首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The detection efficiency of phoswich detector starts to decrease when Compton scattering becomes significant. Events with energy deposit in both scintillators, if not rejected, are not useful for spectral analysis as the full energy of the incident photon cannot be reconstructed with conventional readout. We show that once the system response is carefully calibrated, the full energy of those double deposit events can be reconstructed using a waveform digitizer as the readout. Our experiment suggests that the efficiency of a photopeak at 662 keV can be increased by a factor of 2 using our LaBr3/NaI phoswich detector.  相似文献   

2.
基于硼转换的GEM(Gas Electron Multiplier)探测器性能突出,计数率高达10 MHz以上,耐辐射,信号读出方式简单、灵活,位置与时间分辨率高,是下一代中子束流监测器极具优势的候选者。这种新型中子束流监测器主要由硼中子转换层、气体电离粒子放大的GEM以及二维读出电极组成。通过Geant4程序包对探测器物理过程进行蒙特卡罗(Monte Carlo)模拟,主要研究了硼中子转换层转换效率与厚度及中子波长的关系、出射粒子的能谱、不同气体比分不同气体厚度中的能量沉积、以及γ的能量沉积,计算比较了不同厚度GEM膜对快中子产生的影响。模拟结果表明,出射粒子在漂移区的能量沉积几乎与气体比分无关,硼层厚度取0.1μm以下,漂移区厚度6 mm时,可以确保出射粒子在漂移区能量完全沉积,同时具有最佳n/γ区分能力。  相似文献   

3.
The first application of a pnCCD detector for X‐ray scattering experiments using white synchrotron radiation at BESSY II is presented. A Cd arachidate multilayer was investigated in reflection geometry within the energy range 7 keV < E < 35 keV. At fixed angle of incidence the two‐dimensional diffraction pattern containing several multilayer Bragg peaks and respective diffuse‐resonant Bragg sheets were observed. Since every pixel of the detector is able to determine the energy of every incoming photon with a resolution ΔE/E? 10?2, a three‐dimensional dataset is finally obtained. In order to achieve this energy resolution the detector was operated in the so‐called single‐photon‐counting mode. A full dataset was evaluated taking into account all photons recorded within 105 detector frames at a readout rate of 200 Hz. By representing the data in reciprocal‐space coordinates, it becomes obvious that this experiment with the pnCCD detector provides the same information as that obtained by combining a large number of monochromatic scattering experiments using conventional area detectors.  相似文献   

4.
Charged-particle survival fractions of primary projectile-like fragments from the 40Ar + 197Au reaction at 450 MeV were measured by using a large array of 32 phoswich detectors operating in coincidence with a detector of projectile-like fragments. Differential survival fractions of the primary pickup and stripping reaction products indicate a dependence of the average excitation energy generated in the primary fragments on the direction of the mass transfer.  相似文献   

5.
A new concept for a hybrid structure gaseous detector module with ion backflow suppression for the time projection chamber in a future circular collider is presented.It is a hybrid structure cascaded Gas Electron Multiplier(GEM) with a Micromegas detector.Both Micromegas and GEM have the capability to naturally reduce most of the ions produced in the amplification region.The GEM also acts as the preamplifer device and increases gas gain together with the Micromegas.Feasibility tests of the hybrid detector are performed using an ~(55)Fe X-ray source.The energy resolution is better than 27% for 5.9 keV X-rays.It is demonstrated that a backflow ratio better than 0.2% can be reached in the hybrid readout structure at a gain of 5000.  相似文献   

6.
一维位置灵敏单丝气体探测器采用单根镀金钨丝和200根阴极感应条的探测结构, X射线在阳极丝上产生的信号被多个阴极条感应, 利用重心法得到X射线的原初电离点的位置信息, 位置分辨率达到160 μm(半高全宽). 在同步辐射衍射实验中, X射线通过样品后会形成不同大小的衍射环, 本实验中测量得到11.148°和14.201°的两组衍射角位置信息; 通过平行移动一维探测器在衍射环范围内多次扫描, 可以重建得到二维衍射环. 由于一维探测器的气体厚度和入射窗宽度会给测量结果带来像差, 分析发现像差的影响大于一维探测器的位置分辨. 基于相应的物理分析对测量到的衍射位置进行修正, 修正后的衍射位置相比修正前的衍射位置的相对像差最大改善达到7%, 该方法实现了无像差二维衍射环的重建.  相似文献   

