首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 22 毫秒
1.
An automatic injection system for the analysis of gas phase smoke has been designed and evaluated using the microprocessor-controlled Hewlett-Packard 5830 gas chromatograph. The cryogenic preconcentration trap was constructed from relatively inexpensive and readily available materials. It was determined that the use of the preconcentration trap, as opposed to condensing the smoke on the head of the cold (-50°C) chromatographic column, significantly enhanced the resolution of the more volatile gas phase components. Data are presented which illustrate the injection system characteristics. In addition, chromatograms of gas phase smoke are presented which demonstrate the effectiveness of this technique.  相似文献   

2.
一种测定主流卷烟烟气中固相自由基总量的新方法   总被引:1,自引:0,他引:1  
研究了一种准确测定主流卷烟烟气中固相自由基总量的新方法. 通常人们采用剑桥滤片来捕集主流卷烟烟气中的固相自由基, 但它并不适合用于准确测定主流卷烟烟气中的固相自由基的总量, 研究发现有超过20%的主流卷烟烟气中的固相自由基可以透过剑桥滤片. 找到了一种电子顺磁共振波谱(EPR)信号很小的、适合用来捕集主流卷烟烟气中的固相自由基总量的过滤片. 采用了以在相同条件下测得的1,1-二苯基-2-苦基肼基(1,1-Diphenyl-2-picryl-hydrazyl, 简称DPPH)的EPR信号强度与强煤的EPR信号强度相比得到的相对EPR信号强度与自由基的自旋数建立校准曲线的方法来计算烟气固相自由基的量, 降低了使用不同的电子自旋共振波谱仪造成的对同一种检测样品测定结果的差异. 通过不同实验室内和实验室间的验证实验, 证明了此方法有很好的重复性和重现性.  相似文献   

3.
Complex smoke profiles from fused silica capillary gas chromatography of different cigarette types produce rich information requiring computer and sophisticated statistical analysis to reveal the hidden correlation patterns. In our technique, a Cambridge pad containing total particulate matter (TPM) is extracted with Freon-11 in a micro-Soxhlet apparatus. The condenser is maintained at ?15°C. After extraction, Freon-11 is allowed to evaporate under mild conditions. Bis(trimethylsilyl)trifuoroacetamide (BSTFA) is subsequently added to the extract. Trimethylsilylation is completed by maintaining the reaction vessel at 60°C for two hours. A microprocessor-controlled capillary gas chromatograph with an automatic sampler is used to generate profiles. A link to a host computer provides for transmission of profile reports and access to various statistical and graphic packages. Factor and discriminant analyses are applied to gas chromatographic data from TPM extracts because of their ability in data reduction, pattern extraction and ranking the importance of the gas chromatographic peaks. Some preliminary results from these statistical analyses are discussed.  相似文献   

4.
Fan  Zhong  Chen  Zhiyan  Tian  Zhaofu  Zhou  Yun  Xu  Aifei  Meng  Dongling  Huang  Shijie  Liu  Huimin  Li  Xiaolan 《Chromatographia》2014,77(21):1563-1568

Vinyl chloride (VC) in the vapor phase of mainstream cigarette smoke was determined under both International Organization for Standardization (ISO) and Health Canada intensive (HCI) machine smoking regimens, which was suspected to be carcinogenic compound. VC was collected by passing the mainstream cigarette smoke through a Cambridge Filter Pad (CFP) into cryogenic traps containing methanol. The impinger solutions were fortified with VC-d 3 and analyzed by GC–MS. Limits of detection for vinyl chloride was 0.9 ng mL−1 with the recovery in the range of 93.2–98.4 %. Moreover, the intra-day and inter-day precision was 7.39 and 9.77 %, respectively. Under HCI machine smoking regimen, the vinyl chloride yields in vapor phase of mainstream cigarette smoke were much higher and the average increase was greater than 100 % compared with those under ISO smoking condition.

