首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   44篇
  免费   6篇
化学   33篇
力学   2篇
数学   1篇
物理学   14篇
  2022年   3篇
  2021年   1篇
  2020年   3篇
  2019年   4篇
  2018年   5篇
  2017年   4篇
  2016年   6篇
  2015年   2篇
  2014年   3篇
  2013年   3篇
  2012年   2篇
  2011年   8篇
  2010年   2篇
  2009年   1篇
  2007年   1篇
  2005年   1篇
  2004年   1篇
排序方式: 共有50条查询结果,搜索用时 234 毫秒
1.
A novel, simple, and rapid reversed‐phase vortex‐assisted liquid–liquid microextraction coupled with high‐performance liquid chromatography has been introduced for the extraction, clean‐up, and preconcentration of amygdalin in oil and kernel samples. In this technique, deionized water was used as the extracting solvent. Unlike the reversed‐phase dispersive liquid–liquid microextraction, dispersive solvent was eliminated in the proposed method. Various parameters that affected the extraction efficiency, such as extracting solvent volume and its pH, vortex, and centrifuging times were evaluated and optimized. The calibration curve shows good linearity (r2 = 0.9955) and precision (RSD < 5.2%) in the range of 0.07–20 μg/mL. The limit of detection and limit of quantitation were 0.02 and 0.07 μg/mL, respectively. The recoveries were in the range of 96.0–102.0% with relative standard deviation values ranging from 4.0 to 5.1%. Unlike the conventional extraction methods for plant extracts, no evaporative and re‐solubilizing operations were needed in the proposed technique.  相似文献   
2.
In this study, a new device for semi-automated salt-assisted liquid–liquid extraction was designed and coupled with high-performance liquid chromatography (HPLC) to determine three aromatic hydrocarbons in aqueous samples. In order to evaluate the performance of the designed device, three aromatic hydrocarbons including 2-naphthol, naphthalene and anthracene were selected as model analytes. Sample solution, extraction solvent and salt solution using separate channels were transferred to a sample holder, respectively. These three components were mixed using a magnetic stirrer. After stirrer stopping, the aqueous and organic phases were separated and organic layer transferred to the injection loop of HPLC system. Optimization process was achieved using response surface methodology by Design-Expert software. A central composite design was used to optimize the main parameters including pH (A), stirrer time (B), organic solvent volume (C) and salt concentration (D). The limit of quantitation for 2-naphthol, naphthalene and anthracene was 15.0, 25.0 and 1.0 ng mL?1, respectively. Under the optimum conditions, obtained recoveries for three analytes were in the range of 76.0–96.2% with relative standard deviation less than 8.2%. The salt-assisted liquid–liquid extraction method using the proposed device has been successfully used for the analysis of real samples containing studied analytes in various matrices.  相似文献   
3.
4.
Tungstate ions were successfully loaded onto triazine‐based ionic liquid‐functionalized magnetic nanoparticles through an anion exchange process. The use of triazine core for creating ionic liquid led to the immobilization of high amounts of WO42?. The resulting catalyst showed high activity and selectivity in the oxidation of sulfides to sulfoxides with H2O2 as a green oxidant at room temperature. In addition, due to the presence of ammonium groups in the catalyst structure, water dispersibility of the catalyst was increased. More important, the catalyst was magnetically recovered and reused for up to six runs without any marked decrease of activity and selectivity. Finally, easy gram‐scale oxidation of methylphenyl sulfide as well as fast separation of catalyst and product makes the protocol economical and industrially applicable.  相似文献   
5.
Forced convection heat transfer of non-Newtonian nanofluids in a circular tube with constant wall temperature under turbulent flow conditions was investigated experimentally. Three types of nanofluids were prepared by dispersing homogeneously γ-Al2O3, TiO2 and CuO nanoparticles into the base fluid. An aqueous solution of carboxymethyl cellulose (CMC) was used as the base fluid. Nanofluids as well as the base fluid show shear-thinning (pseudoplastic) rheological behavior. Results indicate that the convective heat transfer coefficient of nanofluids is higher than that of the base fluid. The enhancement of the convective heat transfer coefficient increases with an increase in the Peclet number and the nanoparticle concentration. The increase in the convective heat transfer coefficient of nanofluids is greater than the increase that would be observed considering strictly the increase in the effective thermal conductivity of nanofluids. Experimental data were compared to heat transfer coefficients predicted using available correlations for purely viscous non-Newtonian fluids. Results show poor agreement between experimental and predicted values. New correlation was proposed to predict successfully Nusselt numbers of non-Newtonian nanofluids as a function of Reynolds and Prandtl numbers.  相似文献   
6.
