首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 264 毫秒
1.
A collaborative study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatography (LC) method for determination of aflatoxin B, in a milk powder based infant formula at a possible future European regulatory limit (0.1 ng/g). The test portion was extracted with methanol-water (8 + 2 [v + v]), filtered, diluted with water, and applied to an immunoaffinity column. The column was washed with water to remove interfering compounds, and the purified aflatoxin B1 was eluted with methanol. The separation and determination of the aflatoxin B1 was performed by reversed-phase LC and detected by fluorescence after postcolumn derivatization (PCD) involving bromination. PCD was achieved with either pyridinum hydrobromide perbromide (PBPB) or an electrochemical (Kobra) cell by addition of bromide to the mobile phase. The baby food (infant formula) test samples, both spiked and naturally contaminated with aflatoxin B1, were sent to 14 laboratories in 13 different European countries. Test portions were spiked at levels of 0.1 and 0.2 ng/g for aflatoxin B1. Recoveries ranged from 101 to 92%. Based on results for spiked test samples (blind pairs at 2 levels) and naturally contaminated test samples (blind pairs at 3 levels), the relative standard deviation for repeatability (RSDr) ranged from 3.5 to 14%. The relative standard deviation for reproducibility (RSDR) ranged from 9 to 23%. Nine participants used PBPB derivatization, and  相似文献   

2.
An interlaboratory study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatography (LC) method for the determination of aflatoxin B1 levels in corn samples, enforced by European Union legislation. A test portion was extracted with methanol-water (80 + 20); the extract was filtered, diluted with phosphate-buffered saline solution, filtered on a microfiber glass filter, and applied to an immunoaffinity column. The column was washed with deionized water to remove interfering compounds, and the purified aflatoxin B1 was eluted with methanol. Aflatoxin B1 was separated and determined by reversed-phase LC with fluorescence detection after either pre- or postcolumn derivatization. Precolumn derivatization was achieved by generating the trifluoroacetic acid derivative, used by 8 laboratories. The postcolumn derivatization was achieved either with pyridinium hydrobromide perbromide, used by 16 laboratories, or with an electrochemical cell by the addition of bromide to the mobile phase, used by 5 laboratories. The derivatization techniques used were not significantly different when compared by the Student's t-test; the method was statistically evaluated for all the laboratories. Five corn sample materials, both spiked and naturally contaminated, were sent to 29 laboratories (22 Italian and 7 European). Test portions were spiked with aflatoxin B1 at levels of 2.00 and 5.00 ng/g. The mean values for recovery were 82% for the low level and 84% for the high contamination level. Based on results for spiked samples (blind pairs at 2 levels) as well as naturally contaminated samples (blind pairs at 3 levels), the values for relative standard deviation for repeatability (RSDr) ranged from 9.9 to 28.7%. The values for relative standard deviation for reproducibility (RSDR) ranged from 18.6 to 36.8%. The method demonstrated acceptable within- and between-laboratory precision for this matrix, as evidenced by the HorRat values.  相似文献   

3.
An interlaboratory study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatography (LC) method for determination of aflatoxin B1 and total aflatoxins in hazelnut paste at European regulatory limits. The test portion was extracted with methanol-water (6 + 4). The extract was filtered, diluted with phosphate-buffered saline (PBS) solution to a specified solvent concentration, and applied to an immunoaffinity column containing antibodies specific to aflatoxins. The aflatoxins were removed from the immunoaffinity column with methanol, and then quantified by reversed-phase LC with post-column derivatization (PCD) involving bromination. The PCD was achieved with electrochemically generated bromine (Kobra Cell) followed by fluorescence detection (except for one participant who used pyridinum hydrobromide perbromide for bromination). Hazelnut paste, both naturally contaminated with aflatoxins and blank (<0.1 ng/g) for spiking by participants with aflatoxins, was sent to 14 collaborators in Belgium, The Netherlands, Spain, Turkey, the United Kingdom, and the United States. Test portions were spiked at levels of 4.0 and 10.0 ng/g for total aflatoxins by participants using supplied total aflatoxins standards. Recoveries for total aflatoxins and aflatoxin B1 averaged from 86 to 89%. Based on results for naturally contaminated samples (blind duplicates at 3 levels ranging from 4.0 to 11.8 ng/g total aflatoxins), the relative standard deviation for repeatability (RSDr) ranged from 2.3 to 3.4% for total aflatoxins and from 2.2 to 3.2% for aflatoxin B1. The relative standard deviation for reproducibility (RSD(R)) ranged from 6.1 to 7.0% for total aflatoxins and from 7.3 to 7.8% for aflatoxin B1. The method showed exceptionally good within-laboratory and between-laboratory precision for hazelnut paste, as evidenced by HORRAT values, which in all cases were significantly below target levels, the low levels of determination for both aflatoxin B1 and total aflatoxins.  相似文献   

