全文获取类型
收费全文 | 55篇 |
免费 | 20篇 |
国内免费 | 1篇 |
专业分类
化学 | 12篇 |
力学 | 14篇 |
数学 | 2篇 |
物理学 | 48篇 |
出版年
2022年 | 1篇 |
2020年 | 3篇 |
2019年 | 1篇 |
2018年 | 1篇 |
2017年 | 4篇 |
2016年 | 3篇 |
2015年 | 4篇 |
2014年 | 3篇 |
2013年 | 4篇 |
2012年 | 6篇 |
2011年 | 3篇 |
2010年 | 2篇 |
2009年 | 4篇 |
2008年 | 2篇 |
2007年 | 4篇 |
2006年 | 8篇 |
2005年 | 2篇 |
2004年 | 1篇 |
2003年 | 1篇 |
2002年 | 5篇 |
2001年 | 4篇 |
2000年 | 1篇 |
1999年 | 1篇 |
1997年 | 4篇 |
1995年 | 1篇 |
1991年 | 1篇 |
1989年 | 1篇 |
1987年 | 1篇 |
排序方式: 共有76条查询结果,搜索用时 15 毫秒
41.
Mrevlishvili G. M. Sottomayor M. J. Ribeiro da Silva M. A. V. Mdzinarashvili T. D. Al-Zaza M. Tediashvili M. Tushishvili D. Chanishvili N. 《Journal of Thermal Analysis and Calorimetry》2001,66(1):103-113
Journal of Thermal Analysis and Calorimetry - Bacterial viruses genome- ds-DNA -expulsion from the phage capsid is induced by temperature and is not accompanied by heat effects (temperature... 相似文献
42.
Three quantitative methods, namely profilometry, high speed imaging and recoil momentum measurements using a ballistic pendulum, are used to determine the interplay of vaporization, melt displacement and melt ejection on nanosecond laser induced material removal. At low to moderate fluences (<7 J cm−2) material removal occurs via vaporization and melt displacement in aluminium. At high fluences (>7 J cm−2), material removal occurs predominantly via the explosive ejection of liquid droplets from the melt pool. 相似文献
43.
Qiankun Dang Fuxing Xu Xiaohua Huang Xiang Fang Rizhi Wang Chuan‐Fan Ding 《Journal of mass spectrometry : JMS》2015,50(12):1400-1408
It is well known that superimposition of some positive octopole field will benefit the performance of ion trap mass analyzer. In the radial‐ejection linear ion trap (LIT), adding some octopole field component to the main quadrupole field is usually accomplished by stretching the ejection rod pair. In this study, the effect of octopole potential and some other higher order potential on the performance of LIT mass analyzer is investigated. A simple and effective method, which is to add some octopole component by building a LIT with a pair of rectangular electrodes and a pair of semi‐circular electrodes, is reported. Its properties were studied by numerical simulations and experiments. The results showed that a certain amount of positive octopole component could be produced by simply adjusting the position and width of the rectangular electrodes. A resolution of over 1200 at m/z 609 (~1600 Da/s) was observed in this type of LIT. They also performed tandem mass spectrometry well. The device with optimum geometry for ion ejection from rectangular electrodes provided comparable performance to that for ion ejection from semi‐circular electrodes. This type of LIT design is easy for fabrication and assembly. Copyright © 2015 John Wiley & Sons, Ltd. 相似文献
44.
