首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   76篇
  免费   2篇
化学   63篇
力学   1篇
数学   2篇
物理学   12篇
  2022年   2篇
  2021年   2篇
  2020年   1篇
  2019年   2篇
  2018年   1篇
  2016年   6篇
  2015年   3篇
  2014年   4篇
  2013年   14篇
  2012年   5篇
  2011年   2篇
  2010年   5篇
  2009年   4篇
  2008年   2篇
  2007年   10篇
  2006年   6篇
  2004年   1篇
  2003年   2篇
  2002年   4篇
  2001年   1篇
  1974年   1篇
排序方式: 共有78条查询结果,搜索用时 328 毫秒
1.
This study developed a nanosensor for the detection and determination of favipiravir, a presumed drug that has potential therapeutic efficacy in treating COVID-19 patients, from tablets and serum samples. This nanosensor was obtained by adding the optimum amount of diamond nanoparticles into carbon paste. For the determination of favipiravir adsorptive stripping differential pulse (AdSDPV) and adsorptive stripping square wave voltammetry (AdSSWV) were used. Limit of detection values were found as 4.83×10−9 M and 2.44×10−7 M for bulk and 5.18×10−8 M and 4.38×10−8 M for serum samples using AdSDPV and AdSSWV, respectively. Recovery studies made of the tablet and serum produced satisfactory results.  相似文献   
2.
This paper demonstrates a Schiff base i. e. 5-(diethylamino)-2-((2,6-diethylphenylimino)methyl)phenol (5-DDMP) that was sensed by DNA biosensor. dsDNA was immobilized onto GCE modified with functionalized multi-walled carbon nanotubes to prepare a biosensor. The efficiency of dsDNA biosensor was determined and binding of 5-DDMP with dsDNA was searched by UV-vis spectrophotometry and differential pulse voltammetry. Molecular docking simulations between 5-DDMP and dsDNA were explored and as a result, a hydrogen bond and a π-π contact were observed between 5-DDMP and deoxyguanosine base (dG22) of the strand B, deoxyadenosine base (dA5) of the strand A, respectively. These studies could be useful for new anticancer drug design and development.  相似文献   
3.
In order to investigate of cobalt-doped interracial polyvinyl alcohol (PVA) layer and interface trap (Dit) effects, A1/p- Si Schottky barrier diodes (SBDs) are fabricated, and their electrical and dielectric properties are investigated at room temperature. The forward and reverse admittance measurements are carded out in the frequency and voltage ranges of 30 kHz-300 kHz and -5 V-6 V, respectively. C-V or er-V plots exhibit two distinct peaks corresponding to inversion and accumulation regions. The first peak is attributed to the existence of Dit, the other to the series resistance (Rs), and interfacial layer. Both the real and imaginary parts of dielectric constant (er and err) and electric modulus (Mr and Mrr), loss tangent (tan~), and AC electrical conductivity (aac) are investigated, each as a function of frequency and applied bias voltage. Each of the M~ versus V and Mrr versus V plots shows a peak and the magnitude of peak increases with the increasing of frequency. Especially due to the Dit and interfacial PVA layer, both capacitance (C) and conductance (G/w) values are strongly affected, which consequently contributes to deviation from both the electrical and dielectric properties of A1/Co-doped PVA/p-Si (MPS) type SBD. In addition, the voltage-dependent profile of Dit is obtained from the low-high frequency capacitance (CLF-CHF) method.  相似文献   
4.
