首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 797 毫秒
1.
A new fluorescent reagent 1,5-bis(4,6-dichloro-1,3,5-triazinylamino)naphthalene (DTAN) was synthesized. The optimum conditions of fluorescent reaction of this reagent with aniline (PA) were also investigated. Based on this reaction, a new spectrofluorimetric method was developed for the determination of aniline. The fluorescent intensity was directly proportional to the concentration of aniline in the ranges 0.05-2.0 microg mL(-1) and 2.0-50 microg mL(-1) with the detection limits of 34 ng mL(-1) and 90 ng mL(-1). This method is simple, practical and can afford good precision and accuracy and can be successfully applied to assess aniline in water samples. A possible mechanism of the change of fluorescence intensity introduced by putting the aniline into the system is also discussed.  相似文献   

2.
This study aimed at optimizing and validating a sensitive method for simultaneous determination of bisphenol A (BPA), triclosan (TCS), and tetrabromobisphenol A (TBBPA) in human serum using solid-phase extraction (SPE) and gas chromatography coupled to electron-capture negative-ionization mass spectrometry (GC-ECNI/MS). Sample preparation involved denaturation of serum proteins with formic acid followed by SPE on an Oasis HLB cartridge. Fractionation was performed on Florisil from which the phenolic compounds were eluted with methanol-dichloromethane (DCM) (5:1, v/v). The phenolic fraction was further derivatized with pentafluoropropionic acid anhydride (30 min at 70 degrees C). Further liquid-liquid partitioning using hexane-DCM (4:1, v/v) and K(2)CO(3) 3% aqueous solution was used to eliminate excess reagent and acidic by-products formed during derivatization. The cleaned extract was injected into a GC-ECNI/MS system operated in selected ion monitoring mode. For thorough method validation, each step of the procedure was rigorously optimized. The method limits of quantitation for BPA, TCS, and TBBPA were 0.28 ng mL(-1), 0.09 ng mL(-1) and 0.05 ng mL(-1), respectively. Furthermore, the method was applied to 21 Belgian human serum samples. The median concentrations obtained for BPA (0.71 ng mL(-1)) and TCS (0.52 ng mL(-1)) in Belgian human serum samples were similar to previously reported data for human fluids. Slightly higher levels of TBBPA (0.08 ng mL(-1)) were found in Belgium samples compared to Norwegian serum.  相似文献   

3.
A sensitive column switching HPLC-fluorescence detection for determination of bisphenol A (BPA) in rat brain by coupling with microdialysis was developed. A microdialysis probe was inserted into the hypothalamus of rat brain and an artificial cerebrospinal fluid was used for perfusion. BPA in brain dialysate was subjected to a fluorescent derivatization with 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride (DIB-Cl), and the excess reagent was removed by a column-switching technique. Separation was carried out on two ODS semimicro-columns with the mobile phase of acetonitrile-H(2)O-methanol-tetrahydrofuran (55:10:35:2.5, v/v) and acetonitrile-0.1 M acetate buffer (pH 3.0)-methanol (35:10:55, v/v) at a flow rate of 0.10 and 0.15 mL/min for a precolumn and a separation column, respectively. Fluorescence intensity was monitored at 475 nm with excitation of 350 nm. BPA could be sensitively detected at 0.3 ppb in 60 micro L brain microdialysate at a signal-to-noise ratio of 3. By the proposed method, concentrations of BPA in rat brain and plasma were monitored for 8 h after single i.v. or oral administration. It is proved that BPA is capable of penetrating the blood-brain barrier. The ratio of the area under the concentration-time curve of BPA in rat brain to that in blood was estimated to be about 3.0-3.8%.  相似文献   

4.
采用微波辅助合成的荧光稀土二氧化硅纳米颗粒(BHHCT-Eu3+@SiO2)为标记物,建立了快速定量检测卡那霉素(Kana)残留的荧光免疫层析方法.实验结果表明,微波辅助合成的BHHCT-Eu3+@SiO2纳米颗粒呈球形,粒径约36 nm,具有良好的荧光发射性能,最大吸收波长和最大发射波长分别为343和615 nm.将BHHCT-Eu3+@SiO2与卡那霉素抗体(Kana-ab)通过醛基化葡聚糖交联,合成了荧光标记抗体Eu3+-Kana-ab,结合定量侧向层析读数仪,建立了牛奶中Kana残留的快速定量检测方法,对Kana的检出限(IC10)为0.85 ng/mL,半数抑制浓度(IC50)为12.76 ng/mL,检测范围(IC20-IC80)为3.0~76.0 ng/mL,牛奶中的Kana的加标回收率范围为93.7%~97.4%,RSD为3.1%~4.6%,与Kana类似物的交叉反应均<1%.牛奶中Kana残留的测定结果与ELISA方法相关性良好.  相似文献   

