首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   39篇
  免费   2篇
化学   34篇
数学   1篇
物理学   6篇
  2021年   1篇
  2020年   4篇
  2019年   4篇
  2018年   1篇
  2014年   1篇
  2013年   1篇
  2012年   4篇
  2011年   1篇
  2010年   1篇
  2009年   3篇
  2007年   3篇
  2006年   3篇
  2005年   3篇
  2004年   4篇
  2003年   2篇
  2000年   1篇
  1996年   1篇
  1995年   2篇
  1994年   1篇
排序方式: 共有41条查询结果,搜索用时 15 毫秒
1.
In this study, new chalcone compound 1 , new phthalonitrile derivatives 2 and 3, new copper(II), manganese(III) phthalocyanines bearing chalcone groups at peripheral or nonperipheral positions were synthesized. Electrochemistry of tetra-(4-{(2 E )-3-[2-fluoro-4-(trifluoromethyl)phenyl]prop-2-enoyl}phenoxy) substituted Co(II)Pc and Mn(III)Pcs were studied with cyclic voltammetry (CV) to determine the redox properties of the phthalocyanines. According to the results, while the CuPcs 2a and 3a showed two Pc based reduction reactions and one Pc based oxidation reaction, MnPcs 2b and 3b gave two metal-based reduction reactions. All the redox processes are shifted toward positive potentials as a result of the increased electron-withdrawing ability of the trifluoromethyl substituents.  相似文献   
2.
A new, specific and sensitive GC‐MS method with electron impact ionization technique was developed for quantitative analysis of ezetimibe (EZE) in human plasma. Prior to GC analysis, EZE was derivatized with N‐methyl‐N‐trimethylsilyl‐trifluoroacetamide (MSTFA), which is a trimethyl silylating reagent. The derivatization reaction was optimized and parameters such as catalyst, derivatization time, temperature, solvent and the volume of silylating reagent were investigated. Trimethylsilyl ether derivative of EZE was determined in selected ion monitoring (SIM, mass‐to‐charge ratio (m/z): 326) mode. The method was validated with respect to LOD and LOQ, precision, accuracy, linearity, specificity, stability, and recovery. The LOQ and LOD were found as 15 and 10 ng/mL, respectively. The linearity of the method ranged from 15 to 250 ng/mL. The correlation coefficient of the calibration curve was 0.9977 ± 0.0004 (± S.E.M.). The intra‐ and inter‐day precisions (RSD) were less than 6% and accuracies (bias) for intra‐ and inter‐day accuracy were found between –4.04 and 9.71% at four different concentration levels (15, 40, 100, 250 ng/mL). The proposed method was successfully applied to real human plasma samples for determination of total EZE.  相似文献   
3.
Two methods involving the rhodium-catalyzed reaction of 2-en-4-yne acetates and the palladium-catalyzed reaction of 2-en-4-yne carbonates with organoboronic acids were investigated; both afforded exclusively the (E)-configured vinylallenes. The coordinative interaction of the rhodium with the acetate group promoted the δ-elimination of Rh(I)-OAc from the alkenylrhodium intermediate II in both syn and anti modes, with the syn-elimination being the major path. DFT calculations revealed that a conformer of this intermediate (II), which can lead to the (E)-configured vinylallene product via the syn-elimination mode, is energetically the most favorable conformer. The rhodium-catalyzed procedure is not applicable to reactions involving (E)-configured enyne acetates, because the geometry of the alkenylrhodium intermediate that is derived from the corresponding (E)-enyne acetate would not allow such coordinative interaction to occur. The palladium-catalyzed method, which proceeds through formation of the σ-vinylallenylpalladium intermediate, B, is suitable for both the (E)- and (Z)-configured enyne carbonates and appears to have a wider scope for both organoboronic acids and enyne substrates. The palladium-catalyzed reaction of an enantiomerically enriched enyne carbonate proceeded with racemization.  相似文献   
4.
Mode-locking characteristic of hybrid soliton pulse source (HSPS) utilizing linearly chirped raised-cosine flat top apodized fiber Bragg grating (FBG) is investigated by using coupled-mode equations. It is found that the fundamental repetition frequency range of HSPS is significantly extended by using linearly chirped raised-cosine flat top apodized FBG instead of linearly chirped Gaussian apodized FBG. The range of repetition frequencies over which proper mode-locking is obtained is 2-3.3 GHz with linearly chirped raised-cosine flat top apodized grating whereas this range is 2.1-2.95 GHz with linearly chirped Gaussian apodized grating.  相似文献   
5.
The noise of hybrid soliton pulse source (HSPS) with linearly chirped Gaussian apodized fiber Bragg grating is analyzed by couple-mode equations including spontaneous emission noise when the HSPS is mode-locked. Relative intensity noise is calculated using numerical solutions of these equations. It is shown that transform limited pulses are generated over a wide tuning range around the fundamental mode-locking frequency with low spontaneous noise. However, a high noise level affects the operation of device, and therefore transform-limited pulses are not obtainable over a wide tuning range. It is also shown that noise is extremely sensitive to the RF and DC currents, linewidth enhancement factor, gain saturation parameter and spontaneous coupling factor.  相似文献   
6.
