首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This study reports the fabrication of an amperometric cholesterol biosensor based on cholesterol oxidase (ChOx), SnO2NPs and Nafion-modified carbon paste enzyme electrodes (CPE/SnO2NPs-ChOx/Naf). The electrochemical characterisations of BCPE and CPE/SnO2NPs were performed using CV and EIS. The determination of cholesterol was carried out by electrochemical oxidation of H2O2 at 0.6 V vs. Ag/AgCl. The CPE/SnO2NPs-ChOx/Naf presented a linear range from 0.20 μ.mol L?1 to 4.95 μmol L?1 with a low limit of detection (0.04 μ.mol L?1). In addition, the optimal values for pH and temperature were found to be 7.5 and 35°C, respectively. The CPE/SnO2NPs-ChOx/Naf was used for the determination of cholesterol in serum samples and good results were obtained.  相似文献   

2.
In this research a novel osmium complex was used as electrocatalyst for electroreduction of oxygen and H2O2 in physiological pH solutions. Electroless deposition at a short period of time (60 s), was used for strong and irreversible adsorption of 1,4,8,12‐tetraazacyclotetradecane osmium(III) chloride (Os(III)LCl2) ClO4 onto single‐walled carbon nanotubes (SWCNTs) modified GC electrode. The modified electrode shows a pair of well defined and reversible redox couple, Os(IV)/Os(III) at wide pH range (1–8). The glucose biosensor was fabricated by covering a thin film of glucose oxidase onto CNTs/Os‐complex modified electrode. The biosensor can be used successfully for selective detection of glucose based on the decreasing of cathodic peak current of oxygen. The fabricated biosensor shows high sensitivity, 826.3 nA μM?1cm?2, low detection limit, 56 nM, fast response time <3 s and wide calibration range 1.0 μM–1.0 mM. The biosensor has been successfully applied to determination of glucose in human plasma. Because of relative low applied potential, the interference from electroactive existing species was minimized, which improved the selectivity of the biosensor. The apparent Michaelis‐Menten constant of GOx on the nanocomposite, 0.91 mM, exhibits excellent bioelectrocatalytic activity of immobilized enzyme toward glucose oxidation. Excellent electrochemical reversibility, high stability, technically simple and possibility of preparation at short period of time are of great advantages of this glucose biosensor.  相似文献   

3.
A hemoglobin‐titanate composite based biosensor was chosen for determination of H2O2 in an acidic medium. CV results of the Hb‐titanate modified pyrolytic graphite electrode showed a pair of well‐defined, quasi‐reversible redox peaks centered at ?246 mV (vs. Ag/AgCl) in a pH 5.0 HAc‐NaAc buffer solution. The modified electrode exhibited good electrocatalytic response for monitoring H2O2 and had a large linear detection range from 20 μM to 3.2 mM with a detection limit of 8 μM (S/N=3) and a sensitivity of 29.7 mA M?1 cm?2 in the pH 5.0 solution. The biosensor also possessed good long term storage stability.  相似文献   

4.
Direct electrochemistry of cholesterol oxidase (ChOx) immobilized on the conductive poly‐3′,4′‐diamine‐2,2′,5′,2″‐terthiophene (PDATT) was achieved and used to create a cholesterol biosensor. A well‐defined redox peak was observed, corresponding to the direct electron transfer of the FAD/FADH2 of ChOx, and the rate constant (ks) was determined to be 0.75 s?1. Glutathione (GSH) covalently bonded with PDATT was used as a matrix for conjugating AuNPs, ChOx, and MP, simultaneously. MP co‐immobilized with ChOx on the AuNPs‐GSH/PDATT exhibited an excellent amperometric response to cholesterol. The dynamic range was from 10 to 130 μM with a detection limit of 0.3±0.04 μM.  相似文献   