4.
A collaborative study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatography (LC) method for the determination of aflatoxin B1 and total aflatoxins at European regulatory limits. The test portion is extracted with methanol-water (8 + 2) for dried figs and paprika, and with methanol-water (8 + 2) plus hexane (or cyclohexane) for peanut butter and pistachios. The sample extract is filtered, diluted with phosphate buffer saline, and applied to an immunoaffinity column. The column is washed with water and the aflatoxins are eluted with methanol. Aflatoxins are quantitated by reversed-phase LC with post-column derivatization (PCD) involving bromination. PCD is achieved with either an electrochemical cell (Kobra cell) and addition of bromide to the mobile phase or pyridinium hydrobromide perbromide. Determination is by fluorescence. Peanut butter, pistachio paste, dried fig paste, and paprika powder samples, both naturally contaminated with aflatoxins and containing added aflatoxins, were sent to 16 collaborators in 16 European countries. Test portions of samples were spiked at levels of 2.4 and 9.6 ng/g for total aflatoxins which included 1.0 and 4.0 ng/g aflatoxin B1, respectively. Recoveries for total aflatoxins ranged from 71 to 92% with corresponding recoveries for aflatoxin B1 of 82 to 109%. Based on results for spiked samples (blind duplicates at 2 levels) as well as naturally contaminated samples (blind duplicates at 4 levels, including blank), the relative standard deviation for repeatability ranged from 4.6 to 23.3% for total aflatoxins and from 3.1 to 20.0% for aflatoxin B1. The relative standard deviation for reproducibility ranged from 14.1 to 34.2% for total aflatoxins, and from 9.1 to 32.2% for aflatoxin B1. The method showed acceptable within-laboratory and between-laboratory precision for all 4 matrixes, as evidenced by HORRAT values <1, at the low levels of determination for both total aflatoxins and aflatoxin B1.  相似文献   

5.
An interlaboratory study funded by the European Commission, Standards, Measurement and Testing Programme (4th Framework Programme) was performed to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatographic (LC) method for the determination of ochratoxin A in baby food at a possible future European regulatory limit (0.1 ng/g). The test portion is extracted in a blender with tert-butyl methyl ether (chosen to avoid use of chloroform but shown to give equivalent extraction efficiency) after addition of 0.5 mol/L phosphoric acid-2 mol/L sodium chloride solution. The extract is centrifuged and redissolved in a mixture of phosphate buffered saline solution and methanol. After removal of lypophilic substances with hexane, the extract is applied to an immunoaffinity column containing antibodies specific to ochratoxin A. The column is washed with water to remove the interfering compounds and the purified ochratoxin A is eluted with methanol. The separation and determination of ochratoxin A is performed by reversed-phase LC and detected by fluorescence after postcolumn derivatization (PCD) with ammonia. Test materials (baby food infant formulae), both spiked and naturally contaminated with ochratoxin A, were sent to 13 laboratories in 8 different European countries. Test portions were spiked at a level of 0.085 ng/g ochratoxin A. The average recovery for the spiked blank baby food was 108%. Based on results for spiked samples (blind pairs at 0.085 ng/g) as well as naturally contaminated samples (blind pairs at levels between 0.05 and 0.22 ng/g) the relative standard deviation for repeatability (RSDr) ranged from 18-36%. The relative standard deviation for reproducibility (RSDR) ranged from 29-63% and HORRAT values of between 0.4 and 0.9 were obtained.  相似文献   