5.
Zeng X  Zhang X  Zhu B  Jia H  Li Y  Xue J 《The Analyst》2011,136(19):4008-4012
A 4-aminonaphthalimide-based ratiometric fluorescent probe 1 employing the internal charge transfer (ICT) mechanism was designed and synthesized to detect bovine serum albumin (BSA). The interaction of 1 and BSA was investigated by fluorescence and UV-vis absorption spectroscopy. Upon treatment with BSA, the probe successfully exhibited a ratiometric fluorescent response at 540 nm and 480 nm. The fluorescent intensity ratio at 540 nm and 480 nm (F(540)/F(480)) increases linearly with BSA concentration in the range of 0-75.0 μg mL(-1) and the detection limit was about 2.4 ng mL(-1). Our strategy is expected to provide a methodology to quantify BSA either by a normal or by a ratiometric and colorimetric way with high sensitivity.  相似文献   

6.
Parabens (esters of p-hydroxybenzoic acid) and triclosan are widely used as preservatives and antimicrobial agents, respectively, in personal care products, pharmaceuticals, and food processing. Because of their widespread use and potential risk to human health, assessing human exposure to these compounds in breastfed infants is of interest. We developed a sensitive method, using a unique on-line solid-phase extraction-high performance liquid chromatography-tandem mass spectrometry system with peak focusing feature, to measure in human milk the concentrations of five parabens (methyl-, ethyl-, propyl-, butyl-, and benzyl parabens), triclosan, and six other environmental phenols: bisphenol A (BPA); ortho-phenylphenol (OPP); 2,4-dichlorophenol; 2,5-dichlorophenol; 2,4,5-trichlorophenol; and 2-hydroxy-4-methoxybenzophenone (BP-3). The method, validated by use of breast milk pooled samples, shows good reproducibility (inter-day coefficient of variations ranging from 3.5% to 16.3%) and accuracy (spiked recoveries ranging from 84% to 119% at four spiking levels). The detection limits for most of the analytes are below 1 ng mL(-1) in 100 microL of milk. We tested the usefulness of the method by measuring the concentrations of these twelve compounds in four human milk samples. We detected methyl paraben, propyl paraben, triclosan, BPA, OPP, and BP-3 in some of the samples tested. The free species of these compounds appear to be the most prevalent in milk. Nevertheless, to demonstrate the utility of these measures for exposure and risk assessment purposes, additional data about sampling and storage of the milk, and on the stability of the analytes in milk, are needed.  相似文献   

7.
Zhan W  Wei F  Xu G  Cai Z  Du S  Zhou X  Li F  Hu Q 《Journal of separation science》2012,35(8):1036-1043
A water compatible molecularly imprinted polymers (MIPs) coated stir bar for bisphenol A(BPA) was prepared with 3,3',5,5'-tetrabromobisphenol A as the dummy template molecule in this study. The dummy molecularly imprinted polymers coated stir bar (DMIPs-SB) showed better selectivity than the bars coated with polydimethylsiloxane or non-imprinted polymers when used to extract BPA and its three analogues. The saturated adsorption amount of the DMIPs coating was 3.0 times over that of the non-imprinted polymers coating. To achieve the optimum extraction performance, several parameters, including extraction and desorption time, pH value, adsorption temperature and stirring speed were investigated. The high-performance liquid chromatography combined with the DMIPs-SB was employed in the analysis of BPA in aqueous solution. The linear range of BPA concentration in aqueous medium was 0.0228-2.28 ng/mL with correlation coefficient of 0.9994 and the detection limit was about 6.84 × 10(-3) ng/mL based on three times ratio of signal to noise. This method was directly applied to the determination of trace BPA in milk with satisfactory results.  相似文献   

