首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 281 毫秒
1.
A simple and rapid method using microextraction by packed sorbent coupled with gas chromatography and mass spectrometry has been developed for the analysis of five phthalates, namely, diethyl phthalate, benzyl‐n‐butyl phthalate, dicyclohexyl phthalate, di‐n‐butyl phthalate, and di‐n‐propyl phthalate, in cold drink and cosmetic samples. The various parameters that influence the microextraction by packed sorbent performance such as extraction cycle (extract–discard), type and amount of solvent, washing solvent, and pH have been studied. The optimal conditions of microextraction using C18 as the packed sorbent were 15 extraction cycles with water as washing solvent and 3 × 10 μL of ethyl acetate as the eluting solvent. Chromatographic separation was also optimized for injection temperature, flow rate, ion source, interface temperature, column temperature gradient and mass spectrometry was evaluated using the scan and selected ion monitoring data acquisition mode. Satisfactory results were obtained in terms of linearity with R2 >0.9992 within the established concentration range. The limit of detection was 0.003–0.015 ng/mL, and the limit of quantification was 0.009–0.049 ng/mL. The recoveries were in the range of 92.35–98.90% for cold drink, 88.23–169.20% for perfume, and 88.90–184.40% for cream. Analysis by microextraction by packed sorbent promises to be a rapid method for the determination of these phthalates in cold drink and cosmetic samples, reducing the amount of sample, solvent, time and cost.  相似文献   

2.
Magnetic dispersive solid‐phase extraction followed by dispersive liquid?liquid microextraction coupled with gas chromatography/mass spectrometry was applied for the quantitative analysis of phenazopyridine in urinary samples. Magnetic dispersive solid‐phase extraction was carried out using magnetic graphene oxide nanoparticles modified by poly(thiophene‐pyrrole) copolymer. The eluting solvent of this step was used as the disperser solvent for the dispersive liquid?liquid microextraction procedure. To reach the maximum efficiency of the method, effective parameters including sorbent amount, adsorption time, type and volume of disperser and extraction solvents, pH of the sample solution, and ionic strength as well as desorption time, and approach were optimized, separately. Characterization of the synthesized sorbent was studied by utilizing infrared spectroscopy, scanning electron microscopy, and energy‐dispersive X‐ray analysis. Calibration curve was linear in the range of 0.5?250 ng/mL (R2 = 0.9988) with limits of detection and quantification of 0.1 and 0.5 ng/mL, respectively. Intra‐ and interday precisions (RSD%, n = 3) of the method were in the range of 4.6?5.4% and 4.0?5.5%, respectively, at three different concentration levels. Under the optimal condition, this method was successfully applied for the determination of phenazopyridine in human urine samples. The relative recoveries were obtained in the range of 85.0?89.0%.  相似文献   

3.
In this work, mesoporous silica (SBA‐15‐NH2) was used as an efficient adsorbent for extraction of chlordiazepoxide from different samples based on dispersive nanomaterial‐ultrasound assisted microextraction followed by high‐performance liquid chromatography. The prepared sorbent was characterized by fourier transform infrared spectroscopy, scanning electron microscopy, low‐angle X‐ray diffraction, thermal analysis, and N2 adsorption‐desorption surface area measurement. Several variables affecting the extraction efficiency of the chlordiazepoxide, including the amounts of adsorbent, time of adsorption, pH and volume of desorption solvent were optimized by central composite design combined with desirability function. The values of variables were set as 10 mg of SBA‐15‐NH2, 15 min adsorption time, pH = 7.3 and 1 mL methanol. The linear response (0.998) was obtained in the range of 0.006–10 µgmL?1 with detection limit 0.0014 µg/mL and extraction recovery was in the range of 91–96% with relative standard deviation < 6%.  相似文献   

