首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Single crystal platelets of FeBO3 are used as magnetoelastically excited shear wave transducers in the 10–100MHz region. Due to a strong dependence of the elastic stiffness on an applied magnetic dc field the resonance frequency is magnetically tunable in a region of about 25 percent around the centre frequency. A pulse-echo experiment was used to compare the conversion efficiencies of the FeBO3 transducer and a conventional quartz transducer. The insertion losses were found to be approximately equal for both transducers and in accordance with the calculated values.  相似文献   

2.
R.E. Challis 《Ultrasonics》1982,20(4):168-172
Transient diffraction phenomena in the field of a piston transducer have been explained theoretically in terms of the direct and edge wave contributions to the piston response. Previous experimental studies by other workers have verified this concept for single cycles of 4 MHz radiation. Faster transients are difficult to study using thin piezoelectric transducers due to transducer resonance. Thick piezoelectric transducers of very low resonant frequency can be used to generate and receive step function acoustic transients with rise times of 20 ns or less and the problems of transducer resonance can be avoided. Experimental results are presented which show that when such a step function is propagated between two thick transducers the time course of the received wave can be explained in terms of the direct wave/edge wave model in conjunction with the theory of transient reverberations in piezoelectric elements.  相似文献   

3.
Recently, the measurement of phase transfer functions (PTFs) of piezoelectric transducers has received more attention. These PTFs are useful for e.g. coding and interference based imaging methods, and ultrasound contrast microbubble research. Several optical and acoustic methods to measure a transducer’s PTF have been reported in literature. The optical methods require a setup to which not all ultrasound laboratories have access to. The acoustic methods require accurate distance and acoustic wave speed measurements. A small error in these leads to a large error in phase, e.g. an accuracy of 0.1% on an axial distance of 10 cm leads to an uncertainty in the PTF measurement of ±97° at 4 MHz. In this paper we present an acoustic pulse-echo method to measure the PTF of a transducer, which is based on linear wave propagation and only requires an estimate of the wave travel distance and the acoustic wave speed. In our method the transducer is excited by a monofrequency sine burst with a rectangular envelope. The transducer initially vibrates at resonance (transient regime) prior to the forcing frequency response (steady state regime). The PTF value of the system is the difference between the phases deduced from the transient and the steady state regimes. Good agreement, to within 7°, was obtained between KLM simulations and measurements on two transducers in a 1-8 MHz frequency range. The reproducibility of the method was ±10°, with a systematic error of 2° at 1 MHz increasing to 16° at 8 MHz. This work demonstrates that the PTF of a transducer can be measured in a simple laboratory setting.  相似文献   

4.
Cavitation bubbles have been recognized as being essential to many applications of ultrasound. Temporal evolution and spatial distribution of cavitation bubble clouds induced by a focused ultrasound transducer of 1.2 MHz center frequency are investigated by high-speed photography. It is revealed that at a total acoustic power of 72 W the cavitation bubble cloud first emerges in the focal region where cavitation bubbles are observed to generate, grow, merge and collapse during the initial 600 μs. The bubble cloud then grows upward to the post-focal region, and finally becomes visible in the pre-focal region. The structure of the final bubble cloud is characterized by regional distribution of cavitation bubbles in the ultrasound field. The cavitation bubble cloud structure remains stable when the acoustic power is increased from 25 W to 107 W, but it changes to a more violent form when the acoustic power is further increased to 175 W.  相似文献   

5.
Quantitative experimental observations of single-bubble cavitation in viscoelastic media that would enable validation of existing models are presently lacking. In the present work, single bubble cavitation is induced in an agar gel using a 1.15 MHz high intensity focused ultrasound transducer, and observed using a focused single-element passive cavitation detection (PCD) transducer. To enable quantitative observations, a full receive calibration is carried out of a spherically focused PCD system by a bistatic scattering substitution technique that uses an embedded spherical scatterer and a hydrophone. Adjusting the simulated pressure received by the PCD by the transfer function on receive and the frequency-dependent attenuation of agar gel enables direct comparison of the measured acoustic emissions with those predicted by numerical modeling of single-bubble cavitation using a modified Keller-Miksis approach that accounts for viscoelasticity of the surrounding medium. At an incident peak rarefactional pressure near the cavitation threshold, period multiplying is observed in both experiment and numerical model. By comparing the two sets of results, an estimate of the equilibrium bubble radius in the experimental observations can be made, with potential for extension to material parameter estimation. Use of these estimates yields good agreement between model and experiment.  相似文献   