6.
A single-laboratory validation was conducted to establish the effectiveness of an immunoaffinity column cleanup procedure followed by LC with fluorescence detection for the determination of aflatoxins B1, B2, G1, and G2 in sesame seeds. The sample is homogenized with 50% water (w/w) to form a slurry, then the test portion is extracted with methanol-water (60 + 40, v/v) using a high-speed blender. The sample extract is filtered, diluted with 15% Tween 20 in phosphate-buffered saline solution, and applied to an immunoaffinity column. Aflatoxins are removed with neat methanol, then directly determined by RP-LC with fluorescence detection using postcolumn bromination (Kobra cell). Test portions of blank white sesame seed slurry were spiked with a mixture of aflatoxins to give total levels of 4 and 10 microg/kg. Recoveries for individual and total aflatoxins ranged from 92.7 to 110.3% for spiked samples. Based on results for spiked sesame paste (triplicates at two levels), the RSD for repeatability (RSD(r)) averaged 1.1% for total aflatoxins and 1.4% for aflatoxin B1. The method was demonstrated to be applicable to naturally contaminated samples of black and white sesame seeds obtained from local markets in China.  相似文献   

7.
A collaborative study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatographic method for determination of aflatoxin M1 in milk at proposed European regulatory limits. The test portion of liquid milk was centrifuged, filtered, and applied to an immunoaffinity column. The column was washed with water, and aflatoxin was eluted with pure acetonitrile. Aflatoxin M1 was separated by reversed-phase liquid chromatography (LC) with fluorescence detection. Frozen liquid milk samples both naturally contaminated with aflatoxin M1 and blank samples for spiking, were sent to 12 collaborators in 12 different European countries. Test portions of samples were spiked at 0.05 ng aflatoxin M1 per mL. After removal of 2 noncompliant sets of results, the mean recovery of aflatoxin M1 was 74%. Based on results for spiked samples (blind pairs at 1 level) and naturally contaminated samples (blind pairs at 3 levels) the relative standard deviation for repeatability (RSDr) ranged from 8 to 18%. The relative standard deviation for reproducibility (RSDR) ranged from 21 to 31%. The method showed acceptable within- and between-laboratory precision data for liquid milk, as evidenced by HORRAT values at the low level of aflatoxin M1 contamination.  相似文献   

8.
建立婴幼儿营养米粉中黄曲霉毒素B1的高效液相色谱荧光检测器测定方法。样品以甲醇–水(体积比70∶30)溶液匀质提取,过黄曲霉毒素B1免疫层析亲和柱净化,经CNW Athena C18色谱柱分离和光化学柱后衍生反应器衍生后,用带有荧光检测器的高效液相色谱仪测定。采用峰面积外标法定量黄曲霉毒素B1含量。黄曲霉毒素B1在0~10μg/L的浓度范围内线性关系良好,相关系数为0.999 8,检出限为0.25μg/kg。在3个添加水平下加标回收率为97.7%~106.9%,测定结果的相对标准偏差为1.7%(n=6)。该方法的灵敏度、准确度、精密度均符合黄曲霉毒素B1的检测技术要求,适用于婴幼儿营养米粉中黄曲霉毒素B1的日常检测。  相似文献   

