首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 218 毫秒
1.
张海燕  于建波 《中国物理 B》2011,20(9):94301-094301
Excitation and propagation of Lamb waves by using rectangular and circular piezoelectric transducers surface-bonded to an isotropic plate are investigated in this work. Analytical stain wave solutions are derived for the two transducer shapes, giving the responses of these transducers in Lamb wave fields. The analytical study is supported by a numerical simulation using the finite element method. Symmetric and antisymmetric components in the wave propagation responses are inspected in detail with respect to test parameters such as the transducer geometry, the length and the excitation frequency. By placing only one piezoelectric transducer on the top or the bottom surface of the plate and weakening the strength of one mode while enhancing the strength of the other modes to find the centre frequency, with which the peak wave amplitude ratio between the S0 and A0 modes is maximum, a single mode excitation from the multiple modes of the Lamb waves can be achieved approximately. Experimental data are presented to show the validity of the analyses. The results are used to optimize the Lamb wave detection system.  相似文献   

2.
Lam KH  Chen Y  Cheung KF  Dai JY 《Ultrasonics》2012,52(1):20-24
A ∼5 MHz focusing PMN-PT single crystal ultrasound transducer has been fabricated utilizing a mechanical dimpling technique, where the dimpled crystal wafer was used as an active element of the focusing transducer. For the dimpled focusing transducer, the effective electromechanical coupling coefficient was enhanced significantly from 0.42 to 0.56. The dimpled transducer also yields a −6 dB bandwidth of 63.5% which is almost double the bandwidth of the plane transducer. An insertion loss of the dimpled transducer (−18.1 dB) is much lower than that of the plane transducer. Finite element simulation also reveals specific focused beam from concave crystal surface. These promising results show that the dimpling technique can be used to develop high-resolution focusing single crystal transducers.  相似文献   

3.
Acoustic transducers made from piezoelectric ceramic cylinders usually exploit the breathing or omnidirectional (omni) mode of vibration. However, with suitable voltage distribution, higher order extensional modes of the cylinder can be excited which produce directional radiation patterns. These modal radiation patterns can then be combined to synthesize desired beam patterns which may be steered by incrementing the excitation. This paper describes a model for the combined acoustic response of the extensional modes of vibration of a piezoelectric ceramic cylinder, a method of synthesizing a desired radiation pattern, and an experimental implementation of a directional transducer that uses these techniques. This tri-modal transducer is broadband and directional with a frequency independent beam pattern yet simple, small, and lightweight.  相似文献   

4.
Acoustic particle manipulation has many potential uses in flow cytometry and microfluidic array applications. Currently, most ultrasonic particle positioning devices utilize a quasi-one-dimensional geometry to set up the positioning field. A transducer fit with a quarter-wave matching layer, locally drives a cavity of width one-half wavelength. Particles within the cavity experience a time-averaged drift force that transports them to a nodal position. Present research investigates an acoustic particle-positioning device where the acoustic excitation is generated by the entire structure, as opposed to a localized transducer. The lowest-order structural modes of a long cylindrical glass tube driven by a piezoceramic with a line contact are tuned, via material properties and aspect ratio, to match resonant modes of the fluid-filled cavity. The cylindrical geometry eliminates the need for accurate alignment of a transducer/reflector system, in contrast to the case of planar or confocal fields. Experiments show that the lower energy density in the cavity, brought about through excitation of the whole cylindrical tube, results in reduced cavitation, convection, and thermal gradients. The effects of excitation and material parameters on concentration quality are theoretically evaluated, using two-dimensional elastodynamic equations describing the fluid-filled cylindrical shell with a line excitation.  相似文献   

5.
To understand the effect of the sound field on sonochemical luminescence, the exact sound pressure must be determined in each field. In this study it was determined by the Shlieren method, which measures the sound pressure without mixing the sound fields. We compared the efficiency of the sonochemical luminescence in three different ways: changing the diameter of the transducer, combining two transducers to obtain crossed propagating directions and surrounding the sound field by a glass cylinder. In the last case cylinders with various sizes were studied. We found that (i) at the same sound pressure, the larger transducer induces stronger luminescence per unit volume, (ii) driving two transducers produces stronger luminescence than the sum of each transducer and (iii) a glass cylinder surrounding the sound field induces stronger luminescence.  相似文献   

