首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The potential of a linear e + e- collider operated at a centre-of-mass energy of 350 GeV is studied for the measurement of the Higgs boson mass. An integrated luminosity of 500 fb-1 is assumed. For Higgs boson masses of 120, 150 and 180 GeV the uncertainty on the Higgs boson mass measurement is estimated to be 40, 65 and 70 MeV, respectively. The effects of beam related systematics, namely a bias in the beam energy measurement, the beam energy spread and the luminosity spectrum due to beamstrahlung, on the precision of the Higgs boson mass measurement are investigated. In order to keep the systematic uncertainty on the Higgs boson mass well below the level of the statistical error, the beam energy measurement must be controlled with a relative precision better than 10-4. Received: 30 May 2005, Revised: 6 July 2005, Published online: 6 October 2005  相似文献   

2.
Knowledge of the centre-of-mass energy at LEP2 is of primary importance to set the absolute energy scale for the measurement of the W-boson mass. The beam energy above 80 GeV is derived from continuous measurements of the magnetic bending field by 16 NMR probes situated in a number of the LEP dipoles. The relationship between the fields measured by the probes and the beam energy is calibrated against precise measurements of the average beam energy between 41 and 55 GeV made using the resonant depolarisation technique. The linearity of the relationship is tested by comparing the fields measured by the probes with the total bending field measured by a flux loop. This test results in the largest contribution to the systematic uncertainty. Several further corrections are applied to derive the centre-of-mass energies at each interaction point. In addition, the centre-of-mass energy spread is evaluated. The beam energy has been determined with a precision of 25 MeV for the data taken in 1997, corresponding to a relative precision of . This is small in comparison to the present uncertainty on the W mass measurement at LEP. However, the ultimate statistical precision on the W mass with the full LEP2 data sample should be around 25 MeV, and a smaller uncertainty on the beam energy is desirable. Prospects for improvements are outlined. Received: 14 December 1998 / Published online: 3 November 1999  相似文献   

3.
针对直线感应电子加速器中的束流特点,设计了一种在线式电子束能量测量方法。该方法使用分析磁铁和束位置探测器对电子束团切片平均能量进行测量,避免了束团取样带来的误差及测量过程对束流的影响,可以实现电子能量的在线测量。使用该方法对某强流直线感应电子加速器的电子束团能量进行了测量,获得了电子束团切片平均能量随时间变化的曲线,能量测量不确定度为0.177 MeV,能散度测量不确定度为0.39%。  相似文献   

4.
光束质量因子测量的不确定度分析   总被引:1,自引:0,他引:1  
 介绍了激光光束质量因子的定义以及测量原理,分析了光束质量因子的数学模型中各个量的不确定度来源以及评定方法,并以实验数据为基础,对具体的实验数据进行了分析计算。提出了减小激光光束质量因子测量不确定度的途径,包括统一激光束直径的确认方法,保证测量条件的稳定以及提高光束质量测量系统的测量精度等。  相似文献   

5.
中国散裂中子源反角白光中子束流参数的初步测量   总被引:2,自引:0,他引:2       下载免费PDF全文
鲍杰  陈永浩  张显鹏  栾广源  任杰  王琦  阮锡超  张凯  安琪  白怀勇  曹平  陈琪萍  程品晶  崔增琪  樊瑞睿  封常青  顾旻皓  郭凤琴  韩长材  韩子杰  贺国珠  何泳成  何越峰  黄翰雄  黄蔚玲  黄锡汝  季筱路  吉旭阳  江浩雨  蒋伟  敬罕涛  康玲  康明涛  兰长林  李波  李论  李强  李晓  李阳  李样  刘荣  刘树彬  刘星言  马应林  宁常军  聂阳波  齐斌斌  宋朝晖  孙虹  孙晓阳  孙志嘉  谭志新  唐洪庆  唐靖宇  王鹏程  王涛峰  王艳凤  王朝辉  王征  文杰  温中伟  吴青彪  吴晓光  吴煊  解立坤  羊奕伟  杨毅  易晗  于莉  余滔  于永积  张国辉  张旌  张林浩  张利英  张清民  张奇伟  张玉亮  张志永  赵映潭  周良  周祖英  朱丹阳  朱科军  朱鹏 《物理学报》2019,68(8):80101-080101
中国散裂中子源(CSNS)已于2018年5月建设完工,随后进行了试运行.其中的反角白光中子束线(Back-n)可用于中子核数据测量、中子物理研究和核技术应用等多方面的实验.本文报道对该中子束的品质参数测量实验过程以及最终实验结果.实验主要采用中子飞行时间法,利用~(235)U,~(238)U裂变室和~6Li-Si探测器测量了中子能谱和中子注量率,又利用闪烁体-互补金属氧化物半导体探测系统测量了中子束斑的剖面,得到了该束线的初步实验测量结果.其中白光中子的全能谱测量范围eV—100 MeV,给出了不确定度分析;给出了中子注量率两个实验厅位置的满功率值;给出了白光中子在直径60 mm情况下的全能区束斑.通过与模拟结果的比较探讨了以上结果的合理性,并提出了改进计划.这些实验结果为以后该束线的核数据测量和探测器标定实验奠定了基础.  相似文献   

