首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Analytical letters》2012,45(2):323-335
ABSTRACT

A new radiofrequency capacitively coupled plasma source (r.f.CCP) was used for Cd determination in dust samples by atomic emission spectrometry. The plasma torch consists of a molybdenum tube electrode and one or two ring electrodes situated outside the quartz tube. Plasma was operated at 27.12 MHz, at low power (275 W) and low gas consumption (0.4 1 min? argon flow). The choice of the optimum operating conditions for Cd determination in dust samples dissolved in acids and pneumatically nebulized is presented. The results obtained in such samples were compared with those obtained by flame atomic absorption spectrometry (FAAS). The matrix effect of NaCl and CaCl2 on Cd emission was also studied depending of the plasma coupling system. The true limit of detection for Cd in dust sample by r.f.CCP-AES is 3 μg g?1. Concentration of Cd higher than 10 μg g?1 can be determined by the proposed method with a relative standard deviation within the range 5 - 10%. The recovery is 100 ± 10%.  相似文献   

2.
Volatile species of Ni were generated by merging acidified aqueous samples and sodium tetrahydroborate(III) in a continuous flow system. The gaseous analyte was subsequently introduced via a stream of Ar carrier into the inlet tube of the plasma torch. Inductively coupled plasma atomic emission spectrometry (ICP-AES) was used for detection. The operating conditions (chemical and physical parameters) and the concentrations of different acids were evaluated for the efficient generation of Ni vapor. The detection limit (3 sigma(blank)) was 1.8 ng mL(-1). The precision (RSD) of the determination was 4.2% at a level of 500 ng mL(-1) and 7.3% for 20 ng mL(-1) (n=10). The efficiency of the generation process was estimated to be 51%. The possible interfering effect of transition metals (Cd, Co, Cu, Cr, Fe, Mn, Zn), hydride forming elements (As, Ge, Pb, Sb, Se, Sn, Te), and Hg on Ni signal was examined. This study has demonstrated that Ni vapor generation is markedly free of interferences.  相似文献   

3.
Volatile species of Zn were generated by merging acidified aqueous samples and sodium tetrahydroborate(III) solution in a continuous flow system. The gaseous analyte was subsequently introduced via a stream of Ar carrier into the inlet tube of the plasma torch. Inductively coupled plasma optical emission spectrometry (ICP-OES) was used for detection. The operating conditions (chemical and physical parameters) and the concentrations of different inorganic (hydrochloric, nitric) and organic acids (acetic, citric, oxalic, tartaric) were evaluated for the efficient generation of Zn vapour. A detection limit (3sigma(blank)) of 4.6 ng mL(-1) was achieved. The precision (RSD) of the determination was 6.9% at a level of 250 ng mL(-1) and 4.7% for 1000 ng mL(-1) (n = 10). The efficiency of the generation process was estimated to be close to 50% in HCl. The possible interferent effect of transition metals (Cd, Co, Cu, Cr, Fe, Mn, Ni), hydride forming elements (As, Ge, Pb, Sb, Se) and Hg on Zn signal was examined. The method was validated by the determination of Zn in a certified reference material (CRM), NIST 1643d trace elements in water.  相似文献   

4.
In this study a kinetic fluorimetric method for the determination of folinic acid (leucovorin, LV) in human urine has been developed. The fluorescence emission generated by the oxidation reaction between LV and potassium permanganate in alkaline medium has been monitored at 360nm (excitation wavelength 290nm). The effect of instrumental and experimental variables on the reaction was investigated and a 0.17M sodium hydroxide, 3.3x10(-5)M KMnO(4) concentration and a temperature of 70 degrees C were selected for the reaction. The concentration range has been optimized between 10 and 700ngml(-1) of LV. The correlation coefficient was 0.9989. The sensitivity of the proposed method is 9.5ngml(-1) (expressed as limit of detection in accordance with the Clayton criterion). The determination time per sample is smaller than 200s. The proposed kinetic fluorimetric method has been applied to the direct determination of this compound in human urine. Recovery values from urine samples, containing LV, range from 82 to 110% (mean 96%).  相似文献   

5.
IntroductionEletrothermalvaporization(ETV)asameansofsampleintroductioninmicrowavein-ducedplasma(MIP)sourcespectrometryhasbeen...  相似文献   