6.
固体板背覆薄层特性的低频超声反演方法研究   总被引:3,自引:0,他引:3  
研究了应用低频超声的反射频谱对固体板厚度及背覆薄层的各特征参数(包括厚度、声速、密度、衰减、声阻抗率、声时)进行反演的方法。从灵敏度函数、目标函数及误差传递方程的角度,对应用反射频谱的谐振频率或幅度谱反演模型系统的单参数和双参数的方法进行了分析讨论。实验使用中心频率为7MHz的探头检测铝板/聚合物薄层样品,在同样的条件下,谐振频率法和幅度谱法反演的单参数反演效果相当,谐振频率方法的双参数反演效果优于幅度谱方法,前者薄层声阻抗率和声时同时反演的平均误差为3.4%和4.7%,而后者没有得到结果。   相似文献   

7.
The aim of this work was to show the applicability of light diffraction tomography on airborne ultrasound in the frequency range 40 kHz-2 MHz. Seven different air-coupled transducers were measured to show the method's performance regarding linearity, absolute pressure measurements, phase measurements, frequency response, S/N ratio and spatial resolution. A calibrated microphone and the pulse-echo method were used to evaluate the results. The absolute measurements agreed within the calibrated microphone's uncertainty range. Pulse waveforms and corresponding FFT diagrams show the method's higher bandwidth compared with the microphone. Further, the method offers non-perturbing measurements with high spatial resolution, which was especially advantageous for measurements close to the transducer surfaces. The S/N ratio was higher than or in the same range as that of the two comparison methods.  相似文献   

8.
Interest in using ultrasound energy in wound management and intracellular drug delivery has been growing rapidly. Development and treatment optimization of such non-diagnostic applications requires a fundamental understanding of interactions between the acoustic wave and phospholipid membranes, be they cell membranes or liposome bilayers. This work investigates the changes in membrane permeation (leakage mimicking drug release) in vitro during exposure to ultrasound applied in two frequency ranges: “conventional” (1 MHz and 1.6 MHz) therapeutic ultrasound range and low (20 kHz) frequency range. Phospholipids vesicles were used as controllable biological membrane models. The membrane properties were modified by changes in vesicle dimensions and incorporation of poly(ethylene glycol) i.e. PEGylated lipids. Egg phosphatidylcholine vesicles with 5 mol% PEG were prepared with sizes ranging from 100 nm to 1 μm. Leakage was quantified in terms of temporal fluorescence intensity changes observed during carefully controlled ultrasound ON/OFF time intervals. Custom-built transducers operating at frequencies of 1.6 MHz (focused) and 1.0 MHz (unfocused) were used, the Ispta of which were 46.9 W/cm2 and 3.0 W/cm2, respectively. A commercial 20 kHz, point-source, continuous wave transducer with an Ispta of 0.13 W/cm2 was also used for comparative purposes. Whereas complete leakage was obtained for all vesicle sizes at 20 kHz, no leakage was observed for vesicles smaller than 100 nm in diameter at 1.6 or 1.0 MHz. However, introducing leakage at the higher frequencies became feasible when larger (greater than 300 nm) vesicles were used, and the extent of leakage correlated well with vesicle sizes between 100 nm and 1 μm. This observation suggests that physico-chemical membrane properties play a crucial role in ultrasound mediated membrane permeation and that low frequency (tens of kilohertz) ultrasound exposure is more effective in introducing permeability change than the “conventional” (1 MHz) therapeutic one. The experimental data also indicate that the leakage level is controlled by the exposure time. The results of this work might be helpful to optimize acoustic field and membrane parameters for gene or drug delivery. The outcome of this work might also be useful in wound management.  相似文献   

9.
Previous experimental studies showed that powerful heating of nanoparticles by a laser pulse using energy density greater than 100 mJ/cm2, could induce vaporization and generate microbubbles. When ultrasound is introduced at the same time as the laser pulse, much less laser power is required. For therapeutic applications, generation of microbubbles on demand at target locations, e.g. cells or bacteria can be used to induce hyperthermia or to facilitate drug delivery. The objective of this work is to develop a method capable of predicting photothermal and acoustic parameters in terms of laser power and acoustic pressure amplitude that are needed to produce stable microbubbles; and investigate the influence of bubble coalescence on the thresholds when the microbubbles are generated around nanoparticles that appear in clusters.