Kurbanoglu  Sevinc  Gumustas  Mehmet  Uslu  Bengi  Ozkan  Sibel A. 《Chromatographia》2013,76(21):1477-1485

A RP-LC method is presented, which is sensitive and selective for the simultaneous determination of enalapril–lercanidipine and enalapril–nitrendipine binary mixtures in their pharmaceutical dosage forms. The analyte peaks were detected using the LC method with the mobile phase ratio of methanol: water (70:30 v/v, pH 3.0) and a 1.0 mL min−1 flow rate. The detection wavelength was selected at 210 nm using photo diode array detector and column temperature was optimized to 30 °C. Linearity was obtained at different concentration ranges for all working pharmaceutically active compounds between 0.5 and 25 μg mL−1. The proposed methods were extensively validated according to USP 27 requirements and ICH guidelines. The methods were applied to the analysis of pharmaceutical dosage forms containing binary mixtures of enalapril–lercanidipine and enalapril–nitrendipine. Moreover, the proposed methods were applied for the degradation studies of the selected compounds. Degradation studies were conducted using stress conditions such as UV light, acidic and alkaline hydrolysis, oxidation and heat in oven, to evaluate the ability of the separation of the response of standard compounds from their degradation products.

  相似文献   
5.
Liquid–liquid equilibrium (LLE) data of the solubility (binodal) curves and tie-line end compositions were examined for mixtures of {(water (1) + levulinic acid (2) + dimethyl succinate or dimethyl glutarate or dimethyl adipate (3)} at 298.15 K and 101.3 ± 0.7 kPa. The reliability of the experimental tie-line data was confirmed by using the Othmer–Tobias correlation. The LLE data of the ternary systems were predicted by UNIFAC method. The LLE data were correlated fairly well with UNIQUAC and NRTL models, indicating the reliability of the UNIQUAC and NRTL equations for these ternary systems. The best results were achieved with the NRTL equation, using non-randomness parameter (α = 0.3) for the correlation. Distribution coefficients and separation factors were measured to evaluate the extracting capability of the solvents.  相似文献   
6.
Magnesium(II), zinc(II), and metal-free phthalocyanines (Pcs) and azaphthalocyanines (AzaPcs) containing alkylsulfanyl, aryloxy, and dialkylamino peripheral substituents have been synthesized. The complexation of magnesium(II) by metal-free Pcs and AzaPcs has been studied in detail to determine the optimal reaction conditions necessary to ensure a complete conversion. Photophysical and photochemical measurements in tetrahydrofuran showed that magnesium(II) AzaPcs with aryloxy and alkylsulfanyl substituents have excellent fluorescent properties (Φ(F) up to 0.73) and that the corresponding zinc(II) Pcs are efficient singlet oxygen producers (Φ(Δ) up to 0.68). The presence of dialkylamino substituents causes intramolecular charge transfer within the molecule that competes with fluorescence and singlet oxygen formation. Alkylsulfanyl MgAzaPc and ZnAzaPc were the most photostable compounds among the series of studied derivatives. In addition, high molar absorption coefficients (ε ~ 300,000 M(-1) cm(-1)), absorption (λ(max) ~ 650 nm), and emission (λ(em) ~ 660 nm, high Φ(F)) in the red region suggest that these molecules are potential fluorescent probes that are superior to the commercial red cyanine dye Cy5. MgAzaPc, when incorporated into lipidic bilayers of liposomes, maintains excellent fluorescence properties (Φ(F) = 0.64). Water-soluble MgAzaPc with quaternary ammonium peripheral substituents retained a high fluorescence quantum yield even in water (Φ(F) = 0.25). The described properties show that magnesium(II) AzaPcs are excellent red-emitting fluorophores with potential applications as fluorescent probes in sensing or in vitro imaging applications.  相似文献   
7.
Uslu B  Topal BD  Ozkan SA 《Talanta》2008,74(5):1191-1200
The anodic behavior and determination of pefloxacin on boron-doped diamond and glassy carbon electrodes were investigated using cyclic, linear sweep, differential pulse and square wave voltammetric techniques. In cyclic voltammetry, pefloxacin shows one main irreversible oxidation peak and additional one irreversible ill-defined wave depending on pH values for both electrodes. The results indicate that the process of pefloxacin is irreversible and diffusion controlled on boron-doped diamond electrode and irreversible but adsorption controlled on glassy carbon electrode. The peak current is found to be linear over the range of concentration 2 × 10−6 to 2 × 10−4 M in 0.5 M H2SO4 at about +1.20 V (versus Ag/AgCl) for differential pulse and square wave voltammetric technique using boron-doped diamond electrode. The repeatability, reproducibility, precision and accuracy of the methods in all media were investigated. Selectivity, precision and accuracy of the developed methods were also checked by recovery studies. The procedures were successfully applied to the determination of the drug in pharmaceutical dosage forms and humans serum samples with good recovery results. No electroactive interferences from the excipients and endogenous substances were found in the pharmaceutical dosage forms and biological samples, respectively.  相似文献   
8.
