In the present research, magnesium aluminate spinel was prepared as catalyst support using a novel, facile, and efficient mechanochemical method. The Co-promoted catalysts with 20 wt.% of Ni were fabricated using an impregnation route and the samples were analyzed by the X-ray diffraction (XRD), N2 adsorption/desorption (BET), temperature-programmed reduction and desorption (H2-TPR and O2-TPD), and field emission scanning electron microscopy (FESEM) tests. The results confirmed that all samples have a mesoporous structure with a high specific surface area and the presence of cobalt caused complete CH4 oxidation at low temperatures, and no side reactions were observed. The results indicated that the 3%Co-20%Ni/MgAl2O4 catalyst was the optimal sample among the prepared catalysts, owing to the improvement of reduction features and oxygen mobility. The 50 and 90% of methane conversion was obtained at 530 and 600 °C, respectively. Also, the influence of calcination temperature, GHSV, and feed ratio was determined on the catalytic activity. The obtained outcomes revealed that the calcination temperature has a significant effect on the textural properties and catalytic efficiency. The sample calcined at 700 °C showed the weakest performance, which was related to the sintering of particles at high temperatures. The catalytic stability showed that the 3%Co-20%Ni/MgAl2O4 has acceptable stability during 600 min time of reaction.
Journal of Thermal Analysis and Calorimetry - Nanofluids are attractive alternatives for the current heat transfer fluids due to their remarkably higher thermal conductivity which leads to the... 相似文献
A simple, precise and accurate method is proposed for rapid determination of trace amounts of hydroxylamine based on the reaction of hydroxylamine with iodate in acidic media. The reaction of neutral red by the produced nitrite ion was used to monitor the reaction spectrophotometrically at 525 nm by a fixed time method. Hydroxylamine in the range of 0.0400-1.200 microg mL(-1) could be determined. The relative standard deviation for 10 determinations of 0.500 microg mL(-1) hydroxylamine was 1.81% and the limit of detection was 0.010 microg mL(-1). The proposed method was applied to the determination of hydroxylamine in water samples with satisfactory results. 相似文献
As borders between different entities, lines are an important element of natural images. Indeed, the neurons of the mammalian
visual cortex are tuned to respond best to lines of a given orientation. This preferred orientation varies continuously across
most of the cortex, but also has vortex-like singularities known as pinwheels. In attempting to describe such patterns of
orientation preference, we are led to consider underlying rotation symmetries: Oriented segments in natural images tend to
be collinear; neurons are more likely to be connected if their preferred orientations are aligned to their topographic separation.
These are indications of a reduced symmetry requiring joint rotations of both orientation preference and the underlying topography.
This is verified by direct statistical tests in both natural images and in cortical maps. Using the statistics of natural
scenes we construct filters that are best suited to extracting information from such images, and find qualitative similarities
to mammalian vision.
PACS84.35+i 89.70.+c 87.57.Nk 相似文献
[5,10,15,20-Tetrakis(4-N,N-dimethylaminobenzene)porphyrinato]Mn(III) acetate (MnTDPAc) was applied as an ionophore for an iodide-selective PVC membrane electrode. The influences of the membrane composition, pH of the test solution and foreign ions on the electrode performance were investigated. The sensor exhibited not only excellent selectivity to iodide ion compared to Cl- and lipophilic anions such as ClO4- and salicylate, but also a Nernstian response with a slope of -59.4 +/- 1.2 mV per decade for iodide ions over a wide concentration range from 1.0 x 10(-2) to 7.5 x 10(-6) M at 25 degrees C. The potentiometric response was independent of the pH of the solution in the pH range of 2 - 8. The electrode could be used for at least 2 months without any considerable divergence in the potential. Good selectivity for iodide ion, a very short response time, simple preparation and relatively long-term stability were the silent characteristics of this electrode. It was successfully used as an indicator electrode in the potentiometric titration of iodide ions, and also in the determination of iodide from seawater samples and drug formulations. 相似文献
Trichloroisocyanuric acid is used as an effective oxidizing agent for the oxidation of 1,3,5-trisubstituted pyrazolines to their corresponding pyrazoles under both heterogeneous and also solvent free conditions with good yields at room temperature. 相似文献
A new method for extraction and analysis of acetone in human urine based on headspace solid phase microextraction using a
mixture of activated carbon and zeolite as sorbents in a PVC matrix coated on a silver wire and its application to the determination
of ketone bodies is described. Unlike commercial fibers, which are coated on fused silica, the coating adheres strongly to
the silver wire and is thermally stable up to 250 °C. After optimization of coating composition and microextraction conditions
the fiber was used for the analysis of acetone in human urine. 相似文献
An efficient synthesis of 3,4-dihydropyrimidin-2-(1H)-one derivatives by one-pot three-component condensation reaction between an alkyl or aryl aldehyde, a 1,3-dicarbonyl compound,
and urea or thiourea in the presence of catalytic amount of bromodimethylsulfonium bromide has been developed. The condensation
product was obtained in excellent yields in refluxing ethanol and easily separated from the reaction mixture and purified. 相似文献