首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 21 毫秒
1.
A method for preparation of a stationary phase-adjustable column with in-column stationary phase-coated fused-silica fiber annular column was successfully developed. The surface of a 0.12 mm o.d. bare optical fiber was first coated with a stationary phase and then inserted into a fused-silica capillary (non-coated or coated) as an annular column for gas chromatographic study. The optical fiber and capillary were coated with polydimethylsiloxane (SE-30) and polyethylene glycol 20M (PEG-20M) as nonpolar and polar stationary phases, respectively. Among the investigated annular and open tubular columns, the PEG-20M-coated fiber-in-PEG-20M-coated capillary annular column showed the highest column efficiency with a minimum plate height of 0.35 mm and an optimum gas velocity of 25 cm/s. When a SE-30/PEG-20M-coated fiber-in-uncoated capillary annular column was applied to separate a 9-component complex mixture, the total analysis time was 5.3 min and the column length was 12 m. By contrast, when a SE-30-coated fiber-in-PEG-20M-coated capillary annular column was used to separate the same 9-component mixture, the analysis time was reduced to 3.5 min and the column length was shortened by half to 6 m. Our results show that the stationary phase-coated fiber-in-stationary phase-coated capillary annular column is a better choice for gas chromatographic separation as it is more efficient and flexible. In addition, the proposed annular column design provides flexibility in using two or even more types of stationary phases to achieve optimal analytical separation.  相似文献   

2.
Molecular organic cages as shape-persistent organic molecules with permanent and accessible cavities have attracted a lot of interest because of their importance as host-guest systems. Herein, we report a chiral porous organic cage (POC) CC9 diluted with a polysiloxane OV-1701 to fabricate a CC9-coated capillary column, which was used for the high-resolution gas chromatographic separation of organic compounds, including positional isomers and racemates. On the CC9-coated capillary column, a large number of racemic compounds such as chiral alcohols, esters, ethers and epoxides can be resolved without derivatization. By comparing the chiral recognition ability of the CC9-coated column with the commercially available β-DEX 120 column and the POC CC3-R coated column recently reported by our group, the CC9-coated column offered good resolution during the separation of some racemates, that were not separated using the β-DEX 120 column or POC CC3-R coated column. Therefore, the CC9-coated column can be complementary to the β-DEX 120 column and CC3-R coated column. The results indicated that the CC9-coated column exhibited great potential for application in the separation of positional isomers and enantiomers with great selectivity, high resolution and good reproducibility.  相似文献   

3.
The study evaluates the influence of selectivity tuning of the stationary phase of the second dimension on the orthogonality of a comprehensive two-dimensional gas chromatography (GC x GC) system. Two different sets of columns, providing independent and semi-independent separation mechanisms were used. The first consisted of a first dimension separating analytes on a volatility basis (i.e. a non-polar polydimethylsiloxane (OV1) column) combined with a second dimension separating by polarity, using columns coated with 100% polyethylene glycol (CW20M), CW20M/OV1 mixtures in ratios of 25-75%, and polydimethylsiloxane, 7% phenyl, 7% cyanopropyl (OV1701). The second set consisted of a first dimension separating analytes on a polarity basis (100% CW20M column) combined with a second dimension separating by volatility, consisting of columns coated with 100% OV1, OV1/CW20M mixtures in ratios of 25-75%, and 100% OV1701. Medium-complexity mixtures of natural origin (i.e. peppermint essential oil and a standard mixture of suspected allergens) consisting of components in a relatively limited range of molecular weights (MW) and volatilities, but belonging to different classes of compounds in a wide range of polarity (mono- and sesquiterpenoids, hydrocarbons and oxygenated compounds) were analysed with the above sets of columns. Different approaches were used to evaluate peak spreading on the GC x GC separation plane and degree of orthogonality of the column sets, namely: (1) a Factor Analysis (FA) approach, estimating the correlation coefficients and spreading angles of the sample components in the two-dimensional chromatographic plane; (2) an Informational Theory (IT) approach, based on determining a group of parameters including: informational entropy, % synentropy and similarity (H); and (3) an approach based on estimating the amount of separation space used, i.e. a practical parameter that directly refers to the experimental separation plane of the GC x GC chromatogram. Results showed that peak spreading in the chromatographic plane, when CW20M and OV1 are combined in different ratios, can be predicted from retention mechanisms, and that the degree of orthogonality measured with different approaches, is consistent with the divergent nature, in terms of polarity of the stationary phases combined in the GC x GC system.  相似文献   

