首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 734 毫秒
1.
矿石样品铂、钯、铑和铱经铅试金富集,所得金属合粒用硝酸-盐酸溶解,用石墨炉原子吸收光谱法测定矿石样品中铂、钯、铑和铱的含量。在优化的石墨炉工作条件下测得:铂的质量浓度在20~150μg.L-1、钯在15~120μg.L-1、铑和铱在6~100μg.L-1范围内与其吸光度呈线性关系,检出限(3s/k)依次为4.6,4.0,1.5,1.5μg.L-1。方法用于分析了2种矿石国家标准物质(GBW 07341、GBW 07342),测定结果与认定值相符。方法的回收率在87.6%~105.5%之间。测定值的日内和日间相对标准偏差(n=7)分别在2.8%~3.6%和3.5%~4.7%之间。  相似文献   

2.
Radiometric methods of determination of platium and palladium (0.1 to 5% of Pt and 0.1 to 2% of Pd), gold and indium (0.01 to 1% of Au and 1 to 4 g In/l) and of platinum and rhodium (0.1 to 9% of Pt and 0.05 to 1% of Rh) in aqueous solution has been worked out. A suitable measuring device has been designed and constructed. The methods are based on the measurement of characteristic radiation of the Lα line for gold and platinum and of the K-series for indium, palladium and rhodium, as well as on the measurement of scattered radiation from a238Pu source. The r.m.s. error of the determination varies from 0.01 to 0.10% of Pt, 0.002 to 0.01% of Au and 0.01 to 0.15% of Pd depending on the concentration. In the case of Rh and In the errors are 0.008% and 0.04 g In/l, respectively.  相似文献   

3.
The integrated scheme described for the determination of five noble metals, combines solvent extraction procedures with atomic absorption spectrometric finishes. It comprises an initial extraction of gold, a simultaneous extraction of platinum and palladium as iodides, and a subsequent simultaneous extraction and preconcentration of rhodium and indium as their 2-mercaptobenzothiazol? complexes. The same solvent, methyl isobutyl ketone, and the same acidity, 6 M, are used throughout the extractions. As large amounts of platinum and palladium can be extracted quantitatively as readily as small amounts, the proposed scheme is applicable to a wide range of platiniferous materials, particularly to those with extremely high Pt + Pd to Rh + Ir ratios.  相似文献   

4.
A flow injection online displacement solid-phase extraction (DSPE) via magnetic immobilization of mercapto-functionalized magnetite microspheres onto the inner walls of a knotted reactor (KR) coupled with inductively coupled plasma mass spectrometry was developed for selective preconcentration and determination of trace noble metals (Ru, Rh, Pd, Pt, Ir and Au) in complex matrices. Online DSPE of 2.7 mL aqueous solution gave the enhancement factors of 32-46 for the six noble metals in comparison with direct nebulization of aqueous sample solution, and the detection limits (3 s) of 2.1 ng L(-1) for Ru, 1.9 ng L(-1) for Rh, 2.5 ng L(-1) for Pd, 1.8 ng L(-1) for Ir, 1.9 ng L(-1) for Pt and 1.7 ng L(-1) for Au. The sample throughput of the developed method was about 20 samples h(-1), and the relative standard deviation for eleven replicate determinations of the noble metals at the 30 ng L(-1) level ranged from 1.2% to 2.1%. The recoveries of Ru, Rh, Pd, Pt, Ir and Au still maintained 90% even after successive 140 cycles of DSPE. The developed method was successfully applied to selective determination of trace Ru, Rh, Pd, Pt, Ir and Au in complex matrices.  相似文献   

