首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 718 毫秒
1.
Nafion/活性炭涂层固相微萃取探头的制备与应用研究   总被引:4,自引:0,他引:4  
采用Nafion和活性炭粉末作为固相涂层在不锈钢丝上交替涂制了固相微萃取探头(SPME),研究了它的特性,并与商品类似探头和单纯的Nafion探头作了比较。该探头可比商品探头(SPME)的富集率高1个数量级。由于Nafion有很强的极性,因此它对极性化合物有很强的萃取能力,适合萃取醇等物质。用该探头测定了醇类、酯类物质,检出限低于10ng/mL,相对标准偏差RSD<6 3%。  相似文献   

2.
新型固相微萃取探头测定工业废水中的甲苯和二甲苯   总被引:9,自引:0,他引:9  
采用溶胶-凝胶方法研制的聚甲基苯基乙烯基硅氧烷/羟基硅油复合涂层的固相微萃取探头及顶空固相微萃取-气相色谱联用技术(HS-SPME-GC),测定了制漆厂排放的工业废水中的甲苯和二甲苯。研究了影响该方法分析灵敏度的各种条件因素:萃取时间和温度,解吸时间和温度及离子强度等。结果表明新探头性能优于商用聚二甲基硅氧烷探头。方法的检出限为0.01μg/L-0.1μg/L,相对标准偏差小于6%;除苯以外线性范围达3个数量级。  相似文献   

3.
Nafion涂层固相微萃取探头的制备   总被引:6,自引:2,他引:4  
采用Nafion作为固相涂层在不锈钢丝上涂制了固相微萃取 (SPME)探头 ,研究了它的特性 ,并与类似商品探头作了比较。该探头具有萃取量大、可比商品探头 (SPME)的富集率高 1个数量级 ,灵敏度高、寿命长、且不易折断等特性。由于Nafion有很强的极性 ,因此它对极性化合物有很强的萃取能力 ,适合萃取醇等物质。用该探头测定了醇类物质 ,检出限达 2 0~ 60ng·ml-1,相对标准偏差RSD <5 %。  相似文献   

4.
采用溶胶-凝胶法制备了一种双缩水甘油基杯[4]芳烃羟基硅油探头,运用自行设计的反萃取装置实现了顶空固相微萃取与毛细管电泳的离线联用,结合超声反萃取和场放大进样技术成功地测定了尿样中兴奋剂普萘洛尔异构体的含量。实验考察了固相微萃取条件和反萃取条件对测定结果的影响,比较了杯[4]芳烃探头与商品化探头对于尿样中普萘洛尔异构体的萃取性能,结果表明基于杯[4]芳烃探头的固相微萃取过程能够实现满意的净化效应与预富集效应。利用毛细管电泳-二极管阵列检测器对加标尿样中普萘洛尔异构体测定的线性范围为0.05~10 mg/L,检测限为8~10 μg/L,相对标准偏差小于6.5%(n=6),两种异构体的加标回收率为86%~107%(n=5)。该探头的可重复使用(>150次)性能良好。  相似文献   

5.
采用溶胶-凝胶方法制备了三甲基杯[6]芳烃/羟基硅油(C[6]/OH-TSO)固相微萃取(SPME)探头,通过与气相色谱-氢火焰(GC-FID)联用测定了土壤中的多环芳烃(PAHs)。考察了影响萃取效率的因素如时间、温度和盐浓度等,比较了杯[6]芳烃探头和杯[4]芳烃探头以及商用PDMS探头对PAHs的萃取效果。结果表明:杯[6]芳烃SPME探头具有耐高温(380℃)、使用寿命长(7200次)等特点,对样品中PAHs的萃取效果明显优于其它探头。本方法检出限低(0.008~0.440mg/L),重现性好(RSD<7%),线性范围宽(3个数量级)。回收率在70.20%~105.1%之间。  相似文献   

6.
本文以多氯联苯(PCBs)模拟水样为实验样品,优化了杯[4]芳烃探头顶空固相微萃取(HS-SPME)的分析条件,并将杯[4]芳烃探头和商用PDMs探头对PCBs的萃取效果进行了比较。利用杯[4]芳烃-HS-SPME法与USEPA608法同时测定了模拟水样和典型污染地区环境样品中的多氯联苯。研究结果表明:杯[4]芳烃SPME探头对样品中高氯代PCBs的萃取效果优于商用PDMs探头;杯[4]芳烃-HS-SPME和USE-PA608法对同一样品的检测结果一致;该法对水样中PCBs的检出限达1~6ng/L,比USEPA608法的灵敏度提高近3个数量级。  相似文献   

