首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 171 毫秒
1.
A theory of nonlinear AC response in coated composites   总被引:1,自引:0,他引:1       下载免费PDF全文
A method for determining effective dielectric responses of Kerr-like coated nonlinear composites under the alternating current (AC) electric field is proposed by using perturbation approach. As an example, we have investigated the composite with coated cylindrical inclusions randomly embedded in a host under an external sinusoidal field with finite frequency ω. The local field and potential of composites in general consists of components with all harmonic frequencies. The effective nonlinear AC responses at all harmonics are induced by the coated nonlinear composites because of the nonlinear constitutive relation. Moreover, we have derived the formulae of effective nonlinear AC responses at the fundamental frequency and the third harmonic in the dilute limit.  相似文献   

2.
徐文龙  张鞠成  李霞  徐冰俏  陶贵生 《中国物理 B》2013,22(1):10203-010203
In this paper, an approach to the design of shielded radio-frequency (RF) phased-array coils for magnetic resonance imaging (MRI) is proposed. The target field method is used to find current densities distributed on primary and shield coils. The stream function technique is used to discretize current densities and to obtain the winding patterns of the coils. The corresponding highly ill-conditioned integral equation is solved by the Tikhonov regularization with a penalty function related to the minimum curvature. To balance the simplicity and smoothness with the homogeneity of the magnetic field of the coil’s winding pattern, the selection of a penalty factor is discussed in detail.  相似文献   

3.
We study the pumped spin current of an interacting quantum dot tunnel coupled to a single lead in the presence of electron spin resonance (ESR) field. The spin decoherence in the dot is included by the Bffttiker approach. Using the nonequilibrium Green's function technique, we show that ESR-induced spin flip can generate finite spin current with no charge transport. Both the Coulomb interaction and spin decoherence decrease the amplitude of spin current. The dependence of pumped spin current on the intensity and frequency of ESR field, and the spin decoherence is discussed.  相似文献   

4.
Resonating properties of passive spherical optical microcavities   总被引:1,自引:0,他引:1  
As an optically pumped device, the lasing characteristics of a spherical microcavity laser depend on the optical pumping processes. These characteristics can be described in term of the Q factor and the optical field distribution in a microsphere. We derived analytical expressions and carried out numerical calculation for Q factor and optical field. The Q factor is found to be oscillatory functions of the radius of a microsphere and the pumping wavelength, and the pumping efficiency for a resonating microsphere is much higher than that for an anti-resonating microsphere. Using tunable lasers as pumping sources is suggested in order to achieve a higher pumping efficiency. Numerical calculation on optical field distribution in spherical microcavities shows that a well focused Gaussian beam is a suitable incident wave for cavity quantum electrodynamics experiments in which strong confinement of optical field in the center of a microsphere is requested, but higher order spherical wave should be used instead  相似文献   

5.
A perturbative approach is used to study the AC response of nonlinear compostie media,which obey a current-field relation of the form J=σE χ|E|^2E with comp[onents having nonlinear response at finite frequencies.For a sinusoidal applied field,we extend the local potential in terms of sinusoidal components at fundamental frequency and high-order harmonic frequencies to treat the nonlinear comosites.For nonlinear composite media with a low concentrations of spherical inclusions,we give the formulae of the nonlinear effective AC susceptibility χ3ω at the third harmonic frequency.  相似文献   

6.
A rotamak is one kind of compact spherically shaped magnetic-confinement device. In a rotamak the plasma current is driven by means of rotating magnetic field (RMF). The driven current can reverse the original equilibrium field and generate a field-reversed-configuration. In a conventional rotamak, a toroidal field (TF) is not necessary for the RMF to drive plasma current, but it was found that the present of an additional TF can influence the RMF current drive. In this paper the effect of TF on the RMF current drive in a rotamak are investigated in some detail. The experimental results show that addition of TF increases the RMF driven current greatly and enhances the RMF penetration dramatically. Without TF, the RMF can only penetrate into plasma in the edge region. When a TF is added, the RMF can reach almost the whole plasma region. This is an optimal strength of toroidal magnetic field for getting maximum plasma current when Bv and radio frequency generator power are fixed. Besides driving current, the RMF generates high harmonic fields in rotamak plasma. The effect of TF on the harmonic field spectra are also reported.[第一段]  相似文献   