8.
Decanoic acid reverse micelle-based coacervates were proposed for the extraction of bisphenol A (BPA) from canned vegetables and fruits prior to its determination by liquid chromatography and fluorescence detection at lambda(exc) = 276 nm and lambda(em) = 306 nm. The procedure involved the extraction of minute quantities (300-700 mg) of homogenized food sample with an aqueous solution containing 10% of THF and 0.5% of decanoic acid, conditions under which the coacervate (around 340 microL) formed in situ and instantaneously. The overall sample treatment, which included extraction and centrifugation, took about 25-30 min, and several samples could be simultaneously treated using conventional lab equipment. No clean-up or solvent evaporation were required. Extraction efficiencies mainly depended on the decanoic acid and THF concentration in the aqueous solution and were not affected by the pH or the temperature in the ranges studied (1-4 and 20-60 degrees C, respectively). Recoveries in samples ranged between about 81 and 96%. The precision of the method, expressed as relative standard deviation, was about 3% and the quantitation limit was around 9 ng g(-1), which was far below the current specific migration limit (SML) set for BPA by the EU Commission (600 ng g(-1)). The method was successfully applied to the determination of BPA in the solid content of canned fruit salad, peaches in syrup, mango slices, red peppers, sweetcorn, green beans and peas. BPA was present at concentrations in the range from 7.8 to 24.4 ng g(-1) in canned fruits and from 55 to 103 ng g(-1) in canned vegetables.  相似文献   

9.
A single and rapid solid surface fluorescence-based flow-through optosensor has been developed for the screening of trace amounts of Zn(II) in drinking water samples. The proposed method is based on the transient immobilization of the target species: the complex formed between Zn(II) and the fluorogenic reagent p-(tosylamino)quinoline (p-TAQ) on an appropriate solid support (C(18) silica gel). The fluorescence of the complex was continuously monitored at an emission wavelength of 495 nm upon excitation at 377 nm. The instrumental, chemical and flow-injection variables were carefully investigated and optimized. The sensor was calibrated over the range of 5 - 125 ng mL(-1), obtaining a limit of detection of 0.9 ng mL(-1), a RSD of 1.8%, with a sampling frequency of 20 h(-1). The proposed method was successfully applied to different drinking water samples with recoveries between 98 and 104%.  相似文献   

10.
A high performance liquid chromatographic post-column fluorescent ion pair extraction system was developed for the analysis of quaternary ammonium and amine drugs in serum. A new fluorescent ion pair reagent, sodium alpha-(3,4-dimethoxyphenyl) cinnamonitrile-2'-sulfonate (DPS), was synthesized and characterized. The post-column extraction system consisted of a three-dimensional knitted teflon mixing coil and a membrane phase separator which was modified from an original literature design. Physostigmine and its metabolite eseroline were used as model cations. A solid phase extraction procedure using octadecylsilane columns was developed to extract the compounds and neostigmine bromide (internal standard) from human serum. The compounds were chromatographed on a diol column using a 80:20 aqueous phosphate buffer pH 4 absolute methanol mobile phase at a flow rate of 1 mL/min. Methylene chloride was used as the on-line extraction solvent for the DPS ion pairs formed. Fluorescence of the extracted ion pairs was measured using an excitation of 243 nm and an emission cut-off filter at 418 nm. Linearity was in the 2-100 ng/mL and 5-100 ng/mL ranges for physostigmine and eseroline, respectively. Detection limits based on a signal-to-noise ratio of 2, were 2 and 5 ng/mL, respectively. Precision of the method was found to be in the 1.5-3% range and percentage error in the 1.5-7% range for both compounds.  相似文献   

11.
A simple, sensitive, and selective method for determination of acetaminophen based on its oxidation using N-bromosuccinimide (NBS) to produce a highly fluorescent product. Optimization of reaction variables was carried out concerning NBS concentration, pH, temperature, reaction time, and stability time. Under optimal analytical conditions, the fluorescent intensity was measured at lambda emission. 442 nm (excitation at lambda 330 nm). The linearity range is 120-800 ng/mL with lower detection limit of 33.6 ng/mL acetaminophen. The method was applied successfully to the determination of the compound in pharmaceutical preparations, with average recovery of 100.3 +/- 2%. The method was also applied successfully to the determination of the drug in spiked plasma samples, with an average recovery of 101.2 +/- 1%. Interference effects of some compounds, present in combination with acetaminophen, were studied and the tolerance limits of these compounds were determined.  相似文献   