4.
A rapid and reliable analytical method suitable for the simultaneous determination of the antiepileptic drug, oxcarbazepine and its metabolites in human plasma and saliva by means of liquid chromatography with diode array detection (DAD) has been developed. Oxcarbazepine and its metabolites (10,11-dihydro-10-hydroxycarbamazepine, trans-10,11-dihydro-10,11-dihydroxycarbamazepine and 3-hydroxycarbamazepine) were baseline separated within 6.5 min on a reversed-phase C18 column with a phosphate buffer-acetonitrile-triethylamine mixture as the mobile phase. The DAD detector was set at 240 nm. A sample preparation method for biological samples using a microextraction by packed sorbent technique has been implemented, employing a C18 sorbent inserted into a microvolume syringe and using only a small volume (25 μL) of plasma or saliva. The extraction yield values were satisfactory for all analytes (>86.5%) as well as the precision data, which were always in the low percentage of relative standard deviation values (<4.6%). The method was successfully applied to both plasma and saliva samples drawn from psychiatric and neurological patients undergoing treatment with oxcarbazepine (Tolep®) tablets.  相似文献   

5.
Chloroanisoles, particularly 2,4,6‐trichloroanisole, are commonly identified as major taste and odor compounds in water. In the present study, a simple and efficient method was established for the simultaneous determination of chloroanisoles and the precursor 2,4,6‐trichlorophenol in water by using low‐density‐solvent‐based simultaneous dispersive liquid–liquid microextraction and derivatization followed by gas chromatography with electron capture detection. 2,4‐Dichloroanisole, 2,6‐dichloroanisole, 2,4,6‐trichloroanisole, 2,3,4‐trichloroanisole, and 2,3,6‐trichloroanisole were the chloroanisoles evaluated. Several important parameters of the extraction‐derivatization procedures, including the types and volumes of extraction solvent and disperser solvent, concentrations of derivatization agent and base, salt addition, extraction‐derivatization time, and temperature were optimized. Under the optimized conditions (80 μL of isooctane as extraction solvent, 500 μL of methanol as disperser solvent, 60 μL of acetic anhydride as derivatization agent, 0.75% of Na2CO3 addition w/v, extraction‐derivatization temperature of 25°C, without salt addition), a good linearity of the calibration curve was observed by the square of correlation coefficients (R2) ranging from 0.9936 to 0.9992. Repeatability and reproducibility of the method were < 4.5% and <7.3%, respectively. Recovery rates ranged from 85.2 to 101.4%, and limits of detection ranged from 3.0 to 8.7 ng/L. The proposed method was applied successfully for the determination of chloroanisoles and 2,4,6‐trichlorophenol in water samples.  相似文献   

6.
This study describes the synthesis and application of a magnetic amino‐functionalized hollow silica‐titania microsphere as a new sorbent for magnetic dispersive micro‐solid phase extraction of selected pesticides in coffee bean samples. The sorbent was fully characterized by Fourier‐transform infrared spectroscopy, field emission scanning electron microscopy, transition electron microscopy, energy‐dispersive X‐ray spectroscopy, and vibrating sample magnetometry techniques. Significant extraction parameters affecting the proposed method, such as extraction time, sorbent amount, sample solution pH, salt amount, and desorption conditions (desorption solvent and time) were investigated and optimized. All the figures of merits were validated in coffee bean samples under the matrix‐matched calibration method. Linear dynamic ranges were 5–250 µg/kg with the determination coefficients (R2) > 0.9980. The limits of detection for the pesticides of chlorpyrifos, malathion, hexaconazole, and atrazine were 1.42, 1.43, 1.35, and 1.33 µg/kg, respectively. Finally, the method was successfully applied for the determination of the pesticides in green and roasted coffee bean samples, and the obtained recoveries were in the range of 74–113% for spiked samples. The prepared sorbent could be used for the magnetic dispersive micro‐solid phase extraction of pesticides in the plant‐derived food matrix.  相似文献   

