首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   1篇
  免费   0篇
  国内免费   3篇
物理学   4篇
  2020年   1篇
  2013年   1篇
  2012年   1篇
  2010年   1篇
排序方式: 共有4条查询结果,搜索用时 375 毫秒
1
1.
We emphasize that it is extremely important for future neutrinoless double-beta(0νββ)decay experiments to reach the sensitivity to the effective neutrino mass|mββ|≈1 meV.With such a sensitivity,it is highly possible to discover the signals of 0νββ decays.If no signal is observed at this sensitivity level,then either neutrinos are Dirac particles or stringent constraints can be placed on their Majorana masses.In this paper,assuming the sensitivity of|mββ|≈1 meV for future 0νββ decay experiments and the precisions on neutrion oscillation parameters after the JUNO experiment,we fully explore the constrained regions of the lightest neutrino mass m1 and two Majorana-type CP-violating phases{ρ,σ}.Several important conclusions in the case of normal neutrino mass ordering can be made.First,the lightest neutrino mass is severely constrained to a narrow range m1∈[0.7,8]meV,which together with the precision measurements of neutrino mass-squared differences from oscillation experiments completely determines the neutrino mass spectrum m2∈[8.6,11.7]meV ing phases is limited to ρ∈[130°,230°],which cannot be obtained from any other realistic experiments.Third,the sum of three neutrino masses is found to beΣ≡m1+m2+m3∈[59.2,72.6]meV,while the effective neutrino mass for beta decays turns out to be mβ≡(|Ue1|2m1^2+|Ue2|2m2^2+|Ue3|2m3^2)1/2∈[8.9,12.6]meV.These observations clearly set up the roadmap for future non-oscillation neutrino experiments aiming to solve the fundamental problems in neutrino physics.  相似文献   
2.
Liquid scintillators are widely used as the neutrino target in neutrino experiments.The absorption and emission of different components of a ternary liquid scintillator (Linear Alkyl Benzene (LAB) as the solvent,2,5-diphenyloxazole (PPO) as the fluor and p-bis-(o-methylstyryl)-benzene (bis-MSB) as wavelength shifter) are studied.It is shown that the absorption of this liquid scintillator is dominant by LAB and PPO at wavelengths less than 349 nm,and the absorption by bis-MSB becomes prevalent at the wavelength larger than 349 nm.The fluorescence quantum yields,which are the key parameters to model the absorption and re-emission processes in large liquid scintillation detectors,are measured.  相似文献   
3.
An attenuation length measurement device was constructed using an oscilloscope and LabVIEW for signal acquisition and processing. The performance of the device has been tested in a variety of ways. The test results show that the set-up has a good stability and high precision (sigma/mean reached 0.4 percent). Besides, the accuracy of the measurement system will decrease by about 17 percent if a filter is used. The attenuation length of a gadolinium-loaded liquid scintillator (Gd-LS) was measured as 15.10±0.35 m where Gd-LS was heavily used in the Daya Bay Neutrino Experiment. In addition, one method based on the Beer-Lambert law was proposed to investigate the reliability of the measurement device, the R-square reached 0.9995. Moreover, three purification methods for Linear Alkyl Benzene (LAB) production were compared in the experiment.  相似文献   
4.
Detailed measurements of Hamamatsu R5912 photomultiplier signals are presented, including the single photoelectron charge response, waveform shape, nonlinearity, saturation, overshoot, oscillation, prepulsing, and afterpulsing. The results were used to build a detailed model of the PMT signal characteristics over a wide range of light intensities. Including the PMT model in simulated Daya Bay particle interactions shows no significant systematic effects that are detrimental to the experimental sensitivity.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号