7.
王龙庆  王为民 《中国物理 B》2014,23(2):28703-028703
Significant high magnetic gradient field strength is essential to obtaining high-resolution images in a benchtop mag- netic resonance imaging (BT-MRI) system with permanent magnet. Extending minimum wire spacing and maximum wire width of gradient coils is one of the key solutions to minimize the maximum current density so as to reduce the local heating and generate higher magnetic field gradient strength. However, maximum current density is hard to optimize together with field linearity, stored magnetic energy, and power dissipation by the traditional target field method. In this paper, a new multi-objective method is proposed to optimize the maximum current density, field linearity, stored magnetic energy, and power dissipation in MRI gradient coils. The simulation and experimental results show that the minimum wire spacings are improved by 159% and 62% for the transverse and longitudinal gradient coil respectively. The maximum wire width increases from 0.5 mm to 1.5 mm. Maximum gradient field strengths of 157 mT/m and 405 mT/m for transverse and lon- gitudinal coil are achieved, respectively. The experimental results in BT-MRI instrument demonstrate that the MRI images with in-plane resolution of 50 ~tm can be obtained by using the designed coils.  相似文献   

8.
A novel kind of SC (superconducting) solenoid coil is designed to satisfy the homogeneity requirement of the magnetic field. In this paper, we first calculate the current density distribution of the solenoid coil section through the linear programming method. Then a traditional solenoid and a nonrectangular section solenoid are designed to produce a central field up to 7 T with a homogeneity to the greatest extent. After comparision of the two solenoid coils designed in magnet field quality, fabrication cost and other aspects, the new design of the nonrectangular section of a solenoid coil can be realized through improving the techniques of framework fabrication and winding. Finally, the outlook and error analysis of this kind of SC magnet coil are also discussed briefly.  相似文献   

9.
郝宽胜  黄松岭  赵伟  王珅 《中国物理 B》2011,20(6):68104-068104
This paper presents an analytical method for electromagnetic acoustic transducers (EMATs) under voltage excitation and considers the non-uniform distribution of the biased magnetic field. A complete model of EMATs including the non-uniform biased magnetic field, a pulsed eddy current field and the acoustic field is built up. The pulsed voltage excitation is transformed to the frequency domain by fast Fourier transformation (FFT). In terms of the time harmonic field equations of the EMAT system, the impedances of the coils under different frequencies are calculated according to the circuit-field coupling method and Poynting’s theorem. Then the currents under different frequencies are calculated according to Ohm’s law and the pulsed current excitation is obtained by inverse fast Fourier transformation (IFFT). Lastly, the sequentially coupled finite element method (FEM) is used to calculate the Lorentz force in the EMATs under the current excitation. An actual EMAT with a two-layer two-bundle printed circuit board (PCB) coil, a rectangular permanent magnet and an aluminium specimen is analysed. The coil impedances and the pulsed current are calculated and compared with the experimental results. Their agreement verified the validity of the proposed method. Further- more, the influences of lift-off distances and the non-uniform static magnetic field on the Lorentz force under pulsed voltage excitation are studied.  相似文献   

10.
Superconducting magnet system for a 28GHz ECR ion source has been designed.The maximum axial magnetic fields are 4T at the rf injection side and 2T at the beam extraction side,respectively.The hexapole magnetic field is about 2T on the inner surface of the plasma chamber.The superconducting coils consist of six solenoids and six racetrack windings for a hexapole field.Two kinds of coil arrangements were investigated:one is an arrangement in which the hexpole coil is located in the bore of the solenoids,and another is the reverse of it.The coils use NbTi-Copper conductor and are bath-cooled in liquid helium.The six solenoids are excited with individual power supplies to search for the optimal axial field distribution.The current leads use high Tc material and the cryogenic system is operated in LHe re-condensation mode using small refrigerators.The thermal insulated supports of the cold mass have also been designed based on the calculated results of the magnetic force.The heat loads to 70K and LHe stages were estimated from the design of the supports,the current leads and so on.  相似文献   