6.
First-order perturbation theory is employed to examine sound propagation in flowing media confined by a cylindrical waveguide. The use of perturbation theory allows examination of mode phase-speed changes due to any radially dependent flow w(r) as long as the flow magnitude is sufficiently small. The condition to be fulfilled is satisfied in the flow range: 0-0.3 m/s for the specific values of cylinder radius, ultrasound frequency, and sound speed analyzed in the present work [in the general case, however, the condition in Eq. (1) of the present work must be fulfilled]. This freedom of choice, i.e., the possibility to handle any radial flow profile, is used to analyze two flow profile cases: (1) where w(r) is a linear combination of a laminar flow profile and a flat profile corresponding to turbulent flow, and (2) where w(r) is a linear combination of a laminar flow profile and a more realistic logarithmic-dependent turbulent flow profile. In both cases, it is shown that large errors may result in ultrasound flow measurements if several modes are excited by the transmitting transducer, and that a logarithmic flow profile in the turbulent regime leads to somewhat larger measurement errors at high flow values as compared to assuming a simple flat profile in the turbulent regime.  相似文献   

7.
Behar V  Adam D  Friedman Z 《Ultrasonics》2003,41(5):385-395
Conventional ultrasound color flow mapping systems estimate and visualize only the axial velocity component. To obtain the transverse velocity component a modification of a multiple-beam method is proposed. The new two-dimensional color flow mapping system has a small size and consists of three transducers. The central transducer is an appodized and focused phased array. The other transducers are unfocused probes. Three transducers act as receivers and the central transducer operates as a transmitter. All receivers acquire rf scan lines that are then processed to estimate three axial velocity components using an autocorrelation method. These estimates are then combined to estimate the transverse velocity component, taking into account the geometric relationships among three transducers. Two algorithms for transverse velocity estimation are proposed. The first uses the Doppler angle estimate for calculation of the transverse velocity component. The other algorithm calculates the transverse velocity component directly from the axial components. The accuracy of the flow velocity estimators is estimated by simulations. Analysis of accuracy allows choosing the more effective algorithm for two-dimensional velocity estimation, which is insensitive to variations of the Doppler angle.  相似文献   

8.
We are investigating means of handling microparticles in microfluidic systems, in particular localized acoustic trapping of microparticles in a flow-through device. Standing ultrasonic waves were generated across a microfluidic channel by ultrasonic microtransducers integrated in one of the channel walls. Particles in a fluid passing a transducer were drawn to pressure minima in the acoustic field, thereby being trapped and confined at the lateral position of the transducer. The spatial distribution of trapped particles was evaluated and compared with calculated acoustic intensity distributions. The particle trapping was found to be strongly affected by near field pressure variations due to diffraction effects associated with the finite sized transducer element. Since laterally confining radiation forces are proportional to gradients in the acoustic energy density, these near field pressure variations may be used to get strong trapping forces, thus increasing the lateral trapping efficiency of the device. In the experiments, particles were successfully trapped in linear fluid flow rates up to 1mm/s. It is anticipated that acoustic trapping using integrated transducers can be exploited in miniaturised total chemical analysis systems (microTAS), where e.g. microbeads with immobilised antibodies can be trapped in arrays and subjected to minute amounts of sample followed by a reaction, detected using fluorescence.  相似文献   

