首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A new polymeric coating consisting of a dual-phase, polydimethylsiloxane (PDMS) and polypyrrole (PPY) was developed for the stir bar sorptive extraction (SBSE) of antidepressants (mirtazapine, citalopram, paroxetine, duloxetine, fluoxetine and sertraline) from plasma samples, followed by liquid chromatography analysis (SBSE/LC-UV). The extractions were based on both adsorption (PPY) and sorption (PDMS) mechanisms. SBSE variables, such as extraction time, temperature, pH of the matrix, and desorption time were optimized, in order to achieve suitable analytical sensitivity in a short time period. The PDMS/PPY coated stir bar showed high extraction efficiency (sensitivity and selectivity) toward the target analytes. The quantification limits (LOQ) of the SBSE/LC-UV method ranged from 20 ng mL−1 to 50 ng mL−1, and the linear range was from LOQ to 500 ng mL−1, with a determination coefficient higher than 0.99. The inter-day precision of the SBSE/LC-UV method presented a variation coefficient lower than 15%. The efficiency of the SBSE/LC-UV method was proved by analysis of plasma samples from elderly depressed patients.  相似文献   

2.
A simple, rapid, and sensitive method for the quantitative monitoring of five sulfonamide antibacterial residues (SAs) in milk was developed by stir bar sorptive extraction (SBSE) coupling to high performance liquid chromatography with diode array detection. The analytes were concentrated by SBSE based on poly (vinylimidazole–divinylbenzene) monolithic material as coating. The extraction procedure was very simple, milk was diluted with water then directly sorptive extraction without elimination of fats and protein in samples was required. To achieve optimum extraction performance for SAs, several parameters, including extraction and desorption time, desorption solvent, ionic strength and pH value of sample matrix were investigated. Under the optimized experimental conditions, low detection limits (S/N = 3) quantification limits (S/N = 10) of the proposed method for the target compounds were achieved within the range of 1.30–7.90 ng/mL and 4.29–26.3 ng/mL from spiked milk, respectively. Good linearities were obtained for SAs with the correlation coefficients (R2) above 0.996. Finally, the proposed method was successfully applied to the determination of SAs compounds in different milk samples and satisfied recoveries of spiked target compounds in real samples were obtained.  相似文献   

3.
A comparison is made between static headspace analysis and stir bar sorptive extraction (SBSE) for the quantitative determination of furan. The SBSE technique was optimised and evaluated using two example food matrices (coffee and jarred baby food). The use of the SBSE technique in most cases, gave comparable results to the static headspace method, using the method of standard additions with d4-labelled furan as an internal standard. Using the SBSE method, limits of detection down to 2 ng g−1 were achieved, with only a 1 h extraction. The method was performed at ambient temperatures, thus eliminating the possibility of formation of furan during extraction.  相似文献   

4.
A new method, stir bar sorptive extraction (SBSE) with in situ derivatization and thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS), which is used for the determination of trace amounts of chlorophenols, such as 2,4-dichlorophenol (2,4-DCP), 2,4,6-trichlorophenol (2,4,6-TrCP), 2,3,4,6-tetrachlorophenol (2,3,4,6-TeCP) and pentachlorophenol (PCP), in tap water, river water and human urine samples, is described. The derivatization conditions with acetic acid anhydride and the SBSE conditions such as extraction time are investigated. Then, the stir bar is subjected to TD followed by GC-MS. The detection limits of the chlorophenols in tap water, river water and human urine samples are 1-2, 1-2, and 10-20 pg ml−1 (ppt), respectively. The calibration curves for the chlorophenols are linear and have correlation coefficients higher than 0.99. The average recoveries of the chlorophenols in all the samples are higher than 95% (R.S.D. < 10%) with correction using added surrogate standards, 2,4-dichlorophenol-d5, 2,4,6-trichlorophenol-13C6, 2,3,4,6-tetrachlorophenol-13C6 and pentachlorophenol-13C6. This simple, accurate, sensitive and selective analytical method may be applicable to the determination of trace amounts of chlorophenols in liquid samples.  相似文献   