5.
A sensitive and selective microwave-assisted solid phase extraction procedure coupled to inductively coupled plasma-mass spectrometry (ICP-MS) is proposed for palladium (Pd) and platinum (Pt) quantification in environmental and biological samples. Pd and Pt were quantitatively retained on commercial thioureido propyl functionalised silica gel packed inside a home-made glass microcolumn, and later eluted with 0.5% thiourea solution under microwave irradiation, followed by ICP-MS determination. The main variables affecting the procedural stages (i.e., sorption and desorption) and ICP-MS determination were optimised. The best conditions found were: (a) sorption: sample acidity, 1?M HCl; sample flow rate, 3?mL?min?1; (b) desorption: microwave radiation, power 800?W; eluent concentration, 0.5% thiourea; eluent flow rate, 0.5?mL?min?1; (c) ICP-MS determination: nebuliser feeding, free aspiration (0.3?mL?min?1); internal standard, Rh (5?µg?L?1). Analyte recoveries were higher than 90% and concentration factors up to 90 and 92 were achieved for Pd and Pt, respectively. Depending on the conditions, the methodological limits of detection were down to 0.2?ng?L?1 for both analytes and repeatability, expressed as RSD%, varied between 1.3 and 11.0%. A method selectivity evaluation showed that most of the ICP-MS interferents were either quantitatively separated or more than 86% eliminated, except for Cu (elimination efficiency around 30%). Finally, the method was successfully used to determine Pd in certified reference materials (i.e. human urine and serum) and Pd and Pt in PM10 airborne particulate matter fractions.  相似文献   

6.
铂族元素在环境和生物样品中的积累及毒性研究进展   总被引:2,自引:0,他引:2  
由汽车尾气净化器的安装使用而导致环境中的铂族元素尤其是铂、钯、铑的含量逐渐增长,铂族元素对于生活和生态环境的影响也越来越多受到关注.论述了汽车三元催化剂中铂族元素毒性、铂族元素在环境和生物样品的分布、环境样品中铂族元素的消解、测定方法以及干扰处理方法,总结了多国测定结果并对结果进行了综合评述.  相似文献   

7.
Platinum (Pt), palladium (Pd), ruthenium (Ru), rhodium (Rh), iridium (Ir), and osmiun (Os) are platinum-group elements with similar physic-chemical properties, and have important applications in geochemistry and environmental chemistry. However, due to their low abundance and inhomogeneous distribution in natural ores as well as the nugget effect, the accurate determination of the platinum-group elements has been a challenge for geological analysis. In this work, self-prepared and purified sodium carbonate (NiCO3) instead of commercial nickel oxide (NiO) was used as the fire assay collector in order to greatly reduce the reagent blank and method detection limits. In addition, the fuming time of HClO4 was strictly controlled at 10?min and a high sensitive method was developed for the simultaneous determination of ultra-trace Pt, Pd, Ru, Rh, and Ir in minerals by inductively coupled plasma-mass spectrometry (ICP-MS) following preconcentration with the nickel sulfide fire assay. Under the optimized conditions, the linear ranges of Pt, Pd, Ru, Rh, and Ir were between 0 and 100?ng mL?1, with correlation coefficients exceeding 0.9997. The detection limits were 0.015, 0.056, 0.014, 0.004, 0.012?ng mL?1 (for 10?g sample) for Pt, Pd, Ru, Rh and Ir, respectively. The developed method was successfully applied to analyze Chinese Certified Reference Materials (CRMs) GBW07288, GBW07289, GBW07290, GBW07291, GBW07292, GBW07293, GBW07294, GBW07101, GBW07102 and GBW07201 and the determined values were in good agreement with the certified values. The relative standard deviations (n?=?5) of Pt, Pd, Ru, Rh and Ir were between 3.42% and 6.87% for the determination of GBW07291.  相似文献   

8.
The high economic value of catalysts containing the platinum group elements platinum, rhodium and palladium as active components causes the need to be able to measure the precious metal loading with small uncertainty and to have suitable certified reference materials fulfilling high demands on the quality of the certified values. In European Reference Material ERM®-EB504, a used cordierite-based car catalyst material, mass fractions of platinum, palladium and rhodium were certified. The raw material was milled, homogenised and annealed before analysis. Seventeen laboratories experienced in precious metals analysis participated in the certification interlaboratory comparison, most of them analysing with inductively coupled plasma optical emission spectrometry using different sample pretreatment techniques. Homogeneity testing was carried out using X-ray fluorescence spectrometry. The certified mass fractions of Pt, Pd and Rh and their expanded uncertainties (k = 2) in ERM®-EB504 are (1777 ± 15), (279 ± 6) and (338 ± 4) mg/kg respectively.  相似文献   

