首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 178 毫秒
1.
王家斌  吴芳玲  赵琦 《色谱》2015,33(8):849-855
采用C18毛细管整体柱作为固相微萃取整体柱,构建在线固相微萃取-高效液相色谱联用系统,同步富集检测环境水样中的5种苯氧羧酸类除草剂。详细考察了联用系统运行条件对富集检测的影响。联用系统运行最佳参数为:固相微萃取整体柱长度20 cm,进样流速0.04 mL/min,进样13 min,洗脱流速0.02 mL/min,洗脱5 min。在最佳条件下,5种苯氧羧酸类除草剂的检出限为:9 μg/L (苯氧丙酸)、4 μg/L (2-(2-氯)-苯氧丙酸)、4 μg/L (2-(3-氯)-苯氧丙酸)、5 μg/L (2,4-二氯苯氧乙酸)、5 μg/L (2-(2,4-二氯苯氧基)丙酸)。与HPLC系统直接进样对比,联用系统对5种检测对象表现出优良的富集能力。5种苯氧羧酸类除草剂的回收率在79.0%~98.0%之间(RSD≤3.9%)。该方法成功应用于水样中5种苯氧羧酸类除草剂的检测,结果令人满意。  相似文献   

2.
建立了固相萃取(SPE)/超高效液相色谱-三重四极杆串联质谱(UPLC-MS/MS)同时测定水中8种苯氧羧酸类除草剂残留的方法。过滤后的样品经HLB固相萃取柱富集净化后,采用BEH C18柱,以2 mmol/L乙酸铵-乙腈作为流动相进行梯度洗脱,采用串联质谱进行检测。8种苯氧羧酸类除草剂在0.8~100μg/L质量浓度范围内线性关系良好(r=0.995 8~0.999 6),回收率为74%~90%,相对标准偏差为1.0%~12.0%,方法检出限(3S)为1.0~1.8 ng/L。该方法快速、灵敏,适用于水体中8种苯氧羧酸类除草剂残留的测定。  相似文献   

3.
建立了尿中2,4-滴(2,4-D)、2,4-滴丙酸(2,4-DP)2、甲4氯(MCPA)和2甲4氯丙酸(MCPP)4种苯氧羧酸类除草剂的气相色谱-质谱(GC-MS)分析方法。尿样加氯化钠饱和,酸化后用乙醚萃取,萃取物进行特丁二甲硅烷基(TBDMS)衍生化后分析。尿中4种除草剂的浓度在3~3 000 ng/mL范围内工作曲线的线性关系良好,检出限在1 ng/mL以下,3、100和1 000 ng/mL水平加标回收率在97.0%~102.2%之间,精密度在6.2%~14.2%之间。该法灵敏,可用于中毒者和职业接触者尿中苯氧羧酸类除草剂的分析。  相似文献   

4.
建立了气相色谱-串联质谱技术对烟草中15种苯氧羧酸类除草剂农药残留量的分析方法。样品采用乙腈提取、Carbon TPT固相萃取柱净化、三甲基硅烷化重氮甲烷衍生化,采用气相色谱-串联质谱对15种苯氧羧酸类除草剂进行测定,通过保留时间、选择离子及相对丰度定性,外标法定量。结果表明,15种苯氧羧酸类除草剂在20~1 000μg/L浓度范围内均呈良好线性关系,相关系数大于0.992,检出限为0.9~3.3μg/kg,定量下限为3.2~10.8μg/kg。在20,100,200μg/kg 3个加标水平下的平均回收率为71.5%~105.6%,相对标准偏差(RSD)为4.5%~14.9%。该方法简便、快速、灵敏,适用于烟草中15种苯氧羧酸类除草剂的同时检测。  相似文献   

5.
建立了基质校正液相色谱-串联质谱(HPLC-MS/MS)同时测定土壤中9种苯氧羧酸类除草剂残留量的分析方法。样品用含1.5%甲酸的乙腈溶液超声提取两次,提取液经氨基柱净化后,使用C18色谱柱,以含甲酸的水溶液和甲醇为流动相,在梯度条件下进行分离。在多级反应离子监测(MRM)负离子模式下进行质谱数据采集,采用两对离子进行定性和定量分析。9种苯氧羧酸类除草剂在2~250μg/L浓度范围内呈线性关系,相关系数为0.9929~0.9972;检出限在1.7~3.8μg/kg之间。土壤中9种苯氧羧酸类除草剂的3个浓度水平加标的平均回收率为85.3%~110.0%,相对标准偏差在3.2%~12.0%之间。  相似文献   