5.
Kole PL  Millership J  McElnay JC 《Talanta》2011,85(4):1948-1958
A novel stir bar sorptive extraction (SBSE) method coupled with high performance liquid chromatography (HPLC) and UV detection for the extraction of diclofenac (DIC) from paediatric urine samples has been developed and validated. Selectivity and sensitivity being the prime objectives of the bioanalytical method for clinical samples, an optimised SBSE protocol was developed that selectively extracted DIC from various concurrently administered drugs. The validated assay was found to be linear (r = 0.9999) over a concentration range of 100-2000 ng mL−1. SBSE showed consistent recoveries (∼70%) of DIC across the validated linearity range. Overall, the method exhibited excellent accuracy and precision across all QC concentrations, tested over three days. Calculated LOD and LOQ were found to be 12.03 ng mL−1 and 36.37 ng mL−1, respectively, however, for the experimental purposes, 100 ng mL−1 was considered as the validated LOQ (accuracy and precision at this LQC was <20%). Further, studies on various attributes of the stir bar/SBSE, showed no significant inter- and intra-stir bar variability for DIC extraction. There was no carryover effect with re-use of conditioned stir bars and for the first time, a systematic investigation on the effect of ageing of stir bars on their extraction efficiency was carried out. Results showed that, for the present study, stir bars which were used 150 times were still functional based on in-house acceptance criteria and extraction efficiency. The validated method was successfully applied to the analysis of DIC in paediatric clinical trial samples.  相似文献   

6.
Giordano A  Richter P  Ahumada I 《Talanta》2011,85(5):2425-2429
The rotating disk sorptive extraction (RDSE) technique was applied to the determination of pesticides in aqueous samples. Pesticides of different polarities were considered in this study: chlorpyrifos, diazinon, fenvalarate, cyhalothrin, cypermethrin, lindane and malathion. The sorptive/desorptive behavior of the pesticides was studied using a rotating disk containing a polydimethylsiloxane (PDMS) phase on one of its surfaces. The analyte polarity was a significant factor in the extraction time; shorter extraction times were required for the more apolar pesticides. The optimum variables for the extraction of all analytes were: extraction time of 3 h, sample volume of 25 mL, rotational velocity of the disk 1250 rpm, desorption time of 30 min using methanol. For pesticides with values of Log Kow > 4, the extraction time can be reduced to 30 min for a quantitative extraction. Under these conditions, recoveries between 76% and 101% were obtained for the target pesticides, and the repeatability of the methodology, expressed as relative standard deviation, was determined to be between 10% and 20%. Additionally, the limits of detection of the analytes were lower than 3.1 μg L−1. The extraction method developed using the RDSE was compared to a stir bar sorptive extraction (SBSE) under the same conditions. It can be observed that the extraction using the rotating disk offers higher recoveries because of its higher PDMS volume and its higher surface area to volume ratio that allows for improved mass transfer.  相似文献   

7.
Trace and ultra-trace analysis can be difficult to achieve, especially for polar, more volatile, and/or thermally unstable analytes. A novel technique, coined ICE Concentration Linked with Extractive Stirrer (ICECLES), may help address this problem. The implementation of ICECLES described here combines stir bar sorptive extraction (SBSE) with freeze concentration (FC), where an aqueous solution is frozen during SBSE in order to concentrate analytes into a polydimethylsiloxane (PDMS) coated stir bar. Five test probe molecules with a range of log Kows (2-butanol, benzyl alcohol, benzaldehyde, dimethyl trisulfide and bromobenzene) were prepared from aqueous solutions using ICECLES. Thermal desorption gas–chromatography mass–spectrometry was then used to quantify these analytes. Parameters affecting the performance of ICECLES (e.g., freeze rate) were evaluated, with extraction at lower speeds resulting in higher extraction efficiencies, whereas the freeze rate and initial analyte concentration only had a minor effect. ICECLES produced much higher extraction efficiencies than SBSE alone, with signal enhancements of up to 474× SBSE. ICECLES also provided excellent reproducibility and lower LODs than SBSE for all compounds tested. ICECLES performed well when used to analyze multiple triazine pesticides and breakdown products in environmental surface waters. Overall, the ICECLES technique was excellent at preparing aqueous samples for trace analysis and shows promise as a novel analytical sample preparation technology.  相似文献   

