排序方式: 共有15条查询结果,搜索用时 15 毫秒
1.
2.
A spectroscopic method to determine thickness of quartz wave plate is presented. The method is based on chromatic polarization interferometry. With the polarization-resolved transmission spectrum (PRTS) curve, the phase retardation of quartz wave plate can be determined at a wide spectral range from 200 to 2000 nm obviously. Through accurate judgment of extreme points of PRTS curve at long-wave band, the physical thickness of quartz wave plates can be obtained exactly. We give a measuring example and the error analysis. It is found that the measuring precision of thickness is mainly determined by the spectral resolution of spectrometer. 相似文献
3.
4.
介绍了一种新型高精度大动态范围可调线性偏振度参考光源(VPOLS-II),在0.46~2μm波段内线性偏振度调节范围达到0~0.72。VPOLS-II采用四片平板玻璃起偏的工作原理,辐射光源经过积分球和扩束器准直系统形成具有较高均匀性和平行度的入射光,再经过偏振态调节器输出不同线性偏振度的偏振光。将光谱偏振分析仪实验测量结果与理论计算值进行了比对,分析了VPOLS-II输出线性偏振度不确定度的影响因素。结果表明,线性偏振度范围0~0.72内,VPOLS-II的线性偏振度与理论预测值的差异小于6×10^-3。在线性偏振度范围0.01~0.09和0.09~0.72内,线性偏振度的不确定度分别为8.8%~0.936%和0.936%~0.184%。这种新型参考光源可用于偏振光学遥感器的实验室偏振定标和系统级性能检测。 相似文献
5.
消色差/4波片具有一定的二向色性和相位延迟量误差,导致仪器偏振测量产生误差。从考虑全偏振CCD相机自身偏振效应的辐射模型入手,借助积分球辐射源和高精度辅助旋转偏振器,研究系统级非理想消色差/4波片的标定方法。结果发现:消色差/4波片的二向色性和相位延迟量参数随仪器的工作波长与带宽发生变化,波段650 nm(相位延迟量88.90)和750 nm(相位延迟量88.65)消色差效果相对较好,而波片在波段850 nm(相位延迟量84.33)相位量偏差较大;通过相位延迟量的标准误差分析,得出消色差/4波片的系统级标定方法精度优于0.8。 相似文献
6.
铁-锆交联蒙脱土的制备和结构表征 总被引:11,自引:0,他引:11
我们首次合成了铁锆复合柱交联蒙脱土, 并用XRD, 比表面及孔径测定和Mossbauer谱学等方法进行了表征。结果表明, 铁锆交联蒙脱土比表面增大为原土的三倍以上, 其层间距可达0.88nm(d001=1.84nm)。热稳定性明显高于单一Fe柱交联蒙脱土。在500℃加热后层间距保持0.63nm~0.71nm。但由于铁柱的坍塌造成微孔减少, 比表面明显下降。Mossbauer谱研究表明, 500℃焙烧单一铁柱转变为α-Fe~2O~3, 而Fe-Zr-PILC中铁仍以超顺磁Fe^3^+存在, 单一铁柱的铁组分在400℃可还原为金属铁, 而铁锆混合柱交联蒙脱土中由于铁与锆之间存在较强的相互作用, 450℃氢气气氛中铁组分仍不能还原为金属铁。 相似文献
7.
A new material of Zr0.1Al1.9Mo2.9V0.1O12 is synthesized by the traditional solid state synthesis method.The phase transition,coefficient of thermal expansion,and luminescence properties of Zr0.1Al1.9Mo2.9V0.1O12 are explored with Raman spectrometer,dilatometer,and x-ray diffraction(XRD)diffractometer.The results show that the Zr0.1Al1.9Mo2.9V0.1O12 possesses the strong broad-band luminescence characteristics almost in the whole visible region.The sample is crystallized in a monoclinic structure group of P21/a(No.14)crystallized at room temperature(RT).The crystal is changed from monoclinic to orthorhombic structure when the temperature increases to 463 K.The material has very low thermal expansion performance in a wide temperature range.Its excellent low thermal expansion and strong pale green light properties in a wide temperature range suggest its potential applications in light-emitting diode(LED)and other optoelectronic devices. 相似文献
8.
9.
10.
一种高精度偏振遥感探测方式的精度分析 总被引:5,自引:0,他引:5
检偏器的角度误差是影响偏振遥感探测精度的重要因素之一,是许多高精度定量化偏振遥感需要考虑的一个问题。在检偏器(0°,60°,120°)放置的测量系统中,当入射光偏振角接近于0°或180°时偏振测量易产生最大误差值,而偏振角接近30°,90°和150°时,偏振度的测量具有很高的精度;在检偏器(0°,45°,90°)放置方式中,偏振角接近45°的光束测量易具有最大误差值,而偏振角接近于0°,90°和135°时,角度误差对偏振度测量精度的影响很小。除了个别偏振角外,对高偏振度入射光束的偏振测量通常具有较大的偏振测量误差。因此,引进线偏振光的平均偏振度测量精度描述偏振测量装置的优劣,结果表明检偏器(0°,60°,120°)放置方式优于检偏器(0°,45°,90°)放置方式。 相似文献