首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到17条相似文献,搜索用时 234 毫秒
1.
In this paper Micromegas has been designed to detect neutrons. The simulation of the spatial resolution of Micromegas as neutron detector is carried out by GEANT4 toolkit. The neutron track reconstruction method based on the time coincidence technology is employed in the present work. The influence of the flux of incident 14 MeV neutron and high gamma background on the spatial resolution is carefully studied. Our results show that the spatial resolution of the detector is sensitive to the neutron flux, but insensitive to the intensity of γ background if the neutron track reconstruction method proposed by our group is used. The γ insensitivity makes it possible for us to use the Micromegas detector under condition which has high γ-rays background.  相似文献   

2.
In this paper a two dimensional readout micromegas detector with a polyethylene foil as converter was simulated on GEANT4 toolkit and GARFIELD for fast neutron detection. A new track reconstruction method based on time coincidence technology was developed in the simulation to obtain the incident neutron position. The results showed that with this reconstruction method higher spatial resolution was achieved.  相似文献   

3.
To reduce the discharge of the standard bulk Micromegas and GEM detectors, a GEM-Micromegas detector was developed at the Institute of High Energy Physics. Taking into account the advantages of the two detectors, one GEM foil was set as a preamplifier on the mesh of Micromegas in the structure and the CEM pream- plification decreased the working voltage of Micromegas to significantly reduce the effect of the discharge. At the same gain, the spark probability of the GEM-Micromegas detector can be reduced to a factor 0.01 compared to the standard Micromegas detector, and an even higher gain could be obtained. This paper describes the performance of the X-ray beam detector that was studied at 1W2B Laboratory of Beijing Synchrotron Radiation Facility. Finally, the result of the energy resolution under various X-ray energies was given in different working gases. This indicates that the GEM-Micromegas detector has an energy response capability in an energy range from 6 keV to 20 keV and it could work better than the standard bulk-Micromegas.  相似文献   

4.
To reduce the discharge of the standard bulk Micromegas and GEM detectors, a GEM-Micromegas detector was developed at the Institute of High Energy Physics. Taking into account the advantages of the two detectors, one GEM foil was set as a preamplifier on the mesh of Micromegas in the structure and the GEM preamplification decreased the working voltage of Micromegas to significantly reduce the effect of the discharge. At the same gain, the spark probability of the GEM-Micromegas detector can be reduced to a factor 0.01 compared to the standard Micromegas detector, and an even higher gain could be obtained. This paper describes the performance of the X-ray beam detector that was studied at 1W2B Laboratory of Beijing Synchrotron Radiation Facility. Finally, the result of the energy resolution under various X-ray energies was given in different working gases. This indicates that the GEM-Micromegas detector has an energy response capability in an energy range from 6 keV to 20 keV and it could work better than the standard bulk-Micromegas.  相似文献   

5.
介绍了一种双维位置灵敏CsI(Tl)闪烁探测器, 利用GEANT4对它进行了蒙特卡罗模拟, 得到了RIB 17N的位置分布谱及探测器的空间位置分辨, 模拟结果与实验测量值很好地吻合。给出了影响探测器分辨的主要因素及改进方案。A two dimensional position sensitive CsI(Tl) scintillation detector readout with PSPMT was introduced. The performance of detector was simulated by using Monte Carlo code GEANT4. The position spectrum of RIB 17N and the detector’s position resolution were obtained, and the simulation results accorded with the experimental ones. The main factors, which can affect performance of the detector, and some planned detector improvements were presented.  相似文献   

6.
随着国内高通量中子源及中子散射谱仪的快速发展,对高探测效率、高位置分辨、低伽玛灵敏度的位置灵敏型热中子探测器需求日益迫切。目前国际上中子散射谱仪大多数采用了基于3He的热中子探测器,由于当前3He价格昂贵,寻求3He替代型热中子探测器的相关研究任务紧迫。提出了一种基于10B4C转换体的多层多丝正比室新型二维位置灵敏型热中子探测器,并利用蒙特卡罗模拟软件Geant4和Garfield++对其探测效率、位置分辨、n/γ抑制比等性能展开了详细的模拟研究。结果表明,当多丝正比室单元为40层,阈值为200 keV时,热中子(E=0.025 eV)探测效率可达到~54%,位置分辨为2.6 mm (FWHM),n/γ抑制比为~107,可以满足大多数中子散射谱仪的需求,为此类探测器设计及实验研究提供了理论依据。As the development of high flux neutron sources and neutron scattering spectrometers in China, more and more neutron detectors with high detection efficiency, high position resolution, high time resolution and low gamma sensitivity are need ungently. 3He based neutron detector is one of the best options. Recently, because of the 3He gas shortage and its expensive price, we must find a new replacement of 3He. A two-dimensional position sensitive neutron detector based on multi-layer Multi Wires Proportional Chambers (mMWPC) with 10B4C converter was proposed in this paper. The neutron detection efficiency, position resolution and γ compression were simulated with Geant4 and Garfield++. The results show that with 40 layers of neutron convertor, high themal neutron (E=0.025 eV) detection of~54%, best position resolution of 2.6 mm (FWHM) and high n/γ rejection ratio of~107 with the threshold of 200 keV can be achieved, which can meet the requirements of most spectrometers. This simulation results lay a good foundation for the next step of detector construction and test.  相似文献   