12.
A new HPLC procedure with precolumn derivatization and rimantadine as the internal standard for determining memantine, a candidate agent for the treatment of glaucoma in plasma and vitreous humour, has been developed and validated. Precolumn derivatization was performed with 9-fluorenylmethyl-chloroformate-chloride (FMOC-Cl) as the derivatization reagent and followed by a liquid-liquid extraction with n-hexane. Optimal conditions for derivatization were an FMOC-Cl concentration of 1.5 mM, a reaction time of 20 min, the temperature at 30°C, the borate buffer pH 8.5, and a borate buffer-acetonitrile ratio of 1:1. The derivatives were analyzed by isocratic HPLC with the fluorescence detector λex 260 nm λem 315 nm on a Novapack C(18) reversed-phase column with a mobile phase of acetonitrile-water (73:27, v/v), 40°C, and a flow rate of 1.2 mL/min. The linear range was 10-1000 ng/mL with a quantification limit of ~ 10 ng/mL for both types of samples. This analytical method may be suitable for using in ocular availability studies.  相似文献   

13.
A sensitive HPLC method with fluorescence detection was developed for the determination of bisphenol A (BPA) and bisphenol B (BPB) in human blood serum. The detection limits of the method were 0.18 and 0.20 ng/mL for BPA and BPB, respectively. A single‐step liquid–liquid extraction was used for the pre‐treatment of serum samples. The recoveries of BPA and BPB spiked to sera were 85.6 and 87.7%, respectively. The analyses of sera from both healthy and endometriotic women emphasized the absence of bisphenols in all the control cases (11 women), whereas BPA was found in 30 sera (51.7%) and BPB was found in 16 sera (27.6%) in the group of 58 patients with endometriosis; in nine of such sera BPA and BPB were present simultaneously. Only relatively to the sera quantitated, BPA concentrations ranged from 0.79 to 7.12 ng/mL (mean concentration 2.91 ± 1.74 ng/mL), whereas BPB concentrations ranged from 0.88 to 11.94 ng/mL (mean concentration 5.15 ± 4.16 ng/mL). Therefore, the presence of at least one of the two bisphenols was verified in a percentage as high as 63.8% in the sera from endometriotic women, suggesting the existence of a relationship between endometriosis and BPA and/or BPB exposure. Indeed, it is well known that bisphenols can work as xenoestrogens, owing to their structural similarity to natural and synthetic estrogens (e.g. estradiol and dietilstilbestrol). However, further studies are necessary to confirm this hypothesis and to assess the actual dose at which exposures to bisphenols are able to increase the sensitivity of the endometriotic cells to estradiol. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

14.
高效液相色谱法测定大鼠组织中双酚A和4-壬基酚浓度   总被引:8,自引:0,他引:8  
肖全伟  黎源倩  吴德生 《色谱》2004,22(6):579-582
建立了大鼠组织中双酚A和4-壬基酚的提取和含量测定方法。大鼠组织样品经甲醇-乙酸铵缓冲液匀浆、 正己烷-乙醚混合溶剂提取、氮气吹干后用流动相溶解,以乙腈-0.01 mol/L乙酸铵缓冲液(pH 4.5)(体积比为75∶25)为流动相,经C18色谱柱分离,在激发波长227 nm、发射波长313 nm下进行荧光检测。大鼠心、脑、肝和肾脏组织样品中,双酚A的检出限为3.2~4.6 ng/g,4-壬基酚的检出限为11.8~15.6 ng/g;日内检测精密度为0.89%~4.50%,日间检测精密度为3.10%~12  相似文献   

15.
The ionization constant of fluorescent reagent gibberellic acid (GA) was established spectrophotometrically. The fluorescent reaction of this reagent with lead was studied. Based on this chelation reaction, a sensitive, direct spectrofluorimetric method for the determination of trace lead with use of GA has been developed. The reaction conditions for the fluorescence system of lead with GA were studied. The lead ion can form a stable binary chelate with GA, having a ratio of 1:2 in the pH range 7.0‐8.0. The maximum excitation and emission wavelengths are 205.0 nm and 308.8 nm for the lead chelate, respectively. The reaction is instantaneous and the fluorescence intensity of the lead chelate remains stable from 20 to 150 min. Under the optimal experimental conditions the fluorescence intensity is a linear function of concentration in the range 1.0‐10.0 ng/mL of lead and the detection limit is 0.52 ng/mL of lead. Interferences of other ions were studied. The method has been successfully applied to the determination of lead in common paint.  相似文献   