Numerical observation of preferred directionality in ion ejection from stretched rectilinear ion traps 总被引:1,自引:1,他引:0
A. Krishnaveni Neeraj Kumar Verma A.G. Menon Atanu K. Mohanty 《International journal of mass spectrometry》2008,275(1-3):11-20
We report on numerical investigations of directionality of ion ejection in stretched rectilinear ion traps (RIT). Three 4-electrode trap geometries have been investigated. In all cases, one pair of electrodes has slits at their center and the other pair has no slits. The studied traps include the RIT-S, in which the mass analyzer electrodes are symmetrically positioned around the central axis; the RIT-X, in which the mass analyzer has a stretch in the direction of the electrodes which have slits (labeled as x-direction); and the RIT-Y, in which the mass analyzer has a stretch in the direction of the electrodes which have no slits (labeled as y-direction).Our analysis has been carried out on two-dimensional (2D) fields at the centre of an infinitely long mass analyzer. The boundary element method (BEM) has been used for field computations. The trajectory of ion motion has been generated using Runge Kutta fourth order integration.Three sets of simulations have been carried out on each of the RIT-S, the RIT-X and the RIT-Y to check for directionality of ion ejection. In the first, we numerically obtain the stability region on the potential (Udc– Vrf) axes. In the second we generate an escape velocity plot with Udc=0 for different values of Vrf. In the third, we simulate the mass selective boundary ejection experiment on a single ion.In the symmetric RIT-S, as expected, all three simulations show that there is an equal probability of ion reaching the trap boundary in either of the x- or y-directions. For the stretched traps, however, the results are dramatically different. For the RIT-X, all three simulations suggest that ion destabilization at the stability boundary occurs in the x-direction. Similarly, for the RIT-Y, ions preferentially get destabilized in the y-direction. That is, ions reaching the trap boundary overwhelmingly prefer the stretch direction. 相似文献
45.
A simple technique of preparing a continuous laminar liquid flow in vacuum (liquid beam) was developed and combined with multiphoton ionization and a time-of-flight mass spectrometer. This technique was applied to the study on resonance photoionization of an aniline (AN)-propanol (PrOH) solution (0.1 – 0.3 M). Binary cluster ions of aniline and propanol, AN+(PrOH)n (n ≤ 1), and protonated propanol cluster ions, H+(PrOH)n (n ≤ 1), were observed as product ions in the gas phase. The relative intensities of AN+PrOH and those of H+(PrOH)2 were measured as functions of the excitation laser power and the concentration of aniline in the propanol solution. The dependences of the ion intensities on the laser power and the AN concentration are explained in terms of a Coulomb ejection model, where the ions are ejected from the surface by Coulomb repulsion exerted from neighboring ions. It is also concluded that H+(PrOH)n is produced by a proton transfer reaction from an aniline ion to solvent molecules in the solution. 相似文献
46.
本文主要研究铝自由面微粒子喷射量随压力加载速率的关系,重点是对微射流机制的研究。用人工楔形槽作为自由面上的模拟几何缺陷,用斜波发生器技术改变加载速度,用石英传感器技术测量微粒子喷射量。研究结果表明:在楔形槽尺寸和峰值应力不变的条件下,微粒子喷射量及其最大喷射速度,均随加载速度(加载波阵面宽度的一种度量)的减小而减小;在压力加载条件不变时,发现微粒子喷射量有随几何缺陷体积的增加而增大的迹象。用HELP编码对本实验进行的二维数值模拟结果表明,在数值上与实测数据基本符合。 相似文献
47.
48.
Ding L Sudakov M Brancia FL Giles R Kumashiro S 《Journal of mass spectrometry : JMS》2004,39(5):471-484
In a digital ion trap (DIT), the quadrupole trapping and excitation waveforms are generated by the rapid switching between discrete d.c. voltage levels. As the timing of the switch can be controlled precisely by digital circuitry, the approach provides an opportunity to generate mass spectra by means of a frequency scan in contrast to the conventional voltage scan, thus providing a wider mass range of analysis. An instrument has been constructed which employs a 'non-stretched' ion trap and the field fault around the aperture of the end-cap electrode can be corrected electronically using a field-adjusting electrode. The ion trap was coupled with electrospray ionization (ESI) and atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) sources to demonstrate the capability of the digital method. AP-MALDI mass spectra of singly charged ions with mass-to-charge ratios upto 17 000 Th were generated using a trapping voltage of only 1000 V. Forward and reverse mass scans at resolutions up to 19 000 and precursor ion isolation at resolutions up to 3500 with subsequent tandem mass spectrometric analysis were demonstrated. The method of generating the digital waveforms and period scan is described. Discussion of the issues of mass range, scan speed, ion trapping efficiency and collision-induced dissociation efficiency are also provided. 相似文献
49.
50.