7.
在培育新品种过程中能够实时掌握了解土壤中植物根系的形态以及其生长情况将为植物学家提供很多不可或缺的信息。对基于 micromegas 探测技术的中子 CT 在这一新应用的试验环境进行了仿真模拟, 通过三维图像重建后,得到了令人满意的预期结果。首先通过 Geant4 和 Garfield 模拟计算利用聚乙烯薄膜作为中子转换层的 micromegas 中子探测器, 得到了非常理想的位置分辨, 说明基于micromegas 探测技术建立中子 CT 照相系统的可行性。 然后利用MCNP仿真模拟14 MeV 中子CT 的实验环境, 最后由Matlab程序进行图像重建。In this paper, the possibility using micromegas(Micro Mesh Gaseous Structure) as neutron detector in 14 MeV neutron computed tomography(CT) has been simulated. The results show that the micromegas neutron detector has high spatial resolution and is a good candidate for neutron radiography. The three dimensional images of plant roots in soil are successfully and clearly obtained by the 14 MeV neutron CT with micromegas as a neutron detector. In the present simulation, MCNP is employed for 14 MeV neutron transport in the sample and Matlab for the 3 D photograph reconstruction.  相似文献   

8.
随着脉冲强流中子源的发展,对高性能中子探测器提出了更大的挑战,3He气体资源严重短缺和高计数率中子探测器的迫切需求,已开始制约着中子源应用技术的发展。中国科学院高能物理研究所针对中子的特殊性,专门研发了一种陶瓷基材的nTHGEM(neutron Thick Gaseous Electron Multiplier)探测器用于中子探测。基于nTHGEM的中子探测器具有高计数率、高位置与时间分辨能力、增益大、制作工艺简单,且便于大面积制作的特点,是目前国际上发展替代3He探测技术的重要方向之一。为了详细研究nTHGEM探测器的本身性能,本工作使用55Fe放射源研究了nTHGEM探测器的增益、计数率稳定性、能量分辨率等关键参数与nTHGEM膜间电压、收集场强、漂移场强之间的关系,优化了nTHGEM探测器在不同工作气体中的工作参数,为后续进一步优化nTHGEM探测器设计和工艺奠定了基础。实验结果表明,单层nTHGEM探测器在Ar(90%)+CO2(10%)混合气体中增益能达到103,探测器计数率稳定性良好。另外,还在中国原子能科学研究院的CARR反应堆(China Advanced Research Reactor)上进行了中子束流实验,通过狭缝测量到探测器位置分辨率为(3.01±0.03)mm(FWHM),已经接近高气压3He MWPC中子探测器水平。With the development of pulsed intense neutron source, the high-performance neutron detector poses more challenges. The severe shortage of 3He gas resources and the urgent need of neutron detector with high counting rate have begun to restrict the neutron source application technology development. In response to the particularity of neutrons, the Institute of High Energy Physics of CAS developed a nTHGEM(neutron Thick Gaseous Electron Multiplier)of ceramic substrate for neutron detection. The neutron detector based on nTHGEM is one of the most important directions for the development of alternative 3He detection technology in the world at present because of its high counting rate, high position and time resolution, large gain, simple fabrication process and large area production. In order to study the properties of nTHGEM detector in detail, this paper studied the relationship between nTHGEM detector's gain, counting rate stability, energy resolution and other key parameters and nTHGEM film voltage, collection field strength and drift field strength using 55Fe radioactive source, Optimized the working parameters of nTHGEM detector in different working gases, which laid the foundation for further optimization of nTHGEM detector design and process. The experimental results show that the single-layer nTHGEM detector has a gain of 103 in a Ar(90%)+CO2(10%) mixed gas with good counting rate stability. In addition, a neutron beam experiment was performed on the China Advanced Research Reactor at the China Institute of Atomic Energy, and the position resolution of the detector was (3.01±0.03) mm (FWHM) measured by slits. Its performance is close to the high pressure 3He MWPC neutron detector level.  相似文献   

9.
An event-counting thermal neutron imaging detector based on 3 mol % nattGd2O3-doped micro-channel plate (MCP) has been developed and tested. A thermal neutron imaging experiment was carried out with a low flux neutron beam. Detection efficiency of 33% was achieved with only one doped MCP. The spatial resolution of 72μ m RMS is currently limited by the readout anode. A detector with larger area and improved readout method is now being developed.  相似文献   

10.
An event-counting thermal neutron imaging detector based on 3 mol%natGd2O3-doped micro-channel plate(MCP)has been developed and tested.A thermal neutron imaging experiment was carried out with a low flux neutron beam.Detection efficiency of 33%was achieved with only one doped MCP.The spatial resolution of 72μm RMS is currently limited by the readout anode.A detector with larger area and improved readout method is now being developed.  相似文献   

