首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 187 毫秒
1.
徐琴  刘妮娜  朱俊杰 《中国化学》2005,23(11):1510-1514
A composite material of nitric acid oxidized multiwalled carbon nanotube (MWNT) and Nation was prepared. Such composite was modified on a glassy carbon electrode to determine trace of lead by differential pulsed voltammetry. In pH=6.47 NaNO3 solution, Pb^2+ ions were accumulated on the modified electrode at -0.4 V. Compared with a bare and a Nation film coated electrode, the composite coated GC electrode can reduce the accumulating potential and eliminate the toxic character of mercury. The calibration plots were linear at low concentration of 5.0× 10^-9-2.0× 10^-8 mol/L and high concentration of 2.5× 10^-8-5.0× 10^-6 mol/L. The performances characteristics indicate that the electrode can be used to determine trace Pb^2+ ions.  相似文献   

2.
Silver (Ag) nanoparticles were directly electrodeposited on multi-walled carbon nanotubes (MWCNT) in AgNO3/LiNO3 containing EDTA (ethylenediaminetetraacetic acid). The structure and nature of the resulting Ag/MWNT composite were characterized by field emission scanning electron microscopy (FE-SEM), transmission electron microscopy (TEM) and X-ray diffraction (XRD), and the distribution shape of Ag nanoparticles was found to be dependent on the presence of EDTA. The modified electrode showed excellent electrocatalytic activity to redox reaction of hydrogen peroxide and the mechanism of hydrogen peroxide was partly reversible procession with oxidation and reduction peaks at 0.77 and -0.83 V, respectively. The oxidation and reduction peak currents were linearly related to hydrogen peroxide concentration in the range of 1×10^-6-3×10^-4 and 1 ×10^-8-7× 10^-4 mol·L^-1 with correlation coefficients of 0.996 and 0.986, and 3s-detection limit of 9 × 10^-7 and 7 × 10^-9 mol·L^-1.  相似文献   

3.
A novel type of carboxylated multiwalled carbon nanotube modified electrode(c-MWCNTs/GCE) was constructed and the electrochemical properties of phenacetin(PHE) at it were studied. In a buffer solution of 0.1 mol/L HAc-NaAc(pH=5.3), PHE exhibited a couple of quasi-reversible redox peaks and an anodic peak in the poten- tial range of 0.2--1.2 V at c-MWCNTs/GCE. The peak current was proportional to the concentration of PHE in the range of 4.0× 10^-6_ 1.0 × 10^-4 mol/L with a detection limit of 1.0× 10^-6 mol/L(S/N=3). The c-MWCNTs/GCE showed excellent repeatability and stability and the electrochemical reaction mechanism of PHE was proposed. This method was used to determine the content of PHE in medical tablets and the recovery was determined to be 96.5%--104.2% by means of a standard addition method.  相似文献   

4.
Celestine blue(CB)was introduced as a new electroactive indicator in DNA biosensors.The interaction of CB with DNA was investigated by electrochemical and spectroscopic methods.The effect of buffer kind and p H on the electrochemical behavior of CB was studied.The peak currents of CB were linearly related to DNA concentration in the range of 5.0×10~(-9) to 1.0×10~(-7)mol/L.The detection limit of this approach was 4.76×10~(-10) mol/L.Based on spectrometry data a hypochromic effect was observed in UV-Vis spectra of CB with increasing DNA concentration.The results illustrate the possible interaction mode between CB and DNA is electrostatic binding.  相似文献   

5.
Gold nanoclusters(AuNCs) were prepared in the presence of the nucleobases of poly-cytosine DNAs in this paper. We have demonstrated tliat the fluorescence of the AuNCs is quenched by thiocyanate(SCN^-) through the interaction between SCN^- and gold atoms. AuNCs can receive energy from nucleobases to boost their emission intensity, while in the presence of SCN^-, they coordinate with Au atoms and influence the energy transfer between the nucleobases and AuNCs, leading to the fluorescence quenching. The decreased fluorescence intensity was in proportion to the concentration of SCN^- in the range of 8.0×10^-7-1.5×10^-5 mol/L with a limit of detection of 4.2×10^-7 mol/L(3σ). We further validated the practice of this probe througli the detection of SCbT in natural water samples.  相似文献   