6.
Li Z  Yang X  Guo Y  Li H  Feng Y 《Talanta》2008,74(4):915-921
Chemical vapor generation (CVG) coupled with non-dispersive atomic fluorescence spectrometry (NDAFS) has been widely used for determination of vapor-forming elements, but most of such works have been focused on single element analysis, and reports dealing with more than three elements simultaneous determination by CVG-NDAFS are rare. In this work, a sensitive and robust analytical procedure for the simultaneous determination of arsenic, antimony, bismuth and mercury in geological materials using vapor generation-four-channel non-dispersive atomic fluorescence spectrometry has been developed. The conditions of instrumentation and vapor generation of arsenic, antimony, bismuth and mercury were optimized. The optimized concentrations of KBH(4) and HCl required for analytes generation were 1.3% (m/v) and 20% (v/v), respectively. The interferences of coexisting ions and mutual hydride interferences were investigated carefully. One thousand milligrams per litre of Fe(3+); 500mgl(-1) of Pb(2+), Zn(2+), Mn(2+); 50mgl(-1) Cu(2+), Ni(2+), Cr(6+), Co(2+); 10mgl(-1) Ag(+) and 5mgl(-1) Au(3+) does not interfere with the determination of As, Sb, Bi and Hg. Associating a dilution of 1:250 (m/v) in the procedure of sample pretreatment, the tolerant concentrations of As, Sb, Bi and Hg in real geological materials are 2500, 1000, 250 and 5000ppm, respectively. Under optimal conditions, the detection limits for As, Sb, Bi and Hg were determined to be 0.068, 0.047, 0.037 and 0.008ngml(-1), respectively. The precisions for seven replicate determinations at the 5ngml(-1) of As, Sb, Bi and 1ngml(-1) of Hg were 0.47, 0.60, 0.97 and 0.93% (R.S.D.), respectively. Sample digestion was carried out on 500mg sample with 3ml HNO(3) and 10ml HCl, followed by addition of thiourea solution for the quantitative reduction of As(V), Sb(V) to As(III), Sb(III). The proposed method was successfully applied to the simultaneous determination of As, Sb, Bi and Hg in a series of certified geological reference materials using simple aqueous standard calibration technique. The results obtained are in good agreement with the certified values.  相似文献   

7.
In this paper, flame atomic absorption spectrometry was used for the determination of silver in various materials. The proposed preconcentration method is based on the continuous precipitation of silver as p-dimethylaminobenzilidene-rhodanine (PDBR) complex and dissolution of the precipitate with potassium cyanide. EDTA was added to the sample solution to mask large concentrations of Fe(III), Ni(II), Cu(II), Zn(II), Pb(II), Co(II) and Al(III). An enhancement factor of 20 was obtained for a preconcentration time of 3 min, resulting in a sampling frequency of 16 h(-1). The detection limit (3sigma) in the sample solution was 5 ngml(-1). The relative standard deviation at 30 ngml(-1) level was 4.7%. Analytical results obtained for alloy, biological reference material and ore samples analyzed were in good agreement with the certified values and comparable to those obtained with other techniques.  相似文献   

8.
A method has been described for the direct determination of Ti, Cu, Mn, Cr and Cd in solid biological samples without any chemical pretreatment by fluorination assisted electrothermal vaporization inductively coupled plasma atomic emission spectrometry (ETV-ICP-AES) with slurry sampling. A polytetrafluorethylene (PTFE) emulsion was used as a fluorinating reagent to promote the vaporization of the analytes from the graphite furnace. The interface between furnace device and ICP torch and the main factors affecting the analytical signal were investigated systematically. The detection limits for the determination of Ti, Cu, Mn, Cr and Cd are 6.3, 4.7, 10, 13 and 278 ng/mL, respectively; the relative standard deviations are in the range of 1.5 (Mn) ∼4.0% (Cd) after optimization of the operating conditions. The recommended approach has been applied to directly determine the trace elements of interest in the Chinese traditional medicine Loulu and in the solid biological standard reference material (peach leaves, GBW 08501) with satisfactory results. Received: 28 December 1998 / Revised: 9 February 1999 / Accepted: 12 February 1999  相似文献   

9.
光学玻璃中的各种元素对玻璃的光学性能有不同的影响。如加入镉可以提高玻璃折射率;砷的引入能增加玻璃的透光度,含铅玻璃具有低成本、高折射性等优点。但是镉、砷、铅均为有毒元素,玻璃加工和处理过程以及毒废弃物的处理都可能引起水、土壤、大气的污染并给人体带来一定的危害  相似文献   