9.
This paper outlines a method that has been implemented to predict and measure the acoustic radiation generated by ultrasonic transducers operating into air in continuous wave mode. Commencing with both arbitrary surface displacement data and radiating aperture, the transmitted pressure beam profile is obtained and includes simulation of propagation channel attenuation and where necessary, the directional response of any ultrasonic receiver. The surface displacement data may be derived directly, from laser measurement of the vibrating surface, or indirectly, from finite element modeling of the transducer configuration. To validate the approach and to provide experimental measurement of transducer beam profiles, a vibration-free, draft-proof scanning system that has been installed within an environmentally controlled laboratory is described. A comparison of experimental and simulated results for piezoelectric composite, piezoelectric polymer, and electrostatic transducers is then presented to demonstrate some quite different airborne ultrasonic beam-profile characteristics. Good agreement between theory and experiment is obtained. The results are compared with those expected from a classical aperture diffraction approach and the reasons for any significant differences are explained.  相似文献   

10.
A microcomputer-based ultrasonic gas flowmeter with transit-time method is presented. Modules of the flowmeter are designed systematically, including the acoustic path arrangement, ultrasound emission and reception module, transit-time measurement module, the software and so on. Four 200 kHz transducers forming two acoustic paths are used to send and receive ultrasound simultaneously. The synchronization of the transducers can eliminate the influence caused by the inherent switch time in simple chord flowmeter. The distribution of the acoustic paths on the mechanical apparatus follows the Tailored integration, which could reduce the inherent error by 2–3% compared with the Gaussian integration commonly used in the ultrasonic flowmeter now. This work also develops timing modules to determine the flight time of the acoustic signal. The timing mechanism is different from the traditional method. The timing circuit here adopts high capability chip TDC-GP2, with the typical resolution of 50 ps. The software of Labview is used to receive data from the circuit and calculate the gas flow value. Finally, the two paths flowmeter has been calibrated and validated on the test facilities for air flow in Shaanxi Institute of Measurement & Testing.  相似文献   

11.
J.C. Adamowski 《Ultrasonics》2010,50(2):110-115
This work describes the use of a large-aperture PVDF receiver in the measurement of liquid density and composite material elastic constants. The density measurement of several liquids is obtained with accuracy of 0.2% using a conventional NDE emitter transducer and a 70-mm-diameter, 52-μm P(VDF-TrFE) membrane with gold electrodes. The determination of the elastic constants is based on the phase velocity measurement. Diffraction can lead to errors around 1% in velocity measurement when using alternatively the conventional pair of ultrasonic transducers (1-MHz frequency and 19-mm-diameter) operating in through-transmission mode, separated by a distance of 100 mm. This effect is negligible when using a pair of 10-MHz, 19-mm-diameter transducers. Nevertheless, the dispersion at 10 MHz can result in errors of about 0.5%, when measuring the velocity in composite materials. The use of an 80-mm diameter, 52-μm-thick PVDF membrane receiver practically eliminates the diffraction effects in phase velocity measurement. The elastic constants of a carbon fiber reinforced polymer were determined and compared with the values obtained by a tensile test.  相似文献   

12.
In Lamb waves inspection, an air-coupled transmitter transducer is oriented at a specific angle such that it generates a pure Lamb mode which propagates along the structure and interacts with any existing defects. For this inspection system, amplitude losses appears when small inclinations of the tested structure occurs. An important factor which affects directly these losses has been observed, it consists of the Lamb waves beam (LWB) deviation due to this bad alignment. In this work, a simple expression of LWB deviation has been deduced. This expression includes the test structure angle, phase velocity of generated Lamb mode, and the phase velocity of waves propagating in the coupled medium. A(0) Lamb mode is generated and detected in 1 mm thick aluminium plate sample using 1 MHz PZ27 piezoelectric transducers of 20 mm of diameter. Experimental LWB deviation angles are measured for different inclination angles of the test sample. A comparative study is released with theoretical results. For 1 degree of misalignment in the aluminium plate inclination, and transducers separation distance of 35 mm, LWB deviation angle is around 7 degrees and the amplitude is reduced by around 11%. Then, for a large separation distance, we must move the receiver transducer to detect the deviated LWB. It is shown that, for both theoretical and experimental studies, the LWB deviation and its measured amplitude are very sensitive to the alignment of the tested structure with respect to the transmitter-receiver transducers plane. In metal plates it is most satisfactory to use A(0) mode compared with S(0) mode since it is easy to excite and has a large amplitude and small deviation beam angles.  相似文献   