We develop and solve here a combined problem of momentum, heat and mass transfer which is associated with generation and growth of a microbubble, filled with a mixture of non-vaporized gas (air) and water vapor. The microbubble’s size and gas content vary as a result of three mechanisms: gas expansion or compression, evaporation or condensation on the bubble boundary, and diffusion of dissolved air in the surrounding water. The simulations predict that when ultrasound is applied relatively low threshold values of laser and ultrasound power are required to obtain a stable microbubble from a single nanoparticle. Even lower power is required when microbubbles are formed by coalescence around a cluster of 10 nanoparticles. Laser pulse energy density of 21 mJ/cm2 is predicted for instance together with acoustic pressure of 0.1 MPa for a cluster of 10 or 62 mJ/cm2 for a single nanoparticle. Those values are well within the safety limits, and as such are most appealing for targeted therapeutic purposes.  相似文献   


10.
电容式微机械超声换能器具有宽频带和易于制造二维阵列等优势,已经成为一种重要的新型超声换能器。该文针对图像声呐系统对新型超声换能器的迫切需求,提出了一种电容式微机械超声换能器结构和参数,并利用硅微加工技术制备出了该换能器,最后对其主要性能参数进行了测试和分析。测试结果表明该换能器具有发射和接收超声波的功能,中心工作频率为1.965 MHz,6 dB相对带宽达到109.4%,在1 MHz、2 MHz和3 MHz频率时的接收灵敏度分别为-218.29 d B、-219.39 dB和-218.11 dB。该文研制的电容式微机械超声换能器显示出了优秀的宽频带特性,且工作频率和接收灵敏度性能均基本满足了高频图像声呐系统的需求。  相似文献   

11.
In this study, the phenomenon of higher harmonic thickness resonance of a piezoelectric transducer was used to investigate potentially additional sensitivity at the third harmonic frequency for conventional medical transducers. The motivation for this research is that some applications in medical ultrasound (e.g. third harmonic transmit phasing and contrast imaging) need probes which are sensitive around both the fundamental and third harmonic frequencies, and that these higher harmonic thickness modes, although often considered as undesired, might be used beneficially. The novelty aspect in this study is the presented transmit and receive potential at both the fundamental and third harmonic of a conventional cardiac probe with modified electrical tuning. Elements of an experimental PZT-based phased-array probe (fc = 3 MHz, 64 elements, element width = 0.3 mm, elevation aperture = 13 mm) were electrically retuned with series inductors around the third harmonic resonance frequency at 10 MHz. Hydrophone measurements with 10-MHz-tuned elements showed that, as compared to a conventionally tuned element, the transmit transfer function at the third harmonic increased more than 23 dB, while the sensitivity at the fundamental frequency was only 6 dB lower. Pulse-echo measurements showed that the two-way transfer function of a 10-MHz-tuned element resulted in 20 dB increased sensitivity around the third harmonic as compared to an untuned element. Simulated transfer functions, from both a 1D KLM and 2D finite element model of an element of the experimental array transducer, confirmed the measured sensitivity peaks at the fundamental and third harmonic. In conclusion, this study demonstrated the effect of changing the electrical tuning on a conventional array transducer which increased the sensitivity around the third harmonic resonance frequency, while maintaining good sensitivity at the fundamental frequency.  相似文献   

12.
微泡对高强度聚焦超声(HIFU)治疗具有增效作用,而HIFU治疗中不同声学条件下微泡对HIFU治疗焦域的影响尚不清楚。本文基于声传播方程、Yang-Church气泡运动方程、生物热传导方程、时域有限差分法(FDTD)、龙格-库塔(RK)法数值仿真研究输入功率、激励频率和气泡初始半径对HIFU在含气泡体模中形成焦域的影响,并利用含Sono Vue造影剂的仿组织体模研究进行实验验证。结果表明,增大输入功率、气泡初始半径和升高激励频率均可增大焦域,随着输入功率的增大,焦域形状可能发生变化,而随着激励频率升高和气泡初始半径的增大,焦域会向远离换能器的方向移动。  相似文献   