6.
A simple spectrophotometric assay of H2O2 and glucose using Ag nanoparticles has been carried out. Relying on the synergistic effect of H2O2 reduction and ultraviolet (UV) irradiation, Ag nanoparticles with enhanced absorption signals were synthesized. H2O2 served as a reducing agent in the Ag nanoparticles formation in which Ag+ was reduced to Ago by O2- generated via the decomposition of H2O2 in alkaline media. On the other hand, photoreduction of Ag+ to Ago under UV irradiations also contributed to the nanoparticles formation. The synthesized nanoparticles were characterized by TEM, XPS, and XRD. The proposed method could determine H2O2 with concentrations ranging from 5.0× 10^-7 to 6.0× 10^-5 tool/ L The detection limit was estimated to be 2.0 × 10^-7 mol/L. Since the conversion of glucose to gluconic acid catalyzed by glucose oxidase was companied with the formation of H2O2, the sensing protocol has been successfully utilized for the determination of glucose in human blood samples. The results were in good agreement with those determined by a local hospital. This colorimetric sensor thus holds great promises in clinical applications.  相似文献   

7.
A carbon paste electrode modified with electropolymerized fills of isonicotinic acid was developed.The modified electrode shows excellent electrocatalytic activity toward the oxidation of both dopamine(DA)and epinephrine(EP).Separation of the reduction peak potentials for dopamine and epinephrine was about 357 mV in pH 5.3 phosphate buffer solution(PBS)and the character was used for the detection DA and EP simultaneously.The peak currents increase linearly with DA and EP concentration over the range of 8.0×10-5 to 7.0×10-4 mol/L and 5.0×10-6 to 1.0×10-4 mol/L with detection limits of 2 × 10-5 and 1×10-6 mol/L,respectively.The interference studies showed that the modified electrode exhibits excellent selectivity in the presence of large excess of ascorbic acid(AA).  相似文献   

8.
A novel method for the determination of two quinolone drugs norfloxacin (NOR) and levofloxacin (LVX) was described by capillary electrophoresis with electrochemiluminescence detection. The good relationship (r ≥ 0.9991) between peak area and concentration of analytes was established over two orders of magnitude. The limits of detection (LOD, S/N = 3) in standard solution are 4.8 × 10^-7 mol/L for NOR and 6.4 × 10^-7 mol/L for LVX, respectively. The limits of quantitation (LOQ, S/N = 10) in real human urine samples are 1.2 × 10^-6 mol/L for NOR and 1.4 × 10^-6 mol/L for LVX, respectively. The present method was successfully applied to the determination of NOR and LVX in human urine and the studv of oharmacokinetics of NOR.  相似文献   

9.
Based on the micelle synergism mechanism, a chemiluminescence (CL) flow system for the determination of sulfite was described. The CL signal generated from the reaction of chlorate with sulfite in acidic solution was very weak, while the interfusion of sodium dodecylbenzenesulfonate (SDBS) resulted in a highly chemiluminescent intensity. The major goal of this work was to investigate and develop the SDBS rnicelle synergetic CL system. The mechanism was proposed and proved by spectrometry. The results indicated that the unique structure of SDBS micelles prorooted the aggregation of rhodamine 6G (Rh6G) and a much easier energy transfer, leading to a marked shift to red in the CL emission. This CL system was developed for the determination of sulfite and the concentration of sulfite was proportional to the CL intensity in the range of 5.0× 10^-8--1.0× 10^-5 mol/L with the detection limit of 1.7×10^-8 mol/L (S/N=3). The relative standard deviation was 3.3% for 1.0×10^ 6 mol/L sulfite solution with eleven repeated measurements. This method was successfully applied to the determination of sulfite in powder sugar.  相似文献   