6.
The determination of the centre-of-mass energies for all LEP 2 running is presented. Accurate knowledge of these energies is of primary importance to set the absolute energy scale for the measurement of the W boson mass. The beam energy between 80 and 104 GeV is derived from continuous measurements of the magnetic bending field by 16 NMR probes situated in a number of the LEP dipoles. The relationship between the fields measured by the probes and the beam energy is defined in the NMR model, which is calibrated against precise measurements of the average beam energy between 41 and 61 GeV made using the resonant depolarisation technique. The validity of the NMR model is verified by three independent methods: the flux-loop, which is sensitive to the bending field of all the dipoles of LEP; the spectrometer, which determines the energy through measurements of the deflection of the beam in a magnet of known integrated field; and an analysis of the variation of the synchrotron tune with the total RF voltage. To obtain the centre-of-mass energies, corrections are then applied to account for sources of bending field external to the dipoles, and variations in the local beam energy at each interaction point. The relative error on the centre-of-mass energy determination for the majority of LEP 2 running is 1.2 x 10-4, which is sufficiently precise so as not to introduce a dominant uncertainty on the W mass measurement. Received: 4 August 2004, Revised: 15 December 2004, Published online: 21 January 2005  相似文献   

7.
合肥光源单束团下束团长度和能散的测量   总被引:6,自引:1,他引:5       下载免费PDF全文
根据同步光与储存环中的束流信号具有相同的时间结构的原理,测量同步光脉冲的半高全宽值可以计算出束团的长度。根据合肥光源的特点和实际需要,选择快速光电接收器搭配高速高带宽示波器作为在线测量束团长度和纵向分布等的主要手段。对单束团模式下束团长度随流强和高频腔腔压的变化趋势进行了测量。测量结果表明:束团长度与腔压的0.3次方成反比,比理论值0.5小;而束团长度随流强的增长率为2.0 ps/mA。通过测量纵向量子寿命进行了能散随流强变化的间接测量,结果表明,束团的拉伸是能散变化和势阱效应共同作用的结果。  相似文献   

8.
A high-precision Penning trap mass measurement of the exotic 8He nuclide (T(1/2)=119 ms) has been carried out resulting in a reduction of the uncertainty of the halo binding energy by over an order of magnitude. The new mass, determined with a relative uncertainty of 9.2 x 10(-8) (deltam=690 eV) is 13 keV less bound than the previously accepted value. The mass measurement is of great relevance for the recent charge-radius measurement of 8He [P. Mueller, Phys. Rev. Lett. 99, 252501 (2007).10.1103/PhysRevLett.99.252501]. The 8He mass is the first result from the newly-commissioned Penning trap: TITAN (TRIUMF's Ion Trap for Atomic and Nuclear science) at the ISAC (Isotope Separator and Accelerator) radioactive beam facility at TRIUMF.  相似文献   