7.
In this work, we characterized an X-ray position sensitive gaseous detector based in a triple stack of gas electron multipliers. The readout circuit is divided in 256 strips for each dimension and using a resistive chain interconnecting the strips, we are able to reconstruct the radiation interaction points by resistive charge division. The detector achieved gains above 104, energy resolution of 15.28% (full width at half maximum) for 5.9 keV X-rays, and position resolution of 1.2 mm, while operating in Ar/CO2(90/10) at atmospheric pressure.  相似文献   

8.
暗物质粒子探测卫星(Dark Matter Particle Explorer,DAMPE)的塑闪阵列探测器(Plastic Scintillator Detector,PSD)需要实现高能e/γ粒子的鉴别功能以及对Z=1~20的宇宙线重离子的电荷测量功能。它使用光电倍增管作为读出器件,并从打拿极5和打拿极8同时引出信号来增大读出动态范围。基于该设计方案的探测单元模块在兰州重离子加速器冷却储存环(HIRFL-CSR)上的外靶终端(ETF)进行了束流测试实验。实验得到了PSD单元条在中能轻核区(Z≤8)的能量响应,并证明了单元条的衰减长度与入射粒子种类无关。通过将实验结果外推至高能重核区,同时结合衰减长度、入射角度和能量涨落等因素,可以估算出PSD探测单元模块输出信号幅度的动态范围。结果显示,该范围在PSD前端电子学模块的线性工作区间内,从而验证了PSD大动态范围读出方案设计的合理性。The Plastic Scintillator Detector (PSD) of DArk Matter Particle Explorer (DAMPE) aims for high energy e/γ identification and charge measurement for cosmic-ray ions from Z=1~20. It adopts photomultiplier tube as the readout device and extracts signals from both dynode5 and dynode8 to enlarge the readout dynamic range. A beam test on a PSD detector unit based this design has been carried out at the External Target Facility (ETF) terminal of the Cooling Storage Ring of Heavy Ion Research Facility in Lanzhou (HIRFL-CSR). The detector response to light nuclei (Z≤8) at the medium energy scale was extracted and the attenuation length was proved to be irrelevant with the impinging nuclei species. By extrapolating the result to heavy nuclei at the high energy scale and taking into account light attenuation, energy fluctuation and imping angle, the dynamic range of the output signal of PSD detector unit was estimated. The range is well within the linear range of the front-end electronics of PSD, thus verifies the large dynamic range readout design of PSD.  相似文献   

9.
新型微结构气体探测器,如气体电子倍增器(gas electron multiplier,GEM)等,具有非常好的位置分辨率潜力(σ100μm),但是需要匹配大规模高密度的读出电子学,给探测器的建设、造价、功耗、空间利用等带来极大压力.阻性阳极读出方法可以在保持较高位置分辨率的前提下,大幅节省电子学.基于厚膜电阻工艺,一种新的阻性单元阵列结构被成功开发和应用于三级级联GEM探测器的读出阳极.该阻性阳极包括6×6个6 mm×6 mm的基本阻性单元,仅需匹配49路读出电子学.~(55)Fe放射源(5.9 keV)和X光机(8 keV)实验的结果显示探测器的位置分辨率(σ)可好于80μm,位置非线性好于1.5%.同时,探测器还获得了很好的实物成像效果.探测器的优良性能表明这种阻性阳极读出方法适用于大面积二维成像气体探测器的读出,并可用于其他探测器的读出.  相似文献   

10.
中国散裂中子源将建设一台基于~3He气体的二维多丝室,作为多功能反射谱仪束线的中子探测器.基于已有的研究,为优化选择二维多丝室探测器的丝结构,本文研究了三种不同的丝结构,并采用重心读出方法和数字读出方法进行了探测器的性能测量,得到了满足多功能反射谱仪探测器需求的读出方法.实验结果表明:对同种丝结构的二维多丝室探测器,重心读出方法的位置分辨和成像性能都好于数字读出方法;基于重心法读出的多丝室探测器位置分辨率可以达到约160μm,基于数字读出方法的多丝室探测器位置分辨率可以达到约400μm.优化设计的丝结构为:基于重心读出法的阳极丝间距1.5 mm、读出通道间距4 mm,基于数字读出法的阳极丝间距1.5 mm、读出通道间距2 mm.优化设计的丝结构均能满足谱仪的位置分辨要求.  相似文献   