7.
In the present study, a natural sorbent based micro-solid phase extraction (μ-SPE) was developed for determination of phthalate esters in milk samples. For the first time, an efficient and cost effective natural material (seed powder of Moringa oleifera) was employed as sorbent in μ-SPE. The sorbent was found to be naturally enriched with variety of functional groups and having a network of interconnected fibers. This method of extraction integrates different steps such as removal of proteins and fatty stuff, extraction and pre-concentration of target analytes into a single step. Thirteen phthalate esters were selected as target compounds for the development and evaluation of method. Some key parameters affecting the extraction efficiency were optimized, including selection of membrane, selection and amount of sorbent, extraction time, desorption solvent, volume of desorption solvent, desorption time and effect of salt addition. Under the optimum conditions, very good linearity was achieved for all the analytes with coefficient of determinations (R2) ranging between 0.9768 and 0.9977. The limits of detection ranged from 0.01 to 1.2 μg L−1. Proposed method showed satisfactory reproducibility with relative standard deviations ranging from 3.6% to 10.2% (n = 7). Finally, the developed method was applied to tetra pack and bottled milk samples for the determination of phthalate esters. The performance of natural sorbent based μ-SPE was better or comparable to the methods reported in the literature.  相似文献   

8.
A novel analytical approach has been developed for the determination of selected drugs (milrinone, enalapril, carvedilol, spironolactone, acenocumarol, ticlopidine, cilazapril) and their metabolites (2‐oxoticlopidine, cilazaprilat, canrenone, 5′‐hydroxycarvedilol, O‐desmethyl‐carvedilol, enalaprilat) in human urine, based on a miniaturized extraction technique; semiautomatic microextraction by packed sorbent, using a new digitally controlled syringe, followed by ultra high pressure liquid chromatography separation combined with UV detection. During method optimization, the extraction parameters as the type of sorbent material, type and volume of elution solution, number of extraction cycles, volume and pH of sample, type and volume of washing solution were studied. The chromatographic separation of the target analytes was performed with a core–shell analytical column using 0.05% trifluoroacetic acid in water and acetonitrile in gradient elution mode. The limits of quantification ranged from 0.016 to 0.045 μg/mL. Under the optimized conditions, extraction efficiency was higher than 70.1% for drugs and their metabolites. Due to its simplicity and speed, this method was successfully applied to the quantitation of selected compounds in urine samples.  相似文献   

9.
By synthesizing a molecular imprinted polymer as an efficient adsorbent, ciprofloxacin was micro‐extracted from seawater, human blood plasma and tablet samples by pipette‐tip micro solid phase extraction and determined spectrophotometrically. Response surface methodology was applied with central composite design to build a model based on factors affecting on microextraction of ciprofloxacin; including volume of eluent solvent, number of extraction cycles, number of elution cycles, and pH of sample. Other factors that affect extraction efficiency, such as type of eluent solvent, volume of sample, type, and amount of salt were optimized with one‐variable‐at‐a‐time method. Under optimum extraction condition, pH of sample solution was 7.0, volume of eluent solvent (methanol) was 200 µL, volume of sample solution was 10 mL, and the number of extraction and elution cycles was five and seven, respectively, amount of Na2SO4 (as salt) and MIP (as sorbent) were optimized at 150 and 2 mg, respectively. The linear range of the suggested method under optimum extraction factors was 5–150 µg/L with a limit of detection of 1.50 µg/L for the analyte. Reproducibility of the method (as relative standard deviation) was better than 7%.  相似文献   

10.
A vortex-assisted dispersive micro-solid-phase extraction procedure using a new and green sorbent was developed as a simple, fast, and efficient sample preparation method for the extracting five pesticides in several fruit juice samples. In this study, for the first time, riboflavin was used as an efficient sorbent. A few milligrams of riboflavin was directly added into the aqueous solution containing the analytes to adsorb them. After adsorption the analytes, they were desorbed and more concentrated by a dispersive liquid–liquid microextraction procedure. The influence of several effective parameters such as amount of riboflavin, pH, vortex time, eluent nature and volume, and extraction solvent type and volume on the extraction efficiency was investigated. In optimal conditions, linear ranges of the calibration curves were broad. The limits of detection and quantification were attained in the ranges of 0.56–1.5  and 1.9–0.52 ng mL−1, respectively. The proposed method demonstrated to be suitable for concurrent extraction of the studied pesticides in various fruit juice samples with high enrichment factors (320–360) and precision (relative standard deviation ≤7.8% for intra- [n = 6] and interday [n = 4] precisions at a concentration of 25 ng mL−1 of each pesticide).  相似文献   

