首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   28篇
  免费   4篇
化学   32篇
  2016年   2篇
  2015年   6篇
  2014年   5篇
  2013年   1篇
  2012年   2篇
  2011年   5篇
  2010年   4篇
  2009年   1篇
  2007年   3篇
  2006年   1篇
  2002年   2篇
排序方式: 共有32条查询结果,搜索用时 247 毫秒
1.
2.
Vortex‐assisted dispersive liquid–liquid microextraction using methyl benzoate as an alternative extraction solvent for extracting and preconcentrating three benzimidazole fungicides (i.e., carbendazim, thiabendazole, and fluberidazole) in environmental water samples before high‐performance liquid chromatographic analysis has been developed. The selected microextraction conditions were 250 μL of methyl benzoate containing 300 μL of ethanol, 1.0% w/v sodium acetate, and vortex agitation speed of 2100 rpm for 30 s. Under optimum conditions, preconcentration factors were 14.5–39.0 for the target fungicides. Limits of detection were obtained in the range of 0.01–0.05 μg/L. The proposed method was then applied to surface water samples and the recovery evaluations at three spiked concentration levels of 5, 30, and 50 μg/L were obtained in the range of 77.4–110.9% with the relative standard deviation <7.4%. The present method was simple, rapid, low cost, sensitive, environmentally friendly, and suitable for the trace analysis of the studied fungicides in environmental water samples.  相似文献   
3.
A simple, rapid, sensitive, and environmentally friendly method, based on modified dispersive liquid–liquid microextraction coupled with high‐performance liquid chromatography was developed for the simultaneous determination of five biogenic amines in fermented food samples. Biogenic amines were derivatized with 9‐fluorenylmethyl chloroformate, extracted by vortex‐assisted surfactant‐enhanced emulsification liquid–liquid microextraction, and then analyzed by high‐performance liquid chromatography. Five biogenic amine compounds were separated within 30 min using a C18 column and gradient elution with acetonitrile and 1% acetic acid. Factors influencing the derivatization and extraction efficiency such as type and volume of extraction solvent, type, and concentration of surfactant, pH, salt addition, and vortex time were optimized. Under the optimum conditions, the method provided the enrichment factors in the range of 161–553. Good linearity was obtained from 0.002–0.5 mg/L for cadaverine and tyramine, 0.003–1 mg/L for tryptamine and histamine, and 0.005–1 mg/L for spermidine with coefficient of determination (R2) > 0.992. The limits of detection ranged from 0.0010 to 0.0026 mg/L. The proposed method was successfully applied to analysis of biogenic amines in fermented foods such as fermented fish (plaa‐som), wine and beer where good recoveries were obtained in the range of 83.2–112.5%  相似文献   
4.
A simple and automated method involving in-capillary derivatization and in-capillary preconcentration was developed for the simultaneous determination of metal ions by capillary zone electrophoresis. Fe(II), Zn(II), Cu(II) and Cd(II) were derivatized using 1,10-phenanthroline as the derivatizing agent. The in-capillary derivatization and in-capillary preconcentration via large volume injection were performed sequentially as follows: 60 mmol L?1 1,10-phenanthroline was first hydrodynamically injected (0.2 psi) for 2 s; metal ions were introduced by hydrodynamic injection (0.5 psi) for 60 s; 0.2 mol L?1 acetate pH 5.5 containing 20 % methanol was used as the running buffer. Four metal ions can be determined within 8 min using 16 kV. The resulting preconcentration factors were in the range 12–21. Good linearity was obtained for concentrations of 0.1–8.0 mg L?1 (r 2 > 0.990). The mean recoveries of the metal ions evaluated by fortification of wine samples were in the range 90–102 %. The limits of detection ranged from 0.05 to 0.2 mg L?1. The proposed method can be applied for directly determining metal ions in wine samples.  相似文献   
5.