13.
光弹法测量超声换能器声场   总被引:6,自引:3,他引:3       下载免费PDF全文
超声换能器声场的测试对于超声检测具有基础性作用,而传统的超声换能器声场测试方法具有一些局限性。本文介绍了搭建的动态激光光弹实验平台,并利用动态光弹法测量了纵波换能器和横波换能器辐射声场的特征,由瞬态声场图像获得了传声介质的声波速度及超声换能器的中心频率;由稳态声场图像获得了声场的近场长度、指向性和扩散角等参数;分析了光弹实验系统和测量方法可能引起测量误差。本文结果表明动态光弹法是一种有效的定量测量超声换能器声场的方法。  相似文献   

14.
模式转换型超声塑焊振动系统的设计   总被引:4,自引:0,他引:4  
许龙  林书玉 《声学学报》2010,35(6):688-693
基于弯曲振动理论和耦合振动理论,设计了一种新型大尺寸筒形超声塑焊振动系统。该振动系统由纵向振动换能器及变幅杆、弯曲振动金属圆盘和耦合振动圆筒四部分组成。换能器和变幅杆的纵向振动驱动圆盘的二次弯曲模式振动,圆盘的二次弯曲模式振动激励圆筒的纵向模式振动,实现了工具头在较高频率下谐振。实验结果表明,振动系统的测试频率与计算频率比较符合,在大信号下测试的纵-弯-纵振动模式转换效果很好。研究结果为高频大尺寸超声焊接系统的设计提供了思路。   相似文献   

15.
Current medical diagnostic echo systems are mostly using harmonic imaging. This means that a fundamental frequency (e.g., 2 MHz) is transmitted and the reflected and scattered higher harmonics (e.g., 4 and 6 MHz), produced by nonlinear propagation, are recorded. The signal level of these harmonics is usually low and a well-defined transfer function of the receiving transducer is required. Studying the acoustic response of a single contrast bubble, which has an amplitude in the order of a few Pascal, is another area where an optimal receive transfer function is important.

We have developed three methods to determine the absolute transfer function of a transducer. The first is based on a well-defined wave generated by a calibrated source in the far field. The receiving transducer receives the calibrated wave and from this the transfer functions can be calculated. The second and third methods are based on the reciprocity of the transducer. The second utilizes a calibrated hydrophone to measure the transmitted field. In the third method, a pulse is transmitted by the transducer, which impinges on a reflector and is received again by the same transducer. In both methods, the response combined with the transducer impedance and beam profiles enables the calculation of the transfer function.

The proposed methods are useful to select the optimal piezoelectric material (PZT, single crystal) for transducers used in reception only, such as in certain 3D scanning designs and superharmonic imaging, and for selected experiments like single bubble behavior.

We tested and compared these methods on two unfocused single element transducers, one commercially available (radius 6.35 mm, centre frequency 2.25 MHz) the other custom built (radius 0.75 mm, centre frequency 4.3 MHz). The methods were accurate to within 15%.  相似文献   


16.
This paper describes the use of air-coupled ultrasonic tomography for the simultaneous measurement of flow and temperature variations in gases. Air-coupled ultrasonic transducers were used to collect through-transmission data from a heated gas jet. A transducer pair was scanned in two-dimensional sections at an angle to the jet, and travel time and amplitude data recorded along various paths in counter-propagating directions. Parallel-beam tomographic reconstruction techniques allowed images to be formed of variations in either temperature or flow velocity. Results have been obtained using heated jets, where it has been shown that it is possible to separate the two variables successfully.  相似文献   