13.
Gudra T  Opielinski KJ 《Ultrasonics》2006,44(Z1):e679-e683
The main component of every device used for investigating internal object structure by Ultrasound Transmission Tomography (UTT) is a special ultrasonic probe. This paper presents the structure of model multielement ring probe for examining objects using this method in divergent ray projection geometry. The probe is made up of 1024 rectangular separate piezoelectric transducers working at frequency f=1.7 MHz, placed inside a ring with diameter D=30 cm and height h=9 cm. Each element of the probe is equipped with a quarter-wave matching layer. All the transducers function as transmitters and receivers, and can be joined in groups both during transmitting and during receiving. Some examples of admittance characteristics of a single piezoelectric transducer and examples of shapes of pulses generated and received by particular transducers were presented. Important factors affecting the measurement resolution are the sizes of the active surface of the transducers.  相似文献   

14.
Study for imaging of inside bone using FM-chirp pulse compression system   总被引:2,自引:0,他引:2  
Irie T  Ohdaira E  Itoh K 《Ultrasonics》2004,42(1-9):713-716
We measured the attenuation of ultrasound in animal bone in vitro, and determined successfully the correct dynamic range for the detection of echo signals from inside the bone. It was possible to display a B-mode image of a 6-mm thick porcine rib bone using a high frequency (5 MHz) transducer. However, it was difficult to obtain the image of a large bone (20-mm thick femur). This paper describes a possibility of the improvement for the detection of echoes from inside the bone using the FM-chirp pulse. An ultrasonic wave generator that generates the FM-chirp pulse for a frequency range of 100 KHz to 5 MHz was fabricated. And the pulse was transmitted from a transducer and received by a hydrophone in the water. The received waveform and the frequency spectrum were displayed on an oscilloscope. We measured the amplitude spectrum of the received waves before and after inserting a sample bone between the transducer and the hydrophone. In the experiment, three types of focused transducers (0.5, 1 and 2.25 MHz) and three kinds of sample bones (spine, femur and rib of a pig) were used. From the results of the measurement, we could find the useful information for imaging of inside the bone.  相似文献   

15.
Cowell DM  Freear S 《Ultrasonics》2008,48(2):98-108
A novel switched excitation method for linear frequency modulated excitation of ultrasonic transducers in pulse compression systems is presented that is simple to realise, yet provides reduced signal sidelobes at the output of the matched filter compared to bipolar pseudo-chirp excitation. Pulse compression signal sidelobes are reduced through the use of simple amplitude tapering at the beginning and end of the excitation duration. Amplitude tapering using switched excitation is realised through the use of intermediate voltage switching levels, half that of the main excitation voltages. In total five excitation voltages are used creating a quinary excitation system. The absence of analogue signal generation and power amplifiers renders the excitation method attractive for applications with requirements such as a high channel count or low cost per channel. A systematic study of switched linear frequency modulated excitation methods with simulated and laboratory based experimental verification is presented for 2.25 MHz non-destructive testing immersion transducers. The signal to sidelobe noise level of compressed waveforms generated using quinary and bipolar pseudo-chirp excitation are investigated for transmission through a 0.5 m water and kaolin slurry channel. Quinary linear frequency modulated excitation consistently reduces signal sidelobe power compared to bipolar excitation methods. Experimental results for transmission between two 2.25 MHz transducers separated by a 0.5 m channel of water and 5% kaolin suspension shows improvements in signal to sidelobe noise power in the order of 7–8 dB. The reported quinary switched method for linear frequency modulated excitation provides improved performance compared to pseudo-chirp excitation without the need for high performance excitation amplifiers.  相似文献   

16.
Posakony GJ  Greenwood LR  Ahmed S 《Ultrasonics》2006,44(Z1):e445-e449
Multibubble standing wave patterns can be generated from a flat piezoceramic transducer element radiating into water. By adding a second transducer positioned at 90 degrees from the transducer generating the standing wave, a 3-dimensional volume of stable single bubbles can be established. Further, the addition of the second transducer stabilizes the bubble pattern so that individual bubbles may be studied. The size of the bubbles and the separation of the standing waves depend on the frequency of operation. Two transducers, operating at frequencies above 500 kHz, provided the most graphic results for the configuration used in this study. At these frequencies stable bubbles exhibit a bright sonoluminescence pattern. Whereas stable SBSL is well-known, stable MBSL has not been previously reported. This paper includes discussions of the acoustic responses, standing wave patterns, and pictorial results of the separation of individual bubble sonoluminescence in a multibubble sonoluminescence environment.  相似文献   