16.
Regina V. Oliveira 《Talanta》2007,71(3):1233-1238
A multidimensional, selective and precise high performance liquid chromatography (HPLC) method based on direct injection of biological samples has been developed for the determination of cephalexin in skimmed and whole bovine milk. The cephalosporin antibiotic was extracted from bovine milk using an octyl restricted access medium bovine serum albumin column (C8-RAM-BSA) and analyzed on an octadecyl column using phosphate buffer (pH 7.5, 0.01 M): ACN (92:8, v/v) and ultraviolet detection at 260 nm. The calibration graph was linear in the concentration range of 25-1600 ng/mL and this is in accordance with the tolerance level of 100 ng/mL set by the FDA (Food and Drug Administration) and EU (European Union) for cephalexin as residue in bovine milk. The intra- and inter-day coefficients of variation for the replicate analysis at the quality control levels were less than 15% while the transfer efficiency was in the range of 90.2-92.3%. The limits of detection and quantification were 10 and 20 ng/mL, respectively.  相似文献   

17.
A sensitive procedure was developed for determination of bismuth (Bi) in milk samples by hydride generation atomic fluorescence spectrometry (HG-AFS) after microwave-assisted sample digestion with HNO3 and H2O2. The method provides a sensitivity of 1832 fluorescence units (ng/mL) with a detection limit of 0.01 ng/mL, which corresponds to 20 pg absolute limit of detection, equivalent to 0.50 ng/g in the original sample. Application of the methodology to cow milk samples from the Spanish market showed the presence of Bi at a concentration of 11.8-28.8 ng/g, which compared well with data obtained after dry ashing of samples and with data obtained by inductively coupled plasma-mass spectrometry after microwave-assisted digestion.  相似文献   

18.
IntroductionInrecentyears ,aroylhydrazoneswhichcontaingroup—CONHN CH—havebeentestedasfluori metricreagentsforthedeterminationofaluminum ,gallium ,scandium ,zinc ,copperandothermetalions[17] .Thereactionofametalionwithachelatingagentproducesarigidmoleculewitha…  相似文献   

19.
A high-performance liquid chromatographic method was optimized and validated for the determination of atenolol and chlorthalidone (CT) in human breast milk. The milk samples were extracted and purified using ACN and phosphoric acid for precipitation of proteins followed by removal of ACN and milk fats by extraction with methylene chloride. The samples were applied, after an extraction procedure, to a cyanide column using a mobile phase consisting of ACN/water (35:65 v/v) and buffered at pH 4.0 with flow rate of 1.0 mL/min. Quantitation was achieved with UV detection at 225 nm using guaifenesin as the internal standard. The effectiveness of protein precipitation and clean up procedure were investigated. The method was validated over the range of 0.3-20 microg/mL for atenolol and 0.25-5 microg/mL for CT.  相似文献   

20.
Bisphenol A (BPA) is a widely used industrial chemical in the manufacturing of polycarbonate plastic bottles, food and beverage can linings, thermal receipts, and dental sealants. Animal and human studies suggest that BPA may disrupt normal hormonal function and hence, potentially, have negative effects on the human health. While total BPA is frequently reported, it is recognized that free BPA is the biologically active form and is rarely reported in the literature. The objective of this study was to develop a sensitive and improved method for the measurement of free and total BPA in human urine. Use of a labeled conjugated BPA (bisphenol A-d6 β-d-glucuronide) allowed for the optimization of the enzymatic reaction and permitted an accurate determination of the conjugated BPA concentration in urine samples. In addition, a 13C12-BPA internal standard was used to account for the analytical recoveries and performance of the isotope dilution method. Solid-phase extraction (SPE) combined with derivatization and analysis using a triple quadrupole GC-EI/MS/MS system achieved very low method detection limit of 0.027 ng/mL. BPA concentrations were measured in urine samples collected during the second and third trimesters of pregnancy in 36 Canadian women. Total maternal BPA concentrations in urine samples ranged from not detected to 9.40 ng/mL (median, 1.21 ng/mL), and free BPA concentrations ranged from not detected to 0.950 ng/mL (median, 0.185 ng/mL). Eighty-six percent of the women had detectable levels of conjugated BPA, whereas only 22 % had detectable levels of free BPA in their urine. BPA levels measured in this study agreed well with data reported internationally.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号