首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple and sensitive method for determining anatoxin-a in aqueous samples was developed using solid-phase microextraction (SPME) and gas chromatography with mass spectrometry (GC-MS) detection. Three forms of polyaniline (PANI) films and a single form of polypyrrole (PPY) film were prepared and applied for SPME. The extraction properties of these films to anatoxin-a were examined and it was shown that leucoemeraldine form of PANI displayed a better selectivity to this compound. SPME conditions were optimized by selecting the appropriate extraction parameters, including type of coating (leucoemeraldine form of PANI at 32 microm thicknesses), salt concentration (10%, w/v), time of extraction (30 min) and stirring rate (1000 rpm). The calibration curve was linear in the range from 50 to 10,000 ng/ml, with the detection limit (S/N = 3) of 11.2 ng/ml. This method was successfully applied for the analysis of anatoxin-a in the cultured media of two species of cyanobacteria.  相似文献   

2.
A method for enantioselective determination of bromocyclen enantiomers in fish tissue has been developed. The enantiomers were resolved by capillary gas chromatography (GC) using a commercial chiral column (CP-Chirasil-Dex CB) and a temperature program from 50 degrees C (held for 1 min), raised to 140 degrees C at 40 degrees C min(-1) and then raised at 0.2 degrees C min(-1) to 155 degrees C. This enantioselective gas chromatographic separation was combined with a clean-up/enrichment procedure based on solid-phase microextraction (SPME). Under SPME optimized conditions, precision, linearity range and detection limits of the developed SPME-enantioselective GC procedure were evaluated and compared using two different detection systems: a classical electron-capture detection (ECD) and an element specific detection using inductively coupled plasma mass spectrometry (ICP-MS). The SPME-GC-ECD method exhibited an excellent sensitivity, with detection limits of 0.2 ng L(-1) for each enantiomer of bromocyclen. Although ICP-MS offered poorer detection limits (7 ng L(-1) as Br, equivalent to 36 ng L(-1) of each enantiomer) than conventional ECD detector, it proved to be clearly superior in terms of selectivity. The relative potential and performance of the two compared methods for real-life analysis has been illustrated by the determination of enantiomers of bromocyclen in spiked tissue extracts of trout.  相似文献   

3.
Determination of polybrominated diphenyl ethers (PBDEs) in environmental samples has raised great concerns due to the widespread use of PBDEs and their potential risk to humans. Solid-phase microextraction (SPME) is a fast, simple, cost-effective, and green sample preparation technique and is widely used for environmental analysis, but reports on the application of SPME for determination of PBDEs are very limited, and only a few publications dealing with commercial SPME fibers are available for extraction of PBDEs. Herein, we report a novel SPME method using multiwalled carbon nanotubes (MWCNTs) as the SPME fiber coating for gas chromatography with electron-capture detection (GC-ECD) of PBDEs in environmental samples. The MWCNTs coating gave much higher enhancement factors (616-1756) than poly (5% dibenzene-95% dimethylsiloxane) coating (139-384) and activated carbon coating (193-423). Thirty-minute extraction of 10 mL of sample solution using the MWCNTs coated fiber for GC-ECD determination yielded the limits of detection of 3.6-8.6 ng L(-1) and exhibited good linearity of the calibration functions (r(2)>0.995). The precision (RSD%, n=4) for peak area and retention time at the 500 ng L(-1) level was 6.9-8.8% and 0.6-0.9%, respectively. The developed method was successfully applied for the analysis of real samples including local river water, wastewater, and milk samples. The recovery of the PBDEs at 500 ng L(-1) spiked in these samples ranged from 90 to 119%. No PBDEs were detected in the river water and skimmed milk samples, whereas in the wastewater sample, 134-215 ng L(-1) of PBDEs were found. The PBDEs were detected in all whole fat milk samples, ranging from 13 to 484 ng L(-1). In a semiskimmed milk sample, only BDE-47 was found at 21 ng L(-1).  相似文献   