11.
Switchable‐hydrophilicity solvent liquid‐liquid microextraction and dispersive liquid‐liquid microextraction were compared for the extraction of piperine from Piper nigrum L. prior to its analysis by using high‐performance liquid chromatography with UV detection. Under optimum conditions, limits of detection and quantitation were found as 0.2–0.6 and 0.7–2.0 μg/mg with the two methods, respectively. Calibration graphs showed good linearity with coefficients of determination (R2) higher than 0.9962 and percentage relative standard deviations lower than 6.8%. Both methods were efficiently used for the extraction of piperine from black and white pepper samples from different origins and percentage relative recoveries ranged between 90.0 and 106.0%. The results showed that switchable‐hydrophilicity solvent liquid‐liquid microextraction is a better alternative to dispersive liquid‐liquid microextraction for the routine analysis of piperine in food samples. A novel scaled‐up dispersive liquid‐liquid microextraction method was also proposed for the isolation of piperine providing a yield of 102.9 ± 4.9% and purity higher than 98.0% as revealed by NMR spectroscopy.  相似文献   

12.
The sublingual combination of buprenorphine and naloxone (Suboxone®) and Methadone Maintenance Therapy have been found effective in treating heroin addiction. A new analytical method suitable for the simultaneous determination of buprenorphine, norbuprenorphine, methadone and naloxone in human plasma by means of liquid chromatography with coulometric detection has been developed. The chromatographic separation was achieved with a phosphate buffer–acetonitrile mixture as the mobile phase on a cyano column. The monitoring cell of the coulometric detector was set at an oxidation potential of +0.600 V. A rapid clean-up procedure of the biological samples using a microextraction by packed sorbent technique has been implemented, employing a C8 sorbent inserted into a syringe needle. The extraction yield values were satisfactory for all analytes (>85%). The calibration curves were linear over a range of 0.25–20.0 ng mL−1 for buprenorphine and norbuprenorphine, 3.0–1000.0 ng mL−1 for methadone and 0.13–10.0 ng mL−1 for naloxone. The sensitivity was also high with limits of detection of 0.08 ng mL−1 for both buprenorphine and norbuprenorphine, 0.9 ng mL−1 for methadone and 0.04 ng mL−1 for naloxone. The intraday and interday precision data were always satisfactory.The method was successfully applied to plasma samples obtained from former heroin addicts treated with opioid replacement therapy.  相似文献   

13.
A simultaneous derivatization/air‐assisted liquid–liquid microextraction technique has been developed for the sample pretreatment of some parabens in aqueous samples. The analytes were derivatized and extracted simultaneously by a fast reaction/extraction with butylchloroformate (derivatization agent/extraction solvent) from the aqueous samples and then analyzed by GC with flame ionization detection. The effect of catalyst type and volume, derivatization agent/extraction solvent volume, ionic strength of aqueous solution, pH, numbers of extraction, aqueous sample volume, etc. on the method efficiency was investigated. Calibration graphs were linear in the range of 2–5000 μg/L with squared correlation coefficients >0.990. Enhancement factors and enrichment factors ranged from 1535 to 1941 and 268 to 343, respectively. Detection limits were obtained in the range of 0.41–0.62 μg/L. The RSDs for the extraction and determination of 250 μg/L of each paraben were <4.9% (n = 6). In this method, the derivatization agent and extraction solvent were the same and there is no need for a dispersive solvent, which is common in a traditional dispersive liquid–liquid microextraction technique. Furthermore, the sample preparation time is very short.  相似文献   