11.
Jianjin Zhou 《中国物理 B》2022,31(5):50702-050702
In recent years, gas electron multiplier (GEM) neutron detectors have been developing towards high spatial resolution and high dynamic counting range. We propose a novel concept of an Al stopping layer to enable the detector to achieve sub-millimeter (sub-mm) spatial resolution. The neutron conversion layer is coated with the Al stopping layer to limit the emission angle of ions into the drift region. The short track projection of ions is obtained on the signal readout board, and the detector would get good spatial resolution. The spatial resolutions of the GEM neutron detector with the Al stopping layer are simulated and optimized based on Geant4GarfieldInterface. The spatial resolution of the detector is 0.76 mm and the thermal neutron detection efficiency is about 0.01% when the Al stopping layer is 3.0 μ m thick, the drift region is 2 mm thick, the strip pitch is 600 μ m, and the digital readout is employed. Thus, the GEM neutron detector with a simple detector structure and a fast readout mode is developed to obtain a high spatial resolution and high dynamic counting range. It could be used for the direct measurement of a high-flux neutron beam, such as Bragg transmission imaging, very small-angle scattering neutron detection and neutron beam diagnostic.  相似文献   

12.
In this paper Micromegas has been designed to detect neutrons. The simulation of the spatial reso-lution of Micromegas as neutron detector is carried out by GEANT4 toolkit. The neutron track reconstruction method based on the time coincidence technology is employed in the present work. The influence of the flux of incident 14 MeV neutron and high gamma background on the spatial resolution is carefully studied. Our results show that the spatial resolution of the detector is sensitive to the neutron flux, but insensitive to the intensity of γ background if the neutron track reconstruction method proposed by our group is used. The γ insensitivity makes it possible for us to use the Micromegas detector under condition which has high γ-rays background.  相似文献   

13.
In this paper a two dimensional readout micromegas detector with a polyethylene foil as converter was simulated on GEANT4 toolkit and GARFIELD for fast neutron detection.A new track reconstruction method based on time coincidence technology was developed in the simulation to obtain the incident neutron position.The results showed that with this reconstruction method higher spatial resolution was achieved.  相似文献   

14.
LaBr3(Ce)探测器是一种新型闪烁体探测器,具有高光产额,高探测效率,高时间和空间分辨率,高能量分辨率,温度特性良好,抗辐射性能良好,操作简便等优点.从2001年以来,该探测器得到了迅速的研究和应用.LaBr3(Ce)探测器在核共振荧光检测、瞬发γ中子活化分析、爆炸物检测、核医学成像、环境辐射监测、空间辐射探测等方面的应用研究中取得了非常良好的效果.该探测器表现出优于以往用于这些领域的探测器的性能(例如NaI(Tl)探测器、BGO探测器、HPGe探测器等).介绍了LaBr3(Ce)探测器的性能及其应用研究进展,对代表性文献进行了简析和综述,阐明了其良好的应用前景.  相似文献   

15.
 中子激发发射计算机断层扫描成像对探测器有着较高的要求,为了探讨利用传统阵列探测器实现其应用的可行性,利用模拟的方法给出了锗酸铋(BGO)晶体阵列探测器的基本性能。对高能光子在单根BGO晶体中的能谱进行了分析,提出叠加相邻晶体信号以提高能量分辨率的修正方法。结果表明:此方法能够很大程度上优化输出能谱,并能够得到较好的空间分辨率。  相似文献   

16.
With new generation neutron sources, traditional neutron detectors cannot satisfy the demands of the applications, especially under high flux. Furthermore, facing the global crisis in ~3He gas supply, research on new types of neutron detector as an alternative to ~3He is a research hotspot in the field of particle detection. GEM(Gaseous Electron Multiplier) neutron detectors have high counting rate, good spatial and time resolution, and could be one future direction of the development of neutron detectors. In this paper, the physical process of neutron detection is simulated with Geant 4 code, studying the relations between thermal conversion efficiency, boron thickness and number of boron layers. Due to the special characteristics of neutron detection, we have developed a novel type of special ceramic n THGEM(neutron THick GEM) for neutron detection. The performance of the n THGEM working in different Ar/CO_2 mixtures is presented, including measurements of the gain and the count rate plateau using a copper target X-ray source. A detector with a single n THGEM has been tested for 2-D imaging using a ~(252)Cf neutron source. The key parameters of the performance of the n THGEM detector have been obtained, providing necessary experimental data as a reference for further research on this detector.  相似文献   

17.
A 2D neutron detector based on 3 He convertor and MWPC with an active area of 200 mm×200 mm has been successfully designed and fabricated.The detector has been tested with Am/Be neutron source and with collimated neutron beam with the wavelength of =1.37.The best spatial resolution of 1.18 mm(FWHM) and good linearity were obtained.This is in good agreement with theoretical calculations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号