4.
A technique for adhesion of fine particles (ca. 5 μ) of the 405 white diatomaceous support on the inner wall of glass tube with organic glue [poly (diethylaminoethyl methacrylate) acetate] is described. The coated tube was drawn to capillary column by using a machine designed according to Desty's. The capillary column was then coated with stationary phase (such as squaiane, QF-1, Dexsil 300, PEG 20 M, OV-1, SE 30 and etc.) by the conventional dynamic or static method. This preparation method has proved easy to duplicate and is simple. The coating efficiency (UTE %) is within 60–90. The theoretical plate number per meter of an SE 30 column is about 4000, and per meter of a PEG 20 M column is about 2500. The columns thus prepared have been successfully used to analyze petroleum hydrocarbons, essential oils, petrochemicals, pheromone, steroid metabolites and others.  相似文献   

5.
Chiral covalent organic frameworks(CCOFs) featuring chirality, stability, and good porosity have attracted a considerable amount of attention due to their important applications, such as asymmetric catalysis, chiral separation, and chiral recognition. In this study, a β-cyclodextrin(β-CD) covalent organic framework(β-CD-COF) diluted with polysiloxane OV-1701 was explored as a novel chiral stationary phase(CSP) for gas chromatography(GC) separation of racemates. The β-CD-COF coated capillary colu...  相似文献   

6.
A series of OV1-OV1701 column sets, in which the two dimensions differ in id and/or film thickness, were adopted to separate components of the volatile and semivolatile fraction of samples of plant origin. In particular two applications are presented: a target analysis approach to determine volatile suspected allergens in a medium-complexity fragrance and in sandalwood essential oil, and a fingerprint analysis approach to compare herbal extracts. Some basic chromatographic parameters of these combinations, i. e. net separation measure (S(GC x GC)), degree of orthogonality and a suitable number of modulations per peak, were also estimated by analysing two test mixtures: FAME (C4:0-C24:0) and suspected volatile allergens. Experimental results show that 0.25 mm homologous id column combination, despite their lower separation power, have good capacity to separate and resolve medium-to-complex fractions from samples of plant origin, demonstrating: (i) good system orthogonality, maximized through proper exploitation of stationary-phase selectivity and (ii) reduced 2-D column overloading effects due to the increased 2-D mass loadability, thus facilitating the analysis of mixtures whose components differ significantly in relative abundance.  相似文献   

7.
Microporous organic networks (MONs) are a new class of porous materials synthesized via Sonogashira coupling reactions between organic building blocks. Here we report an in situ synthesis approach to fabricate MONs coated capillary column for high resolution GC separation of hydrocarbons. The McReynolds constant evaluation reveals the MONs coated capillary is a non‐polar column. The MONs coated capillary column shows good resolution for GC separation of diverse important industrial hydrocarbons such as linear and branched alkanes, alkylbenzenes, pinene isomers, ethylbenzene and styrene, cyclohexane and benzene. The MONs coated capillary column gave a high column efficiency of 1542 plates per meter for hexane and good precision for replicate separations of the selected hydrocarbons with the RSDs of 0.2–0.3, 1.5–3.1, and 1.9–3.3% for retention time, peak height and peak area, respectively. The MONs coated capillary also offered better resolution than commercial Inert Cap‐1 and Inert Cap‐5 capillary columns for hexane and heptane isomers. These results reveal the potential of MONs as novel stationary phases in GC.  相似文献   

8.
As a continuation of previous studies on the use of cyclodextrin derivatives (CD) for the separation of volatile compounds by capillary GC, the influence of diluting phases other than OV-1701 or OV-1701-OH has been investigated. 2,6-Di-O-methyl-3-O-pentyl-β-cyclodextrin (2,6-DiMe-3-Pe-β-CD) was taken as the reference CD derivative, because of the large number of volatile racemates it is able to separate; OV-1701 or OV-1701-OH was chosen as the reference diluting phase. The performance of a column coated with a 0.15 μm film of 10 % 2,6-DiMe-3-Pe-β-CD in OV-1701 was compared with that of analogous columns coated with films of the same thickness containing the same percentage of the CD derivative diluted with stationary phases of different polarity, i.e. PS-086, PS-347.5, and OV-225. Resolution values and separation factors of thirty racemates were used to evaluate the effect of different diluting phases on column performance.  相似文献   

9.
Zhang G  Li Y  Fang Y  Han N  Xu B 《Electrophoresis》2003,24(4):693-699
Octadecyl silyl silica (ODS) phase coated with immobilized polysiloxanes (OV1701, SE-54, SE-30) were synthesized, their characteristics as capillary electrochromatography (CEC) column packing materials were studied. It was found that, although the polysiloxane coatings were different in polarity, the resulting packing materials showed the highest efficiencies when the respective coating ratios (polysiloxane:ODS, w/w) were all 20-30%. As expected, packing materials coated with different polysiloxanes resulted in different selectivity on solute pairs. Separations on these stationary phases were studied with different factors such as pH values and acetonitrile contents of the mobile phases. It was found that all these kind of stationary phases could resist basic mobile phase with a pH value as high as 11.6. Tests were made to analyze polar, basic drugs with CEC using the stationary phases.  相似文献   