6.
黄幼芳  刘珺  黄晓佳 《色谱》2022,40(10):900-909
有效萃取是分析复杂样品中苯氧羧酸类除草剂(PAs)残留的关键步骤。为此,该文利用“一锅法”水热技术快速、简便地制备了氨基碳纳米管功能化磁性纳米粒子(NH-CNTs@M)并作为磁固相萃取(MSPE)的萃取介质,用于萃取谷物和蔬菜样品中痕量PAs。研究利用多种手段对NH-CNTs@M的形貌、尺寸、磁性性质等进行了表征,结果表明FeO的粒径、氨基化碳纳米管的直径以及NH-CNTs@M的磁饱和值分别为30 nm、40 nm和44.2 emu/g。详细考察了制备条件和萃取参数对NH-CNTs@M/MSPE萃取性能的影响,结果表明,NH-CNTs@M/MSPE可通过π-π、疏水和氢键作用有效富集目标化合物,最佳萃取条件如下:吸附剂用量为30 mg,解吸溶剂为含2.0%(v/v)甲酸的乙腈溶液,吸附时间和解吸时间分别为8.0 min和3.0 min,基底pH值为6.0,不调节基底的离子强度。将NH-CNTs@M/MSPE与高效液相色谱-二极管阵列检测技术(HPLC-DAD)联用,建立了谷物和蔬菜中PAs的灵敏检测方法。谷物和蔬菜基质中苯氧羧酸类除草剂的检出限(LOD,S/N=3)分别为0.32~1.6μg/kg和0.53~1.6μg/kg,定量限(LOQ,S/N=10)分别为0.94~4.8μg/kg和1.6~4.8μg/kg。在两种实际样品中不同浓度下的加标回收率分别为73.1%~112%和72.3%~113%。与现有方法相比,所建方法具有萃取速度快、灵敏度高和环境友好等特点。  相似文献   

7.
Peng X  Pang J  Deng A 《色谱》2011,29(12):1199-1204
建立了利用中空纤维三相液相微萃取-高效液相色谱联用技术(HF-LPME-HPLC)同时测定环境水中痕量麦草畏(dicamba)、氟草烟(fluroxypyr)、4-氯苯氧乙酸(4-CPA)、2甲4氯(MCPA)、2,4-滴(2,4-D)、2,4-滴苯氧丁酸(2,4-DB)和2甲4氯苯氧丁酸(MCPB)等7种苯氧羧酸类除草剂的分析方法。考察了萃取剂﹑接受相和给出相pH值、萃取时间﹑搅拌速度和盐效应等对检测的影响,通过正交试验优化萃取条件,得到的最佳萃取条件为正辛醇作萃取剂,给出相pH为3,接受相pH为12,萃取30 min,搅拌速度400 r/min。结果表明7种除草剂在较宽的线性范围内线性良好,相关系数为0.9953~0.9988,检出限(信噪比为3)为0.2~1.0 μg/L,富集倍数为76.7~121,加标回收率为68%~104%,相对标准偏差为3.2%~8.1%。该法灵敏度高、操作简单、检测快速、有机溶剂消耗少,为环境水样中痕量苯氧羧酸类除草剂残留的分析提供了有益的参考。  相似文献   

8.
采用气相色谱-质谱法测定大米中15种苯氧羧酸类除草剂的残留量。优化的试验条件如下:(1)提取溶剂为乙腈;(2)衍生温度为30℃;(3)衍生时间为20min;(4)净化萃取柱为Carbon TPT柱。在气相色谱分离中用PerkinElmer Elite-5MS毛细管柱为固定相,在质谱分析中采用全扫描和多反应监测模式。15种苯氧羧酸类除草剂的线性范围均为0.02~1.00mg·L~(-1),方法的检出限(3S/N)为0.001~0.006mg·kg~(-1)。以空白样品为基体进行加标回收试验,所得回收率为80.3%~103%,测定值的相对标准偏差(n=5)为4.9%~9.8%。  相似文献   