10.
Using the whole cell patch-clamp technique,we studied the effects of La3+ on calcium-activated K+ currents and its kinetics of activation and inactivation in non-excitable MC3T3 cells.Our results showed that the calcium-activated outward K+ currents were promoted with increasing concentration of Ca2+ in the pipette solution and a voltage- and Ca2+-dependent manner.La3+ in the bath solution inhibited the currents in a concentration-dependent manner and the inhibition EC50 was 8.23 ± 1.45 μmol/L.At the concentration of 50 μmol/L,La3+ significantly changed the Vh of the activation curve and shifted the activation curve to more positive potentials,but shifted the inactivation curve to more negative potentials.It had no effect on the slope factor k of the activation and inactivation curves.Potassium currents inhibition could induce a series of physiological and molecular biological functions,presumably because of its ability to depolarize the plasma membrane and enhance cell excitability,resulting in increasing Ca2+ influx and cytoplast Ca2+ concentration.This process may be one of the molecular mechanisms by which La3+ affects the cell growth and function of MC3T3 cells.  相似文献   

11.
Yulong Gao  Tao Wang  Fengyu Liu 《中国化学》2016,34(12):1297-1303
The electrochemiluminescence (ECL) of the Ru(phen)32+/thymine (T) system at bare and graphene oxide (GO)‐modified glassy carbon (GC) electrodes was utilized to determine Hg2+ in tap water. The ECL intensity of Ru(phen)32+ was considerably enhanced by the addition of thymine because of the occurrence of ECL reaction between them. Subsequently, the ECL intensity of Ru(phen)32+/T system rapidly decreased with the addition of Hg2+ because of the formation of a T‐Hg2+‐T complex. A linear response (R2=0.9914) was obtained over a Hg2+ concentration range of 1.0×10?9 mol/L to 1.0×10?5 mol/L with a detection limit of 3.4×10?10 mol/L at a bare GC electrode in 0.1 mol/L phosphate buffer (pH=8.0). The detection limit can be further reduced to 4.2×10?12 mol/L after modification of the GC electrode by GO. To verify its applicability, the proposed method was utilized to determine Hg2+ in tap water and simulated wastewater. The method exhibited good reproducibility and stability and thus reveals the possibility of developing a novel ECL detection method for Hg2+.  相似文献   

12.
Based on single‐walled carbon nanotubes (SWCNTs) modified glassy carbon electrode (GCE/SWCNTs), a novel method was presented for the determination of L ‐tyrosine. The GCE/SWCNTs exhibited remarkable catalytic and enhanced effects on the oxidation of L ‐tyrosine. In 0.10 mol/L citric acid‐sodium citrate buffer solution, the oxidation potential of L ‐tyrosine shifted negatively from +1.23 V at bare GCE to +0.76 V at GCE/SWCNTs. Under the optimized experimental conditions, the linear range of the modified electrode to the concentration of L ‐tyrosine was 5.0×10?6–2.0×10?5 mol/L (R1=0.9952) and 2.7×10?5–2.6×10?4 mol/L (R2=0.9998) with a detection limit of 9.3×10?8 mol/L. The kinetic parameters such as α (charge transfer coefficient) and D (diffusion coefficient) were evaluated to be 0.66, 9.82×10?5 cm2 s?1, respectively. And the electrochemical mechanism of L ‐tyrosine was also discussed.  相似文献   

13.
Novel Zn2+ ion‐selective PVC based coated graphite electrodes were fabricated using the ionophores N‐((1H‐indol‐3‐yl)methylene)thiazol‐2‐amine (I1), N‐((1H‐indol‐3‐yl)methyl)‐thiazol‐2‐amine (I2) and 1‐((1H‐indol‐3‐yl)methylene)urea (I3). Their potentiometric performance was examined in dependence of the addition of plasticizers and anion excluders and compared. It is found that the coated graphite electrode with the composition I1:KTpClPB:o‐NPOE:PVC=9 : 1.5 : 51 : 38.5 is the best with respect to the wide working concentration range (4.2×10?8–1.0×10?1 mol L?1), low detection limit (1.6×10?8 mol L?1) and wide pH range of 3.0–8.0. The proposed electrode was successfully applied to quantify Zn2+ in various environmental, biological and medicinal plant samples and used as indicator electrode.  相似文献   