9.
A collaborative study was conducted to evaluate a liquid chromatographic (LC) method with immunoaffinity column cleanup for determination of ochratoxin A. The method was tested at 3 concentration levels of ochratoxin A in barley, which represent possible future European regulatory limits. The test portion was extracted with acetonitrile-water by blending at high speed. The extract was filtered, diluted with phosphate-buffered saline (PBS), and applied to an ochratoxin A immunoaffinity column. The column was washed with water and the ochratoxin A eluted with methanol. The solvent was then evaporated and the residue redissolved in injection solvent. After injection of this solution onto reversed-phase LC column, ochratoxin A was measured by fluorescence detection. Eight samples of low level naturally contaminated barley and 2 samples of blank barley (ochratoxin A not found at the limit of detection of 0.2 microg/kg at the signal-to-noise ratio of 3 to 1) were sent, along with ampules of ochratoxin A, calibrant, and spiking solutions, to 15 laboratories in 13 different European countries. Test portions were spiked with ochratoxin A at levels of 4 ng/g, and recoveries ranged from 65 to 113%. Based on results for spiked samples (blind duplicates) and naturally contaminated samples (blind duplicates at 3 levels), the relative standard deviation for repeatability (RSDr) ranged from 4 to 24%, and the relative standard deviation for reproducibility (RSDR) ranged from 12 to 33%. The method showed acceptable within- and between-laboratory precision, as evidenced by HORRAT values, at the low level of determination for ochratoxin A in barley.  相似文献   

10.
采用免疫亲和层析柱吸附食品样品中的黄曲霉毒素B1,以荧光色谱-柱后光化学衍生法测定食品中黄曲霉毒素B1的含量。样品用甲醇-水溶液(体积比为7:3)混合,均质器高速搅拌提取,经免疫亲和层析柱纯化后,通过LachromC18色谱柱进行分离,以甲醇一水溶液(体积比为45:55)作为流动相,荧光检测器激发波长为360nm、发射波长为420nm,外标法定量。黄曲霉毒素B,的质量浓度在1~20ng/mL范围内与色谱峰面积线性关系良好,相关系数r=0.9998,检出限为0.1gg/kg。在3个添加水平下,样品的加标回收率在88.5%~97.9%之间,相对标准偏差均小于3%(n=6)。该方法操作简单、定量准确,可用于食品中黄曲霉毒素B.的定量定性检验。  相似文献   

11.
A collaborative study was conducted to evaluate a liquid chromatography (LC) method for ochratoxin A using sequential phenyl silane and immunoaffinity column cleanup. The method was tested at 3 different levels of ochratoxin A in roasted coffee, which spanned the range of possible future European regulatory limits. The test portion was extracted with methanol and sodium bicarbonate by shaking for 30 min. The extract was filtered, centrifuged, and then cleaned up on a phenyl silane column before being eluted from the washed column with methanol-water. The eluate was diluted with phosphate-buffered saline (PBS) and applied to an ochratoxin A immunoaffinity column, which was washed with water. The ochratoxin A was eluted with methanol, the solvent was evaporated, and the residue was redissolved in injection solvent. After injection of this solution onto a reversed-phase LC apparatus, ochratoxin A was measured by fluorescence detection. Eight laboratory samples of low-level naturally contaminated roasted coffee and 2 laboratory samples of blank coffee (< 0.2 ng/g ochratoxin A at the signal-to-noise ratio of 3:1), along with ampules of ochratoxin A calibrant and spiking solutions, were sent to 15 laboratories in 13 different European countries. Test portions of the laboratory samples were spiked at levels of 4 ng/g ochratoxin A, and recoveries ranged from 65 to 97%. Based on results for spiked blank material (blind duplicates) and naturally contaminated material (blind duplicates at 3 levels), the relative standard deviation for repeatability (RSDr) ranged from 2 to 22% and the relative standard deviation for reproducibility (RSDR) ranged from 14 to 26%. The method showed acceptable within- and between-laboratory precision, as evidenced by HORRAT values, at the low level of determination for ochratoxin A in roasted coffee.  相似文献   

