首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
介绍了在合肥光源重大维修改造工程期间,开发的一套基于扫频激励法的工作点测量系统。测量系统硬件包括基于条带BPM的信号拾取电极、前端信号调理模块、一台带跟踪输出的信号分析仪N9000AEP、功率放大器以及用于激励束流的条带激励器。系统控制软件采用EPICS开发,基于EPICS Stream Device设计的输入输出控制器(soft IOC)运行在服务器虚拟机中,通过VXI11协议进行通信实现对信号分析仪的控制和数据获取;用户操作界面采用EPICS平台下的EDM开发,通过Channel Access与IOC通信。在HLS-II储存环上对工作点测量系统进行了在线的调试。调试结果说明,在扫频范围为2.1 MHz到4.1 MHz时,工作点测量系统的统计分辨率在水平方向上好于0.000 3,在垂直方向上好于0.000 2。  相似文献   

2.
In order to further obtain the information of three-body force(TBF) from 200–400 Me V/u12C+12C elastic scattering, we plan to perform this experiment on a SHARAQ spectrometer. Based on the experimental condition of the Radioactive Ion Beam Factory(RIBF)-SHARAQ facility, a simulation is given to find a compromise between the better energy and angular resolutions, and higher yield by optimizing the target thickness, beam transport mode, beam intensity and angular step. From the simulation, we found that the beam quality mainly limits the improvements of energy and angular resolutions. A beam tracking system as well as a lateral and angular dispersionmatching technique are adopted to reduce the influence of beam quality. According to the two angular settings of SHARAQ as well as the expected cross sections on the basis of the theoretical model, the energy and angular resolutions, and statistical accuracy are estimated.  相似文献   

3.
研究了基于硅光电倍增管(SiPM)双端读出的面积为10 cm ×10 cm的薄塑料闪烁体探测器的时间性能。239Pu放射源测试结果显示:(1)在多支SiPM串连读出方式下,随着SiPM数量的增加,探测器时间分辨逐渐变好;(2)在固定12支SiPM数量不变的情况下,并联支路越多,探测器时间分辨越差;(3)采用快时间塑料闪烁体并增加其厚度,可有效提高探测器时间分辨;(4)采用比束斑尺寸更大的塑料闪烁体,可有效提高探测器时间分辨的位置均匀性;(5)对于1 mm厚的EJ232塑料闪烁体探测器,在单端12支SiPM串行连接的情况下,可获得好于131 ps的时间分辨。这一研究对RIBLL2起始时间探测器的升级改造具有重要的指导意义。  相似文献   

4.
在线测量表面粗糙度的共光路激光外差干涉仪   总被引:8,自引:0,他引:8  
一种新型的、用于在线测量表面粗糙度的激光外差干涉仪已研制完成。该仪器体积小(25cm×20cm×10cm)、抗外界环境干扰能力强。仪器以稳频半导体激光器作为光源。共光路设计,使测量光和参考光沿同一路径入射到被测表面上。计大数和测小数周期相结合的外差信号处理方法,实现了大的动态测量范围和很高的测量分辩率。同时还采用了全反射临界角法进行自动聚焦。该仪器的纵向和横向分辨率分别为0.39nm和0.73μm;自动聚焦范围为±0.5mm,在焦点±25μm范围内,聚焦精度为1μm;80分钟内整机稳定性:3σ=1.95nm。  相似文献   

5.
多条形电极束流能散度探测器的张角优化   总被引:3,自引:3,他引:0       下载免费PDF全文
 采用Surperfish对北京正负电子对撞机的多条形电极束流能散度探测器进行了电磁场模拟计算。在带模拟束流的情况下,计算分析了探测器对束流位置和能散度的分辨能力与电极张角之间的关系,首次计算了条形电极间的电容耦合综合强度。电极张角优化结果表明:在不考虑噪声水平的情况下,电极张角为20°时,探测器的灵敏度和分辨率达到最优。而当噪声影响很大时,可以适当增加电极张角,同时考虑减小噪声的措施。  相似文献   

6.
Weiqian Zhao  Qi Li  Lirong Qiu  Jiubin Tan  Qi Wang 《Optik》2005,116(12):557-562
A shaped annular beam superresolution approach is proposed to improve a lateral resolution of a small probe laser confocal measurement system (LCMS). The approach proposed enables lateral superresolution measurement of LCMS to be achieved by using a binary optical diffractive element to shape a He–Ne Gaussian laser beam into an annular beam with an inner diameter of 0.87 mm and an outer diameter of 1.8 mm required for superresolution measurement, and shift the beam spatial frequency from low to high. And a binary optical element (BOE) with 16 phase levels is designed and fabricated to shape a Gaussian laser beam into an annular beam. Preliminary experimental results indicate that an intensity distribution of a shaped annular beam is in agreement with simulation results, the diffractive efficiency is 87.2%; LCMS lateral and axial resolutions of 0.2 μm and 3 nm are achieved, respectively, and its measurement range is expanded nearly to double, when BOE is used in LCMS and , NA=0.85.  相似文献   