11.
窦双团  付利平  贾楠  王天放 《应用光学》2022,43(6):1165-1174
基于微通道板电子倍增电荷分割型阳极的成像探测器常用于行星大气、气辉等微弱信号探测。针对探测器读出电路增益不相等导致探测器成像产生畸变的问题,利用理论分析结合MATLAB仿真揭示了不同畸变图像的形成机制,在该基础上提出了一种探测器读出电路增益补偿方法减小探测器成像畸变。通过MATLAB仿真和实验测试结果表明该文提出的方法能够有效减小由于读出电路增益不相等导致的探测器成像畸变。  相似文献   

12.
气体电子倍增器(GEM)因其具有较好的位置分辨以及各项同性的二维结构等优点,近年来受到了广泛的关注,在HIRFL-CSR上正在建设的低温高密核物质测量谱仪(CEE)也计划使用GEM作为TPC的读出探测器。不同电场条件下GEM探测器的传输特性对探测器的有效增益及能量分辨有较大影响。文中研究了单层GEM探测器中漂移区电场及感应区电场对探测器传输特性的影响;随后研究了双层GEM探测器的电压分配及传输区电场对探测器电荷传输性能的影响。结果表明,在单层及多层GEM探测器中,漂移区电场、传输区电场及感应区电场主要通过改变电子透过率和GEM雪崩电场强度及分布影响探测器的电荷传输性能,进而影响探测器的有效增益及能量分辨。以上实验结果表明GEM探测器是CEE-TPC读出探测器的理想选择,同时测试结果也为TPC中多层级联GEM工作点的选择提供了参考依据。  相似文献   

13.
The thermoluminescent (TLD) method is one of the most commonly used in dose measurements in radiation protection dosimetry. Due to its many advantages this method is widely spread. However, TLD has especially one disadvantage which is very inconvenient: the dose information in already read detectors is erased and in routine standard way the dose can not be reassessed. The positive is that this shortcoming can be eliminated by applying UV radiation. After first readout the same detector can be subjected to UV exposure and then read once again to reassess the dose.This method for reassessment of dose is based on phototransferred thermoluminescence (PTTL). In an irradiated TL detector deep traps are not emptied during the first readout. During exposure to UV, electrons are transferred from deep traps to shallower dosimetric traps. This TL signal emerging during the second readout following UV illumination is called phototransferred thermoluminescence.A method for reassessment of dose in a previously readout TLD is presented in this work. Experiments show that the method works well within region of doses between 5 and 50 mGy, but could be applied for higher doses as well. The efficiency of dose reassessment reaches about 17 percent of the first readout.The method could be a noticeable improvement in TLD dosimetry, giving more opportunities for better control and reliability of measurements.  相似文献   

14.
硬X射线调制望远镜(HXMT)致力于实现硬X射线能段的高灵敏度巡天.HXMT地面样机已在中国科学院高能物理研究所粒子天体物理重点实验室建成.它包括18个栅条准直的NaI(Tl)/CsI(Na)复合晶体探测器,总有效探测面积为5000cm2. 探测器工作在20—250keV,视场范围5.7°×5.7°通过近距离放射源成像实验和直接解调成像方法的使用,地面样机能够达到2'点源定位精度和5'角分辨率(FWHM).  相似文献   

15.
非制冷红外探测器读出电路的非均匀性研究   总被引:1,自引:0,他引:1       下载免费PDF全文
袁红辉  陈永平 《物理学报》2015,64(11):118503-118503
对于长线列的非制冷红外探测器组件, 不同探测元之间的非均匀性是衡量电路设计的关键指标. 为了实现长线列非制冷红外探测器的高性能读出, 本文设计了一种基于电流镜方式的非制冷红外探测器160线列读出电路, 电路由电流镜输入模块、电容负反馈互导放大器模块及相关双采样输出模块组成. 电路采用0.5 μm工艺制作完成. 通过合理设置电路中MOS管的参数和布局电流镜版图, 电路的非均匀性有了明显地改善. 通过测试, 电路的非均匀性小于1%, 器件总功耗约为100 mW, 并具有良好的低噪声特性, 输出噪声小于1 mV, 输出摆幅大于2 V. 该电路与160线列非制冷红外探测器互连后, 能较好地完成红外信号的读出, 在积分时间为20 μups的情况下, 器件的响应为0.294 mV/Ω, 整体性能良好. 该电路的研制对超长线列的非制冷红外冷探测器读出电路研制奠定了重要的技术基础.  相似文献   