10.
The separation properties of different chromatographic methods regarding the enantioselective separation of axially chiral (atropisomeric) polybrominated biphenyls (PBB) were studied. For this purpose, the technical hexabromobiphenyl product Firemaster BP-6 was characterised by gas-chromatography coupled to electron capture detection (GC/ECD) and electron-capture negative ion mass spectrometry (GC/ECNI-MS) as well as by liquid chromatographic fractionating on active carbon and celite. Twelve individual PBBs including potential atropisomeric PBBs were isolated from Firemaster BP-6 by reversed-phase high-performance liquid chromatography (HPLC) on three serially coupled octadecylsilane columns. Six of the 12 isolated PBBs (three tri-ortho and di-ortho substituted PBBs, respectively) were separated into atropisomers on a HPLC column containing permethylated beta-cyclodextrin on silica. Moreover, the temperature dependency of the enantiomer separations is discussed. Gas chromatographic enantiomer separation of PBBs is a very demanding task due to high elution temperatures. However, the atropisomers of one tri-ortho substituted PBB congener (PBB 149) could be resolved on a column coated with randomly modified heptakis(6-O-tert.-butyldimethylsilyl-2,3-di-O-methyl)-beta-cyclodextrin in OV 1701.  相似文献   

11.
GC/MS法测定木香挥发油化学成分   总被引:5,自引:0,他引:5  
用气相色谱-质谱法对木香挥发油进行化学成分的分析。采用水蒸气馏法从木香中提取挥发油。试用不同类型的毛细管柱进行分析,找出最佳分析条件,用归一化法测定其含量,并用气相色谱-质谱法对化学成分进行鉴定。共鉴定了38个成分,占挥发油总成分的86%以上。方法稳定可靠。重现性好,适用于中药挥发油的化学成分分析。  相似文献   

12.
普青  何宇雨  袁黎明 《色谱》2020,38(4):484-489
手性介孔材料在手性分离、不对称催化、手性传感等领域具有广泛的应用价值。手性有序无机介孔硅是一类介孔结构高度有序、不含有机成分的手性材料。该文采用D-苯丙氨酸为手性源合成手性有序无机介孔硅(COIMS),将其用聚硅氧烷(OV-1701)稀释后用作固定相制备毛细管气相色谱手性柱,并对该手性柱的分离性能进行了考察,8种手性化合物在该手性柱上得到了拆分。COIMS柱对直链烷烃、醇的分离也表现出良好的选择性。该柱还具有分析时间短、在较高温度下测定稳定等优点,其具有开发成高温手性固定相的潜力。  相似文献   

13.
Bruckner CA  Synovec RE 《Talanta》1996,43(6):901-907
A chemical sensor for gas phase measurements is reported which combines the principles of chemical separation and fiber optic detection. The analyzer incorporates an annular column Chromatographic sensor, constructed by inserting a polymer-clad optical fiber into a silica capillary. Light from a helium-neon laser is launched down the fiber, producing a steady intensity distribution within the fiber, but a low background of scattered light. When sample vapor is introduced to the sensor, and an analyte-rich volume interacts with the polymer cladding, Chromatographic retention is observed simultaneously with a change in the local refractive index of the cladding. An increase in cladding refractive index (RI) causes light to be coupled out of the fiber, with detection at a right-angle to the annular column length to provide optimum S/N ratio. This detection mechanism is called mode-filtered light detection. We report a gas Chromatographic separation on a 3.1 m annular column (320 microm i.d. silica tube, 228 microm o.d. fiber with a 12 microm fluorinated silicone clad) of methane, benzene, butanone and chlorobenzene in 6 min. The annular column length was reduced to 22 cm to function as a sensor, with selected organic vapors exhibiting unique retention times and detection selectivity. The detection selectivity is determined by the analyte RI and the partition coefficient into the cladding. The calculated limit of detection (LOD) for benzene vapor is 0.03% by volume in nitrogen, and several chlorinated species had LOD values less than 1%. For binary mixtures of organic vapors, the detected response appears to be the linear combination of the two organic standards, suggesting that the annular column may be useful as a general approach for designing chemical sensors that incorporate separation and optical detection principles simultaneously.  相似文献   