5.
In this study, a sensitive nicotinamide adenine dinucleotide (NADH) biosensor based on Au‐Copper oxide nanocomposite modified carbon ceramic electrode (Au?CuO/CCE) was introduced. The developed NADH biosensor was prepared by controlled electrodeposition of copper and Au nanoparticles on the surface of a renewable CCE and was turned to Au?CuO/CCE by cycling the potential in alkaline media. The prepared electrode was carefully characterized with scanning electron microscopy, X‐ray diffraction, atomic force microscopy and cyclic voltammetry techniques. According to scan rate study, surface coverage (Γ) of the fabricated Au?CuO/CCE was calculated to be 1.54×10?8 mol cm?2 which was 3 time more than CuO/CCE. The fabricated electrode is well stable which could be reliably utilized for the determination of NADH with amperometry technique over the concentration range of 1–29 μM with sensitivity and detection limit (S/N=3) of 0.1025 μA μM?1 and 0.09 μM respectively. The prepared biosensor was used for NADH determination in serum samples with fast response time and satisfactory analytical results.  相似文献   

6.
We report on a highly sensitive electrochemical biosensor for determination of cholesterol. The biosensor was fabricated by co-immobilizing bi-enzymes, cholesterol oxidase (ChOx), and horseradish peroxidase (HRP). Voltammetric technique such as cyclic voltammetry and impedance experiment were used to study the characterization of modified electrode step by step. The developed sensor is cheap, disposable, portable and exhibits higher sensitivity. The biosensor expressed a wide linear range up to 300 mg dL–1 in a physiological condition (pH 7.0), with a correlation coefficient of 0.9969. A sensitivity of 13.28 μA mg–1 dL cm?2 which makes it very promising for the clinical determination of cholesterol.  相似文献   

7.
《Electroanalysis》2004,16(4):268-274
An amperometric method for the determination of the neurotoxic amino acid β‐N‐oxalyl‐L ‐α,β‐diaminopropionic acid (β‐ODAP) using a screen printed carbon electrode (SPCE) is reported. The electrode material was bulk‐modified with manganese dioxide and used as a detector in flow injection analysis (FIA). The enzyme glutamate oxidase (GlOx) was immobilized in a Nafion‐film on the electrode surface. The performance of the biosensor was optimized using glutamate as an analyte. Optimum parameters were found as: operational potential 440 mV (vs. Ag/AgCl), flow rate 0.2 mL min?1, and carrier composition 0.1 mol L?1 phosphate buffer (pH 7.75). The same conditions were used for the determination of β‐ODAP. The signal was linear within the concentration range 53–855 μmol L?1 glutamate and 195–1950 μmol L?1 β‐ODAP. Detection limits (as 3σ value) for both analytes were 9.12 and 111.0 μmol L?1, respectively, with corresponding relative standard deviations of 3.3 and 4.5%. The biosensor retained more than 73% of its activity after 40 days of on‐line use.  相似文献   

8.
An amperometric tyramine biosensor based on poly‐L‐lysine (PLL) and Fe3O4 nanoparticles (Fe3O4NP) modified screen printed carbon electrode (SPCE) was developed. PLL was formed on the SPCE by the electropolymerization of L‐lysine. Subsequently, Fe3O4NP suspension prepared in chitosan (CH) solution was casted onto the PLL/SPCE. Tyrosinase (Ty) enzyme was immobilized onto the modified Fe3O4?CH/PLL/SPCE and the electrode was coated with Nafion to fabricate the Ty/Fe3O4?CH/PLL/SPCE. Different techniques including scanning electron microscopy, chronoamperometry (i–t curve), cyclic voltammetry and electrochemical impedance spectroscopy were utilized to study the fabrication processes, electrochemical characteristics and performance parameters of the biosensor. The analytical performance of the tyramine biosensor was evaluated with respect to linear range, sensitivity, limit of detection, repeatability and reproducibility. The response of the biosensor to tyramine was linear between 4.9×10?7–6.3×10?5 M with a detection limit of 7.5×10?8 M and sensitivity of 71.36 μA mM?1 (595 μA mM?1 cm?2). The application of the developed biosensor for the determination of tyramine was successfully tested in cheese sample and mean analytical recovery of added tyramine in cheese extract was calculated as 101.2±2.1 %. The presented tyramine biosensor is a promising approach for tyramine analysis in real samples due to its high sensitivity, rapid response and easy fabrication.  相似文献   