7.
Jianjin Zhou 《中国物理 B》2022,31(5):50702-050702
In recent years, gas electron multiplier (GEM) neutron detectors have been developing towards high spatial resolution and high dynamic counting range. We propose a novel concept of an Al stopping layer to enable the detector to achieve sub-millimeter (sub-mm) spatial resolution. The neutron conversion layer is coated with the Al stopping layer to limit the emission angle of ions into the drift region. The short track projection of ions is obtained on the signal readout board, and the detector would get good spatial resolution. The spatial resolutions of the GEM neutron detector with the Al stopping layer are simulated and optimized based on Geant4GarfieldInterface. The spatial resolution of the detector is 0.76 mm and the thermal neutron detection efficiency is about 0.01% when the Al stopping layer is 3.0 μ m thick, the drift region is 2 mm thick, the strip pitch is 600 μ m, and the digital readout is employed. Thus, the GEM neutron detector with a simple detector structure and a fast readout mode is developed to obtain a high spatial resolution and high dynamic counting range. It could be used for the direct measurement of a high-flux neutron beam, such as Bragg transmission imaging, very small-angle scattering neutron detection and neutron beam diagnostic.  相似文献   

8.
The Gorizont time-of-flight neutron reflectometer—small-angle spectrometer has been designed, manufactured, and assembled to operate with the IN-0 6 pulsed neutron source. The instrument has a vertical neutron scattering plane enabling research on liquid surfaces and interfaces. Model calculations of neutron spectra, beam profiles, and spectrometer resolutions have been performed via the Monte Carlo method. The spectrometer operates at wavelengths from 1.5 to 9 Å and ensures measurements in the momentum-transfer range of 0.003—1.5 Å-1.  相似文献   

9.
DISCO, a novel low‐energy beamline covering the spectrum range from the VUV to the visible, has received its first photons at the French synchrotron SOLEIL. In this article the DISCO design and concept of three experimental stations serving research communities in biology and chemistry are described. Emphasis has been put on high flux generation and preservation of polarization at variable energy resolutions. The three experiments include a completely new approach for microscopy and atmospheric pressure experiments as well as a `classical' synchrotron radiation circular dichroism station. Preliminary tests of the optical design and technical concept have been made. Theoretical predictions of the beam have been compared with the first images produced by the first photons originating from the large‐aperture bending‐magnet source. Results are also reported concerning the cold finger used to absorb hard X‐ray radiation in the central part of the synchrotron beam and to avoid heavy thermal load on the following optics. Wavelength selection using monochromators with different gratings for each experimental set‐up as well as beam propagation and conditioning throughout the optical system are detailed. First photons comply very well with the theoretical calculations.  相似文献   

10.
A directed photoelectron beam is obtained when photoelectrons from a sharp metal tip irradiated by femtosecond laser pulses are passed through a quartz nanocapillary. Such a nanolocalized photoelectron train makes it possible to conduct experiments with simultaneous femtosecond time and nanometer spatial resolutions.  相似文献   

11.
描述了基于CCD摄像的同步辐射光束线光斑位置监测系统.在光束线运行中实时监测光斑与入射狭缝的相对位置.已在国家同步辐射实验室多条光束线安装.对光斑位置及其角度监测的准确度分别达到10.53 μm、2.3 μrad,具有较高的灵敏度.在线监测到同步辐射光斑的垂直抖动0.37 mm、扭转角度83 μrad.说明此时电子束流不稳定,偏离了预计的轨道.同时,为同步辐射光束线的调试和电子束流的诊断提供了可靠的依据.  相似文献   

12.
宽光谱Czerny-Turner光谱仪中的彗差与分辨率   总被引:1,自引:0,他引:1  
小型光谱仪较多地采用Czerny-Turner(切尼—特纳)光路结构,其设计应遵循Shafer消彗差原理消除中心波长处的初级彗差并尽量平直整个谱面以提高分辨率。但常规设计并未考虑非中心波长处彗差和分辨率的变化情况。在对两种典型切尼—特纳光路结构进行初级彗差分析的基础上,指出交叉型光路结构宽光谱范围内的分辨率呈“V”形,而M型光路结构分辨率在全光谱范围内变化较小,近似呈“一”形,即后者宽光谱范围内的分辨率一致性远好于前者。针对于此,该文设计了光谱范围为400~600 nm的2种光路,并对其进行了理论计算和对比实验,实验结果表明,两者边缘波长处分辨率分别比中心波长处分辨率低3.7倍和1.2倍,与理论计算结果基本一致。  相似文献   