9.
A number of aliphatic mono- and triamines have been investigated as potential reagents for solid phase extraction of Rh, Pd and Pt. Platinum group metals are recovered from hydrochloric acid solutions as ionic associates of their chloride complexes with protonated amines. The recovery of metals depends both on hydrophobic properties of amine and sorbent and on sorption behaviour of amine itself. For on-line solid phase extraction of platinum group metals 4-(n-octyl)diethylenetriamine and hyper cross-linked polystyrene sorbent SSPS have been applied. Quantitative recovery of rhodium and platinum in the form of their hexachloride complexes was achieved under non-equilibrium conditions of on-line dilution. Metals recovered are quantitatively eluted with 1 M hydrochloric acid solution in ethanol. A new FIA-FAAS method for the determination of Rh, Pd and Pt in solutions based on the decomposition of ores and alloys has been proposed. The RSD values are 0.03-0.08 at 50-ppb concentration level. The detection limits are 3-8 ppb for 1 min of preconcentration. The accuracy of the procedure was verified by the analysis of standard reference materials of sulfide ores and alloys.  相似文献   

10.
He XC 《Talanta》1991,38(3):319-323
The ion flotation of rhodium(III) and palladium(II) with some anionic surfactants has been investigated. Two flotation procedures are proposed for the separation of some platinum metals, based on differences in the kinetic properties of the chloro-complexes of rhodium(III), palladium(II) and platinum(IV). The first involves the selective flotation of Rh(H(2)O)(3+)(6) from PdCl(2-)(4) and PtCl(2-)(6) in dilute hydrochloric acid with sodium dodecylbenzenesulfonate (SDBS). After precipitation of the hydroxide and redissolution in dilute acid, the Rh(III) is converted into Rh(H(2)O)(3+)(6), Pd(II) and Pt(IV) remaining as PdCl(2-)(4) and PtCl(2-)(6) respectively, and separation is achieved by floating the Rh(H(2)O)(3+)(6) with SDBS. The second is for separation of Pd(II). Prior to flotation, the solution of PdCl(2-)(4) and PtCl(2-)(6) is heated with ammonium acetate to convert PdCl(2-)(4) into Pd(NH(3))(2+)(4). The chloro-complex of Pt(IV) is unaffected. The complex cation, Pd(NH(3))(2+)(4), is then selectively floated with SDBS. The procedures are fast, simple and do not require expensive reagents and apparatus.  相似文献   

11.
Mirza MY 《Talanta》1980,27(2):101-106
The extraction of Pd(II), Rh(III), Ir(III), Au(III) and Pt(IV) from hydrochloric and hydrobromic acid with 5% tri-iso-octylamine solution in carbon tetrachloride has been studied. The gold extract from hydrochloric acid is yellow and absorbs at 325 nm, the palladium compound is red and absorbs at 290 nm and 467 nm, and the platinum compound is blood-red and shows absorption at 268 nm. The gold, palladium and platinum extracts from hydrobromic acid are crimson. reddish brown and blood-red, with maximum absorption at 260, 345 and 300 nm respectively. Methods have been devised for the separation of gold from platinum and for its determination and also for the simultaneous determination of palladium and platinum.  相似文献   

12.
An isotope dilution inductively coupled plasma quadrupole mass spectrometric (ID-ICP-QMS) method was developed for the simultaneous determination of the platinum group elements Pt, Pd, Ru, and Ir in environmental samples. Spike solutions, enriched with the isotopes 194Pt, 108Pd, 99Ru, and 191Ir, were used for the isotope dilution step. Interfering elements were eliminated by chromatographic separation using an anion-exchange resin. Samples were dissolved with aqua regia in a high pressure asher. Additional dissolution of possible silicate portions by hydrofluoric acid was usually not necessary. Detection limits of 0.15 ng x g(-1), 0.075 ng x g(-1), and 0.015 ng x g(-1) were achieved for Pt, Pd, Ru, and Ir, respectively, using sample weights of only 0.2 g. The reliability of the ID-ICP-QMS method was demonstrated by analyzing a Canadian geological reference material and by participating in an interlaboratory study for the determination of platinum and palladium in a homogenized road dust sample. Surface soil, sampled at different distances from a highway, showed concentrations in the range of 0.1-87 ng x g(-1). An exponential decrease of the platinum and palladium concentration with increasing distance and a small anthropogenic contribution to the natural background concentration of ruthenium and iridium was found in these samples.  相似文献   