  相似文献   

5.
建立了在线液相-气相二维色谱测定卷烟主流烟气中4-(N-甲基亚硝胺基)-1-(3-吡啶基)-1-丁酮(NNK)的方法。 NNK 的分析在在线凝胶气质联用仪上进行,采用自行装填的微型碱性氧化铝柱,并把仪器上的凝胶柱换成氧化铝柱,用于 NNK 的分析。捕集有主流烟气总粒相物的剑桥滤片用二氯甲烷提取,以 D4-NNK 为内标,提取液经微型氧化铝柱分离,含 NNK 的部位切割进入气相色谱,排干溶剂后启动气相色谱升温经毛细管柱进行分离,用质谱检测。本方法将烟气国标方法 NNK 测定中的氧化铝柱色谱净化和气相色谱-质谱分析在线连接起来,可不经样品前处理净化直接进样分析;每次进样可达40μL,是常规气相色谱-质谱分析最大进样量(2.0μL)的20倍,显著提高了分析灵敏度。方法线性范围达1.2~120 ng/ mL,相关系数为r=0.9998,回收率为93.9%~96.0%;检出限和定量限分别为0.25 ng/ mL 和0.9 ng/ mL,样品分析结果与中国烟草总公司企业标准方法进行对比,结果相符合。  相似文献   

6.
Bian Z  Tang G  Chen Z  Pang Y  Jiang X  Hu Q 《色谱》2011,29(10):1031-1035
以全自动固相萃取技术净化主流烟气萃取液,建立了卷烟主流烟气中苯并[a]芘、苯并[a]蒽和屈艹 3种多环芳烃的气相色谱-串联质谱(GC-MS/MS)测定方法。以吸烟机抽吸卷烟,并以剑桥滤片捕集卷烟主流烟气,然后以含氘代苯并[a]芘内标的环己烷溶液萃取滤片,萃取液经全自动固相萃取仪净化后以GC-MS/MS分离检测。结果表明,苯并[a]芘、苯并[a]蒽和屈艹 的检出限分别为0.05、0.16和0.23 ng/cig,回收率为91.5%~102.1%,相对标准偏差(RSD)均小于5%。该方法的自动化程度高、操作简便、检出限低、重复性好,适用于卷烟主流烟气中苯并[a]芘、苯并[a]蒽 3种多环芳烃释放量的检测。  相似文献   

7.
烟气中有机酸的分析   总被引:10,自引:0,他引:10  
陈章玉  罗莉丽  武怡  曾晓鹰 《色谱》2001,19(4):374-377
 应用甲酯衍生化试剂对卷烟烟气粒相物中有机酸进行甲酯衍生化 ,经固相微萃取 (SPME)后通过气 质联用仪分离鉴定。分析了 4个品牌的卷烟烟气 ,共鉴定了 60多种挥发及半挥发性有机酸。对丁酸、己酸、糠酸、辛酸、壬酸、苯甲酸、苯乙酸、十四酸、十六酸进行了定量分析。该方法用于烟气中有机酸的定性、定量分析 ,灵敏度较高 ,快速简便。  相似文献   

8.
Vinyl chloride (VC) in the vapor phase of mainstream cigarette smoke was determined under both International Organization for Standardization (ISO) and Health Canada intensive (HCI) machine smoking regimens, which was suspected to be carcinogenic compound. VC was collected by passing the mainstream cigarette smoke through a Cambridge Filter Pad (CFP) into cryogenic traps containing methanol. The impinger solutions were fortified with VC-d 3 and analyzed by GC–MS. Limits of detection for vinyl chloride was 0.9 ng mL?1 with the recovery in the range of 93.2–98.4 %. Moreover, the intra-day and inter-day precision was 7.39 and 9.77 %, respectively. Under HCI machine smoking regimen, the vinyl chloride yields in vapor phase of mainstream cigarette smoke were much higher and the average increase was greater than 100 % compared with those under ISO smoking condition.  相似文献   

9.