13.
This paper describes the mapping of the spatiotemporal principal stress distribution evolved with time in an epoxy photoelastic sample. In the optical heterodyne polarimeter exploited, the signal beam of light transmitted by the sample under continuously loaded condition is photomixed with the local oscillator beam of light made up of orthogonal linearly polarized two-frequency components. Every pixel of a MOS video camera used generates a beat photocurrent that possesses the two orthogonal field components of the elliptically polarized signal beam. The spatiotemporal principal stress distributions can be uniquely determined simultaneously and independently from these two orthogonal field components, and are successfully mapped in a time-sequential form. The spatial and temporal resolutions in the maps are 0.18 mm and 2.9 ms, respectively.  相似文献   

14.
The significant modifications to our recently constructed electron momentum spectrometer have been implemented. Compared with our previous report, the energy and the angle resolutions are significantly improved and reach △E = 0.45 eV, △θ = ±0.53° and △φ = ±0.84°, respectively. Moreover, the details of data reduction and the relation between azimuthal angle range and the sensitivity are discussed.  相似文献   

15.
An electron beam is obtained using laser wakefield electron accelerator, and converted into a γ-ray source after undergoing bremsstrahlung radiation in a dense material. A quasi-monoenergetic structure is observed when the length of the plasma channel was modified. The structure has a 58-MeV peak energy, 15mrad (full-width at half-maximum) divergence angle, and 340-pC charge. The γ-ray source generated by this high-quality electron beam is brighter and has higher spatial and temporal resolutions than other conventional sources. A γ-ray radiography demonstrational experiment is performed. Pictures of a ball with different layers made of different materials are taken. The results show a clear structure and density resolution.  相似文献   

16.
High-resolution ghost image and ghost diffraction experiments are performed by using a single classical source of pseudothermal speckle light divided by a beam splitter. Passing from the image to the diffraction result solely relies on changing the optical setup in the reference arm, while leaving the object arm untouched. The product of spatial resolutions of the ghost image and ghost diffraction experiments is shown to overcome a limit which seemed to be achievable only with entangled photons.  相似文献   

17.
Daniel Aronov  Gil Rosenman   《Surface science》2009,603(16):2430-2433
We describe here an alternative approach to direct low-energy electron beam nanolithography process with no conventional deposition of any resist or self-assembled monolayer. The method is based on direct formation of ultrathin dielectric layer on electron irradiated surface, without generation of structural defects. High-quality electron-induced patterns with lateral resolutions of about 10 nm are demonstrated on SiO2 surface.  相似文献   

18.
Coherent x-ray diffraction imaging is an x-ray microscopy technique with the potential of reaching spatial resolutions well beyond the diffraction limits of x-ray microscopes based on optics. However, the available coherent dose at modern x-ray sources is limited, setting practical bounds on the spatial resolution of the technique. By focusing the available coherent flux onto the sample, the spatial resolution can be improved for radiation-hard specimens. A small gold particle (size <100 nm) was illuminated with a hard x-ray nanobeam (E=15.25 keV, beam dimensions approximately 100 x 100 nm2) and is reconstructed from its coherent diffraction pattern. A resolution of about 5 nm is achieved in 600 s exposure time.  相似文献   

19.
基于光纤Bragg光栅反射波带宽展宽的压力传感研究   总被引:13,自引:9,他引:4  
报道了一种新颖的光纤Bragg光栅压力传感装置,提出并实现了利用光纤Bragg光栅反射波带宽展宽实现压力传感的新方法.利用压力作用下双孔悬臂梁非均匀应变带动光栅使Bragg反射波漂移的同时带宽展宽,实现压力传感.在0~23.5 N的测量范围内,基于光谱分析仪0.05 nm的光谱分辨率,压力分辨率为0.54 N,带宽最大展宽量2.14 nm,压力响应曲线具有良好的线性.多次测量表明:展宽波型稳定,重复性好.  相似文献   

20.
A general calculation of the correction to the measured cross section in fixed-target experiments, due to the angular resolution of the incident beam, is carried out. A first-order expression in the incident solid angle ΔΩ is explicity given, and shows that, in the TeV region, angular resolutions as accurate as 10?1 mrad are required for measurements within the cross-section forward peak.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号