The adsorption and photocatalytic degradation of Ethyl methylphosphonate (EMPA) on powdery TiO2 film has experimentally investigated using attenuated total reflection-infrared Fourier transform spectroscopy (ATR-FTIR) in ambient condition. Characteristic IR frequency as P-O-C vibration mode as EtO was observed by EMPA adsorbed at the surface of TiO2. By TiO2 photocatalysis, the adsorbed EMPA was decomposed to methyl phosphonic acid and phosphoric acid. The increment of IR intensity of which is assigned to Ti–O-P-O-Ti of EMPA was accompanied with increasing the IR peak intensity assigned to MPA. About that, we suggest that the appearance of the Ti–O-P-O-Ti of EMPA by the TiO2 photocatalysis is regarded as acceleration of the hydrolysis of EMPA by the surface OH groups of TiO2. The plausible adsorption structure and the photocatalytic reaction mechanism of EMPA at the surface of TiO2 photocatalyst were elucidated.
A new high-performance liquid chromatography (HPLC) method has been developed to detect ultra-low concentrations of bisphenol-A (BPA) (below 1 ng/L (ppt)) using column switching electrochemical detection (ECD). The results were superior to those obtained from manual pretreatment procedure with membrane stationary phase. BPA is inherently ubiquitous in the environment, including tools and solvents used for its analysis; to obtain meaningful results, therefore, the concentration of the overall BPA contamination must be below the detection limit for BPA using the analytical system. Therefore, purified water for preparing the standard BPA solution must be filtered with a hydrophobic membrane to suppress BPA background levels of contamination. In addition, we investigated methods for effectively preserving environmental water containing BPA. The addition of a small amount of ethylenediaminetetraacetic acid (EDTA) provided good recovery even after overnight storage. By employing these precautionary measures and procedures to reduce BPA contamination from the analytical procedure, we could accurately determine l(-10) ppt of BPA in environmental water samples using a column switching HPLC system. 相似文献
In this paper we focus on the problem of identifying the index sets P(x):=i|xi>0, N(x):={i|Fi(x)>0 and C(x):=i|xi=Fi(x)=0} for a solution x of the monotone nonlinear complementarity problem NCP(F). The correct identification of these sets is important from both theoretical and practical points of view. Such an identification enables us to remove complementarity conditions from the NCP and locally reduce the NCP to a system which can be dealt with more easily. We present a new technique that utilizes a sequence generated by the proximal point algorithm (PPA). Using the superlinear convergence property of PPA, we show that the proposed technique can identify the correct index sets without assuming the nondegeneracy and the local uniqueness of the solution.This work was supported in part by a Grant-in-Aid for Scientific Research from the Ministry of Education, Science, Sports and Culture of Japan.Mathematics Subject Classification (2000): 90C33, 65K10 相似文献
Hydro-membrane gas chromatography (HMGC) is achieved by the annular condensation of water in a capillary column at less than 70 degrees C. The annular membrane of water is formed as a result of the wettability of the stationary phase, which is induced at a water contact angle ranging from 75 degrees to 79 degrees, as derived from a solubility parameter (delta) range of 15.7 +/- 0.3 MPa(1/2) of the coated resin. The range of the liquid to gas volume ratio (beta) required to support the annular membrane should be kept between 0.00005 and 0.0003. In the case of a 0.25-mm i.d. column, the ratio can be set by the combination of a 0.1 to 0.2 microl min(-1) water supply rate and helium gas flow rate. Separation by HMGC develops not only a gas-solid partition but also a focusing effect on the water membrane. One feature of HMGC is that it gives a non-adsorption chromatogram based on the blocking effect of pre-adsorbed water; furthermore, despite the presence of a relatively large quantity of water, the electron impact ionization efficiency is kept the same as in the usual GC/MS condition. The detection limit with the injection of 1 microl of aquatic solution was estimated to be less than 0.1 ppb of low-molecular-weight fatty acids with s/n = 5 on a mass chromatogram at m/z 45. The HMGC/EI-MS system can be applied to the trace analysis of C1 to C3 volatile acids, volatile inorganic acids, and halogenated organic acids in water. 相似文献
In the title compound, [Ca(C6H5O4)2(C6H6O4)2]·4H2O, which is a kojic acid–Ca2+ complex, the Ca atom is on a twofold axis and is octacoordinated by O atoms from four pyrone ligand molecules. The hydroxyl and ketone O atoms of each ligand form a five‐membered chelate ring with the Ca atom. The crystal structure is stabilized by partial stacking and O—H?O hydrogen bonds. 相似文献
An orally applicable pulsatile drug delivery system in dry-coated tablet form was prepared using diltiazem hydrochloride as the model drug, and a polyvinyl chloride-hydrogenated castor oil-polyethyleneglycol mixture as the outer shell of the tablet. In vitro drug release from the prepared tablet exhibited a typical pulsatile pattern with a 7 h lag phase (non-drug release period). This dosage form was orally administered to three beagle dogs under non-fasting and fasting conditions, and the plasma concentration level of diltiazem was determined according to time after administration. The result of the in vivo study in non-fasting dogs suggested that the drug could be released in the gastrointestinal tract as in the in vitro test. However, under the fasting condition, a large difference in the plasma concentration profile was found, suggesting that the disintegration time of the tablet tended to be influenced by the feeding condition of subject. 相似文献
The mirror gap of a Fabry-Perot interferometer was stabilized with two laser diodes; one locked to the line frequency 385,243,555.14445 MHz of the F=3<--1 in 5D(3/2)<--5S(1/2) (87Rb) and the other to the 385,284,566.3663 MHz of the F=4<--2 in 5D(5/2)<--5S(1/2) (87Rb) [Opt. Commun. 102 (1993) 432]. The length of the mirror gap was adjusted to generate the zero-cross points simultaneously at both of the two line positions. The fringe signals obtained from an interferometer thus stabilized can be used as frequency markers having accuracies of the order of 10(10) depending on the finesse of the interferometer used. Based on measurement using Cs D1 hyperfine lines reported by Udem et al. [Phys. Rev. Lett. 82 (1999) 3568], the uncertainty of markers in the region 50 THz apart from the reference lines is +/- 5 MHz. 相似文献
Polychlorinated biphenyls (PCBs) and chlorobenzenes (CBzs) are two classes of dioxin precursors formed in municipal solid waste incinerators (MSWIs); they produce negative health effects similar to those of dioxins. Reducing the analytical time required for determining the concentrations of these compounds in MSWIs is important for quickly evaluating their importance and assessing associated health risks. In the present study, water is used as a safe and environmentally friendly solvent in microwave-assisted extraction (MAE) for PCB and CBz analyses. MAE is compared with traditional Soxhlet extraction (SE) to determine the extraction efficiencies. The evaluation of extraction efficiencies shows that MAE has a high extraction efficiency compared with that of SE when water content is lower than 60%. Furthermore, the extraction time and organic solvent consumption are reduced with MAE compared with SE. 相似文献
Cholesterol and 20-hydroxycholesterol labelled at C-22 stereospecifically by deuterium were incubated with the enzyme of bovine adrenocortical mitochondria. The results indicated that hydroxylation occurs with retention of the configuration of C-22 to give exclusively the 22R stereoisomers of 22-hydroxy- and/or 20,22-dihydroxycholesterol. 相似文献