8.
Yuling Hu 《Talanta》2010,82(2):464-4294
A novel stir bar coated with molecularly imprinted polymer (MIP) as selective extraction phase for sorptive extraction of triazine herbicides was developed. The stir bar was prepared by chemically bonding the MIP to the glass bar to improve its stability. A homogeneous and porous structure was observed on the stir bar surface. Extraction performance shows that the MIP-coated stir bar has stronger affinity to the template molecule terbuthylazine as compared with that of the reference stir bar without addition of template. Owning to the shape and structural compatibility, the obtained stir bar also demonstrated specific selectivity to the structural related-compounds of nine triazines, and thus can be applied to simultaneous determination of these compounds from complex samples coupled with high performance liquid chromatography. Four complex samples with different matrix, including rice, apple, lettuce and soil were used to evaluate this proposed method. The limits of detection obtained are in the range of 0.04-0.12 μg L−1, and the recoveries for the spiked rice, apple, lettuce and soil samples were 80.8-107.7%, 80.6-107.8%, 72.0-109.8% and 89.0-114.8% with RSD from 1.2 to 7.9%, respectively. Moreover, this MIP-coated stir bar was firm, durable and can be prepared simply and reproducibly. The developed coating method would be useful to prepare a range of selective stir bars in order to extend the applicability of stir bar sorptive extraction (SBSE) in complex sample analysis.  相似文献   

9.
In this work, polyurethane foams (PU) were developed, characterized and applied as new generation polymeric phases for stir bar sorptive extraction (SBSE) using seven triazinic herbicides (simazine, atrazine, prometon, ametryn, propazine, prometryn and terbutryn) as model compounds in water matrices. Assays performed for PU synthesis and characterization demonstrated that seven formulations presented remarkable stability and excellent mechanical and chemical resistance, for which the P6 formulation showed the best results. By performing systematic assays on 25 mL of water samples spiked at the 10 μg/L level, it was established that the best experimental conditions using stir bars coated with P6 were an equilibrium time of 6 h (1250 rpm), 5% of methanol as organic modifier, followed by liquid desorption with methanol as back extraction solvent under ultrasonic treatment (20 min) and high performance liquid chromatography with diode array detection (SBSE(PU)-LD-HPLC-DAD). This methodology provided good recoveries (20.4-62.0%) and remarkable reproducibility (R.S.D. <7.0%). Furthermore, excellent linear dynamic ranges between 0.9 and 16.7 μg/L (r2 > 0.9949) and detection limits (0.1-0.5 μg/L) at trace level were also achieved. The application of the proposed analytical approach to analyze triazinic herbicides in ground and superficial water matrices, showed remarkable performance and by using the standard addition methodology the matrix effects are negligible. By comparing the best PU formulation (P6, 71 μL) with commercial stir bars coated with PDMS (126 μL), recoveries normalized to the polymeric volume up to five times higher (atrazine) were attained. The ability of PU foams to extract the more polar compounds rather than PDMS makes this polymer a very valuable contribution for SBSE.  相似文献   

10.
A novel hyphenated technique, namely the combination of stir bar sorptive extraction (SBSE) with isotope dilution direct analysis in real time (DART) Orbitrap™ mass spectrometry (OT-MS) is presented for the extraction of phosphoric acid alkyl esters (tri- (TnBP), di- (HDBP), and mono-butyl phosphate (H2MBP)) from aqueous samples. First, SBSE of phosphate esters was performed using a Twister™ coated with 24 μL of polydimethylsiloxane (PDMS) as the extracting phase. SBSE was optimized for extraction pH, phase ratio (PDMS volume/aqueous phase volume), stirring speed, extraction time and temperature. Then, coupling of SBSE to DART/Orbitrap-MS was achieved by placing the Twister™ in the middle of an open-ended glass tube between the DART and the Orbitrap™. The DART mass spectrometric response of phosphate esters was probed using commercially available and synthesized alkyl phosphate ester standards. The positive ion full scan spectra of alkyl phosphate triesters (TnBP) was characterized by the product of self-protonation [M + H]+ and, during collision-induced dissociation (CID), the major fragmentation ions corresponded to consecutive loss of alkyl chains. Negative ionization gave abundant [M − H] ions for both HDnBP and H2MnBP. Twisters™ coated with PDMS successfully extracted phosphate acid esters (tri-, di- and mono-esters) granted that the analytes are present in the aqueous solution in the neutral form. SBSE/DART/Orbitrap-MS results show a good linearity between the concentrations and relative peak areas for the analytes in the concentration range studied (0.1–750 ng mL−1). Reproducibility of this SBSE/DART/Orbitrap-MS method was evaluated in terms of %RSD by extracting a sample of water fortified with the analytes. The %RSDs for TnBP, HDnBP and H2MnBP were 4, 3 and 3% (n = 5) using the respective perdeuterated internal standards. Matrix effects were investigated by matrix matched calibration standards using underground water samples (UWS) and river water samples (RWS). Matrix effects were effectively compensated by the addition of the perdeuterated internal standards. The application of this new SBSE/DART/Orbitrap-MS method should be very valuable for on-site sampling/monitoring, limiting the transport of large volumes of water samples from the sampling site to the laboratory.  相似文献   

