratories applying conventional sample preparation and GC-HRMS. Experiments performed on spiked vegetable oil, naturally contaminated crude fish oil and oil containing compound feed samples showed good results for these relatively simple matrices. The accuracy was generally +/-20% as compared to spiked levels or to values obtained by the reference laboratories. The precision, measured as the relative standard deviation (RSD) for 2,3,7,8-tetrachlorodibenzo-p-dioxin toxic equivalency values (TEQs), was below 10% in all cases. The method was also tested on naturally contaminated herring tissue, chicken tissue, pork tissue and sepiolitic clay, which all caused some trouble. It was observed that sufficient amounts of sodium sulfate should be used for dehydration of tissue samples and additionally, the cells should not be packed too dense in order to avoid suppressed extraction efficiency. Once this was attended to, satisfactory data could be obtained, except for sepiolithic clay. This study demonstrates that selective PLE can be applied with success to a number of food and feed matrices in analysis of PCDD/Fs and dl-PCBs. Since the fat removal step is on-line, the selective PLE method will reduce time and solvent consumption for sample preparation as compared to traditional clean-up.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号