9.
辛国斌  谭家镒  姚丽娟  朱昱  姜兆林  宋辉 《色谱》2008,26(1):116-118
建立了一种血液中2,4-二氯苯氧乙酸(2,4-D)、2-(2,4-二氯苯氧)-丙酸(2,4-DP)和4-氯-2-甲基-苯氧乙酸(MCPA)3种苯氧羧酸类除草剂的分析方法.血样用0.1 mol/L盐酸稀释后用GDX401大孔树脂吸附、用乙醚洗脱,萃取物用二氯丙醇在硫酸催化下进行酯化衍生,衍生物经气相色谱-电子捕获检测.2,4-D、2,4-DP和MCPA的检测限分别为20,8和40 ng/mL.定量分析用2,4-二氯苯乙酸作内标,线性关系和回收率结果均令人满意.  相似文献   

10.
建立了高效液相色谱-质谱联用(HPLC—MS)选择离子监测(SIM)同时测定稻米中13种苯氧羧酸类除草剂多残留的方法。样品经过乙腈提取,盐酸酸化,SCX阳离子交换吸附剂分散固相萃取净化后,采用HPLC—MS测定。对13种苯氧羧酸类除草剂的液相色谱分离、样品前处理条件进行了详细的研究和优化,13种苯氧羧酸类除草剂在0.02~1.0mg/L范围内线性良好,相关系数为0.9954~0.9998。在0.05~1.0mg/kg范围内,平均添加回收率为77%~99%,相对标准偏差为0.9%~14.9%。  相似文献   

11.
邓玉兰  李傲天  王燕飞  孙鹏  苏萍  杨屹 《色谱》2018,36(3):253-260
制备了MIL-53(Fe)和聚多巴胺(PDA)修饰的磁性Fe_3O_4复合材料MIL-53(Fe)@PDA@Fe_3O_4,并将其作为吸附剂用于磁固相萃取-高效液相色谱法(MSPE-HPLC)检测环境水样中4种磺酰脲类除草剂(甲嘧磺隆、苄嘧磺隆、吡嘧磺隆和氯嘧磺隆)。实验优化了高效液相色谱条件(乙腈和含0.01%(体积分数)三氟乙酸的水溶液为流动相进行梯度洗脱,检测波长为233 nm)及磁固相萃取条件(洗脱剂为5 mL丙酮,萃取时间为4.5 min,吸附剂用量为60 mg,NaCl加入量为0.5 g,溶液pH值为3),在最佳条件下进行方法学考察,4种磺酰脲类除草剂均得到良好的线性关系,相关系数(r)≥0.998 0。方法的检出限(LOD,S/N=3)为0.28~0.77μg/L。将建立的方法用于3种环境水样中4种磺酰脲类除草剂的检测,其加标回收率为78.8%~109.7%。结果表明,制备的功能化复合材料结合了MIL-53(Fe)和Fe_3O_4的优点,可以简便快速地萃取分离环境水样中磺酰脲类除草剂。  相似文献   

12.
Phenoxy acid herbicides are widely used herbicides that play an important role in improving the yield and quality of crops. However, some research has shown that this kind of herbicide is poisonous to human and animals. In this study, a rapid and sensitive method was developed for the detection of seven phenoxy acid herbicides in water samples based on magnetic solid‐phase extraction followed by liquid chromatography and tandem mass spectrometry. Magnetic amino‐functionalized multiwalled carbon nanotubes were prepared by mixing bare magnetic Fe3O4 nanoparticles with commercial amino‐functionalized multiwalled carbon nanotubes in water. Then the amino‐functionalized multiwalled carbon nanotubes were used to enrich phenoxy acid herbicides from water samples based on hydrophobic and ionic interactions. The effects of experimental variables on the extraction efficiency have been studied in detail. Under the optimized conditions, the method validation was performed. Good linearities for seven phenoxy acid herbicides were obtained with squared regression coefficients ranging from 0.9971 to 0.9989. The limits of detection ranged from 0.01 to 0.02 μg/L. The method recoveries of seven phenoxy acid herbicides spiked at three concentration levels in a blank sample were from 92.3 to 103.2%, with inter‐ and intraday relative standard deviations less than 12.6%.  相似文献   