11.
Cd(II) imprinted 3-mercaptopropyltrimethoxysilane (MPTS)-silica coated stir bar was prepared by sol–gel technique combining with a double-imprinting concept for the first time and was employed for stir bar sorptive extraction (SBSE) of trace Cd(II) from water samples followed by inductively coupled plasma mass spectrometry (ICP-MS) detection. A tetramethoxysilane (TMOS) coating was first in situ created on the glass bar surface. Afterward, a sol solution containing MPTS as the functional precursor, ethanol as the solvent and both Cd(II) and surfactant micelles (cetyltrimethylammonium bromide, CTAB) as the template was again coated on the TMOS bar. The structures of the stir bar coating were characterized by FT-IR spectroscopy. Round-bottom vial was used for the extraction of Cd(II) by SBSE to avoid abrasion of stir bar coatings. The factors affecting the extraction of Cd(II) by SBSE such as pH, stirring rate and time, sample/elution volume and interfering ions have been investigated in detail, and the optimized experimental parameters were obtained. Under the optimized conditions, the adsorption capacities of non-imprinted and imprinted coating stir bars were found to be 0.5 μg and 0.8 μg bar−1. The detection limit (3σ) based on three times standard deviations of the method blanks by 7 replicates was 4.40 ng L−1 and the relative standard deviation (RSD) was 3.38% (c = 1 μg L−1, n = 7). The proposed method was successfully applied for the analysis of trace Cd(II) in rain water, East Lake and Yangtze River water. To validate the proposed method, certified reference material of GSBZ 50009-88 environmental water was analyzed and the determined value is in a good agreement with the certified value. The developed method is rapid, selective, sensitive and applicable for the analysis of trace Cd(II) in environmental water samples.  相似文献   

12.
A novel method based on ultrasonic solvent extraction and stir bar sorptive extraction for the analysis of phenolic organic pollutants including chlorophenols, bisphenol-A, 4-tert-octylphenol and 4-nonylphenol in soil samples was developed. The different parameters that affect both the extraction of analytes from the soil samples, such as solvent selection, extraction time, and the partitioning from the solvent/water mix to poly(dimethylsiloxane) (PDMS) were studied. The final selected conditions consisted of the extraction of 1 g of soil with 15 mL methanol by sonication for 30 min. The methanol extract was mixed with 85 mL of Milli-Q water and extracted by means of stir bar sorptive extraction with in situ derivatisation. The stir bars were analyzed by thermal desorption–gas chromatography–mass spectrometry (TD–GC–MS). The effects of the matrix on the recovery of the various pollutants under the developed method were studied using two soils with very different physicochemical properties. Method sensitivity, linearity, repeatability, and reproducibility were also studied. Validation and accuracy of the method were conducted by analyzing two commercial certified reference materials and by comparing the analysis of real samples with the proposed method and a classical method using pressurized solvent extraction (PSE)–GC–MS. The main advantage of this method is a substantial solvent reduction. For the extraction of only 1 g of solid sample allowing limits of detection ranging from 0.2 to 1.7 μg kg−1 dw. Repeatability and reproducibility variation were lower than 20% for all investigated compounds. Results of the certified reference materials and the real samples verify the high accuracy of this method.  相似文献   

13.
Silicone rods with a diameter of 1 mm and 10 mm long were used to extract polycyclic aromatic hydrocarbons (PAHs) from water samples and for the rapid screening of highly contaminated waste material. The rods were placed in a 15 ml glass vial for the extraction of the analytes, which involved shaking (300 min−1) the sample for 3 h. After extraction the rods were placed into 250 μl inserts of 2 ml vials filled with 100 μl of an acetonitrile-water mixture (4:1) and desorption was performed with sonication for 10 min. Then the PAHs were determined using LC and fluorescence detection. Recoveries of the rod extraction ranged between 62 and 97% and the detection limits were between 0.1 and 1.2 ng l−1. These results are comparable with those of stir bar sorptive extraction (SBSE). Although the rods are reusable, their low price means they can be discarded if contaminated, eliminating the need for expensive cleaning. One disadvantage compared to SBSE is the longer extraction time needed to reach equilibrium.  相似文献   