11.
胡洋  王秋良  李毅  朱旭晨  牛超群 《物理学报》2016,65(21):218301-218301
在磁共振成像设备中,为了消除目标区域内的高阶谐波磁场分量,传统方法采用无源匀场,但该方法匀场精度较低,针对性较差,适用于全局匀场,而有源匀场则可以通过优化线圈分布来产生所需要的特定的磁场分布.但是,由于匀场线圈线型的复杂度会随着线圈阶数的增加而增加,难以满足设计需要,因此本文提出了一种用于磁共振成像超导匀场线圈系统的多变量非线性优化设计方法.该方法基于边界元方法,将匀场线圈所产生的磁场与目标磁场之间的偏差作为目标函数,线匝间距、线圈半径等作为约束条件,通过非线性优化算法,得到满足设计要求的线圈分布.通过一个中心磁场为0.5 T的开放式双平面磁共振成像超导轴向匀场线圈的设计案例,说明本方法具有计算效率高、灵活性好的特点.  相似文献   

12.
A one-dimensional approach for fast, robust, automatic adjustment of on-axis shims on high-resolution NMR spectrometers based on polynomial fitting of field inhomogeneity is described. Spherical harmonic and nonspherical harmonic terms of the field distribution of shim coils are precalibrated as polynomial coefficients by successively changing shim settings. This method greatly simplifies the shim precalibration and optimization procedures and is readily to be extended to three-dimensions to include off-axis shims.  相似文献   

13.
The use of high magnetic fields increases the sensitivity and spectral dispersion in magnetic resonance spectroscopy (MRS) of brain metabolites. Practical limitations arise, however, from susceptibility-induced field distortions, which are increased at higher magnetic field strengths. Solutions to this problem include optimized shimming, provided that active, i.e., electronic, shimming can operate over a sufficient range. To meet our shim requirements, which were an order of magnitude greater than the active shim capacity of our 7T MR system, we developed a combined passive and active shim approach. Simple geometries of ferromagnetic shim elements were derived and numerically optimized to generate a complete set of second-order spherical harmonic shim functions in a modular manner. The major goals of the shim design were maximization of shim field accuracy and ease of practical implementation. The theoretically optimized ferro-shim geometries were mounted on a cylindrical surface and placed inside the magnet bore, surrounding the subject's head and the RF coil. Passive shimming generated very strong shim fields and eliminated the worst of the field distortions, after which the field was further optimized by flexible and highly accurate active shimming. Here, the passive-shimming procedure was first evaluated theoretically, then applied in phantom studies and subsequently validated for in vivo 1H MRS in the macaque visual cortex. No artifacts due to the passive shim setup were observed; adjustments were reproducible between sessions. The modularity and the reduction to two pieces per shim term in this study is an important simplification that makes the method applicable also for passive shimming within single sessions. The feasibility of very strong, flexible and high-quality shimming via a combined approach of passive and active shimming is of great practical relevance for MR imaging and spectroscopy at high field strengths where shim power is limited or where shimming of specific anatomical regions inherently requires strong shim fields.  相似文献   

14.
何川  王秋良  白烨 《低温与超导》2006,34(3):183-185,209
文中把目标场法引入到悬浮超导球体的球形线圈设计中,根据目标场法产生均匀磁场的原理,通过离散化绕组来近似处理球形线圈在超导球体和球形线圈的间隙内产生均匀磁场的电流密度分布规律。利用有限元分析和验证,在超导球体与球形线圈之间的间隙内产生了具有很好均匀性的悬浮磁场,这会明显提高超导球体悬浮的刚度和稳定性。  相似文献   