17.
A laboratory-scale study on acoustic scattering from a single bubble undergoing dissolution in undersaturated fresh water is presented. Several experiments are performed with the acoustic source driven with five-cycle tone bursts, center frequency of 120 kHz, to insonify a single bubble located on axis of the combined beam of the set of transducers. The bubble is placed on a fine nylon thread located in the far field of the transducer set, arranged in bistatic configuration, in a tank filled with undersaturated water. Backscattered waveforms from the bubble target are acquired every few seconds for several hours until the bubble has completely dissolved, and detailed dissolution curves are produced from the acoustic data. The rate of bubble dissolution is calculated using the solution developed by Epstein and Plesset [J. Chem. Phys. 18, 1505-1509 (1950)]. The results of the experiments performed are in agreement with the calculations.  相似文献   

18.
A comparison between in vitro and in vivo experiments conducted to investigate the acoustic properties of a novel, 1.2 μm diameter poly(lactic-co-glycolic acid) (50:50) (PLGA) ultrasound contrast agent, the development of which was described previously by us, is presented. A pulse-echo setup was used to determine enhancement in vitro. Additional in vitro studies further characterized the hollow microcapsules, including resonance frequency from attenuation measurements (from 2.25 to 15 MHz) and temperature effects (25 °C vs. 37 °C). In vivo, four rabbits received intravenous injections of the agent (dose range: 0.005–0.13 ml/kg). Quantitative in vivo dose–responses were calculated off-line using spectral power analysis of audio Doppler signals acquired from a custom-made 10 MHz cuff transducer placed around the surgically exposed distal aorta. This frequency was chosen since the very shallow scanning depths encountered in rabbits, in particular for the cuff transducer placed directly around the vessel, necessitates the use of high frequency imaging devices with sufficient spatial resolution to enable meaningful measurements. For qualitative assessments, two rabbits were imaged pre- and post-contrast administration (dose: 0.1 ml/kg) in power Doppler mode. Significant acoustic enhancements (up to 24 dB) were reported both in vitro and in vivo. Moreover, the rabbits did not show any adverse side effects from multiple injections (>20) of the agent. Measured in vitro resonance frequency between 3.09 and 3.49 MHz was lower than predicted for a similar sized free bubble, potentially due to capsule wall structure. Minimal loss of signal (4 dB) was observed at 25 °C over 20 min of insonation at 5 MHz but at 37 °C the signal dropped close to base line within the first 5 min. This temperature sensitivity could be due to loss of capsule integrity (and hence loss of gas). Potential causes include increased hydrolysis or polymer softening and increased water uptake by the shell at temperatures closer to the glass transition temperature (Tg).  相似文献   

19.
提出一种三元径向复合圆柱压电超声换能器,并对其径向振动特性进行了研究。基于弹性力学理论及机电类比原理,导出了柱坐标系中分割处理径向极化压电陶瓷管准厚度模振动及薄壁短圆管径向振动的机电等效电路;利用径向力和振速连续的边界条件,得出了径向复合圆柱压电换能器系统的径向振动机电等效电路及其共振频率方程。探讨了换能器径向共振频率及有效机电耦合系数随其几何尺寸的变化关系。研究表明,换能器的径向共振频率及有效机电耦合系数随其内芯半径和预应力管壁厚度增大而降低。研制了一些径向复合圆柱压电换能器,并对其径向共振频率进行了测试。结果表明,理论与实验结果基本一致。   相似文献   

20.
Numerical investigation of a point spread function for a optoacoustic transducer array is described. Analysis of the minimal reconstructed dimension for an optoacoustic image of a point source of spherical waves is performed within the proposed approach. The influence of the array geometrical parameters, number of array transducers, and the frequency band of a single transducer on the lateral resolution in the image plane is investigated in detail. It is demonstrated that the lateral resolution obtained with the help of a transducer array in the image plane is determined unambiguously by the frequency band of a transducer, the flare angle of the array, and the transducer width and does not depend on the number of transducers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号