14.
搅拌棒吸附萃取涂层研制进展   总被引:2,自引:0,他引:2  
搅拌棒吸附萃取(SBSE)是20世纪90年代末发展起来的一种新型无溶剂样品前处理技术,具有固定相体积大、萃取容量高、无需外加搅拌子、可避免竞争性吸附、能在自身搅拌的同时实现萃取富集等优点,已广泛应用于环境、食品和生物等复杂样品中目标物质的痕量分析。涂层是SBSE技术的核心,决定了萃取选择性和容量。本文简要介绍了SBSE涂层的萃取原理、萃取解吸模式及其影响因素,重点阐述了近年SBSE涂层制备技术与方法,探讨了SBSE涂层发展中的不足,并展望了其发展趋势。  相似文献   

15.
利用相转换法制备了聚酰亚胺吸附萃取搅拌棒,用5种有机酚作为评价标样,并与现有商品化吸附萃取搅拌棒进行比较。优化了萃取搅拌速度、溶液离子强度、萃取温度、萃取时间以及热解析温度和时间。在最佳实验条件下,100 mL 样品,30% NaCl,在25℃下,经活化5 min 后的聚酰亚胺吸附搅拌棒萃取30 min (800 r/ min),然后300℃热解析4 min,使目标物脱附,再进行色谱分析。目标物在大于两个数量级浓度范围内具有良好的线性(R≥0.9995),定量限(LOQ,S/ N=10)为0.028~0.123μg/ L,重复性为1.6%~9.7%。将SBSE 与气相色谱-质谱联用,对海水、自来水和污水中的酚类进行定性与定量分析,结果表明,聚酰亚胺吸附萃取搅拌棒具有良好的选择性,最高热解析温度350℃,在分析水中痕量极性化合物领域具有广阔应用前景。  相似文献   

16.
A method for the determination of stale-flavor carbonyl compounds including E-2-octenal, E-2-nonenal, E,Z-2,6-nonadienal and E,E-2,4-decadienal in beer was developed using stir bar sorptive extraction (SBSE) with in-situ derivatization followed by thermal desorption-GC-MS analysis. The derivatization conditions with O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine and the SBSE conditions--sampling mode, salt addition, sample volume, polydimethylsiloxane volume (sample/polydimethylsiloxane phase ratio) and extraction time--were examined. The method showed good linearity over the concentration range from 0.1 to 10 ng ml(-1) for all analytes and the correlation coefficients were higher than 0.9993. The limits of detection ranged from 0.021 to 0.032 ng ml(-1) for all analytes. The recoveries (98-101%) and precision (RSD 2.4-7.3%) of the method were examined by analyzing beer samples fortified at the 0.5-ng ml(-1) level. The method was successfully applied to low-level concentration samples.  相似文献   

17.
Cui H  Hua L  Hou K  Wu J  Chen P  Xie Y  Wang W  Li J  Li H 《The Analyst》2012,137(2):513-518
A home-made stir bar sorptive extraction (SBSE) apparatus was combined to a single photon ionization time-of-flight mass spectrometer (SPI-TOFMS) for rapid and sensitive determination of trace volatile organic compounds (VOCs) in water. The home-made SBSE bar, low-cost and disposable, was used for VOCs extraction. A thermal desorption (TD) device was designed to desorb the analytes from the SBSE bar, and a high throughput interface was developed to transfer the analytes into the ionization chamber of the SPI-TOFMS. The combination of large extraction volume of SBSE bar, and the direct measurement power of SPI-TOFMS enable a short analysis time for VOCs in water with high sensitivity, for example the limits of detection (LODs) were in the range of 7.4-11.1 ng L(-1) for benzene, toluene, and p-xylene (BTX) within 15 min. BTX aqueous solutions were chosen to demonstrate the quantitative capability, the linear range was from 0.05 to 100 μg L(-1) and the correlation coefficients were better than 0.996. The proposed method was successfully applied for the analysis of VOCs in urban river water.  相似文献   