15.
The main magnetic fields of mobile nuclear magnetic resonance (NMR) magnets differ from those of conventional NMR and magnetic resonance imaging (MRI) magnets. In the Halbach magnet, the main field B 0 is perpendicular to the longitudinal axis, the symmetry of the current distribution with respect to the symmetry of the magnetic field differs from that in conventional target-field applications, and the current distribution on the coil surface cannot be expressed in terms of periodic basis functions. To obtain the winding pattern of the coil, an efficacious target-field approach. The surface of a coil is divided into small discrete elements, where each element is represented by a magnetic dipole. From the stream function of the elements, the resultant magnetic field is calculated. The optimization strategy follows an objective function defined by the power dissipation or efficiency of the coil. This leads to the optimum stream function on the coil surface, whose contour lines define the winding patterns of the coil. This paper shows winding patterns designed of shim coils for Halbach magnet and illustrates the craft of a shim coil using flexible printed circuit board. The performance of the coils is verified by simulating the fields they produce over the sensitive volume.  相似文献   

16.
High quality magnetic field homogenization of the human brain (i.e. shimming) for MR imaging and spectroscopy is a demanding task. The susceptibility differences between air and tissue are a longstanding problem as they induce complex field distortions in the prefrontal cortex and the temporal lobes. To date, the theoretical gains of high field MR have only been realized partially in the human brain due to limited magnetic field homogeneity.A novel shimming technique for the human brain is presented that is based on the combination of non-orthogonal basis fields from 48 individual, circular coils. Custom-built amplifier electronics enabled the dynamic application of the multi-coil shim fields in a slice-specific fashion. Dynamic multi-coil (DMC) shimming is shown to eliminate most of the magnetic field inhomogeneity apparent in the human brain at 7 T and provided improved performance compared to state-of-the-art dynamic shim updating with zero through third order spherical harmonic functions. The novel technique paves the way for high field MR applications of the human brain for which excellent magnetic field homogeneity is a prerequisite.  相似文献   

17.
梯度和匀场线圈性能的好坏直接影响磁共振成像质量.常规线圈在成像过程中存在一些固有的不足,如产生的磁场形态单一、不灵活,需要的线圈种类较多,结构较复杂等.而新型矩阵梯度线圈可以较好地弥补这些缺点.本文首先介绍了矩阵梯度线圈的概念及其特性,然后根据结构和功能对其研究现状进行分类汇总,在此基础上对矩阵线圈未来的发展趋势进行分析.此外,本文还对矩阵梯度线圈的前期研究基础进行了介绍.  相似文献   

18.
When homogenizing the static magnetic field over extended in vivo volumes, significant residual inhomogeneity can remain after spherical harmonic shim optimization. This is due to the low spatial orders of shims available on in vivo MR systems and the presence of higher-order inhomogeneity in the vicinity of anatomic air cavities. Mediation of this problem through the development of higher-order spherical harmonic shims is severely impeded by bore space limitations. Sample-specific passive shims are not limited to low-order spatial compensation and offer an alternative means to increased homogenization. Here, we present a novel construction protocol for sample-specific passive shims comprised of both diamagnetic (bismuth) and paramagnetic (zirconium) materials. A prototype shim is constructed and shown to significantly homogenize the mouse brain at 9.4 T. Further homogenization capabilities are simulated through alteration of the shim construction.  相似文献   

19.
本文详细叙述了超导磁体的磁场分布和匀场线圈的设计。并对匀场电源、匀场线圈的精度和稳定性等要求作了估算。  相似文献   

20.
Low-field nuclear magnetic resonance magnet(2 MHz) is required for rock core analysis. However, due to its low field strength, it is hard to achieve a high uniform B_0 field only by using the passive shimming. Therefore, active shimming is necessarily used to further improve uniformity for Halbach magnet. In this work, an equivalent magnetic dipole method is presented for designing shim coils. The minimization of the coil power dissipation is considered as an optimal object to minimize coil heating effect, and the deviation from the target field is selected as a penalty function term. The lsqnonlin optimization toolbox of MATLAB is used to solve the optimization problem. Eight shim coils are obtained in accordance with the contour of the stream function. We simulate each shim coil by ANSYS Maxwell software to verify the validity of the designed coils. Measurement results of the field distribution of these coils are consistent with those of the target fields.The uniformity of the B_0 field is improved from 114.2 ppm to 26.9 ppm after using these shim coils.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号