7.
利用石墨烯的自组装性能,原位制备了基于石墨烯材料的固相微萃取(SPME)探头,并结合气相色谱-质谱(GC-MS)建立了水体中甲苯、乙苯和邻二甲苯的分析方法。通过SEM对探头进行表征,发现制备的探头石墨烯材料均匀、牢固地结合在石英光纤上。通过优化萃取模式、萃取温度、萃取时间和盐度,得到最佳条件:顶空萃取模式、萃取温度为40℃、萃取时间为3 min、盐度为30%NaCl。在最佳条件下,3种苯系物在0.2~200μg/L范围内呈现出良好的线性,线性系数(r~2)为0.998 7~0.999 6;检出限为0.001 2~0.004 2μg/L;其相对标准偏差小于5%。对采集的3个样品进行测定,均不同浓度地测出了苯系物污染,其加标回收率为90.3%~111%。该方法可用于环境水样中挥发性苯系物的分析检测。  相似文献   

8.
刘名茗  曾昭睿  王朝领  谭有金  刘华 《色谱》2003,21(5):460-463
以羟基硅油和二乙烯基苯为涂层材料 ,采用溶胶 凝胶技术和自由基引发交联的方法制备了一种新型的固相微萃取探头。采用顶空固相微萃取与气相色谱联用的方法模拟检测了水中磷酸酯和甲基磷酸酯类化合物。与商品化固相微萃取探头相比 ,该新型涂层可获得高的萃取效率。甲基膦酸二甲酯、磷酸三甲酯和磷酸三丁酯的最低检测限分别为 0 34,2 2 0和 0 0 1mg/L,相对标准偏差为 3 6 7%~ 6 4 4 % ,线性范围为 1~ 2个数量级 ,方法重现性好 ,回收率为 89 4 6 %~ 90 88%。  相似文献   

9.
用溶胶-凝胶法制备PEG-20M固相微萃取探头   总被引:9,自引:0,他引:9  
采用溶胶-凝胶方法制备了PEG-20M涂层的固相微萃取(SPME)探头并研究了它的特性。该探头具有耐温高,抗溶剂冲洗,使用寿命长的特点。由于PEG-20M的极性比较强,因此它对极性化合物如酚等有很好的萃取能力。用该探头测定了酚类物质,检出限达0.78-4.2ng/mL,线性范围为0.1-10μg/mL,相对标准偏差RSD<6%。  相似文献   

10.
三苄基杯[6]芳烃固相微萃取复合涂层的研制及其应用   总被引:2,自引:1,他引:1  
采用溶胶-凝胶方法制备了三苄基杯[6]芳烃/羟基硅油(C[6]/OH-TSO)固相微萃取(SPME)探头, 通过对多环芳烃和酞酸酯(PAEs)的分析考察了新型C[6]/OH-TSO探头的性能. 结果表明: 杯[6]芳烃SPME探头对这些非极性和弱极性的芳香化合物有很好的萃取效果和选择性, 具有耐高温、使用寿命长等特点. 建立了SPME与气相色谱-氢火焰(GC-FID)联用测定化妆品中PAEs的方法. 该方法检测限低, 重现性好(RSD<9%), 线性范围宽(2~3个数量级). 回收率在83.42%~98.85%之间.  相似文献   

11.
溶胶-凝胶固相微萃取涂层及其在农药残留分析中的应用   总被引:1,自引:0,他引:1  
利用溶胶-凝胶(sol-gel)技术制备固相微萃取(SPME)涂层材料.通过硅醇盐前驱体与涂层聚合物羟基硅油(OH-TSO)的水解共聚的方法,成功地制备了聚二甲基硅氧烷sol-gel 涂层的SPME 萃取头,并以农药的混合标准水溶液为研究对象,用直接-固相微萃取-气相色谱法(GC)对涂层的性能进行考察,制成的萃取头适用于多种农药残留的萃取分离分析.  相似文献   