4.
A ceramic/carbon composite was developed and applied as a novel coating for solid-phase microextraction (SPME). The ceramic/carbon coating exhibited several good properties for SPME, such as high extraction quantities and enhanced thermal and organic solvent stability. Under scanning electron microscopy (SEM), the tightly attached coating layer on stainless steel wire revealed excellent mechanical characteristics. Single fiber and fiber-to-fiber reproducibility were less than 6.9 and 9.5%, respectively. The effects of extraction and desorption parameters such as extraction time, stirring rate, ionic strength, and desorption temperature and desorption time on the extraction/desorption efficiency were investigated and optimized. Coupled to gas chromatography with a flame thermionic detector, the optimized SPME method was applied to the analysis of organophosphorus pesticides (OPPs) in aqueous samples. The calibration curves were linear from 0.05 to 200 ng mL(-1) for fenchlorphos, pirimiphos-methyl, chlorpyrifos, ethion and from 0.2 to 200 ng mL(-1) for quinalphos, and the limits of detection were between 5.2 and 34.6 ng L(-1). The recovery of the OPPs spiked in real water samples at 5 ng mL(-1) ranged from 86.2 to 103.4% and the relative standard deviations were less than 8.5%.  相似文献   

5.
A novel dihydroxy-terminated benzo-15-crown-5 is synthesized and applied to prepare the solid-phase microextraction (SPME) fiber coating with sol-gel technology. Headspace SPME, as a simple, solvent-free method, is applied to the analysis of 16 organochlorine pesticides (OCPs) present at trace levels in a water sample. A homemade crown ether fiber coated with 80- micro m thickness was used for extraction. Analyses are performed using gas chromatography-electroncapture detection. The optimization of the extraction process is studied. Compared with commercially available SPME fibers, polydimethylsiloxane, the new phases show better selectivity and sensitivity toward OCPs. The linear concentrations range from 1 to 1000 ng/L, the detection limits are in the range of 0.01-0.5 ng/L, the recoveries are over 85%, and relative standard deviations are below 7.2% for these OCPs.  相似文献   

6.
田孟魁  冯喜兰 《中国化学》2008,26(7):1251-1256
建立了顶空固相微萃取联结气相色谱-电子捕获检测器(HS-SPME-GC-ECD)测定水中多溴联苯醚的方法。制作了多壁碳纳米管涂层固相微萃取探头。优化了萃取时间,萃取温度,搅拌速度,顶空体积,溶液的pH,离子强度及有机溶剂等影响萃取效率的各种因素。比较了室温和100 ℃顶空萃取和直接萃取的效率。结果表明,室温下直接萃取比顶空萃取的效率高2-4倍,而在100 ℃时顶空萃取比直接萃取的效率高1-8倍。除BDE-154外,无论直接萃取还是顶空萃取,100 ℃时的萃取效率均高于室温。方法的线性范围50-1600 ng/L,相关系数为0.995-0.998,5种多溴联苯醚的最低检出限(S/N=3)为1.14-16.25 ng/L,相对标准偏差(RSD%,n=5)小于10%。本方法用于真实水样的测定,回收率为74.2%-98.7%。  相似文献   

7.
A method for the determination of metolcarb and diethofencarb in apples and apple juice is developed using solid-phase microextraction (SPME) coupled with high-performance liquid chromatography (HPLC). The experimental conditions of SPME, such as the kind of extraction fiber, extraction time, stirring rate, pH of the extracting solution, and desorption conditions are optimized. The SPME is performed on a 60 microm polydimethylsiloxane/divinylbenzene fiber for 40 min at room temperature with the solution being stirred at 1100 rpm. The extracted pesticides on the SPME fiber are desorbed in the mobile phase into SPME-HPLC interface for HPLC analysis. Separations are carried out on a Baseline C18 column (4.6 i.d. x 250 mm, 5.0 microm) with acetonitrile-water (55/45, v/v) as the mobile phase at a flow rate of 1.0 mL/min, and photodiode-array detection at 210 nm. For apple samples, the method is linear for both metolcarb and diethofencarb in the range of 0.05-1.0 mg/kg (r > 0.99), with a detection limit (S/N = 3 ) of 15 and 5 microg/kg, respectively. For apple juice, the method is linear for both metholcarb and diethofencarb over the range of 0.05-1.0 mg/L (r > 0.99) with the detection limit (S/N = 3 ) of 15 and 3 microg/L, respectively. Excellent recovery and reproducibility values are achieved. The proposed method is shown to be simple, sensitive, and organic solvent-free, and is suitable for the determination of the two pesticides in apples and apple juice.  相似文献   