18.
A novel extraction procedure for stir bar sorptive extraction (SBSE) termed sequential SBSE was developed. Compared to conventional SBSE, sequential SBSE provides more uniform enrichment over the entire polarity/volatility range for organic pollutants at ultra-trace levels in water. Sequential SBSE consists of a SBSE performed sequentially on a 5-mL sample first without modifier using one stir bar, then on the same sample after addition of 30% NaCl using a second stir bar. The first extraction with unmodified sample is mainly targeting solutes with high Kow (logKow>4.0), the second extraction with modified sample solution (containing 30% NaCl) is targeting solutes with low and medium Kow (logKow<4.0). After extraction the two stir bars are placed in a single glass desorption liner and are simultaneously desorbed. The desorbed compounds were analyzed by thermal desorption and gas chromatography-mass spectrometry (TD-GC-MS). Recovery of model compounds consisting of 80 pesticides (organochlorine, carbamate, organophosphorus, pyrethroid, and others) for sequential SBSE was evaluated as a function of logKow (1.70-8.35). The recovery using sequential SBSE was compared with those of conventional SBSE with or without salt addition (30% NaCl). The sequential approach provided very good recovery in the range of 82-113% for most of the solutes, and recovery less than 80% for only five solutes with low Kow (logKow<2.5), while conventional approaches (with or without salt addition) showed less than 80% recovery for 23 and 41 solutes, respectively. The method showed good linearity (r2>0.9900) and high sensitivity (limit of detection: <10ngL(-1)) for most of the model compounds even with the scan mode in the MS. The method was successfully applied to screening of pesticides at ngL(-1) level in river water samples.  相似文献   

19.
Polyurethane (PU) foams were applied for stir bar sorptive extraction of five triazinic metabolites (desethyl-2-hydroxyatrazine, desisopropylatrazine, desethylatrazine, 2-hydroxyatrazine and desethylterbuthylazine) in water matrices, followed by liquid desorption and high performance liquid chromatography with diode array detection (SBSE(PU)-LD/HPLC-DAD). The optimum conditions for SBSE(PU)-LD were 5 h of extraction (1000 rpm) and 5% (v/v) of methanol for the analysis of desethyl-2-hydroxyatrazine and 2-hydroxyatrazine, 15% (w/v) of sodium chloride for the remaining compounds and acetonitrile as back-extraction solvent (5 mL) under ultrasonic treatment (60 min). The methodology provided recoveries up to 26.3%, remarkable precision (RSD < 2.4%), excellent linear dynamic ranges between 5.0 and 122.1 μg/L (r2 > 0.9993) and convenient detection limits (0.4-1.3 μg/L). The proposed method was applied in the analysis of triazinic metabolites in tap, river and ground waters, with remarkable performance and negligible matrix effects. The comparison of the recoveries obtained by PU and commercial stir bars was also performed, where the yields achieved with the former were up to ten times higher proving that PU is appropriate for analysis at trace level of this type of polar compounds in water matrices.  相似文献   

20.
This study presents the optimization and application of an analytical method based on the use of stir bar sorptive extraction (SBSE) gas chromatography coupled to mass spectrometry (GC–MS) for the ultra-trace analysis of POPs (Persistent Organic Pollutants) in Arctic ice. In a first step, the mass-spectrometry conditions were optimized to quantify 48 compounds (polycyclic aromatic hydrocarbons, brominated diphenyl ethers, chlorinated biphenyls, and organochlorinated pesticides) at the low pg/L level. In a second step, the performance of this analytical method was evaluated to determine POPs in Arctic cores collected during an oceanographic campaign. Using a calibration range from 1 to 1800 pg/L and by adjusting acquisition parameters, limits of detection at the 0.1–99 and 102–891 pg/L for organohalogenated compounds and polycyclic aromatic hydrocarbons, respectively, were obtained by extracting 200 mL of unfiltered ice water. α-hexachlorocyclohexane, DDTs, chlorinated biphenyl congeners 28, 101 and 118 and brominated diphenyl ethers congeners 47 and 99 were detected in ice cores at levels between 0.5 to 258 pg/L. We emphasise the advantages and disadvantages of in situ SBSE in comparison with traditional extraction techniques used to analyze POPs in ice.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号