12.
固相微萃取新型涂层的制备和特性(英文)   总被引:11,自引:1,他引:11  
杨敏  王一龙  曾昭睿  周莹 《色谱》2002,20(3):202-206
 以聚甲基苯基乙烯基硅氧烷为主要成分 ,采用溶胶 凝胶技术和自由基引发交联反应的方法首次制备了一种固相微萃取新涂层 ,并与气相联用 ,分析了芳香族化合物 ,考察了它的萃取性能。结果表明 :该涂层提供了大的比表面积 ,可获得高的萃取效率。与相应的商用固相微萃取涂层相比 ,该涂层具有更好的灵敏度和选择性 ,且热稳定性好 ,使用寿命长。  相似文献   

13.
Summary Poly(methylphenylvinylsiloxane) (PMPVS) coating was first prepared using sol-gel technology and applied for solid-phase microextraction (SPME). The extraction properties of the novel coating for volatile and semi-volatile organic compounds were investigated using a homemade SPME device coupled with GC-FID. The porous surface structure of the coating provided high surface area and allowed for high extraction efficiency. Compared with commercial SPME stationary phase, the new phase showed better selectivity and sensitivity toward the various analytes, due to their inherent multifunctional properties and the features of sol-gel chemistry. Furthermore, PMPVS coating showed good thermal stability and long lifetime.  相似文献   

14.
Heptakis (2,6-di-O-methyl)-β-cyclodextrin (DM-β-CD) blending with hydroxy-terminated silicone oil (OH-TSO) coated solid-phase microextraction (SPME) fiber (DM-β-CD/OH-TSO) was first prepared with sol-gel technology and applied to headspace SPME for analysis of ephedrine (EP) and methamphetamine (MA) in human urine by gas chromatography (GC). By exploiting the advantages of the unique cavity-shaped cyclic molecular structure of CD and the superiorities of sol-gel coating technique, the novel fiber showed desirable extraction ability and operational stability. Influence of relevant experimental parameters (extraction time, extraction temperature, basicity, ionic strength, etc.) was systematically investigated. In the optimal conditions the proposed headspace SPME-GC method provided good linearity over four orders of magnitude with limit of detection (LOD) of ng/ml (0.33 ng/ml for EP, 0.60 ng/ml for MA). The recoveries of EP and MA in urine were 98.0% and 98.2%. And the relative standard deviations (R.S.D., n = 6) for EP and MA were 3.9% and 5.0%, respectively.  相似文献   

15.
Fang H  Liu M  Zeng Z 《Talanta》2006,68(3):979-986
A sensitive method for determination of ephedrine derivatives using headspace solid-phase microextraction (SPME) with a novel fiber followed by capillary electrophoresis has been developed. The co-poly(butyl methacrylate/hydroxy-terminated silicone oil) (BMA/OH-TSO) was used as stationary phases with the aid of γ-methacryloxypropyltrimethoxysilane (KH-570) as bridge in SPME using sol-gel-coating method and cross-linking technology. It has high extraction efficiency for ephedrine derivatives in comparison with commercial poly(dimethylsiloxane) and poly(acrylate)-coated fiber. The coating exhibits good thermal and solvent stability as well as long lifetime. A simple and flexible device for desorption of analytes after headspace SPME was constructed. The effect of various experimental parameters for SPME (temperature, time, pH, ionic strength, desorption solvent, etc.) were discussed. Field amplified sample injection (FASI) was applied for on-line sample concentration and a sensitivity enhancement of two orders of magnitude was achieved. Linear ranges were found to be 20-5000 ng/ml. The detection limits for (1R,2S)-ephedrine, (1R,2R)-pseudoephedrine and (1S,2S)-pseudoephedrine were 3, 5 and 5 ng/ml, respectively. Relative standard deviation (n = 6) was found to be 4.96-7.57%. The method was successfully applied to the analysis of ephedrine derivatives in human urine.  相似文献   