9.
The neutron decay spectrometera SPECT has been built to perform a precise measurement of the proton spectrum shape in the decay of free neutrons. Such a measurement allows a determination of the neutrino electron angular-correlation coefficienta . The present best experiments have an uncertainty of Δa/a = 5% and since the seventies there is no substantial improvement. Witha SPECT, we aim for an uncertainty which is lower by more than an order of magnitude, thus enabling us to perform several precise tests of the Standard Model. In our first beam time at the particle physics beam MEPHISTO at the Forschungsneutronenquelle Heinz Maier-Leibnitz, we studied the properties of the spectrometer. The most serious problem turned out to be the situation- and time-dependent behavior of the background. From the data sets from this beam time in which a background problem was not obvious, we could extract a value ofa = - 0.1151±0.0040stat , but we could not quantify the background uncertainty. We show ways to deal with the background and other problems for future beam times.  相似文献   

10.
利用北京同步辐射3B3中能束线, 在国内首次实现了XRD X射线探测器灵敏度在2—6keV能区的标定, 灵敏度的不确定度小于7%. 另外中能束线的应用还极大地提高了滤片厚度的标定精度, 其厚度的不确定度小于3.6%.  相似文献   

11.
The Shanghai Synchrotron Radiation Facility (SSRF)booster ring, a full energy injector for the storage ring, is deigned to accelerate the electron beam energy from 150MeV to 3.5GeV that demands high extraction efficiency at the extraction energy with low beam loss rate when electrons are ramping. Closed orbit distortion (COD) caused by bending magnet field uniformity errors which affects the machine performance harmfully could be effectively reduced by bending magnet location sorting. Considering the affections of random errors in measurement, both ideal sorting and realistic sorting are studied based on measured bending magnet field uniformity errors and one reasonable combination of bending magnets which can reduce the horizontal COD by a factor of 5 is given as the final installation sequence of the booster bending magnets in this paper.  相似文献   

12.
The Shanghai Synchrotron Radiation Facility(SSRF)booster ring,a full energy injector for the storage ring,is deigned to accelerate the electron beam energy from 150MeV to 3.5GeV that demands high extraction efficiency at the extraction energy with low beam loss rate when electrons are ramping.Closed orbit distortion(COD)caused by bending magnet field uniformity errors which affects the machine performance harmfully could be effectively reduced by bending magnet location sorting.Considering the affections of random errors in measurement,both ideal sorting and realistic sorting are studied based on measured bending magnet field uniformity errors and one reasonable combination of bending magnets which can reduce the horizontal COD by a factor of 5is given as the final installation sequence of the booster bending magnets in this paper.  相似文献   

13.
A possibility of precise measurement of the electron beam energy using absorption of radiation by electrons in a homogeneous magnetic field for electrons of high energy in the range up to a few hundred GeV, was considered earlier. In this paper, with the purpose of experimental checking of this method in the range of several tens MeV of electrons energies, a possibility of measurement of absolute energy of the electron beam with a relative accuracy up to 10?4, is considered. We take into account influence of the laser beam diffraction, of the spread of electrons over energies, and of the length of formation of radiation absorption in the process of electron beam energy measurement. The laser wavelength and the length of the magnet are chosen depending on the length of photon absorption formation. It is found that the kinematical restrictions on the photon absorption process lead to the selection in angles of propagation of photons, which can be absorbed by the beam electrons. It is shown that parameters of the electron beam will noticeably not vary during the measurement of the energy.  相似文献   

14.
Study of high precise measurement of large diameters by a dual frequency laser interferometer¥FENGQibo(Dep.ofPhysics,Northern...  相似文献   

15.
刘运传  周燕萍  王雪蓉  孟祥艳  段剑  郑会保 《物理学报》2013,62(16):162901-162901
采用金属有机化合物气相淀积法在(0001)取向的蓝宝石衬底上生长一层 大约20 nm厚的AlN缓冲层, 在缓冲层上生长大约2 μm厚、 晶体质量良好的AlxGa1-xN外延层, 通过深紫外光致发光法测量发光峰的能量Eg 判断外延层中铝含量的均匀性, 取样品均匀性良好的氮铝镓外延片进行卢瑟福背散射(RBS)实验, 通过两个高能离子束实验室分别进行RBS随机谱分析, 每个实验室测量六个样品, 由分析软件拟合随机谱获得外延层中的xAl. 并对样品的均匀性、堆积校准、计数统计、散射角、离子束能量与阻止截面 等影响测量结果准确性的不确定度来源进行分析. 结果表明, 采用入射离子4He, 能量为2000 keV, 散射角为165° 时, 氮铝镓外延片中铝含量(x=0.8) 的测量不确定度为2.0%, 包含扩展因子k=2. 关键词: 氮铝镓 卢瑟福背散射 测量不确定度 金属有机化合物气相淀积法  相似文献   