12.
This study compared 2 post-column derivatization (PCD) techniques for the determination of aflatoxins B1, B2, G1, and G2 (AFB1, AFB2, AFG1, and AFG2) by fluorescence detection after liquid chromatographic separation: ultraviolet (UV) irradiation (PCD(UV)) and electrochemical bromination (PCD(EC)). Photochemical fluorescence enhancement was obtained with 2 different commercially available systems (PCD(UV1) and PCD(UV2)). An electrochemical bromination apparatus was used for bromination. Analyses of naturally contaminated or spiked samples of corn, pistachio paste, peanut butter, fig paste, and animal feed showed that neither of the techniques resulted in derivatization-specific matrix interferences for any of the matrixes under study, even when extracts were not completely purified. The response ratios PCD(UV)/PCD(EC) for AFB1, AFB2, AFG1, and AFG2 were 0.86, 0.96, 0.70, and 0.96, respectively, for PCD(UV1) and 0.82, 0.95, 0.60, and 0.90, respectively, for PCD(UV2). The long-term use of the UV lamps (300 h for PCD(UV1) and 343 h for PCD(UV2)) in the photochemical detectors showed that these ratios remained stable throughout the time frame investigated. The relative standard deviation obtained for each of the devices during the in-house validation study ranged from 0.3 to 1.8% for PCD(UV1), from 0.8 to 1.3% for PCD(UV2), and from 0.9 to 2.0% for PCD(EC).  相似文献   

13.
A method was developed for the determination of aflatoxin B1 in medical herbs (senna pods, botanical name Cassia angustifolia; devil's claw, botanical name Harpagophytum procumbens; and ginger roots, botanical name Zingiber officinale). The method, which was tested in a mini-collaborative study by 4 laboratories, is based on an immunoaffinity cleanup followed by reversed-phase high-performance liquid chromatography separation and fluorescence detection after post-column derivatization. It allows the quantitation of aflatoxin B1 at levels lower than 2 ng/g. A second extractant (acetone-water) was tested and compared to the proposed methanol-water extractant. Several post-column derivatization options (electrochemically generated bromine, photochemical reaction, and chemical bromination) as well as different integration modes (height versus area) were also investigated. No differences were found depending on the choice of derivatization system or the signal integration mode used. The method was tested for 3 different matrixes: senna pods, ginger root, and devil's claw. Performance characteristics were established from the results of the study and resulted in HorRat values ranging from 0.12 to 0.75 with mean recoveries from 78 to 91% for the extraction with methanol-water and HorRat values ranging from 0.10-1.03 with mean recoveries from 98 to 103% for the extraction with acetone-water. As a result, the method, with all tested variations, was found to be fit-for-purpose for the determination of aflatoxin B1 in medical herbs at levels of 1 microg/kg and above.  相似文献   

14.
张鹏  张艺兵  赵卫东  李寅宾 《色谱》2000,18(1):82-84
 采用免疫亲和柱净化、在线电化学衍生化高效液相色谱法测定了花生中黄曲霉毒素(AFT)B 1,B2,G1和G2。以体积分数为80%的甲醇提取样品中的AFT,经免疫亲和柱净化洗脱 后,以Kobra Cell装置在线衍生,反相HPLC分离定量。4种毒素的分离在13 min内完成,检 出限均达到0.1 μg/kg。5次测定花生样品的RSD值为9.2%~15%;样品添加标样0.5 ~9.0 μg/kg,回收率为74.8%~97.3%。  相似文献   

15.
A liquid chromatographic method for the determination of fumonisins B1 (FB1) and B2 (FB2) in corn-based foods for infants and young children was subjected to an interlaboratory validation study involving 11 laboratories. Five blind duplicate sample pairs of each matrix were analyzed to establish the accuracy, repeatability, and reproducibility of the method. Mass fractions in the baby food samples ranged from 89.1 to 384.4 microg/kg FB1 and from 22.5 to 73.6 microg/kg FB2. The method involved a warm extraction with citrate phosphate buffer-methanol-acetonitrile (50 + 25 + 25, v/v/v), a cleanup through an immunoaffinity column, and an end-determination of fumonisins by LC after automated precolumn derivatization with o-phthaldialdehyde reagent. RSDs for within-laboratory repeatability (RSDr) ranged from 6.8 to 23.5% for FB1 and 7.6 to 22.9% for FB2. RSDs for between-laboratory reproducibility (RSDR) ranged from 15.4 to 26.2% for FB1 and 21.6 to 36.3% for FB2. Mean FB1 recoveries from baby foods spiked at 100.0 and 250.0 microg/kg were 89 and 96%, respectively; for FB2 spiked foods at 25.0 and 62.5 microg/kg recoveries were 90 and 85%, respectively. HorRat values ranged from 0.8 to 1.2 for FB1, whereas for FB2 they ranged from 0.9 to 1.4 when calculated according to Horwitz, and from 1.0 to 1.7 when calculated according to Thompson, indicating an acceptable among-laboratory precision for all matrixes (HorRat values <2).  相似文献   