N-acetyl-l-cysteine (NAC) is a well-known antioxidant that is capable of facilitating glutathione (GSH) biosynthesis and replenishing intracellular GSH under oxidatively challenging circumstances. N-acetyl-cysteine-amide (NACA), the amide form of NAC, is a newly designed and synthesized thiol-containing compound which is believed to be more lipophilic and permeable through cell membranes than NAC. The metabolic and antioxidant effects of these compounds in vitro and in vivo are under investigation. However, an analytical method that can separate and quantify both compounds simultaneously is not yet available, to the best of our knowledge. Because of their structural similarities, the two compounds are difficult to separate using earlier HPLC methods which were designed for NAC quantification. Therefore, the goal of this work was to develop an HPLC method with fluorescence detection for simultaneous quantification of NAC and NACA in biological blood and tissue samples. A gradient HPLC program with fluorescence detection (lambda(ex) = 330 nm, lambda(em) = 376 nm) using N-(1-pyrenyl)maleimide (NPM) as the derivatizing agent was developed. The calibration curves were linear over a concentration range of 25-5000 nm (r(2) > 0.997). The coefficients of variation for within-run precision and between-run precision ranged from 0.67 to 5.23% and for accuracy ranged from 0.98 to 10.54%; the percentage relative recovery ranged from 94.5 to 102.8%. This new method provides satisfactory separation of NAC and NACA, along with other biological thiols, in 20 min with a 5 nm limit of detection (LOD) per 5 microL injection volume.  相似文献   
7.
G(3, m, n) is the group presented by . In this paper, we study the structure of G(3, m, n). We also give a new efficient presentation for the Projective Special Linear group PSL(2, 5) and in particular we prove that PSL(2, 5) is isomorphic to G(3, m, n) under certain conditions.  相似文献   
8.
The electrochemical reduction of fenofibrate at a hanging mercury drop electrode (HMDE) was investigated by cyclic voltammetry, square-wave voltammetry, and chronoamperometry. Different buffer solutions were used over a wide pH range (3.0–10.0). The best definition of the analytical signals was found in borate buffer (pH 9.0)–tetrabutylammonium iodide mixture containing 12.5% (v/v) methanol at –1.2 V (versus Ag/AgCl). According to cyclic voltammetric studies, the reduction was irreversible and diffusion controlled. The diffusion coefficient was 2.38×10–6 cm2 s–1 as determined by chronoamperometry. Under optimized conditions of square-wave voltammetry, a linear relationship was obtained between 0.146–4.96 g mL–1 of fenofibrate with a limit of detection of 0.025 g mL–1. Validation parameters such as sensitivity, accuracy, precision, and recovery were evaluated. The proposed method was applied to the determination of fenofibrate in pharmaceutical formulations. The results were compared with those obtained by a published high-performance liquid chromatography method. No difference was found statistically.  相似文献   
9.
Anion sensor properties of N‐alkyl‐substituted 1,4′‐diazaflavonium bromides in methanol–water were evaluated by UV–vis spectrometry. Pronounced changes were observed in the absorption spectra of all compounds for only OH?, CO32?, and CN? among F?, Cl?, Br?, I?, OH?, CO32?, NO3?, PO43?, CN?, SO42?, HSO4?, HCO3?, SCN?, NO2?, and P2O72? ions. Two new absorption bands at 385 and 685 nm accompanying the distinct color change for OH?, CO32?, and CN? ions were observed in case of all compounds. The color changes were from pink to blue for CO32? and OH? ions and from pink to purple for CN? ion. Thanks to the distinct color change, the compounds can be used as selective colorimetric anion sensors. Linear changes of absorbance of N‐heptyl‐substituted compound at 385 nm as a function of the ion concentration were used to determine CN? ion in water samples. Detection and quantification limits of the proposed method were 0.94 and 2.82 mg/L, respectively.  相似文献   
10.
A poly(2‐aminophenylbenzimidazole)/gold nanoparticles (P2AB/AuNPs) coated disposable pencil graphite electrode (PGE) was fabricated as an enzyme‐free sensor for the H2O2 determination. P2AB/AuNPs and P2AB were successfully synthesized electrochemically on PGE in acetonitrile for the first time. The coatings were characterized by scanning electron microscopy, X‐ray diffraction spectroscopy, Energy‐dispersive X‐ray spectroscopy, Surface‐enhanced Raman spectroscopy, and UV‐Vis spectroscopy. AuNPs interacted with P2AB as carrier enhances the electrocatalytic activity towards reduction of H2O2. The analytical performance was evaluated in a 100 mM phosphate buffer solution at pH 6.5 by amperometry. The steady state current vs. H2O2 concentration is linear in the range of 0.06 to 100 mM (R2=0.992) with a limit of detection 3.67×10?5 M at ?0.8 V vs. SCE and no interference is caused by ascorbic acid, dopamine, uric acid, and glucose. The examination for the sensitive determination of H2O2 was conducted in commercially available hair oxidant solution. The results demonstrate that P2AB/AuNPs/PGE has potential applications as a sensing material for quantitative determination of H2O2.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号