13.
The adsorption of palladium(II), rhodium(III), and platinum(IV) from diluted hydrochloric acid solutions onto Fe(3)O(4) nanoparticles has been investigated. The parameters studied include the contact time and the concentrations of metals and other solutes such as H(+) and chloride. The equilibrium time was reached in less than 20 min for all metals. The maximum loading capacity of Fe(3)O(4) nanoparticles for Pd(II), Rh(III), and Pt(IV) was determined to be 0.103, 0.149, and 0.068 mmol g(-1), respectively. A sorption mechanism for Pd(II), Rh(III), and Pt(IV) has been proposed and their conditional adsorption equilibrium constants have been determined to be logK=1.72, 1.69, and 1.84, respectively. Different compositions of eluting solution were tested for the recovery of Pt(IV), Pd(II), and Rh(III) from Fe(3)O(4) nanoparticles. It was found that 0.5 mol L(-1) HNO(3) can elute all of the metal ions simultaneously, while 1 mol L(-1) NaHSO(3) was an effective eluting solution for Rh(III), and 0.5 mol L(-1) NaClO(4) for Pt(IV). In competitive adsorption, the nanoparticles showed stronger affinity for Rh(III) than for Pd(II) and Pt(IV).  相似文献   

14.
The extraction of Pt, Pd, Ir, Rh, Ru, Ag, Au, Co, Cu, Ni and Fe with n-octylaniline has been investigated. Noble metals are extracted 10(3)-10(4) times better than Cu, Ni, Co and Fe. A method of determination of Pt, Pd, Ir, Rh and Ru is proposed. They are first separated from Cu, Ni, Co and Fe by means of extraction (and then determined, in either the aqueous or organic phase, by atomic-absorption spectrophotometry. The atomic absorption of platinum metals (with the exception of Pd) is affected by other elements of the platinum group and by non-noble metals. La(NO(3))(3) and Nd(NO(3))(3) lower the limit of detection for Pt, Rh, Ir and Ru and inhibit the effect of Co, Cu, Ni, Fe, Bi, Zn, Na, etc. on their determination. Lanthanum and neodymium chlorides and sulphates produce a similar effect but only on the determination of Pt and Rh. The coefficient of variation of the determination, in both phases, is within 2-6.8%.  相似文献   

15.
Inductively coupled plasma-mass spectrometry coupled with cation exchange matrix separation has been optimised for the direct determination of platinum group element (PGE) and trace element emissions from a diesel engine car. After matrix separation method detection limits of 1.6 ng g(-1) for Pd, 0.4 ng g(-1) for Rh and 4.3 ng g(-1) for Pt were achieved, the method was validated against the certified reference material BCR 723, urban road dust. The test vehicle was fitted with new and aged catalytic converters with and without diesel particulate filters (DPF). Samples were collected after three consecutive New European Driving Cycle (NEDC) of the particulate and "soluble" phases using a home-made sampler optimised for trace element analysis. Emission factors for the PGEs ranged from 0.021 ng km(-1) for Rh to 70.5 ng km(-1) for Pt; when a DPF was fitted, the emission factors for the PGEs actually used in the catalysts dropped by up to 97% (for Pt). Trace element emission factors were found to drop by a maximum of 92% for Ni to a minimum of 18% for Y when a DPF was fitted; a new DPF was also found to cause a reduction of up to 86% in the emission of particulate matter.  相似文献   

16.
We have demonstrated the advantages of the dynamic preconcentration and separation of Pd(II) and Pt(IV) on paper carriers modified with 3-methyl-2,6-dimercapto-1,4-thiopyrone. The optimal conditions of the solid-phase reaction have been determined in Pd(II) sorption; after its separation Pt(IV), has been preconcentrated by sorption as its dimercaptides. Test scales have been produced for the visual determination of 0.5–40 μg Pd(II) and 1–195 μg Pt(IV) in 10- and 100 mL-samples, respectively. In addition, a procedure of their sorption-chromaticity densitometry determination from a single aliquot portion has been developed with detection limits of 5 and 1 ng/mL, respectively, and a procedure of Pd(II) determination using a test strip (c min = 0.40 mg/L) has been proposed. The procedures have been applied to the determination of palladium and platinum in electrolytes, sludges, and alloys.  相似文献   