14.
Nitrogen doped nano porous graphene was used as an efficient sorbent in solid‐phase extraction process for simultaneous separation and pre‐concentration of metal ions lead (II), cadmium(II), and chromium(III)) in biological samples. Ultrasonic assisted in‐syringe dispersive micro solid phase extraction coupled with micro sampling atomic absorption spectrometry was utilized for the determination of metal ions. Nitrogen doped nano porous graphene was synthesized as a nano sorbent by chemical vapour deposition method. Methane and aniline were used as carbon and nitrogen sources. The characterization of sorbent was performed by field emission scanning electron microscope, transmission electron microscopy, atomic force microscope, fourier transform infrared, chemical element analysis and raman analysis. Effective parameters on the extraction efficiency such as pH, sorbent dosage, eluent volume and eluent concentration were optimized by central composite design and desirability function. Experimental results indicate that the optimal conditions for this extraction were pH = 6.4, 1.42 mg of sorbent, 100 μL of eluent, and 0.84 mol L‐1 of eluent concentration. The detection limits are as low as 1.5, 0.3 and 0.9 μg L‐1 for lead, cadmium, and chromium, respectively. The intra‐day precisions were 3.6, 4.38 and 2.94 and Inter‐day precision were 4.83, 5.26 and 4.52 for lead, cadmium, and chromium, respectively. Method performance was investigated by determination of mentioned heavy metals in complicated biological matrixes such as human plasma, urine and saliva samples with good recoveries.  相似文献   

15.
In the present study, a novel configuration of liquid‐phase microextraction was proposed, in which a magnetic stirrer with a groove was used as the extractant phase holder. It was termed as magnetic stirrer liquid‐phase microextraction. In this way, the stability of the organic solvent was much improved under high stirring speed; the extraction efficiency was enhanced due to the enormously enlarged contact area between the organic solvent and aqueous phase. The extraction performance of the magnetic stirrer liquid‐phase microextraction was studied using chlorobenzenes as the probe analytes. A wide linearity range (20 pg/mL to 200 ng/mL) with a satisfactory linearity coefficient (r2 > 0.998) was obtained. Limits of detection ranged from 9.0 to 12.0 pg/mL. Good reproducibility was achieved with intra‐ and inter‐day relative standard deviations <4.8%. The proposed magnetic stirrer liquid‐phase microextraction was simple, environmentally friendly and efficient; compared to single‐drop microextraction, it had obvious advantages in terms of reproducibility and extraction efficiency. It is a promising miniaturized liquid‐phase technology for real applications.  相似文献   

16.
An analytical method is presented for the determination of paraben preservatives in semisolid cream samples by matrix solid‐phase dispersion combined with supramolecular solvent‐based microextraction. Due to the oily and sticky nature of the sample matrix, parabens were first extracted from the samples by matrix solid‐phase dispersion using silica as sorbent material with a clean‐up performed with tetrahydrofuran in the elution step. The eluate (500 μL), 1‐decanol (120 μL), and water (4.4 mL) were then mixed in a polyethylene pipette to form supramolecular solvent. Finally, the analytes in the supramolecular solvent were separated and determined by liquid chromatography with ultraviolet detection. Under optimal extraction conditions, the extraction recoveries of the studied compounds were obtained in the range of 63–83%. The limits of detection for the analytes were between 0.03 and 0.04 μg/g. The precision of the method varied between 4.0–6.7 (intraday) and 6.2–7.9% (interday). Finally, the optimized procedure was applied to the determination of the target preservatives in a variety of cream samples (diaper rash, skin allergy, face and hand moisturizing) with satisfactory recoveries (86–102%).  相似文献   

17.
A simple, fast, and sensitive analytical protocol using fabric‐phase sorptive extraction followed by high performance liquid chromatography with ultraviolet detection has been developed and validated for the extraction of five parabens including methylparaben, ethylparaben, propylparaben, butylparaben, and benzylparaben. In the present work, sol‐gel polyethylene glycol coated fabric‐phase sorptive extraction membrane is used for the preconcentration of parabens (polar) from complex matrices. The use of fabric‐phase sorptive extraction membrane provides a high surface area which offers high sorbent loading, shortened equilibrium time, and overall decrease in the sample preparation time. Various factors affecting the performance of fabric‐phase sorptive extraction, including extraction time, eluting solvent, elution time, and pH of the sample matrix, were optimized. Separation was performed using a mobile phase consisting of water:acetonitrile (63:37; v/v) at an isocratic elution mode at a flow rate of 0.9 mL/min with wavelength at 254 nm. The calibration curves of the target analytes were prepared with good correlation coefficient values (r2 > 0.9955). The limit of detection values range from 0.252 to 0.580 ng/mL. Finally, the method was successfully applied to various cosmetics and personal care product samples such as rose water, deodorant, hair serum, and cream with extraction recoveries ranged between 88 and 122% with relative standard deviation <5%.  相似文献   