8.
张文敏  李青青  方敏  张兰 《色谱》2022,40(11):1022-1030
环境样品中多环芳烃(PAHs)含量较低且样品基质复杂,直接利用仪器进行含量测定比较困难,因此在仪器分析之前需要对环境样品进行必要的前处理。大多数前处理技术的萃取效率取决于萃取材料的特性。目前,金属有机骨架材料(MOFs)作为一种由金属离子与有机配体自组装而成的多孔材料,已经被用作固相微萃取(SPME)的涂层材料应用于PAHs的萃取,但是这些MOFs涂层材料由于目标物较难达到其深层的吸附位点,使得萃取过程往往需要较长的平衡时间;此外,大多数MOFs由单金属离子配位构成,能够提供的开放金属活性位点种类比较单一,较难获得最佳的萃取性能。这些问题在一定程度上限制了MOFs材料在SPME领域的应用。该研究制备了一种中空结构的双金属有机骨架材料(H-BiMOF),并将其作为SPME的涂层材料,用于萃取环境样品中痕量的PAHs。由于中空的结构和双金属的组成,H-BiMOF涂层材料拥有比表面积利用率高、传质距离短等优点,可以使萃取过程快速地达到平衡。同时,双金属的引入提供了种类丰富的金属活性位点,提高了对PAHs这类富电子云目标物的萃取效率。与气相色谱-串联质谱(GC-MS/MS)相结合,建立了一种用于环境水样中PAHs分析的新方法。所建立的分析方法具有检出限低(0.01~0.08 ng/L)、线性范围宽(0.03~500.0 ng/L)、重复性良好(相对标准偏差≤9.8%, n=5)等优点,并成功地用于实际湖水样品中7种PAHs的检测。实验结果表明,所建立的分析方法适用于环境样品中PAHs的分析与监测。  相似文献   

9.
A gas chromatography-high-resolution mass spectrometry (GC-HRMS) method using solid-phase microextraction (SPME) for the determination of 2,4,6-trichloroanisole (TCA) and 2,4,6-tribromoanisole (TBA) in wine at low ng L(-1) levels was developed. A robust SPME method was developed by optimizing several different parameters, including type of fiber, salt addition, sample volume, extraction and desorption time. The quantification limit for TCA and TBA in wine was lowered substantially using GC-HRMS in combination with the optimized SPME method and allowed the detection of low analyte concentrations (ng L(-1)) with good accuracy. Limits of quantification for red wine of 0.3 ng L(-1) for TCA and 0.2 ng L(-1) for TBA with gas chromatography-negative chemical ionization mass spectrometry and 0.03 ng L(-1) for TCA and TBA were achieved using GC-HRMS. The method was applied to 30 wines of which 4 wines were sensorically qualified as cork defected. TCA was found in three of these wines with concentrations in the range 2-25 ng L(-1). TBA was not detected in any of the samples.  相似文献   