17.
Scatterer size estimates from ultrasonic backscatter coefficient measurements have been used to differentiate diseased tissue from normal. A low echo signal-to-noise ratio (eSNR) leads to increased bias and variance in scatterer size estimates. One way to improve the eSNR is to use coded excitation (CE). The normalized backscatter coefficient was measured from three tissue-mimicking phantoms by using CE and conventional pulsing (CP) techniques. The three phantoms contained randomly spaced glass beads with median diameters of 30, 45, and 82 mum, respectively. Measurements were made with two weakly focused, single-element transducers (f(0)=5 MHz and f(0)=10 MHz). For CE, a linear frequency modulated chirp with a time bandwidth product of 40 was used and pulse compression was accomplished by the use of a Wiener filter. Preliminary results indicated that improved estimation bias versus penetration depth was obtained by using CE compared to CP. The depth of penetration, where the accuracy of scatterer diameter estimates (absolute divergence <25%) were obtained with the 10 MHz transducer, was increased up to 50% by using CE versus CP techniques. In addition, for a majority of the phantoms, the increase in eSNR from CE resulted in a modest reduction in estimate variance versus depth of penetration.  相似文献   

18.
This paper presents the latest development of a lead-free piezoelectric ceramic and its application to transducers suitable for high-frequency ultrasonic imaging. A lead-free piezoelectric ceramic with formula of (K0.5Na0.5)0.97Li0.03(Nb0.9 Ta0.1)O3 (abbreviated as KNLNT-0.03/0.10) was fabricated and characterized. The material was found to have a clamped dielectric constant ε33S/ε0 = 890, piezoelectric coefficient d33 = 245 pC/N, electromechanical coupling factor kt = 0.42 and Curie temperature Tc > 300 °C. High-frequency (40 MHz) ultrasound transducers were successfully fabricated with the lead-free material. A representative lead-free transducer had a bandwidth of 45%, two-way insertion loss of -18 dB. This performance is comparable to reported performances of popular lead-based transducers. The comparison results suggest that the lead-free piezoelectric material may serve as an alternative to lead-based piezoelectric materials for high-frequency ultrasonic transducer applications.  相似文献   

19.
Ultrasonic transducers made with 1-3 connectivity piezocomposites are frequently used in Medical applications and nondestructive testing. When the transducer is used for special applications as, for instance air-coupled transmission, it is necessary to compensate for the high difference of acoustic impedance between transducer and medium using high amplitude pulses to generate high acoustic signal. Thus, the nonlinear behavior of the transducer must be taken into account in similar application conditions. The newly developed method, which performs the nonlinear characterization with burst signal excitation near the thickness resonance frequency, is based on the measure of the current as well as the vibration velocity of the piezocomposite transducer. The current of the stationary response is measured before the end of the burst signal excitation. Burst excitation enables us to measure the nonlinear characterization without producing overheating in the transducers. The amplitude level dependence of mechanical losses tandelta(m) and the stiffness increases |Deltac/c(0)| have been studied, as well as the velocity dependence of a point of the transducer, measured with a laser vibrometer. In this method, the power level applied to the transducers can be higher than other nonlinear measurement methods, providing measurements of high accuracy.  相似文献   

20.
本文选择了高聚物中杨氏模量较大、损耗较小的聚苯硫醚作为复合棒型换能器的前盖板。计算了聚苯硫醚棒中的纵波传播速度,研究了基于聚苯硫醚材料的复合棒型换能器的等效电路设计方法。利用有限元方法计算了换能器谐振频率、轴向应变分布、平均耗散功率等性能参数。对本文研制的前盖板为聚苯硫醚、后盖板为钢(1#)和前后盖板均为聚苯硫醚(2#)的两个换能器进行了测试。结果表明,理论计算的谐振频率与实验测试相吻合;两个换能器的振幅均与所施加的电压成正比,且1#换能器的振幅电压比更大;两个换能器的耗散功率与外加电压平方成正比,在应变较大处耗散功率较高,导致局部升温明显,测得两个换能器温度最高处均位于应变最大位置处。1#换能器的前后振幅比为26,与同频率的金属组件换能器相比,若后盖板为尺寸相同的钢材,前盖板采用聚苯硫醚材料能够显著提高换能器的前后振幅比,且带宽也较大。   相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号