18.
In this work, the microextraction in packed syringe technique combined with corona discharge ion mobility spectrometry was used for determining diazinon in water samples. A new porous composite of nanoclay and polysiloxane was prepared using a sol–gel process. An amount of 2.0 mg of the sorbent was packed in a 250 μL syringe and used for extraction. A volume of 2 mL of the sample was passed through the sorbent bed, and the entrapped analyte was eluted by 25 μL of methanol. Important parameters influencing the extraction performance were investigated. Under optimum experimental conditions, the detection limit for diazinon was 0.07 ng/mL. The intra‐ and inter‐day relative standard deviations were 5.0 and 12.3%, respectively. The calibration curve was linear in the concentration range from 0.2 to 20.0 ng/mL (r= 0.999). The applicability of the method was demonstrated by analyzing spiked real water samples and the spiking recoveries were in the range of 95 to 106%.  相似文献   

19.
A simple, rapid, sensitive, and environmentally friendly method, based on modified dispersive liquid–liquid microextraction coupled with high‐performance liquid chromatography was developed for the simultaneous determination of five biogenic amines in fermented food samples. Biogenic amines were derivatized with 9‐fluorenylmethyl chloroformate, extracted by vortex‐assisted surfactant‐enhanced emulsification liquid–liquid microextraction, and then analyzed by high‐performance liquid chromatography. Five biogenic amine compounds were separated within 30 min using a C18 column and gradient elution with acetonitrile and 1% acetic acid. Factors influencing the derivatization and extraction efficiency such as type and volume of extraction solvent, type, and concentration of surfactant, pH, salt addition, and vortex time were optimized. Under the optimum conditions, the method provided the enrichment factors in the range of 161–553. Good linearity was obtained from 0.002–0.5 mg/L for cadaverine and tyramine, 0.003–1 mg/L for tryptamine and histamine, and 0.005–1 mg/L for spermidine with coefficient of determination (R2) > 0.992. The limits of detection ranged from 0.0010 to 0.0026 mg/L. The proposed method was successfully applied to analysis of biogenic amines in fermented foods such as fermented fish (plaa‐som), wine and beer where good recoveries were obtained in the range of 83.2–112.5%  相似文献   

20.
The biomonitoring of hydroxy polycyclic aromatic hydrocarbons in urine, as a direct way to access multiple exposures to polycyclic aromatic hydrocarbons, has raised great concerns due to their increasing hazardous health effects on humans. Solid‐phase extraction is an effective and useful technique to preconcentrate trace analytes from biological samples. Here, we report a novel solid‐phase extraction method using a graphene oxide incorporated monolithic syringe for the determination of six hydroxy polycyclic aromatic hydrocarbons in urine coupled with liquid chromatography‐tandem mass spectrometry. The effect of graphene oxide amount, washing solvent, eluting solvent, and its volume on the extraction performance were investigated. The fabricated monoliths gave higher adsorption efficiency and capacity than the neat polymer monolith and commercial C18 sorbent. Under the optimum conditions, the developed method provided the detection limits (S/N = 3) of 0.02–0.1 ng/mL and the linear ranges of 0.1–1500 ng/mL for six analytes in urine sample. The recoveries at three spiked levels ranged from 77.5 to 97.1%. Besides, the intra column‐to‐column (n = 3) and inter batch‐to‐batch (n = 3) precisions were ≤ 9.8%. The developed method was successfully applied for the determination of hydroxy polycyclic aromatic hydrocarbons in urine samples of coke oven workers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号