14.
Measurements of the NO-catalyzed dissociation of I2 in Ar in incident shock waves were carried out in the temperature range of 700°-1520°K and at total concentrations of 5 × 10?6-6 × 10?5 mol/cm3, using ultraviolet-visible absorption techniques to monitor the disappearance of I2. It was shown that the main reaction responsible for the disappearance under these conditions is I2 + NO → INO + I, for which a rate coefficient of (2.9 ± 0.5) × 1013 exp[-(18.0 ± 0.6 kcal/mol)/RT] cm2/mol·sec was determined. The INO formed dissociates rapidly in a subsequent reaction. The reaction, therefore, constitutes a “chemical model” for a “thermal collisional release mechanism.” Preliminary measurements of the rate coefficient for I2 + NO2 → INO2 + I are also presented. Combined with information on the reverse reactions obtained in earlier room temperature experiments, these results lead to accurate values of ΔH°f for INO and INO2 equal to 29.7 ± 0.5 and 15.9 ± 1 kcal/mol, respectively.  相似文献   

15.
A novel chemiluminescence (CL) method for the determination of hydrogen peroxide is described. Method is based on the transition metals in highest oxidation state complex, which include diperiodatoargentate (DPA) and diperiodatonickelate (DPN) and show excellent sensitisation on the luminol-H2O2 CL reaction with low luminol concentration in alkaline medium. In particular, the sensitiser which was previously reported (such as Co2+, Cu2+, Ni2+, Mn2+, Fe3+, Cr3+, KIO4, K3Fe(CN)6 etc.) to be unobserved CL due to poor sensitisation with such low concentration of luminol which makes the method hold high selectivity. Based on this observation, the detection limits were 6.5?×?10?9?mol?L?1 and 1.1?×?10?8?mol?L?1 hydrogen peroxide for the DPN- and DPA-luminol CL systems, respectively. The relative CL intensity was linear with the hydrogen peroxide concentration in the range of 2.0?×?10?8–6.0?×?10?6?mol?L?1 and 4.0?×?10?8–4.0?×?10?6?mol?L?1 for the DPN- and DPA-luminol CL systems, respectively. The proposed method had good reproducibility with a relative standard deviation of 3.4% (8.0?×?10?7?mol?L?1, n?=?7) and 1.0% (2.0?×?10?6?mol?L?1, n?=?7) for the DPN- and DPA-luminol CL systems, respectively. A satisfactory result has been gained for the determination of H2O2 in rainwater and artificial lake water by use of the proposed method.  相似文献   

16.
本文用荧光光谱法研究了皖南尖吻蝮蛇毒糖苷水解酶(NADase)的性质。在pH<6时,pH对NADase的荧光强度影响较大,而在pH>6,pH对NADase的荧光强度几乎没有什么影响,Cu2+的加入可引起NADase的内源荧光强度的降低,通过荧光滴定测得Cu2+与NADase结合常数KEM为5.3×103(mol/L)-1。I-对NADase发光的淬灭作用很小,I  相似文献   

17.
《Electroanalysis》2017,29(2):441-447
A convenient and simple electrochemiluminescence (ECL) method was employed to detect trace amounts of Cu2+ in drinking water. This method is based on the inhibitory effect of Cu2+ on the ECL of Ru(phen)32+ and 1,4,8,11‐tetraazacyclotetradecane (cyclam) system. ECL intensity of Ru(phen)32+ was considerably enhanced by the addition of cyclam because of the ECL reaction between them. The ECL intensity of Ru(phen)32+/cyclam system rapidy decreased with the addition Cu2+ because of the formation of chelate complex [Cu(cyclam)]2+. Good linear response (R 2=0.9948) was obtained at Cu2+ concentration of 1.0×10−9−1.0×10−5 mol ⋅ L−1 at glassy carbon electrode in 0.1 mol ⋅ L−1 phosphate buffer (pH 9.0). Observed detection limit of 4.8×10−10 mol ⋅ L−1 satisfied the maximum contaminant level goal (MCLG) for Cu2+ set by the US Environmental Protection Agency (US EPA). Applicability of the proposed method was verified by the good reproducibility and stability of the method when applied to determine Cu2+ in tap water and simulated wastewater. Thus, a novel ECL detection method was developed for Cu2+ detection.  相似文献   