Ascorbic acid is the most common electroactive biological compound found in some plant species (e.g., Citrus species, Rosa species). The electrochemical oxidation of ascorbic acid was investigated by cyclic, linear sweep, differential pulse (DPV), and square wave (SWV) voltammetry. For analytical purposes, a very well-resolved diffusion-controlled voltammetric peak was obtained in acetate buffer at pH 3.50 for DPV and SWV. The linear response was obtained in the range of 3.52–176.1 μg/mL with a detection limit of 0.88 μg/mL for DPV and 0.52 μg/mL for SWV. Based on this study, simple, rapid, selective, and sensitive voltammetric methods were developed for the determination of ascorbic acid in pharmaceutical dosage forms and Rosa species (R. dumalis ssp. boissieri var. boissieri, R. canina, R. pulverulenta, R. heckeliana ssp. vanheurckiana, and R. montana subsp. woronowii). The results obtained are compared with the HPLC data. The developed methods enable the extracts to be analyzed without the necessity of any time-consuming separation. The text was submitted by the authors in English.  相似文献   
9.
Dogan-Topal  B.  Ozkan  S. A.  Uslu  B. 《Chromatographia》2007,66(1):25-30

A rapid, sensitive, and specific reverse phase high performance liquid chromatography with diode array detection procedure for the simultaneous determination of abacavir, efavirenz and valganciclovir in spiked human serum is described. Separation was performed on a 5 μm Waters Spherisorb column (250 × 4.6 mm ID) with acetonitrile: methanol:KH2PO4 (at pH 5.00) (40:20:40 v/v/v) isocratic elution at a flow rate of 1.0 mL min−1. Calibration curves were constructed in the range of 50–30,000 ng mL−1 for abacavir and efavirenz, and 10–30,000 ngmL−1 for valganciclovir in serum samples. The limit of detection and limit of quantification concentrations of the HPLC method were 3.80 and 12.68 ng mL−1 for abacavir, 2.61 and 8.69 ng mL−1 for efavirenz, 1.30 and 4.32 ng mL−1 for valganciclovir. The method has been applied, without any interference from excipients or endogenous substances, for the simultaneous determination of these three compounds in human serum.

  相似文献   
10.
Dilek Kul  Bengi Uslu 《Talanta》2010,82(1):286-630
Ziprasidone is a psychotropic agent used for the treatment of schizophrenia. Its oxidation was investigated electrochemically at boron-doped diamond and glassy carbon electrodes using cyclic, differential pulse, and square wave voltammetry. The dependence of the peak current and peak potentials on pH, concentration, nature of the buffer, and scan rate were examined. The process was diffusion and adsorption controlled for boron-doped diamond and glassy carbon electrodes, respectively. The possible mechanism of oxidation was discussed with some model compounds that have indole and piperazine oxidations. A linear response was obtained between 8 × 10−7 and 8 × 10−5 M for the first peak in acetate buffer (pH 5.5) and between 2 × 10−6 and 2 × 10−4 M for the second peak in 0.1 M H2SO4 with boron-doped diamond electrode for differential pulse and square wave voltammetric techniques. The reproducibility and accuracy of the proposed methods were found between 0.31 and 1.20, 99.27 and 100.22, respectively. The recovery studies were also achieved to check selectivity and accuracy of the methods. The proposed methods were applied for the determination of ziprasidone from pharmaceutical dosage forms and human serum samples without any time-consuming extraction, separation, evaporation or adsorption steps prior to drug assay except precipitation of the proteins using acetonitrile. The results were statistically compared with those obtained through an established LC-UV technique, no significant differences were been found between the voltammetric and LC methods.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号