13.
Takino M  Daishima S  Nakahara T 《The Analyst》2001,126(5):602-608
A method for the determination of six chlorinated phenoxy acid herbicides in river water was developed using in-tube solid-phase microextraction (SPME) followed by liquid chromatography/electrospray ionization-mass spectrometry (LC/ESI-MS). In-tube SPME is an extraction technique for organic compounds in aqueous samples, in which analytes are extracted from a sample directly into an open tubular capillary by repeated draw/eject cycles of the sample solution. Simple mass spectra with strong signals corresponding to [M-H]- and [M-RCOOH]- were observed for all herbicides tested in this study. The best separation of these compounds was obtained with a C18 column using linear gradient elution with a mobile phase of acetonitrile-water containing 5 mmol l-1 dibutylamine acetate (DBA). To optimize the extraction of herbicides, several in-tube SPME parameters were examined. The optimum extraction conditions were 25 draw/eject cycles of 30 microliters of sample in 0.2% formic acid (pH 2) at a flow rate of 200 microliters min-1 using a DB-WAX capillary. The herbicides extracted by the capillary were easily desorbed by 10 microliters acetonitrile. Using in-tube SPME-LC/ESI-MS with time-scheduled selected ion monitoring, the calibration curves of herbicides were linear in the range 0.05-50 ng ml-1 with correlation coefficients above 0.999. This method was successfully applied to the analysis of river water samples without interference peaks. The limit of quantification was in the range 0.02-0.06 ng ml-1 and the limit of detection (S/N = 3) was in the range 0.005-0.03 ng ml-1. The repeatability and reproducibility were in the range 2.5-4.1% and 6.2-9.1%, respectively.  相似文献   

14.
建立了液相微萃取/高效液相色谱联用(LPME/HPLC)技术同时测定环境水中痕量异丙隆、秀谷隆和灭草隆除草剂的分析方法.考察了不同萃取条件及测定条件对检测结果的影响.优化后的萃取条件为:6μL正辛醇作萃取剂,液滴体积3μL,搅拌速度450 r/min,萃取30 min.结果表明,在优化条件下,3种除草剂的质量浓度在0....  相似文献   

15.
石芳  寿旦  金米聪  王宏伟  陈旭光  朱岩 《色谱》2022,40(2):139-147
随着麻醉剂广泛用于渔业生产过程和水产品运输等领域,建立水产品中麻醉剂残留的检测方法具有重要意义.由于水产品基质复杂且麻醉剂残留水平低,因此需要合适的前处理方法以提高检测灵敏度.该研究基于分散固相萃取-高效液相色谱,建立了一种同时检测水产品中普鲁卡因、丁氧卡因、三卡因、丁香酚、甲基丁香酚、异丁香酚、甲基异丁香酚7种麻醉剂...  相似文献   

16.
覃玲  董亚蕾  王钢力  曹进  丁宏 《色谱》2018,36(9):880-888
采用分散固相萃取结合液相色谱-串联质谱,选择4种代表性动物源性食品作为基质,建立了13类42种兽药残留的分析方法。样品经水分散后,以5%(v/v)甲酸乙腈提取,提取液经盐析后取乙腈层,用分散固相萃取净化包净化。目标物用C18色谱柱(100 mm×2.1 mm,2 μ m)分离,以甲醇和0.1%(v/v)甲酸水溶液为流动相进行梯度洗脱,利用电喷雾离子源多反应监测模式进行检测。42种兽药在各自的浓度范围内线性关系良好,相关系数均大于0.995;大多数化合物在4种样品基质中的3个添加水平下的平均回收率为65.8%~135.5%,相对标准偏差为0.5%~14.2%(n=6);检出限(LOD,S/N=3)和定量限(LOD,S/N=10)分别为0.01~1.68 μ g/kg和0.01~5.62 μ g/kg。该方法简便、快速、灵敏,适用于动物源性食品中42种兽药残留的定量、定性分析。  相似文献   