16.
The accuracy, repeatability, and reproducibility characteristics of a method using multitoxin immunoaffinity column cleanup with liquid chromatography (LC) for determination of aflatoxins (AF; sum of aflatoxins B1, B2, G1, and G2) and ochratoxin A (OTA) in powdered ginseng and ginger have been established in a collaborative study involving 13 laboratories from 7 countries. Blind duplicate samples of blank, spiked (AF and OTA added) at levels ranging from 0.25 to 16.0 microg/kg for AF and 0.25 to 8.0 microg/kg for OTA were analyzed. A naturally contaminated powdered ginger sample was also included. Test samples were extracted with methanol and 0.5% aqueous sodium hydrogen carbonate solution (700 + 300, v/v). The extract was centrifuged, diluted with phosphate buffer (PB), filtered, and applied to an immunoaffinity column containing antibodies specific for AF and OTA. After washing the column with water, the toxins were eluted from the column with methanol, and quantified by high-performance LC with fluorescence detection. Average recoveries of AF from ginseng and ginger ranged from 70 to 87% (at spiking levels ranging from 2 to 16 microg/kg), and of OTA, from 86 to 113% (at spiking levels ranging from 1 to 8 microg/kg). Relative standard deviations for within-laboratory repeatability (RSDr) ranged from 2.6 to 8.3% for AF, and from 2.5 to 10.7% for OTA. Relative standard deviations for between-laboratory reproducibility (RSDR) ranged from 5.7 to 28.6% for AF, and from 5.5 to 10.7% for OTA. HorRat values were < or = 2 for the multi-analytes in the 2 matrixes.  相似文献   

17.
A single-laboratory method validation was conducted to establish the effectiveness of an immunoaffinity column cleanup procedure followed by liquid chromatography/mass spectrometry (LCIMS) for the determination of fumonisins B1 and B2 (FBI + FB2) in corn. The test portion is extracted with acetonitrile-methanol-water (25 + 25 + 50). The extract is filtered, diluted with phosphate-buffered saline solution, and applied to an immunoaffinity column. FB1 + FB2 are removed with methanol and directly determined by reversed-phase LC with MS detection using selected-ion monitoring of 2 characteristic ions in each case. Test portions of blank corn samples were spiked with a mixture of FB1 + FB2 to give total levels of 200 and 500 ng/g, respectively. Recoveries of both FB1 and FB2 from spiked samples averaged 90.4-101%. Based on results for spiked raw corn (triplicates at 2 levels), the relative standard deviation for repeatability ranged from 2.8 to 7.1%. The accuracy of the method was demonstrated by analysis of Food Analysis Performance Assessment Scheme (FAPAS) test material. The method was also applied to a small survey of processed corn products such as corn chips, cornflakes, and popcorn.  相似文献   

18.
李军  于一茫  田苗  王宏伟  卫锋  李莉  王雄 《色谱》2006,24(6):581-584
建立了同时检测粮谷中黄曲霉毒素(B1、B2、G1和G2)、玉米赤霉烯酮和赭曲霉毒素A的免疫亲和柱净化-柱后光化学衍生-高效液相色谱方法。样品经过甲醇-水(体积比为80∶20)提取,通过免疫亲和柱富集和净化,采用Waters Nova-Pak色谱柱(3.9 mm i.d.×150 mm,4 μm),以甲醇、乙腈和1%的磷酸溶液为流动相,梯度洗脱,柱后光化学衍生、改变波长荧光检测。黄曲霉毒素(B1、B2、G1和G2)、玉米赤霉烯酮和赭曲霉毒素A检出限分别为0.24,4.0和0.5 μg/kg,标准曲线的线性范围分别为0.24~6.0,4.0~100.0和0.5~40.0 μg/L;在小麦、玉米、黑麦样品中,平均加标回收率为70.8% ~94.0%,相对标准偏差为2.79% ~9.38%。  相似文献   