16.
实验研究了HIRFL-CSRm中电子冷却装置对C6+,Ar15+两种束流寿命的影响。首先,通过对比实验的测量确定电子冷却可以有效提高束流寿命;其次,探究了电子冷却装置中的各项参数(主要是电子束密度分布、流强、能量、绝热展开因子)是如何影响束流寿命的,通过改变电子束参数,测量束流寿命的变化趋势和规律,并且结合电子冷却相关理论对实验结果给予解释,最终通过实验优化和确定最佳的冷却装置参数,使束流在HIRFL-CSRm上获得了较高的寿命,从而提高HIRFL-CSRm束流累积过程中的流强增益。  相似文献   

17.
The accuracy of an interference experiment is known to depend on the interference imaging conditions. The effect of the Gaussian inhomogeneity of laser beam intensity on the wave-front reconstruction uncertainty is investigated. The effective size of the illuminating laser beam is shown to influence the measurement uncertainty. The effect is more pronounced in evaluation of the interferograms with a small number of fringes. __________ Translated from Izvestiya Vysshikh Uchebnykh Zavedenii, Fizika, No. 5, pp. 51–55, May, 2005.  相似文献   

18.
彭晓世  王峰  徐涛  刘慎业  魏惠月  刘永刚  梅雨  陈铭 《光学学报》2012,32(8):812003-100
为了测量激光与等离子体相互作用产生的散射光份额,获得黑腔耦合效率实验中的激光注入率,研制了基于神光Ⅲ原型装置的全孔径背向散射测量系统。该系统利用聚焦透镜收集散射光,通过离轴抛物面镜进行缩束,并采用二向色镜将散射光分为两个支路后分别进行受激布里渊散射和受激拉曼散射光的能量、时间过程和光谱测量。实验测量了有、无束匀滑条件下的散射光份额。结果表明,在当前实验条件下,通过束匀滑可有效降低散射光份额,提高激光注入率。  相似文献   

19.
光学渡越辐射测量中能量分辨精度分析   总被引:4,自引:4,他引:0  
 基于光学渡越辐射原理的用于高能强流电子束束流参数在线测量及诊断系统,具有时间响应快、分辨率高等特点,可以测量电子束的束剖面、发散角、能量等多个参数。分析了测量系统的结构参数(包括了透镜的焦距、成像面位置、CCD像元尺寸)对电子束能量测量精度的影响,并在理论上模拟了电子束的发散角的影响。还根据系统数据的特点,阐述了数据噪声对能量测量结果精度的影响,指出了光学渡越辐射测量中电子束能量分辨精度受到多种因素的影响,需要在数据处理时考虑修正。  相似文献   

20.
安超凡  谢修璀  蒲越虎 《强激光与粒子束》2021,33(11):114001-1-114001-9
为了验证国产质子注入器的参数是否满足需求,注入器团队设计了束流测量系统用于测量国产质子直线注入器束流的流强、发射度、能量以及能散等关键指标。此测量系统包含了采用变聚焦法测量发散度、采用分析磁铁测量束流能量和能散的主要功能。利用束流输运线设计软件Tracewin(版本2.11.4.1)进行了系统束线的物理设计,对束测系统测量质子束流的发散度和能量的精度进行了模拟计算。由于经过RFQ-(APF)DTL加速后的粒子束团为“拖尾”的非理想粒子束团,需要针对非理想束团对束测系统测量发射度和能量产生的影响进行分析。通过对模拟计算结果的分析,发现相对于测量理想粒子束团的结果非理想粒子束团对束测系统测量发射度精度影响较大;非理想粒子束团对束测系统测量能量精度影响较小。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号