9.
《Electroanalysis》2005,17(17):1571-1577
A novel electrochemical biosensor for phenol based on immobilization of tyrosinase‐peroxidase on mesoporous silica is described. The enhanced sensitivity of the tyrosinase‐horseradish peroxidase based biosensor to phenol was observed on comparing with tyrosinase or horseradish peroxidase monoenzyme modified electrodes. Two enzymes retained their enzymatic activities for phenol determination without any mediator. The preparation conditions of the biosensor are discussed. Optimization of the experimental parameters was performed with regard to pH and operating potential. The phenol sensor exhibited a fast response of less than 10 seconds. The sensitivity of the biosensor for phenol was 14 μA μM?1 cm?2 with a linear range from 2×10?7 to 2.3×10?4 M and a detection limit of 4.1×10?9 M. The biosensor showed a good stability and reproducibility.  相似文献   

10.
A sensor for H2O2 amperometric detection based on a Prussian blue (PB) analogue was developed. The electrocatalytic process allows the determination of hydrogen peroxide at 0.0 V with a limit of detection of 1.3 μmol L?1 in a flow injection analysis (FIA) configuration. Studies on the optimization of the FIA parameters were performed and under optimal FIA operational conditions the linear response of the method was extended up to 500 μmol L?1 hydrogen peroxide with good stability. The possibility of using the developed sensor in medium containing sodium ions and the increased operational stability constitute advantages in comparison with PB‐based amperometric sensors. The usefulness of the methodology was demonstrated by addition‐recovery experiments with rainwater samples and values were in the 98.8 to 103% range.  相似文献   

11.
For the first time silicon nitride (Si3N4) nanoparticles was used for preparation electrochemical biosensor. GOx immobilized on the Si3N4 nanoparticles exhibits facile and direct electrochemistry. The surface coverage and heterogeneous electron transfer rate constant (ks) of immobilized GOx were 6.3×10?13 mol cm?2 and 47.4±0.3 s?1. The sensitivity, linear concentration range and detection limit of the biosensor for glucose detection were 38.57 µA mM?1 cm?2, 25 µM to 8 mM and 6.5 µM, respectively. This biosensor also exhibits good stability, reproducibility and long life time. These indicate Si3N4 nanoparticles is good candidate material for construction of third generation biosensor and bioelectronics devices.  相似文献   

12.
Here we report the first mediated pain free microneedle‐based biosensor array for the continuous and simultaneous monitoring of lactate and glucose in artificial interstitial fluid (ISF). The gold surface of the microneedles has been modified by electrodeposition of Au‐multiwalled carbon nanotubes (MWCNTs) and successively by electropolymerization of the redox mediator, methylene blue (MB). Functionalization of the Au‐MWCNTs/polyMB platform with the lactate oxidase (LOX) enzyme (working electrode 1) and with the FAD‐Glucose dehydrogenase (FADGDH) enzyme (working electrode 2) enabled the continuous monitoring of lactate and glucose in the artificial ISF. The lactate biosensor exhibited a high sensitivity (797.4±38.1 μA cm?2 mM?1), a good linear range (10–100 μM) with a detection limit of 3 μM. The performance of the glucose biosensor were also good with a sensitivity of 405.2±24.1 μA cm?2 mM?1, a linear range between 0.05 and 5 mM and a detection limit of 7 μM. The biosensor array was tested to detect the amount of lactate generated after 100 minutes of cycling exercise (12 mM) and of glucose after a normal meal for a healthy patient (10 mM). The results reveal that the new microneedles‐based biosensor array seems to be a promising tool for the development of real‐time wearable devices with a variety of sport medicine and clinical care applications.  相似文献   