A simple and rapid method for preconcentration of carbamate insecticides, including methomyl, propoxur, carbofuran, carbaryl, isoprocarb, methiocarb and promecarb, has been developed. It was based on a liquid-liquid microextraction using a [C4MIM][PF6] room temperature ionic liquid as an extraction solvent prior to analysis by high performance liquid chromatography with UV detection. Experimental parameters affecting the extraction performance, such as the volumes of sample, extractant and dissolving solvent, and extraction time, were studied. Under the selected conditions, the enrichment factors in the range between 10 and 25 could be achieved with the limit of detection in the range of 2-40 μg L−1, and with the relative standard deviations of lower than 0.6 and 10.2% for retention time and peak area, respectively. The proposed method offers advantages in reduction of the exposure danger to toxic solvents used in the conventional liquid-liquid extraction, simplicity of the extraction processes, rapidity, and sensitivity enhancement. The method was demonstrated to apply to the analysis of fruit and natural surface water samples.  相似文献   
6.
Reversed phase liquid chromatography using UV detection was developed for the simultaneous analysis of Hg(II), Pb(II), Cd(II), Ni(II), Fe(III) and V(V) ions after their complexation with pyrrolidine-dithiocarbamate (PDC). Optimum chromatographic conditions were a μ-Bondapak C18 column and an isocratic mobile phase consisting of 40 mmol L?1 SDS, 34 mmol L?1 TBABr and 68% acetonitrile in 10 mmol L?1 phosphate buffer pH 3.5. The separation of six PDC complexes was achieved within 8 min. Analytical performances and method validation were investigated. The detection limits ranged from 0.16 μg L?1(Fe(III)) to 5.40 μg L?1(Pb(II)). Recoveries obtained for all the studied samples including tap water, whole blood and vegetables were 72–98%. The results obtained from the proposed method were not significantly different compared to those obtained from atomic absorption spectrometry (P = 0.05).  相似文献   
7.
The common SDS microemulsion (i.e. 3.3% SDS, 0.8% octane, and 6.6% butanol) and organic solvents were investigated for the stacking of cationic drugs in capillary zone electrophoresis using a low pH separation electrolyte. The sample was prepared in the acidic microemulsion and a high percentage of organic solvent was included in the electrolyte at anodic end of capillary. The stacking mechanism was similar to micelle to solvent stacking where the micelles were replaced by the microemulsion for the transport of analytes to the organic solvent rich boundary. This boundary is found between the microemulsion and anodic electrolyte. The effective electrophoretic mobility of the cations reversed from the direction of the anode in the microemulsion to the cathode in the boundary. Microemulsion to solvent stacking was successfully achieved with 40% ACN in the anodic electrolyte and hydrodynamic sample injection of 21 s at 1000 mbar (equivalent to 30% of the effective length). The sensitivity enhancement factors in terms of peak height and corrected peak area were 15 to 35 and 21 to 47, respectively. The linearity R2 in terms of corrected peak area were >0.999. Interday precisions (%RSD, n = 6) were 3.3–4.0% for corrected peak area and 2.0–3.0% for migration time. Application to spiked real sample is also presented.  相似文献   
8.
9.
A mixed anionic–cationic surfactant cloud point extraction (CPE) has been developed using sodium dodecyl sulfate (SDS) and tetrabutylammonium bromide (TBABr) for the extraction and preconcentration of organophosphorus pesticides (OPPs) at ambient temperature before analysis by high-performance liquid chromatography. The studied OPPs were azinphos-methyl, parathion-methyl, fenitrothion, diazinon, chlorpyrifos, and prothiophos. The optimum conditions of the mixed anionic–cationic CPE were 50 mmol L−1 SDS, 100 mmol L−1 TBABr, and 10% (w/v) NaCl. The extracted OPPs were successfully separated within 11 min using the conditions of a Waters Symmetry C8 column, a flow rate of 0.8 mL min−1, a gradient elution of methanol and water, and detection at 210 nm. Linearity was found over the range 0.05–5 μg mL−1, with the correlation coefficients higher than 0.996. The enrichment factor of the target analytes was in the range 6–11, which corresponds to their limits of detection from 1 to 30 ng mL−1. High precisions (intra-day and inter-day) were obtained with relative standard deviation <1.5% (t R) and 10% (peak area). Accuracies (% recovery) of the different spiked OPP concentrations were 82.7–109.1% (water samples) and 80.3–113.3% (fruit juice samples). No contamination by the OPPs was observed in any studied samples.  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号