首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   47篇
  免费   0篇
化学   35篇
力学   1篇
物理学   11篇
  2023年   2篇
  2022年   2篇
  2021年   1篇
  2020年   3篇
  2019年   1篇
  2018年   1篇
  2017年   1篇
  2016年   1篇
  2015年   3篇
  2014年   2篇
  2013年   4篇
  2012年   2篇
  2011年   3篇
  2010年   2篇
  2009年   5篇
  2008年   4篇
  2007年   1篇
  2006年   3篇
  2005年   3篇
  2004年   1篇
  2000年   1篇
  1999年   1篇
排序方式: 共有47条查询结果,搜索用时 31 毫秒
1.
2.
Nanorod vanadatesulfuric acid (VSA NRs), as a recyclable and eco-benign catalyst, was used for one-pot synthesis of 2,4,5-trisubstituted imidazoles and 1,2,4,5-tetrasubstituted imidazoles using aldehydes, benzil, benzoin or 9,10-phenanthrenequinone and ammonium acetate or aniline under solvent-free conditions providing high to excellent yields. VSA is easily prepared by a simple reaction of chlorosulfonic acid and sodium metavanadate in high purity. As compared with the conventional procedures, the present protocol offers several advantages such as simplicity of procedure, short reaction time, high yields, easy workup, recoverability and reusability of the catalyst and simple purification of the products.  相似文献   
3.
4.
For the first time iridium oxide (IrO2) nanotubes are synthesized by electrodeposition in a polycarbonate (PC) template. Potential cycling (90 cycles) between 0.0 and 0.9 V is used for the preparation of IrOx nanotubes onto the PC template with a pore diameter of 100 nm. Field‐emission scanning electron microscopy (FESEM) images show, that IrO2 nanotubes with uniform diameters of 110±10 nm and an estimated length of 1–3 µm are formed. The electrochemical properties and the electrocatalytic activity of a glassy carbon‐IrOx nanotube modified electrode toward Cr3+ and As3+ oxidation are investigated. Finally, the modified electrode is used for micromolar detection of the proposed analytes using differential pulse voltammetry.  相似文献   
5.
Poly(2-vinylpyridine)s (P2VPs) are important polymers with extensive applications in modern day material science. P2VP is an exceptional case for liquid chromatography because of certain polar interactions with most of the stationary phases. In the present study, we established the critical adsorption point (CAP) of P2VP for the first time. The effectiveness of the method is demonstrated by analyses of blends and block copolymers of P2VP and PMMA. The CAP of PMMA is established for determination of molar mass of P2VP component of above mentioned blends and block copolymers. The methods successfully demonstrate the separation of both types of homopolymers from the rest of the samples in conjunction with the determination of molar mass distribution of noncritical block or component. Graphical Abstract
?  相似文献   
6.
In this paper we give a classification of plane symmetric static space-times using symmetry method. For this purpose we consider the Lagrangian corresponding to the general plane symmetric static metric in the Noether symmetry equation. This provides a system of determining equations. Solutions of this system give us classification of the plane symmetric static space-times according to their Noether symmetries. During this classification we recover all the results listed in Feroze et al. (J. Math. Phys. 42:4947, 2001) and Bashir and Ehsan (Il Nuovo Cimento B 123:1, 2008).  相似文献   
7.
Salimi A  Mamkhezri H  Hallaj R 《Talanta》2006,70(4):823-832
A sol-gel carbon composite electrode (CCE) has been prepared by mixing a sol-gel precursor (e.g. methyltrimethoxysilane) and carbon powder without adding any electron transfer mediator or specific reagents. It was demonstrated that this sensor can be used for simultaneous determination ascorbic acid, neurotransmitters (dopamine and adrenaline) and uric acid. Direct electrochemical oxidation of ascorbic acid, uric acid and catecholamines at a carbon composite electrode was investigated. The experimental results were compared with other common carbon based electrodes, specifically, boron doped diamond, glassy carbon, graphite and carbon paste electrodes. It was found that the CCE shows a significantly higher of reversibility for dopamine. In addition, in comparison to the other electrodes used, for CCE the oxidation peaks of uric acid, ascorbic acid and catecholamines in cyclic and square wave voltammetry were well resolved at the low positive potential with good sensitivity. The advantages of this sensor were high sensitivity, inherent stability and simplicity and ability for simultaneous determination of uric acid, catecholamines and ascorbic acid without using any chromatography or separation systems. The analytical performance of this sensor has been evaluated for detection of biological molecules in urine and serum as real samples.  相似文献   
8.
Salimi A  Hallaj R  Ghadermazi M 《Talanta》2005,65(4):888-894
The carbon ceramic electrode prepared with sol-gel technique is modified by a thin film of chlorogenic acid (CGA). By immersing the carbon ceramic electrode in aqueous solution of chlorogenic acid at less than 2 s a thin film of chlorogenic acid adsorbed strongly and irreversibly on the surface of electrode. The cyclic voltammetry of the resulting modified CCE prepared at optimum conditions shows a well-defined stable reversible redox couple due to hydroquinone/quinone system in both acidic and basic solutions. The modified electrode showed excellent electrocatalytic activity toward NADH oxidation and it also showed a high analytical performance for amperometric detection of NADH. The catalytic rate constant of the modified carbon ceramic electrode for the oxidation of NADH is determined by cyclic voltammetry measurement. Under the optimised conditions the calibration curve is linear in the concentration range 1-120 μm. The detection limit (S/N = 3) and sensitivity are 0.2 μM and 25 nA μM−1.The results of six successive measurement-regeneration cycles show relative standard deviations of 2.5% for electrolyte solution containing 1 mM NADH, indicating that the electrode renewal gives a good reproducible and antifouling surface. The advantages of this amperometric detector are: high sensitivity, excellent catalytic activity, short response time t < 2 s, remarkable long-term stability, simplicity of preparation at short time and good reproducibility.  相似文献   
9.
Iridium oxide nanoparticles are grown on a glassy carbon electrode by electrodepositing method. The electrochemical behavior and electrocatalytic activity of modified electrode towards reduction of iodate and periodate are studied. The reductions of both ions occur at the unusual positive peak potential of 0.7 V vs. reference electrode. The modified electrode is employed successfully for iodate and periodates detection using cyclic voltammetry, hydrodynamic amperometry and flow injection analysis (FIA). In the performed experiments, flow injection amperometric determination of iodate and periodate yielded calibration curves with the following characteristics: linear dynamic range up to 100 and 80 μM, sensitivity of 140.9 and 150.6 nA μM−1 and detection limits of 5 and 36 nM, respectively. The repeatability of the modified electrode for 21 injections of 1.5 μM of iodate solution is 1.5%. The interference effects of NO2, NO3, ClO3, BrO3, ClO4, SO42−, Cu2+, Zn2+, Mn2+, Mg2+, Cd2+, Ca2+, Na+, K+, NH4+ and K+, CH3COO and glucose were negligible at the concentration ratio of more than 1000. The obtained attractive analytical performance together with high selectivity and simplicity of the proposed method provide an effective and e novel modified electrode to develop an iodate and periodate sensor. Sensitivity, selectivity, the liner concentration range and the detection limit of the developed sensor are all much better than all known similar sensors in the literature for iodate and periodate determination.  相似文献   
10.
Journal of Fluorescence - This work focuses on the synthesis of novel modified core–shell CdTe/CdS quantum dots (QDs) and develops as a fluorescence sensor for glucose determination. The...  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号