13.
A flow injection analysis (FIA) biosensor system was developed for the determination of the artificial sweetener aspartame (l-aspartyl-l-phenylalanine methyl ester). The system consisted of an enzyme column of pronase immobilized on activated arylamine glass beads and al-amino acid oxidase electrode connected in series. The dipeptide bond of aspartame was cleaved by immobilized pronase to release phenylalanine, which was in turn monitored by the enzyme electrode that usedl-amino acid oxidase, immobilized on a preactivated nylon membrane in combination with an amperometric electrode (platinum vs silver/silver chloride, 700 mV). The response of the FIA biosensor was linear up to 1 mM aspartame with a lower detection limit of 25 μM and had good reproducibility (rsd 0.3%). The FIA biosensor was stable for at least 30 h of continuous use atT r .Each assay takes 4 min giving a sample throughput of 15 h?1 When applied to aspartame in dietary food products the results obtained agreed well with those reported by the product manufacturers.  相似文献   

14.
A novel biosensor for hydrogen peroxide was prepared by immobilizing horseradish peroxidase (HPR) on newly synthesized dendritic silver/silicon dioxide nanocomposites, which were coated on a glassy carbon electrode. The modified electrode was characterized with XPS, SEM, and electrochemical methods. This biosensor showed a very fast amperometric response to hydrogen peroxide with a linear range from 0.7 to 120 μM, a limit of detection of 0.05 μM and a sensitivity of 1.02 mA mM?1 cm?2. The Michaelis‐Menten constant of the immobilized HRP was estimated to be 0.21 mM, indicating a high affinity of the HRP to H2O2 without loss of enzymatic activity. The preparation of the proposed biosensor was convenient, and it showed high sensitivity and good stability.  相似文献   

15.
Cholesterol oxidase biosensor has been constructed by using bovine serum albumin and glutaraldehyde as cross linker to immobilize cholesterol oxidase and cholesterol esterase on a glassy carbon electrode modified with Nafion and methyl viologen. The biosensor has been used to determine total cholesterol in blood. The linear range of the determination is 2.5×10~7 to 1.0×10-4 mol/L. The detection limit is about 5.0×10~8 mol/L. The response time is 12 s. This biosensor has the advantage of high selectivity, sensitivity and short response time.  相似文献   

16.
《Analytical letters》2012,45(12):2351-2359
Abstract

Amperometric biosensors containing enzymes butyrylcholinesterase or acetylcholinesterase were prepared. The biosensors were employed for studying of cholinesterase reactivator: HI‐6. Competitions between HI‐6 and acetylthiocholine as enzyme substrate were used for determination of IC50 value. Biosensors with butyrylcholinesterase from human serum determined IC50 as (1.00±0.02)×10?6 M; the biosensor with acetylcholinesterase from human erythrocytes performance provided IC50 (3.31±0.13)×10?6 M, the one with human recombinant acetylcholinesterase (2.00±0.06)×10?6 M and finally biosensor with acetylcholinesterase from electric eel (6.17±0.17)×10?6 M when 5 mM acetylthiocholine as substrate was used. We are encouraged to consider presented biosensors as a very useful for evaluation of newly prepared cholinesterase reactivators.  相似文献   

17.
Highly sensitive, selective, reliable and inexpensive cholesterol biosensors are highly demanded for the routine monitoring of cholesterol molecules in order to prevent heart failure incidents. In this study, Co3O4 nanostructures are synthesized using polyvinyl pyrrolidone surfactant as growth template by a low temperature aqueous chemical growth method. The morphology of nanostructures was investigated by scanning electron microscopy and X‐ray diffraction techniques. The nanostructures exhibit interconnected nanowires like morphology with interconnected network of nanowires. The nanostructures of Co3O4 are polycrystalline. The cholesterol oxidase was physically adsorbed on the interconnected nanowires of Co3O4 for the chemical sensing of cholesterol molecules. The sensor device detected a wide range of cholesterol from 1×10?7 M to 1×10?3 M concentrations with sensitivity of ?94.031 mV/decade. A detection limit of 0.035×10?7 M cholesterol concentration was observed and a fast response time of 10 s was also noticed. The fabricated device is highly stable, selective, sensitive, reproducible and repeatable. All the collected information about presented cholesterol biosensor indicates its potential application for the monitoring of cholesterol concentrations from human blood serum and real‐life samples.  相似文献   