14.
中国苦水玫瑰油香气成分的研究   总被引:9,自引:0,他引:9  
周围  周小平  赵国宏  刘红卫  丁兰  陈立仁 《色谱》2002,20(6):560-564
 选择OV1701交联毛细管柱作为中国苦水玫瑰油的分离柱,并采用现代气相/质谱(GC/MS)、气相/红外光谱(GC/IR)技术手段,结合标准品对照,对玫瑰油中分离出的130余种化合物进行鉴别,初步鉴定出了101种化合物。研究表明,不同品种的玫瑰油形成各自不同的香味,这与栽培品种和土壤、温度、降雨量等综合栽培环境差异有关。中国苦水玫瑰油以其特有的浓郁玫瑰香气,应成为世界玫瑰油中一个重要品种。  相似文献   

15.
本文建立了气相色谱-微池电子捕获检测法(GC-μECD),同时测定生活饮用水中百菌清、七氯、滴滴涕、六六六、林丹、六氯丁二烯、溴氰菊酯、1,1-二-氯苯、1,2-二氯苯、三氯苯、六氯苯11种有机氯,马拉硫磷、对硫磷、甲基对硫磷、毒死蜱、乐果、敌敌畏6种有机磷,以及硝基苯、2,4,6-三硝基甲苯、1,3-二硝基苯、邻,间,对硝基氯苯、2,4-二硝基氯苯,2,4-二硝基甲苯6种硝基苯类有机物的分析方法.样品经萃取后,采用OV-1701色谱柱(30 m×0.25 mm×0.25μtm)程序升温进行分离,用微池电子捕获检测器(μECD)进行检测,通过保留时间定性,外标法定量.结果表明该方法分离效果好,灵敏度高,选择性强,简便、快速、准确,能够满足同时测定生活饮用水中上述23种有机化合物的需要.  相似文献   

16.
In this paper, the impact of airflow velocity and pressure in the two popular configuration gas chromatography (GC) column channels (the serpentine channel and the spiral channel) was simulated and evaluated using ANSYS dynamic analysis. The simulated result of airflow velocity and pressure distribution in the Gas chromatography (GC) channel shows that the impact in the spiral channel corner is smaller than that in the serpentine channel corner. So, the spiral channel columns were fabricated based on the MEMS technology and the stationary phase OV‐1 was coated using a dynamic procedure. The separation performance of the 3 m non‐polar GC column shows perfect separation efficiency for the non‐polar components, the microfabricated GC column yields 7100 theoretical plate, and the analysis time is less than 200 s.  相似文献   

17.
提出了18种食品基质中丙环唑残留量的气相色谱-质谱联用分析方法。样品中丙环唑利用乙腈或乙酸乙酯提取,C18和活性炭串联固相萃取柱净化,采用DB-1701弹性毛细管色谱柱进行分离。采用气相色谱-质谱电子轰击电离源和选择离子监测模式进行测定。在0.02~5.0mg.L-1范围内丙环唑标准溶液的峰面积与浓度呈线性关系(r=0.9995),在0.01,0.02,0.05mg.kg-13个添加水平下丙环唑的回收率在70%~115%之间,相对标准偏差(n=6)小于10.2%,检出限(3S/N)为0.004mg·kg-1。  相似文献   

18.
合成了一种手性离子液体L-丙氨酸叔丁酯双三氟甲烷磺酰亚胺(L-AlaC4NTf2), 将其作为新型气相色谱固定相, 并与OV-1701按不同比例混合, 考察了它们的色谱性能. 研究结果表明, 该离子液体作为手性固定相的热稳定性高于175 ℃; 平均McReynolds常数为665; 在容量因子为1.02时, 理论塔板数可达每米1095块; 其对烷烃、醇类、酮类、芳香族化合物、位置异构体以及一些手性化合物具有良好的分离效果.  相似文献   

19.
The high-temperature gas chromatographic (GC) separation of several semivolatile compounds is studied with a short metal capillary column packed with fibrous material, having a polydimethylsiloxane coating thereon. Taking advantage of the excellent heat-resistance of the fiber and also the combination of the surface-deactivated metal capillary, a temperature-programmed separation up to 450 degrees C is successfully demonstrated for the separation of polymer standard samples. The average molecular weight of the commercially-available polymer standard samples for size exclusion chromatography (SEC) is estimated by high-temperature GC analysis and compared with the nominal value determined by a conventional SEC method. Although a slight deviation for the number-average molecular weight is observed between the GC and SEC analysis, the data for the weight-average molecular weight shows a good agreement in these methods. The results also suggest the future possibility of the fiber-packed metal capillary as a miniaturized GC column with an increased sample loading capacity.  相似文献   

20.
S. Boneva 《Chromatographia》1991,31(3-4):171-172
Summary The GC separation of a mixture of three ethanolamines and four ethylene glycols without any preliminary derivatization, on a wide-bore capillary column coated with Carbowax 20M is described. These high-boiling and polar compounds elute giving simmetrical peaks and show good resolution. The analysis is completed in less than 14 minutes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号