To reduce the smoke release of poly(vinyl chloride) (PVC) during burning, layered double hydroxides (LDHs) and zinc oxide (ZnO) powders were used to modify the polymer. The results indicated that the addition of LDHs‐ZnO had a significant effect on smoke suppression. The limiting oxygen index (LOI) reached a maximum value and the smoke density rank (SDR) exhibited a minimum value when the weight percentages of LDHs and ZnO in PVC were 3% and 2%, respectively. Thermal stabilities of the modified PVC and degradation products were investigated by means of thermogravimetry and pyrolysis‐gas chromatography‐mass spectra (Py‐GC‐MS). The LDHs‐ZnO obviously accelerated the decomposition of PVC to release hydrogen chloride, and the decomposed PVC consequently produced the trans‐conjugated polyene sequences, which easily formed crosslinked structures. However, a cyclization reaction in PVC chain without the additives produced aromatic compounds such as benzene, toluene, and naphthalene at 350°C. Even though, an amount of aromatic compounds was released from the PVC modified with LDHs‐ZnO at the temperature of 600°C, the content of the decomposed products is relatively lower compared to unmodified PVC.  相似文献   

10.
A simple and accurate method, gas chromatography (GC) with flame-ionization detection (FID) has been used for determination of the four main nicotine-related alkaloids in tobacco. Tobacco samples were treated with a small quantity of aqueous ammonia solution, to loosen the tobacco tissue and to convert all alkaloids to free bases, then extracted with 1:3 CH3OH-CH2Cl2. A method for further simultaneous and comprehensive determination of six nicotine-related alkaloids in cigarette smoke was also developed. Because of the complexity of the cigarette smoke matrix and the small amounts of alkaloids, except nicotine, in cigarette smoke, the smoke extract was concentrated after removal of the acidic and neutral fractions. To reduce the adsorption and thermal degradation of alkaloids in the liner, especially for nornicotine, a suitable injector temperature was selected and pulsed injection mode was studied. Different cigarette smokes and tobaccos were analyzed for levels of nicotine-related alkaloids.Revised: 3 January and 21 March 2005  相似文献   

11.
气相色谱/质谱法测定卷烟烟气中的主要挥发酸   总被引:7,自引:0,他引:7  
以异丙醇为溶剂,壬醇为内标,采用气相色谱/质谱法定性定量分析了卷烟烟气中的游离态甲酸和乙酸,还测定了该方法的精密度和准确度,结果为:RSD小于2%,回收率大于97%.  相似文献   

12.
A method is described for the simultaneous analysis of hydrogen sulfide, carbonyl sulfide, methanethiol, carbon disulfide, methyl thiocyanate and methyl disulfide in mainstream vapor phase (MVP) cigarette smoke by gas chromatography–mass spectrometry. The fresh MVP smoke was collected in a gas bag, followed by injection of a 50 μL gas sample into the GC inlet via an automatic six-port valve. The separation was on a CP-PoraPLOT Q column and MS was operated in SIM mode. It was found that while carbonyl sulfide and carbon disulfide are very stable in the gas bag, hydrogen sulfide, methanethiol, methyl disulfide and methyl thiocyanate are extremely reactive and their levels increase or decrease drastically with the storage time in the gas bag. These results suggest that there is an absolute need to analyze the smoke sample as quickly as possible. Maintaining a precise time after the smoke collection is a key factor in order to obtain reproducible results. In this study, all the samples are injected within 2 min after MVP smoke was collected in the bag. Under smoke conditions of 60 mL puff of 2 s duration every 30 s, 12 brands of commercial cigarettes and Kentucky Reference 2R4F cigarettes were analyzed. Average values of three replicates of the 2R4F cigarettes were 31.6 μg cigt?1 hydrogen sulfide, 40.7 μg cigt?1 carbonyl sulfide, 25.6 μg cigt?1 methanethiol, 2.2 μg cigt?1 carbon disulfide, 23.7 μg cigt?1 methyl thiocyanate and 17.6 μg cigt?1 methyl disulfide. All other types of analyzed cigarettes show a similar quantitative distribution for these analytes.  相似文献   