Chaperone-assisted biopolymer translocation is the main model proposed for translocation in vivo. A dynamical Monte Carlo method is used to simulate the translocation of a stiff homopolymer through a nanopore driven by chaperones. Chaperones are proteins that bind to the polymer near the wall and prevent its backsliding through Cis side. The important parameters include binding energy, size and the local concentration of the chaperones. The profile of these local concentrations, build up the chaperones distribution. Here we investigate the effects of binding energy, size and the exponential distribution of chaperones in their equilibration in each step of the polymer translocation needed for stable translocation time. The simulation results show that in case of chaperones with the size of a monomer (λ=1) and/or positive effective binding energy and/or uniform distribution, the chaperones binding equilibration rate/frequency is less than 5 times per monomer. However, in some special cases in the exponential distribution of chaperones with size λ>1 and negative effective binding energy the equilibration rate will diverge to more than 20 times per monomer. We show that this non-equilibrium effect results in supper diffusion, seen before. Moreover, we confirm the equilibration process theoretically.  相似文献   
7.
Several resonances in the molecular spectrum of the exotic dtμ* ion are obtained. We present a theoretical formulation for its energy levels together with the numerical calculations for the nuclear fusion rates. The calculations are performed with the coupled rearrangement channel method, but with a set of functions alternative to others. © 2008 Wiley Periodicals, Inc. Int J Quantum Chem, 2009  相似文献   
8.
[5,10,15,20-Tetrakis(4-N,N-dimethylaminobenzene)porphyrinato]Mn(III) acetate (MnTDPAc) was applied as an ionophore for an iodide-selective PVC membrane electrode. The influences of the membrane composition, pH of the test solution and foreign ions on the electrode performance were investigated. The sensor exhibited not only excellent selectivity to iodide ion compared to Cl- and lipophilic anions such as ClO4- and salicylate, but also a Nernstian response with a slope of -59.4 +/- 1.2 mV per decade for iodide ions over a wide concentration range from 1.0 x 10(-2) to 7.5 x 10(-6) M at 25 degrees C. The potentiometric response was independent of the pH of the solution in the pH range of 2 - 8. The electrode could be used for at least 2 months without any considerable divergence in the potential. Good selectivity for iodide ion, a very short response time, simple preparation and relatively long-term stability were the silent characteristics of this electrode. It was successfully used as an indicator electrode in the potentiometric titration of iodide ions, and also in the determination of iodide from seawater samples and drug formulations.  相似文献   
9.
A solid-phase microextraction fiber was prepared by polyaniline/graphene oxide nanocomposite as sorbent on the surface of a platinized stainless steel wire using electrospinning technique. The nanocomposite structure was characterized by scanning electron microscopy and Fourier transform infrared spectroscopy. The polyaniline/graphene oxide nanocomposite fiber was used for the determination of nicotine from tobacco samples using headspace solid-phase microextraction method and gas chromatography–flame ionization detection. Influential experimental variables on the extraction efficiency of nicotine, such as extraction time and temperature, humidity and desorption conditions, were evaluated and optimized. Under the optimal experimental conditions? the limit of detection, linear dynamic range, intraday and inter-days precisions were found to be 0.01 μg g?1, 0.05–700 µg g?1 (R2?=?0.996), 6.9 and 8.1%, respectively. Comparison of the polyaniline/graphene oxide nanocomposite sorbent with polyaniline and commercial fibers shows longer durability, larger capacity and higher extraction efficiency. The polyaniline/graphene oxide nanocomposite fiber was successfully applied for the determination of nicotine in tobacco samples.  相似文献   
10.
A novel optimized chelating hydrogel was synthesized via graft copolymerization of acrylamide and 2‐hydroxyethyl methacrylate (as two‐dentate chelating co‐monomer) onto salep (a multicomponent polysaccharide obtained from dried tubers of certain natural terrestrial orchids) using N,N′‐methylenebisacrylamide as a crosslinker and ammonium persulfate as an initiator. Reaction parameters (N,N′‐methylenebisacrylamide and ammonium persulfate amounts as well as acrylamide/2‐hydroxyethyl methacrylate weight ratio) affecting the water absorption of the chelating hydrogel were optimized using a systematic method to achieve a hydrogel with high swelling capacity as possible. Heavy metal ion adsorption capacity of the optimized hydrogel for metal ions [Cu (II), Pb (II), Cd (II), and Cr (III)] were investigated in aqueous media containing different concentrations of these ions (5–50 ppm). The results showed that the hydrogel have great potential for heavy metal removal from aqueous solutions. The hydrogel formation was confirmed by Fourier transform infrared spectroscopy, and surface morphology study of the hydrogel was performed by scanning electron microscope. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号