17.
陈智帆  吴叶宇  谭学才  蒙健清  岑洁  刘敏 《色谱》2022,40(6):556-564
研究建立了一种基于UiO-66-NH_(2)@纤维素复合气凝胶的高灵敏度固相萃取新方法,与高效液相色谱法联用用于保健品中西地那非的检测。先将纤维素进行醛基和酰肼基的功能化,然后将两种功能化的纤维素通过交联并负载UiO-66-NH_(2)形成复合气凝胶。将此复合气凝胶作为固相萃取的吸附剂使用时,易于收集且不需要外加磁场或者抽真空的辅助作用,操作简单。研究对制备所得的UiO-66-NH_(2)@纤维素复合气凝胶进行了X-射线粉末衍射、扫描电镜、红外光谱和N_(2)吸附等表征,结果显示UiO-66-NH_(2)成功负载于气凝胶的孔道中,纤维素气凝胶掺杂了UiO-66-NH_(2)之后其孔道结构变得规整,并且比表面积增大。研究优化了复合气凝胶中UiO-66-NH_(2)的负载量对萃取的影响,高比例的负载量有利于西地那非的富集,并且最高的负载率为50%。研究优化了影响西地那非富集效率的实验条件,包括溶液pH、萃取时间、洗脱剂类型、洗脱时间、洗脱体积和离子强度。采用安捷伦Zorbax Eclipse Plus C18色谱柱(150 mm×4.6 mm,5μm)进行分离,以含0.1 mol/L三乙胺的磷酸盐水溶液(pH=6.50)-乙腈(30∶70,v/v)为流动相进行洗脱,检测波长为292 nm。在最佳的萃取条件下(pH为9.0,萃取时间为60 min,洗脱剂为乙腈,洗脱液体积为3×2 mL,洗脱时间为40 min),该分析方法的线性范围为10~2000 ng/mL(相关系数R^(2)=0.9949),检出限(LOD,S/N=3)为2.85 ng/mL,富集因子为59.17。将该方法用于保健品中西地那非的萃取,所得回收率为74.93%~89.12%,相对标准偏差为2.8%~5.3%,表明了方法的回收率和精密度良好,说明了该方法具有应用于保健品中西地那非日常检测的潜力。  相似文献   

18.
A high-performance liquid chromatographic (HPLC) method for phenoxy acid herbicides using precolumn derivatization with 9-anthryldiazomethane (ADAM) is presented. The phenoxy acid herbicides investigated were (2,4-dichlorophenoxy)acetic acid, (4-chloro-2-methylphenoxy)acetic acid, 2-(4-chloro-2-methylphenoxy)propionic acid and (4-chloro-2-methylphenoxy)butyric acid. These herbicides reacted with ADAM under mild conditions and were converted into the corresponding fluorescent derivatives. The ADAM derivatives were separated by reversed-phase HPLC and determined using a fluorescence detector. The detection limits were about 500 pg per injection. For the application of ADAM to the determination of these herbicides in ground waters, the recoveries were more than 93% and the average relative standard deviation was 6.0% at 0.5 microgram/l. The procedure is useful as a screening method for phenoxy acid herbicides in ground water samples.  相似文献   

19.
采用分散固相萃取-气相色谱-串联质谱(QuEChERS-GC-MS/MS)建立了蔬菜中107种农药残留量的分析方法。样品由含1%冰醋酸的正己烷饱和乙腈提取、分散固相萃取法净化,采用气相色谱-串联质谱方法在分时段选择反应监测模式下进行测定,外标法定量。所有农药在0.05~1 mg/L范围内线性关系均良好;所有农药的方法定量限(LOQ)均低于10 μg/kg;在10 μg/kg的添加水平下,大蒜、青刀豆、萝卜和菠菜4种基质中绝大多数农药的平均回收率处于60%~130%之间,相对标准偏差(RSD)不大于15.3%。该方法不仅能用于多种蔬菜基质中107种农药残留的检测,而且还能较好地解决本底成分相当复杂的大蒜基质极易出现的干扰问题。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号