13.
Tobacco‐specific N‐nitrosamines are carcinogenic components in mainstream cigarette smoke. To explore tobacco‐specific N‐nitrosamine release levels in cigarettes, a magnetic solid‐phase extraction procedure using magnetic graphene composite as sorbent for fast enrichment of tobacco‐specific N‐nitrosamine was developed. Under optimal conditions, a tobacco‐specific N‐nitrosamine determination method was successfully proposed by combining magnetic solid‐phase extraction procedure and high‐performance liquid chromatography coupled with tandem mass spectrometry. The method's limit of detection for tobacco‐specific N‐nitrosamines in mainstream cigarette smoke ranged from 0.018 to 0.057 ng/cigarette. Good linearities were obtained with correlation coefficients above 0.9992. The accuracies of tobacco‐specific N‐nitrosamines in a spiked mainstream cigarette smoke sample were from 89.3 to 109.4%, with a relative standard deviation of less than 11.2%. The proposed method has the merits of rapidity and high sensitivity. Finally, the method was successfully applied to tobacco‐specific N‐nitrosamine analysis in real samples.  相似文献   

14.
《Analytical letters》2012,45(11):751-759
Abstract

The use of gas chromatography with flame photometric detection provides a convenient means of detecting sulfur-containing compounds in the gas phase of cigarette smoke. Application of the method casts doubt on currently held views about the composition of the sulfur-containing portion of smokes.  相似文献   

15.
以芘(PYR)为模板,由热引发本体聚合合成了芘分子印迹聚合物(MIP),考察了印迹聚合物的选择性吸附性能,采用Scatchard模型分析了印迹聚合物的结合特性,用离线固相萃取实验考察了印迹聚合物对同类底物的吸附能力,并将芘分子印迹聚合物应用到卷烟滤嘴中,用GC/MS法考察了卷烟主流烟气中稠环芳烃类物质释放量的变化。 结果表明,芘分子印迹聚合物具有选择性降低卷烟烟气中稠环芳烃类物质的功能,当MIP添加量为1.5 mg时,能将卷烟烟气中的苯并[a]芘(B[a]P)、苯并(a)蒽(B[a]A)和苣(CHR)的释放量分别降低31.08%、25.69%和27.33%。  相似文献   

16.
Advanced smoke generation systems, such as the Borgwaldt RM20S® smoking machine used in combination with the BAT exposure chamber, allow for the generation, dilution and delivery of fresh cigarette smoke to cell or tissue cultures for in vitro cell culture analyses. Recently, our group confirmed that the Borgwaldt RM20S® is a reliable tool to generate and deliver repeatable and reproducible exposure concentrations of whole smoke to in vitro cultures [1]. However, the relationship between dose and diluted smoke components found within the exposure chamber has not been characterized. The current study focused on the development of a headspace stir bar sorptive extraction (HSSE) method to chemically characterize some of the vapor phase components of cigarette smoke generated by the Borgwaldt RM20S® and collected within a cell culture exposure chamber. The method was based on passive sampling within the chamber by HSSE using a Twister™ stir bar. Following exposure, sorbed analytes were recovered using a thermal desorption unit and a cooled injection system coupled to gas chromatograph/mass spectrometry for identification and quantification. Using the HSSE method, sixteen compounds were identified. The desorption parameters were assessed using ten reference compounds and the following conditions led to the maximal response: desorption temperature of 200 °C for 2 min with cryofocussing temperature of −75 °C. During transfer of the stir bars to the thermal desorption system, significant losses of analytes were observed as a function of time; therefore, the exposure-to-desorption time interval was kept at the minimum of 10 ± 0.5 min. Repeatability of the HSSE method was assessed by monitoring five reference compounds present in the vapor phase (10.1–12.9% RSD) and n-butyl acetate, the internal standard (18.5% RSD). The smoke dilution precision was found to be 17.2, 6.2 and 11.7% RSD for exposure concentrations of 1, 2 and 5% (v/v) cigarette vapor phase in air, respectively. A linear response of analyte abundance was observed as a function of dilution. Extrapolation to 100% (v/v) cigarette vapor phase, i.e., undiluted smoke, gave yields for the five compounds ranging from 6 to 450 ng for 10 min exposure.  相似文献   