19.
An interlaboratory trial for determination of zearalenone (ZON) in baby food and animal feed was conducted. The study involved 39 participants in 16 European Union member states, as well as Turkey, Uruguay, and China, representing a cross-section of industry, and official food control and research institutes. The method is based on immunoaffinity column cleanup followed by high-performance liquid chromatography using fluorimetry (HPLC-FI). The test portion of the sample is extracted with methanol-water (75 + 25, v/v). The sample extract is filtered, diluted, and passed over an immunoaffinity column. ZON is eluted with methanol. The separation and determination of ZON is performed by reversed-phase HPLC-FI with an excitation wavelength of 274 nm and an emission wavelength of 446 nm. Test portions of the samples were spiked at levels of 20 and 30 microg/kg ZON in baby food and at levels of 100 and 150 microg/kg ZON in animal feed. Mean recoveries from each participant ranged from 78 to 119% with an average value of 92% for baby food and from 51 to 122% with an average value of 74% for animal feed. Based on results for spiked samples (blind duplicates at 2 levels), as well as naturally contaminated samples (blind duplicates at 3 levels), the relative standard deviation for repeatability (RSDr) in baby food ranged from 2.8 to 9.0%. For animal feed, this value ranged from 5.7 to 9.5%. The relative standard deviation for reproducibility (RSDR) in baby food ranged from 8.2 to 13.3%, and for animal feed this value ranged from 15.5 to 21.4%. The Horwitz ratio (HorRat) in baby food ranged from 0.3 to 0.4, and for animal feed this value ranged from 0.6 to 0.9. The method showed acceptable within- and between-laboratory precision for each matrix, as required by European legislation.  相似文献   

20.
A liquid chromatographic (LC) method for the determination of fumonisins B1 (FB1) and B2 (FB2) in corn and corn flakes was collaboratively studied by 23 laboratories, which analyzed 5 blind duplicate pairs of each matrix to establish the accuracy, repeatability, and reproducibility characteristics of the method. Fumonisin levels in the corn ranged from <0.05 (blank) to 1.41 microg/g for FB1 and from <0.05 to 0.56 microg/g for FB2, whereas in the corn flakes they ranged from <0.05 to 1.05 microg/g for FB1 and from <0.05 to 0.46 microg/g for FB2. The method involved double extraction with acetonitrile-methanol-water (25 + 25 + 50), cleanup through an immunoaffinity column, and LC determination of the fumonisins after derivatization with o-phthaldialdehyde. Relative standard deviations for the within-laboratory repeatability (RSDr) of the corn analyses ranged from 19 to 24% for FB1 and from 19 to 27% for FB2; for the corn flakes analyses, RSDr ranged from 9 to 21 % for FB1 and from 8 to 22% for FB2. Relative standard deviations for the between-laboratories reproducibility (RSDR) of the corn analyses ranged from 22 to 28% for FB1 and from 22 to 30% for the FB2; for corn flakes analyses, RSDR ranged from 27 to 32% for FB1 and from 26 to 35% for FB2. Mean recoveries of FB1 and FB2 from corn spiked with FB1 at 0.80 microg/g and with FB2 at 0.40 microg/g were 76 and 72%, respectively; for corn flakes spiked at the same levels recoveries were 110 and 97% for FB1 and FB2, respectively. HORRAT ratios for the analyses of corn ranged from 1.44 to 1.53 for FB1 and from 0.96 to 1.48 for FB2, whereas for corn flakes they ranged from 1.60 to 1.82 for FB1 and from 1.39 to 1.68 for FB2.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