10.
The feasibility of solid-phase microextraction (SPME) for the determination of several organophosphorus flame retardants and plastizicers in water samples by gas chromatography-nitrogen phosphorous detection (GC-NPD) is evaluated. These compounds have a wide range of polarities and volatilities and require a thorough optimisation of the different SPME parameters. Considering also possible contamination and carryover sources, the best compromise microextraction conditions were found to be direct extraction of 22 ml samples, containing 300 mg/ml of NaCl, with a PDMS-DVB coated fibre at room temperature. Although equilibrium was not achieved, an extraction time of 40 min allowed obtaining a good sensitivity (quantification limits between 0.010 and 0.025 ng/ml), comparable to that achieved by solid-phase extraction (SPE) of 1l samples, producing both similar values of precision and accuracy. Furthermore, the SPME method has shown to be free of matrix effects, avoiding the need of employing the standard addition procedure for quantification, and was suitable for the determination of eight of the nine considered compounds. Only tris-(2-ethylhexyl)-phosphate was neither determinable by SPME nor by SPE. Finally, the application of the developed methodology to the analysis of wastewater samples, showed that important concentrations of these compounds (up to 10 ng/ml) have been detected in treated sewage water, being discharged into the aquatic environment.  相似文献   

11.
A solid-phase microextraction (SPME) method has been developed to determine two methylated arsenic species in human urine samples by GC-MS. The direct extraction of the methyl arsenic compounds by SPME after thioglycol methylate derivatization was studied. Direct extraction with SPME was suitable for the determination of trace levels of dimethylarsinic acid (DMA) and monomethylarsonic acid (MMA) in urine samples. Four different commercial SPME fibers were tested for the extraction of methyl arsenic compounds, and the best results were obtained using the polydimethylsiloxane coating. The extraction and desorption time profiles of DMA and MMA were determined. The detection limits for DMA and MMA using the SPME-GC-MS method were 0.12 and 0.29 ng/ml, respectively. The method is linear in the 1 to 200 ng/ml range.  相似文献   

12.
The feasibility of single-walled carbon nanotubes (SWCNTs) as adsorbents for solid-phase microextraction was investigated by using organochlorine pesticides (OCPs) as model compounds. SWCNTs were attached onto a stainless steel wire through organic binder. Potential factors affecting the extraction efficiency were optimized, including extraction time, extraction temperature, desorption time, desorption temperature, and salinity. The developed method has a linear range of 2-800 ng/L for most analytes, with coefficients of correlation ranging from 0.9911 to 0.9996, LODs ranged from 0.19 to 3.77 ng/L (S/N = 3), and RSDs in the range of 3.5-13.9% (n = 5). Compared with the commercial PDMS fiber, the SWCNT fiber has better thermal stability (over 350 degrees C) and longer life span (over 150 times). The developed method was applied to determine trace OCPs in lake water and wastewater samples with external standard calibration. Results showed that OCP contamination was very low in these samples, and HCHs were detected in almost all water samples while DDT concentrations were almost under detection limits in these samples. Recoveries obtained at 20 ng/L spiking level were in the range of 88.4-111% for OCPs in lake water. For wastewater samples, however, the recoveries were satisfactory for HCHs (63.6-97.1%) but relatively low for DDTs (44.7-116%) due to the high content of organic matter in wastewater.  相似文献   

13.
In this work, we optimize a solid phase microextraction (SPME) method for the simultaneous collection of antibiotics (sulfonamides, macrolides, and trimethoprim) present in wastewaters. The performance of the SPME method is compared to a solid phase extraction (SPE) method. Analytes in both cases were quantified by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS-MS) with electrospray ionization. The advantages offered by SPME in this application are: decreased sample volume requirements, ease of sample processing and extraction, decreased cost, and most importantly, elimination of electrospray matrix effects. Despite having higher limits of quantification (16-1380 ng/L in influent and 35-260 ng/L in effluent), nearly all of the compounds found to be present in Edmonton Gold Bar wastewater by SPE were measurable by SPME (i.e., sulfamethoxazole, trimethoprim, erythromycin, and clarithromycin), with values similar to those obtained using the former method. Limits of quantification for the SPE method for the measured compounds were 4.7-15 ng/L and 0.86-6.1 ng/L for influent and effluent, respectively.  相似文献   