10.
Cai B  Hu B  Xiong H  Liao Z  Mao L  Jiang Z 《Talanta》2001,55(1):85-91
A sensitive and rapid method for the determination of lanthanum, europium and ytterbium by inductively coupled plasma atomic emission spectrometry (ICP-AES) after solid-liquid extraction with microcrystalline naphthalene was developed. Analytes could be quantitatively adsorbed on tribromoarsenazo-cetylpyridinium bromide-naphthalene (TBA-CPB-naphthalene) packed in a column and determined by ICP-AES after desorption with 3 moll(-1) HCl. The effect of various experimental parameters, such as pH, reagent amounts, naphthalene concentrations and diverse ions, on the determination of interesting elements were investigated in detail. Under the optimized experimental conditions, the detection limits of this method for La(3+), Eu(3+) and Yb(3+) were 1.3-8.6 ngml(-1), and the relative standard deviations obtained for nine replicate determinations at a concentration of 0.5 mugml(-1) were 1.4-2.2%. The proposed method has been applied in the analysis of NIES CRM No. 8 vehicle exhaust particulates and GBW 07602 GSV-1 bush branches and leaves for La, Eu and Yb, and La in NIST SRM 1752 citrus leaves samples; the analytical results were in good agreement with reference values.  相似文献   

11.
建立了原子荧光光谱仪测定色母粒中铅的方法。将色母粒样品置于电炉中炭化,然后以HNO3–HClO4洗涤样品残渣,再加热使余酸挥发,通过控制余酸的量使试样溶液的酸度保持在0.8%~1.3%之间,用原子荧光光谱仪对样品消解液进行检测。该方法测定结果的相对标准偏差在3.66%~7.52%之间,加标回收率在82%~120%之间。与电感耦合等离子体光谱法、原子吸收光谱法和电感耦合等离子体质谱法等进行比对检测,检测结果在允许误差之内。  相似文献   

12.
微波等离子体炬原子发射光谱法测定豆制品中的金属含量   总被引:3,自引:0,他引:3  
研究了用微波消解-微波等离子体炬原子发射光谱法(MPT-AES)测定豆制品中的金属含量的方法.考察了各微量元素的分析谱线波长、载气流量、工作气流量、氧屏蔽气压力和微波前向功率对Mg,Ca,Cu,Fe,Zn,Pb,Ni,Cr,Cd,Mn 10种金属元素发射谱线强度的影响,分析了酸浓度及共存离子对其测定的影响,得到了测量不同金属离子的最佳工作条件,进而得出了在最佳条件下测量10种金属离子的工作曲线、检出限、相对标准偏差(小于5%)、回收率(98.47%~101.47%)等,并通过加标回收实验验证了方法的准确性.  相似文献   

13.
建立了一种电感耦合等离子体发射光谱法(ICP-OES)测定钴白合金中锗含量的分析方法,确定了最佳实验条件,方法的检出限为0.043 μg/mL,对钴白合金中锗的测定结果与其他法结果一致,方法的相对标准偏差RSD在1.07 %~1.91 %(n=7)之间,样品的加标回收率在98.5 %~102.1 %之间。  相似文献   

14.
This paper reports on a novel method for the determination of oxygen in silver halides using inductively coupled plasma-atomic emission spectrometry (ICP-AES). A heating system was designed and set up to heat the sample and to release oxygen which was then sent into the plasma by the argon carrier gas. A demountable extended ICP torch was assembled to prevent air from entering the analytical region of the ICP. The nonresonance near infrared atomic oxygen line, O(I) 777.19 nm, was used for the determination of oxygen. The detection limit of the method was 1.6 μg of oxygen. Pure oxygen was used for calibration. The method had a precision of 4.74% RSD for about 15 μg of oxygen in samples.  相似文献   

15.
A method for the determination of silicon by inductively coupled plasma atomic emission spectrometry (ICP-AES) is described. The procedure is based on a discontinuous generation of volatile silicon tetrafluoride in concentrated sulphuric acid medium after injecting 125 μl of 0.1%, w/v sodium fluoride solution into 100 μl of the sample. The gaseous silicon tetrafluoride is fed directly into the ICP torch by a flow of 250 ml min−1 Ar carrier gas. The calibration curve was linear up to at least 100 μg ml−1 of Si(IV) and the absolute detection limit was 9.8 ng working with a solution volume of 100 μl. The relative standard deviation for six measurements of 10 μg ml−1 of Si(IV) was 2.32%. The method was applied to the determination of silicon in water and iron ores.  相似文献   