16.
HERACLES is a multidetector that has been modified to study heavy-ion collisions, using an ion beam with an energy range between 8 to 15 MeV per nucleon. It has 78 detectors axially distributed around the beam axis in 6 rings allowing detection of multiple charged fragments from nuclear reactions. HERACLES has 4 different types of detectors, BC408/BaF2 phoswich, Si/CsI(Tl) telescope, BC408/BC444 phoswich and CsI(Tl) detectors. 25 Na?+?12 C, 25 Na?+?27 Al, 25 Mg?+?12 C and 25 Mg?+?27 Al reactions have been used to characterize the multidetector. Element identification up to Z = 12 is achieved with the BC408/BaF2 phoswich detectors, up to Z = 15 with the Si/CsI(Tl) telescopes and up to Z = 12 with the BC408/BC444 phoswich detectors. Isotopic identification is reached with the CsI(Tl) detector up to Z = 2.  相似文献   

17.
为了在CSRm的电子冷却器上进行辐射复合以及双电子复合实验, 需要探测能量小于4 MeV/u的离子, 因此设计了新的置于超高真空环境的CsI(Tl)闪烁探测器, 探测器采用的光电倍增管为R7525(Hamamatsu)。 介绍了新闪烁探测器的结构, 并对其进行了性能测试。 测试结果表明, 该探测器对高、 低能离子均有良好的响应, 探测器的信号十分明显。 探测器的最高计数率可以达到106 ions/s, 并且探测器附近的真空度可达10-10 Pa量级, 能够满足辐射复合与双电子复合实验以及储存环对真空的要求, 为今后在CSRm上进行复合实验打下了良好的基础。 A new CsI(Tl) scintillation detector readout with R7525 PMT(Hamamatsu)is designed to detect low energy (<4 MeV/u) ions in radiative recombination and dielectronic recombination experiments at the main cooler storage ring in Lanzhou. The structure of the scintillator detector is described in this paper. The detector is tested with α source and ion beams, respectively. The signals from background, 200 MeV/u C6+ and alpha radioactive source are recorded and analyzed. The results show that the detector has good response to high and low energy ions. The maximum counting rate of the detector can reach 106 ions/s and the vacuum level near the detector can reach 10-10 Pa, both are good for recombination experiments. The installation of the new detector to CSRm is of great help for future radiative recombination and dielectronic recombination experiments.  相似文献   

18.
The first X‐ray photon correlation spectroscopy experiments using the fast single‐photon‐counting detector PILATUS (Paul Scherrer Institut, Switzerland) have been performed. The short readout time of this detector permits access to intensity autocorrelation functions describing dynamics in the millisecond range that are difficult to access with charge‐coupled device detectors with typical readout times of several seconds. Showing no readout noise the PILATUS detector enables measurements of samples that either display fast dynamics or possess only low scattering power with an unprecedented signal‐to‐noise ratio.  相似文献   

19.
A 3 × 6 arrayed charge‐coupled device (CCD) X‐ray detector has been developed for the continuous‐rotation method in macromolecular crystallography at the Photon Factory. The detector has an area of 235.9 mm × 235.9 mm and a readout time of 1.9 s. The detector is made of a 3 × 6 array of identical modules, each module consisting of a fiber‐optic taper (FOT), a CCD sensor and a readout circuit. The outputs from 18 CCDs are read out in parallel and are then digitized by 16‐bit analog‐to‐digital converters. The advantage of this detector over conventional FOT‐coupled CCD detectors is the unique CCD readout scheme (frame transfer) which enables successive X‐ray exposures to be recorded without interruption of the sample crystal rotation. A full data set of a lysozyme crystal was continuously collected within 360 s (180° rotation, 3 s/1.5° frame). The duty‐cycle ratio of the X‐ray exposure to the data collection time was almost 100%. The combination of this detector and synchrotron radiation is well suited to rapid and continuous data collection in macromolecular crystallography.  相似文献   

20.
We demonstrate long-term readout of a binarized image with a dynamic refreshment technique by mutually pumped phase conjugate mirrors (MPPCMs). Long-term continuous readout without any fixing technique can be achieved by the refreshment with image-bearing beam resonance between the phase conjugate mirrors. Our technique additionally offers image binarization by intensity thresholding of MPPCM without any external image processing systems. In this paper, we show grayscale-to-binary conversion as well as long-term readout can be realized by adjusting the appropriate incident beam intensities and the coupling strength of crystals. We perform recording and retrieving experiment with barium titanate crystals and demonstrate the binarized image can be reconstructed over 10 min in the double MPPCM configuration.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号