16.
李秀娟  龚淑玲  王巍  曾昭睿 《色谱》2004,22(5):472-475
采用溶胶-凝胶方法制备了25,27-二羟基-26,28-(1′,10′-二氧代-4′,7′-二氮杂-3′,8′-二氧代亚辛基)-对-特丁基-杯[4]芳烃/羟基硅油(胺桥杯[4]/OH-TSO)固相微萃取(SPME)探头,通过对脂肪胺和芳胺的分析研究了它的特性。该探头具有耐高温、抗溶剂冲洗、使用寿命长、重现性好等特点。杯环上极性胺桥的引入增强了涂层的极性,因而在不需衍生的情况下对脂肪胺和芳胺都具有很好的萃取能力,表现出对胺类化合物的特殊选择性。脂肪胺的检出限为0.19~39.51 μg/L,线性范围达3个数  相似文献   

17.
Allyloxy bisbenzo 16-crown-5 trimethoxysilane was first used as precursor to prepare the sol-gel-derived bisbenzo crown ether/hydroxyl-terminated silicone oil (OH-TSO) SPME coating. The coating procedure involving sol solution composition and conditioning process was presented. Compared with commercial SPME stationary phases, the new coatings showed higher extraction efficiency and therefore could provide higher sensitivity for organphosphorous pesticides (OPs). Limits of detection (LODs) were in the range of 0.003-1.0 ng/g for these OPs in food samples (honey, juice, orange and pakchoi). The optimal extraction conditions of the new coatings to OPs in these samples were investigated by adjusting extraction time, salt addition, extraction temperature, and dilution ratios of samples with distilled water by using SPME coupled with gas chromatography (GC)-flame photometric detection (FPD). The method was applied to determine the concentrations of OPs in real samples.  相似文献   

18.
Three types of novel acrylate/silicone co-polymer coatings, including co-poly(methyl acrylate/hydroxy-terminated silicone oil) (MA/OH-TSO), co-poly(methyl methacrylate/OH-TSO) (MMA/OH-TSO) and co-poly(butyl methacrylate/OH-TSO) (BMA/OH-TSO), were prepared for the first time by sol-gel method and cross-linking technology and subsequently applied to headspace solid-phase microextraction (HS-SPME) of 2-chloroethyl ethyl sulfide (CEES), a surrogate of mustard, in soil. The underlying mechanisms of the coating process were discussed and confirmed by IR spectra. The selectivity of the three types of sol-gel-derived acrylate/silicone coated fibers was studied, and the BMA/OH-TSO coated fibers exhibited the highest extraction ability to CEES. The concentration of BMA and OH-TSO in sol solution was optimized, and the BMA/OH-TSO (3:1)-coated fibers possessed the highest extraction efficiency. Compared with commercially available polyacrylate (PA) fiber, the sol-gel-derived BMA/OH-TSO (3:1) fibers showed much higher extraction efficiency to CEES. Therefore, the BMA/OH-TSO (3:1)-coated fibers were chosen for the analysis of CEES in soil matrix. The reproducibility of coating preparation was satisfactory, with the RSD 2.39% within batch and 3.52% between batches, respectively. The coatings proved to be quite stable at high temperature (to 350 degrees C) and in different solvents (organic or inorganic), thus their lifetimes (to 150 times) are longer than conventional fibers. Extraction parameters, such as the volume of water added to the soil, extraction temperature and time, and the ionic strength were optimized. The linearity was from 0.1 to 10 microg/g, the limit of detection (LOD) was 2.7 ng/g, and the RSD was 2.19%. The recovery of CEES was 88.06% in agriculture soil, 92.61% in red clay, and 101.95% in sandy soil, respectively.  相似文献   

19.
A simple, sensitive, and accurate method for determination of polybrominated diphenyl ethers (PBDEs) in soil has been developed based on headspace solid-phase microextraction (HS-SPME) followed by gas chromatography–mass spectrometry (GC–MS). Permethylated-β-cyclodextrin/hydroxyl-termination silicone oil (PM-β-CD/OH-TSO) fiber was first prepared by sol–gel technology and employed in SPME procedure. By exploiting the superiorities of sol–gel coating technique and the advantages of the high hydrophobic doughnut-shaped cavity of PM-β-CD, the novel fiber showed desirable operational stability and extraction ability. After optimization on extraction conditions like water addition, extraction temperature, extraction time, salts effect, and solvents addition, the method was validated in soil samples, achieving good linearity (r > 0.999), precision (R.S.D. < 10%), accuracy (recovery > 78%), and detection limits (S/N = 3) raging from 13.0 to 78.3 pg/g.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号