Electrochemical studies and square-wave voltammetric determination of fenofibrate in pharmaceutical formulations |
| |
Authors: | Ceren?Yard?mc? Email author" target="_blank">Nuran??zalt?nEmail author |
| |
Institution: | (1) Department of Analytical Chemistry, Faculty of Pharmacy, Hacettepe University, Shhiye, 06100 Ankara, Turkey |
| |
Abstract: | The electrochemical reduction of fenofibrate at a hanging mercury drop electrode (HMDE) was investigated by cyclic voltammetry, square-wave voltammetry, and chronoamperometry. Different buffer solutions were used over a wide pH range (3.0–10.0). The best definition of the analytical signals was found in borate buffer (pH 9.0)–tetrabutylammonium iodide mixture containing 12.5% (v/v) methanol at –1.2 V (versus Ag/AgCl). According to cyclic voltammetric studies, the reduction was irreversible and diffusion controlled. The diffusion coefficient was 2.38×10–6 cm2 s–1 as determined by chronoamperometry. Under optimized conditions of square-wave voltammetry, a linear relationship was obtained between 0.146–4.96 g mL–1 of fenofibrate with a limit of detection of 0.025 g mL–1. Validation parameters such as sensitivity, accuracy, precision, and recovery were evaluated. The proposed method was applied to the determination of fenofibrate in pharmaceutical formulations. The results were compared with those obtained by a published high-performance liquid chromatography method. No difference was found statistically. |
| |
Keywords: | Fenofibrate Square-wave voltammetry Pharmaceutical formulations |