17.
建立了超高效液相色谱(UPLC)对卷烟主流烟气总粒相物中甲醛、乙醛、丙酮、巴豆醛等8种羰基化合物的测定方法。采用经2,4-二硝基苯肼酸性溶液处理过的剑桥滤片捕集烟气,再用含2%(体积分数)吡啶的乙腈溶液进行萃取,以KinetexTM C18(150 mm×2.1 mm,2.6 μm)为色谱柱,水-乙腈(35∶65)和水-乙腈-四氢呋喃-异丙醇(59∶30∶10∶1)为流动相梯度洗脱,采用二极管阵列检测器进行检测,分析时间为20 min。结果表明,该方法的相关系数r2≥0.999 97,检出限为25.81~67.74 ng/cig,平均加标回收率为95%~99%,相对标准偏差为1.4%~5.8%。各组分峰分离度高、分析时间短、流动相耗量少、结果准确可靠。用该方法对20种不同卷烟牌号样品中8种羰基化合物的含量进行测定,结果满意。  相似文献   

18.
《Analytical letters》2012,45(3):751-763
Abstract

A new method for the analysis of selected components in complex gas mixtures has been developed utilizing a relatively inexpensive Fourier transform infrared spectrometer and a continuous flow gas cell. the method was used to monitor nitric oxide and nitrogen dioxide concentrations in cigarette smoke with time.

Using multivariate least-square regression analysis, it is possible to simultaneously quantitate both NO and NO2, even in the presence of overlapping peaks. Using this method, the oxidation of nitric oxide in the presence of isoprene in cigarette smoke and in a model system was followed with time. the method also can be applied to other compounds in smoke or to any other gaseous mixture.  相似文献   

19.
The main aim of this study was to present the effects of barbecue smoke on a small-scale environment, a national park under the influence of intense barbecue smoke, and to scientifically support the sustainable usage of the park. Twelve-weekly bulk deposition samples were collected directly at the barbecuing area, and the samples were analysed for 16 US EPA’s priority PAH compounds and major ions. The mean concentrations of the individual PAHs in the bulk deposition samples ranged from 11.8 ng L?1 (Ane) to 1085 ± 581 ng L?1 (IcdP). The most frequently observed PAH compounds in the bulk deposition samples were Np, Anp, Flr, Phe, An, Flu, BkF, BaP and IcdP. The mean total PAH deposition fluxes were determined as 3.6 ± 5.6 µg m?2 day?1. The chloride, potassium and the sulphate fluxes were determined as 145.2 ± 267.8 µg m?2 day?1, 182.9 ± 291.9 µg m?2 day?1, and 111.9 ± 65.9 µg m?2 day?1, respectively. Dominant ions in the bulk deposition samples were potassium ion, chloride and sulphate which addressed as the fingerprint of barbecue grilling.  相似文献   

20.
Although nitrogen dioxide (NO(2)) has been previously reported to be present in cigarette smoke, the concentration estimates were derived from kinetic calculations or from measurements of aged smoke, where NO(2) was formed some time after the puff was taken. The objective of this work was to use tunable infrared laser differential absorption spectroscopy (TILDAS) equipped with a quantum cascade (QC) laser to determine if NO(2) could be detected and quantified in a fresh puff of cigarette smoke. A temporal resolution of approximately 0.16s allowed measurements to be taken directly as the NO(2) was formed during the puff. Sidestream cigarette smoke was sampled to determine if NO(2) could be detected using TILDAS. Experiments were conducted using 2R4F Kentucky Reference cigarettes with and without a Cambridge filter pad. NO(2) was detected only in the lighting puff of whole mainstream smoke (without a Cambridge filter pad), with no NO(2) detected in the subsequent puffs. The measurement precision was approximately 1.0 ppbVHz(-1/2), which allows a detection limit of approximately 0.2 ng in a 35 ml puff volume. More NO(2) was generated in the lighting puff using a match or blue flame lighter (29+/-21 ng) than when using an electric lighter (9+/-3 ng). In the presence of a Cambridge filter pad, NO(2) was observed in the gas phase mainstream smoke for every puff (total of 200+/-30 ng/cigarette) and is most likely due to smoke chemistry taking place on the Cambridge filter pad during the smoke collection process. Nitrogen dioxide was observed continuously in the sidestream smoke starting with the lighting puff.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号