14.
A simple and rapid method for the determination of methyl tert-butyl ether (MTBE) in water by headspace-solid-phase microextraction (headspace-SPME) at sub-microg/L concentrations is described. On using a cooled SPME fiber coated with a 75-microm layer of poly(dimethylsiloxane)/carboxene and heating the sample to 35 degrees C, about 4 times more MTBE is extracted compared to SPME extraction with the fiber placed in the water sample. Stable analytical conditions with a detection limit of 10 ng/L are achieved. By use of a sample volume of 4 mL in a 10 mL vial, a sodium chloride content of 10% (w/w), and an extraction time of 30 min, the total time of an analytical cycle was optimized to 39 min. Precise linearity of R2>0.9991 and R2>0.9916 in the calibration range of 20-5000 ng/L and 20-100 ng/L, both in addition to blanks, respectively, and relative standard deviations of 10% (100 ng/L, long-term) and 11% (20 ng/L, short-term) are presented. The recovery is well within the accepted limits of 83-118% at a concentration of 100 ng/L and even close thereto at trace levels of 20 ng/L (96-125%). The data presented for a concentration of 100 ng/L are examined by statistical methods and show results for the T test at the 95% confidence level. Due to the large concentration range covered, the method is well suited for the monitoring of MTBE in the aquatic environment.  相似文献   

15.
To enable high sample throughput, an automated solid-phase microextraction (SPME) method coupled with GC-MS for the trace analysis of technical nonylphenol, bisphenol A and 17alpha-ethinylestradiol was developed. The extraction performance of different SPME fibre coatings was examined, with polyacrylate proving most suitable. Although study of the extraction time showed that the analytes have not reached equilibrium after 3 h, as a compromise an extraction time of 1 h was applied in all the experiments with detection limits between 0.04 and 1 microg l(-1) for wastewater effluent. The mean reproducibility of the technique is 8% RSD. Carry-over effects are negligible. The linearity of calibration curves ranges over three orders of magnitude. The method was tested for determining the analytes in influents and effluents of constructed wetland plants and in model wastewater used in laboratory experiments.  相似文献   

16.
Yohimbine is a novel compound for the treatment of erectile dysfunction derived from natural products, and pharmacokinetic study is important for its further development as a new medicine. In this work, we developed a novel PEEK tube‐based solid‐phase microextraction (SPME)–HPLC method for analysis of yohimbine in plasma and further for pharmacokinetic study. Poly (AA‐EGDMA) was synthesized inside a PEEK tube as the sorbent for microextraction of yohimbine, and parameters that could influence extraction efficiency were systematically investigated. Under optimum conditions, the PEEK tube‐based SPME method exhibits excellent enrichment efficiency towards yohimbine. By using berberine as internal standard, an online SPME‐HPLC method was developed for analysis of yohimbine in human plasma sample. The method has wide linear range (2–1000 ng/mL) with an R 2 of 0.9962; the limit of detection was determined and was as low as 0.1 ng/mL using UV detection. Finally, a pharmacokinetic study of yohimbine was carried out by the online SPME‐HPLC method and the results have been compared with those of reported methods.  相似文献   

17.
Wu J  Lord H  Pawliszyn J 《Talanta》2001,54(4):655-672
A simple and sensitive method for the determination of amphetamine, methamphetamine and their methylenedioxy derivatives in urine and hair samples was developed by coupling automated in-tube solid phase microextraction (SPME) to high performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-ES-MS). To achieve optimum performance, the conditions for both the in-tube SPME and the ES-MS detection were investigated. ES-MS detection conditions were studied by flow injection analysis (FIA) with direct liquid injection. In-tube SPME conditions were optimized by selecting the appropriate extraction parameters, including capillary stationary phases and sample pH. For the compounds studied, a custom-made polypyrrole (PPY) coated capillary showed superior extraction efficiency as compared to commercial capillaries. Therefore, the PPY coated capillary was selected for in-tube SPME in this study. The calibration curves of stimulants were linear in the range from 0.1 to 100 ng ml(-1) with detection limits (S/N=3) of 8-56 ng l(-1). This method was successfully applied to the analysis of the stimulants in spiked human urine and hair samples.  相似文献   