18.
A novel nitrite biosensor was constructed by simultaneous immobilization of hemoglobin (Hb) and a room temperature ionic liquid, octylpyridinium chloride ([OcPy][Cl]), on multi-walled carbon ionic liquid electrode (MWILE). The direct electron transfer of Hb showed a pair of redox peaks with a formal potential of ?0.187 V vs. Ag/AgCl in pH 5.0 acetate buffer solution. Nitrite (NO2 ?) catalysis on the modified electrode was investigated by cyclic voltammetry and amperometry. The biosensor exhibited a wide linear range for NO2 ? detection from 0.01 to 15 mM, with a detection limit (3σ) of 1.46 μM. MWILE provided an excellent matrix for protein immobilization and biosensor fabrication which could be used for the determination of NO2 ? with a low detection limit, fast response, long linearity, and excellent sensitivity.  相似文献   

19.
A comparison of the analytical characteristics of two tyramine biosensors, based on graphene oxide (GRO) and polyvinylferrocene (PVF) modified screen‐printed carbon electrodes (SPCE), is reported. Diamine oxidase (DAOx) or monoamine oxidase (MAOx) was immobilized onto the PVF/GRO modified SPCE to fabricate the biosensors. Surface characteristics and electrochemical behaviour of the modified SPCEs were investigated by atomic force microscopy (AFM), scanning electron microscopy (SEM), energy dispersive X‐ray spectroscopy (EDX) and cyclic voltammetry (CV). Electrode surface composition and experimental variables such as pH and working potential were optimized in order to ensure a high performance. Under optimum experimental conditions, both DAOx/PVF/GRO/SPCE and MAOx/PVF/GRO/SPCE biosensors exhibited wide linear dynamic ranges for tyramine from 9.9×10?7 to 1.2×10?4 M and from 9.9×10?7 to 1.1×10?4 M, respectively. MAOx/PVF/GRO/SPCE biosensor showed higher sensitivity (11.98 μA mM?1) for tyramine determination than the DAOx/PVF/GRO/SPCE biosensor (7.99 μA mM?1). The substrate specifity of the biosensors to other biogenic amines namely histamine, putrescine, spermine, spermidine, tryptamine, β‐phenylethylamine and cadaverine was also investigated. The developed biosensors were successfully used for tyramine determination in cheese sample.  相似文献   

20.
This work presents a sol‐gel based biosensor for atrazine determination which has been obtained by introducing the enzyme polyphenol oxidase from apple tissue in a sol‐gel matrix. Apple tissue acts as a molecular recognition element. Atrazine is an inactive compound electrochemically; redox coupling of dopamine was used for studying atrazine behavior. Atrazine was determined by monitoring the inhibition power of polyphenol oxidase activity. The measurements were performed in 0.1 M KH2PO4‐NaOH buffer (pH 7.5). The effect of various experimental parameters such as pH, concentration of buffer, concentration of dopamine, incubation time and matrix composition has been investigated for optimum analytical performance. The biosensor consisted of 10.3% (w/w) of apple tissue. The bioelectrode exhibits a linear response for dopamine and atrazine concentrations in the range of 5.66 × 10?6?2.27 × 10?3M and 1 × 10?5 ?1 × 10?4 M with a detection limit of 4.2 × 10?6 and 5.5 × 10?6 M, respectively. A correlation coefficient of 0.9945 and a relative standard deviation (R.S.D.) of 3.29% for dopamine, 0.9944 and 3.69% for a trazine were achieved.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