17.
《Analytical letters》2012,45(14):2463-2474
Abstract

In this paper, 2‐carboxyl‐1‐naphthalthiorhodamine (CNTR) was synthesized, and a new method for the simultaneous determination of palladium, platinum, and rhodium ions as metal‐CNTR chelates was developed using rapid column high performance liquid chromatography combined with on‐line enrichment. The palladium, platinum, and rhodium ions were precolumn derivatized with CNTR to form colored chelates. The Pb‐CNTR, Pt‐CNTR, and Rh‐CNTR chelates could be absorbed onto the front of the enrichment column when they were injected into the injector and sent to the enrichment column (ZORBAX Stable Bound, 4.6×10 mm, 1.8 µm) with a buffer solution of 0.05 mol/L sodium acetate–acetic acid buffer solution (pH 3.5) as mobile phase. After enrichment, and by switching the six ports switching valve, the retained chelates were back‐flushed by mobile phase and traveling towards the analytical column. The separation of these chelates on the analytical column (ZORBAX Stable Bound, 4.6×50 mm, 1.8 µm) was satisfactory with 54% methanol (v/v) in 0.05 mol/L sodium acetate buffer (pH 3.5) containing 1 g/L Triton X‐100 as mobile phase. Palladium, platinum, and rhodium were separated completely within 2 min. The detection limits (S/N=3) of palladium, platinum, and rhodium are 1.4 ng/L, 1.2 ng/L, and 1.8 ng/L, respectively. This method was applied to the determination of palladium, platinum, and rhodium in water, urine, and soil samples with good results.  相似文献   

18.
The determination of palladium and platinum in alumina-supported bimetallic Pt-Re, Pd and Pt catalysts at the 0.03 and 0.3% (m/m) levels, respectively, and of rhodium and platinum in platinum sieve catalysts at the 0.04% (m/m) level and in the 4.75–19.75% (m/m) range, respectively, is described. The platinum group metals in fresh or spent catalysts are determined chromatographically using densitometry by forming theirN,N-diethyl-N-benzoylthiourea complexes. The precision of the method, %RSD, is 0.4–3.5, 2.2–6.7, and 4.2–6.0 for Pt, Pd and Rh, respectively. The accuracy was tested using alumina-based and active carbon platinum and palladium standards. The results were also compared with those obtained by FAAS. There was at most 8% difference between the results obtained with these methods, except for one active carbon based Pd standard.  相似文献   

19.
Marczenko Z  Kuś S  Mojski M 《Talanta》1984,31(11):959-962
The conditions [acid used, presence of chloride and tin(II)] for the extractive separation and spectrophotometric determination of palladium and platinum as the dithizonates Pd(HDz)(2) and Pt(HDz)(2) have been examined. In the absence of stannous chloride platinum does not undergo extraction. Conditions for the separation and determination of these metals in the presence of mercury, gold and copper, which are also extracted with dithizone into carbon tetrachloride or chloroform under the conditions suitable for palladium (1M sulphuric acid/0.1M hydrochloric acid), have been defined. The mercury and gold dithizonates are formed quickly and can be removed before the palladium and platinum compounds have had time to form. They can be decomposed with iodide. Copper dithizonate is decomposed by reduction with tin(II). The proposed procedure has been applied to the determination of palladium in technical platinum metal.  相似文献   

20.
《Analytical letters》2012,45(5-6):539-550
A new sampling system was developed in order to be applied directly at the exhaust pipe of vehicles combined with an exhaust gas analyzer during the standard New European Driving Cycle (NEDC). In that way a quantitative sampling of Pt, Pd, and Rh (Platinum Group Elements, PGEs) in particle form on filters and gas monitoring could be achieved simultaneously, applying the sampling system on a variety of vehicles of different age and engine capacity. The samples were examined by SEM-EDX for morphological and qualitative analysis of the particles. By using an appropriate digestion procedure and the analytical techniques of ICP-MS and GFAAS, concentrations were found in the range of 0.35–87 ng/km for Pt, 3.3–437 ng/km for Pd, and 0.9–72 ng/km for Rh. Furthermore the investigation showed that fresh catalysts as well as engines with larger capacity emitted higher amounts of PGEs in comparison to older catalysts and smaller capacity engines. According to the results of this research the palladium emissions were dominant in comparison to the platinum ones. This way of sampling might prove advantageous in testing new technology catalysts through their PGEs emission.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号