18.
《Analytical letters》2012,45(15):2673-2682
Abstract

A new heteronuclear complex, rare earth (III)-copper (II)-m-trifluomethyl chlorophosphonazo (CPA-mCF3) system for determining trace rare earth ions is presented. In a medium of 0.02mol/L NH4Cl,1. 0×10?3mol/L Cu(II),1.0×10?5 mol/L CPA-mCF3, a very sensitive polarographic adsorptive wave is observed by using a single sweep oscillopolarograph at about –0.83V (vs. Ag/AgCl). The linear relationship between the peak current and the concentration of rare earth exists from 6. 0×10?9 to 1. 0×10?6 mol/L. The detection limit of rare earth is down to 2. 0×10?9 mol/L for Tm3+. This method has been applied to determine trace RE in several samples of Chinese tea. The results are satisfactory. The composition of the complex is detected as RE (II): Cu (II): CPA-mCF3 = 1: 1: 2.  相似文献   

19.
In this paper, a pre‐anodized inlaying ultrathin carbon paste electrode (PAIUCPE) with 316L as a matrix was constructed by a simple and fast electrochemical pretreatment. Using xanthine (Xa) and hypoxanthine (HXa) as the target compounds, the pH effects compositions of buffer solution, the accumulation times, hydrogen bond catalysis, degree of auxiliary electrode reaction on the size of peak currents (Ip) of Xa and HXa was discussed in detail. Also, it was proposed that Xa and HXa were respectively absorbed at the surface of PAIUCPE through hydrogen bonding. The influencing mechanisms of the PAIUCEP on electrochemical oxidation of Xa and HXa were explained in detail. Moreover, the linear relationships for the Xa and HXa were obtained in the range of 6×10?8–3×10?5 mol/L and 2×10?7–7×10?5 mol/L, respectively. The detection limits for the Xa and HXa were 1.2×10?8 mol/L and 5.7×10?8 mol/L, respectively. Moreover, this proposed method could be applied to determine the Xa and HXa in human urine simultaneously with satisfactory results.  相似文献   

20.
A carbon fiber paste electrode using ionic liquid as the binder (CFILE) was fabricated. The electrochemical characteristics of the electrode was examined in ferro‐/ferricyanide solution and showed better conductivity and reversibility when compared with graphite paste‐ionic liquid electrode (GPILE) and a little better than that on the carbon nanotube paste‐ionic liquid electrode (CNTILE). Glyphosate (GLY), a pesticide, exhibited excellent catalysis to the oxidation of Ru(bpy)2+3 on CFILE and brought an obvious enhancement to the electrochemiluminescence (ECL) intensity of Ru(bpy)2+3. Based on the catalytic ability of GLY, a simple ECL method for GLY detection had been established. Under optimum conditions, the enhanced ECL intensities were found to had linearly respond to the GLY concentration between 3.0×10?7 and 3.0×10?5 mol/L, and the detection limit (S/N=3) was 2.0×10?7 mol/L. The electrode also showed excellent sensitivity in detecting GLY‐spiked soybean samples. The linear range for GLY in soybean samples was 1.0×10?6–4.0×10?5 mol/L and the detection limit was 5.0×10?7 mol/L, equal to 8.45 µg GLY in per gram of soybean. The detection limit in soybean sample was lower than the USA, EU regulation and so on. If the method is coupled with the separation technology, it can be applied to detect the GLY in the contaminated samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号