18.
Hu X  Pan J  Hu Y  Huo Y  Li G 《Journal of chromatography. A》2008,1188(2):97-107
Molecularly imprinted polymer (MIP) is widely used in many fields because of its characteristics of high selectivity, chemical stability and easy preparation. To enhance the selectivity and applicability of solid-phase microextraction (SPME), a novel MIP-coated SPME fiber was firstly prepared by multiple co-polymerization method with tetracycline as template. It could be coupled directly to high-performance liquid chromatography (HPLC) and used for trace analysis of tetracyclines (TCs) in complicated samples. The characteristics and application of the fibers were investigated. The electron microscope provided a crosslinked and porous surface, and the average thickness of the MIP coating was 19.5 microm. Compared with the non-imprinted polymer (NIP) coated fibers, the special selectivity to tetracycline and structure-similar oxytetracycline, doxycycline, chlortetracycline were discovered with the MIP-coated fibers. The adsorption and desorption of TCs with the MIP-coated fiber could be achieved quickly. A method for the fluorimetric determination of four TCs by the MIP-coated SPME coupled with HPLC was developed. The optimized extraction conditions such as extraction solvent, desorption solvent, and stirring speed were studied. Linear ranges for the four TCs were 5.00-200 microg/L and detection limits were within the range of 1.0-2.3 microg/L. The method was applied to simultaneous multi-residue analysis of four TCs in the spiked chicken feed, chicken muscle, and milk samples with the satisfactory recoveries.  相似文献   

19.
We developed a sensitive and useful method for the determination of five fluoroquinolones (FQs), enoxacin, ofloxacin, ciprofloxacin, norfloxacin, and lomefloxacin in environmental waters, using a fully automated method consisting of in-tube solid-phase microextraction (SPME) coupled with liquid chromatography-tandem mass spectrometry (LC/MS/MS). These compounds were analysed within 7 min by high-performance liquid chromatography (HPLC) using a CAPCELL PAK C8 column and aqueous ammonium formate (pH 3.0, 5 mM)/acetonitrile (85/15, v/v) at a flow rate of 0.2 mL/min. Electrospray ionization conditions in the positive ion mode were optimized for MS/MS detection. In order to optimize the extraction of FQs, several in-tube SPME parameters were examined. The optimum in-tube SPME conditions were 20 draw/eject cycles of 40 μL of sample at a flow-rate of 150 μL/min, using a Carboxen 1010 PLOT capillary column as an extraction device. The extracted compounds were easily desorbed from the capillary by passage of the mobile phase. Using the in-tube SPME LC/MS/MS method, good linearity of the calibration curve (r ≥ 0.997) was obtained in the concentration range from 0.1 to 10 ng/mL for all compounds examined. The limits of detection (S/N = 3) of the five FQs ranged from 7 to 29 pg/mL. The in-tube SPME method showed 60-94-fold higher sensitivity than the direct injection method (5 μL injection). This method was applied successfully to the analysis of environmental water samples without any other pretreatment and interference peaks. Several surface waters and wastewaters were collected from the area around Asahi River, and ofloxacin was detected in wastewater samples of a sewage treatment plant and other two hospitals at 17.5-186.2 pg/mL. The recoveries of FQs spiked into river water were above 81% for a 0.1 or 0.2 ng/mL spiking concentration, and the relative standard deviations were below 1.9-8.6%.  相似文献   

20.
固相微萃取-气相色谱法测定红葡萄酒中残留的有机磷农药   总被引:22,自引:0,他引:22  
胡媛  刘文民  周艳明  关亚风 《色谱》2006,24(3):290-293
采用溶胶-凝胶包埋技术制备了耐高温固相微萃取头(SPME),用该萃取头与气相色谱-热离子化检测器联用对红葡萄酒中的12种有机磷农药残留进行了测定。实验中对搅拌速度、萃取时间、盐浓度等条件进行了优化。结果表明,在样品用量25 mL,搅拌速度1250 r/min,盐浓度 150 g/L,萃取时间30 min的条件下,绝大多数组分峰面积的相对标准偏差(RSD)在5%以下,各种有机磷农药的检测限为5 ng/L到0.38 μg/L。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