16.
Co(III) hexamethylenedithiocarbamate has been applied as a collector in colloid flotation preconcentration of Cd from water prior to electrothermal atomic absorption spectrometry (ETAAS). All experimental parameters necessary for successful flotation have been studied and optimized. The ETAAS results were compared with those obtained by inductive coupled plasma-atomic emission spectrometry (ICP-AES). The ETAAS detection limit was found to be 0.003 microg L(-1) Cd.  相似文献   

17.
地球化学样品中钒的测定方法主要有原子吸收光谱法、等离子体发射光谱法(ICP-AES)、电感耦合等离子体质谱法(ICP-MS)和X射线荧光光谱法.选用国家一级标样,分别用4种方法测定样品含量值,依次对方法检出限、准确度、精密度、加标回收率作比较.经对比,4种方法测定值与推荐值都基本吻合.等离子体发射光谱法检出限低,线性范围更宽,准确度与精密度更好,更适用于地球化学样品中钒批量的测试.  相似文献   

18.
UV laser ablation inductively coupled plasma atomic emission spectrometry (LA-ICP-AES) has been applied to the direct determination of additives in solid poly(vinyl chloride) materials. A Nd:YAG laser, operating at its fourth harmonic (266 nm), was used with a beam masking device, in the most reproducible conditions, to introduce solid particles into the plasma torch of a simultaneous ICP-AES system. Emphasis was placed on both precision and accuracy in the analysis of PVC materials by LA-ICP-AES. A series of six in-house PVC reference materials was prepared by incorporating several additives in increasing concentrations. Three alternative methods were evaluated to certify the amount of incorporated elements: ICP-AES with sample dissolution, NAA and XRF. Satisfactory results and good agreement were obtained for seven elements (Al, Ca, Cd, Mg, Sb, Sn and Ti) among the ten incorporated. Sample homogeneity appeared to be satisfactory, and calibration graphs obtained by LA-ICP-AES for several elements are presented. Finally, the performance of the technique in terms of repeatability (1.6-5%), reproducibility (2–5%), and limits of detection was investigated.  相似文献   

19.
正丁醇萃取-原子荧光光谱法间接测定茶叶中的钼   总被引:1,自引:0,他引:1  
建立了正丁醇萃取原子荧光光谱法间接测定茶叶中钼的方法。基于As?和钼酸铵在0.3 mol/LH2SO4介质中能形成砷钼杂多酸,且形成的杂多酸可以被有效地萃取到有机溶剂中,原子荧光光谱法直接测定有机相中的砷,间接得到钼的含量。在优化的实验条件下,钼含量在0.09~15.0-g/L范围内呈良好的线性关系,方法的检出限是0.09-g/L,相对标准偏差为2.3%,据此对不同茶叶样品进行分析,加标回收率为95.2%~96.9%。本方法对茶叶中Mo的检测结果与电感耦合等离子体原子发射光谱法相符合。  相似文献   

20.
A simple and sensitive kinetic-spectrophotometric method is developed for the determination of trace vanadium(V), based on the catalytic effect of vanadium(V) on the oxidation of DBM-arsenazo by potassium bromate in 0.0138 moll(-1) phosphoric acid medium and at 100 degrees C in the presence of citric acid as activator. The absorbance is measured at 528 nm with the fixed-time method. The optimization of the operating conditions regarding concentrations of the reagents, temperature and interferences are also investigated. The working curve is linear over the concentration range 0-20 ngml(-1) of vanadium(V) with good precision and accuracy and the detection limit was down to 3.44 ngl(-1). The relative standard deviation for a standard solution of 14 ngml(-1) is 0.28% (n=11). The apparent activity energies of the catalytic reaction and the non-catalytic reaction are 73.48, 113.5 kJ/mol, respectively. The proposed method proved highly sensitive, selective and relatively rapid for the assay of vanadium at low-level range of 0-20 ngml(-1) without any pre-concentration step. Thw method was applied to the determination of vanadium(V) in steels, rice, flour, cabbage, potato, fish, shrimp and tea samples with satisfactory results. The obtained results for the steel samples were excellent agreement with the standard reference values. The analytical results of the rice, flour, cabbage, potato, fish, shrimp and tea samples were excellent agreement with those of atomic absorption spectrometry. The recovery experiments have been made for the rice, flour, cabbage, potato, fish, shrimp and tea samples except the steels; excellent results were obtained. The relative standard deviations were over the range of 0.18-2.60% and the recoveries were over the range of 98.00-102.4%, respectively. The analytical results obtained were satisfactory.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号