11.
本文提出了对日本岛津产 ICP10 0 0型等离子体发射光谱仪的改造方法 ,并详细介绍了具体仪器的硬件改造过程 ,以及改造后的考核测试结果 ,为国内该种大型精密光学仪器的改造做了有益的尝试。  相似文献   
12.
Monolithic columns were introduced in the early 1990s and have become increasingly popular as efficient stationary phases for most of the important chromatographic separation modes. Monoliths are functionally distinct from porous particle-based media in their reliance on convective mass transport. This makes resolution and capacity independent of flow rate. Monoliths also lack a void volume. This eliminates eddy dispersion and permits high-resolution separations with extremely short flow paths. The analytical value of these features is the subject of recent reviews. Nowadays, among other types of rigid macroporous monoliths, the polymethacrylate-based materials are the largest and most examined class of these sorbents. In this review, the applications of polymethacrylate-based monolithic columns are summarized for the separation, purification and analysis of low and high molecular mass compounds in the different HPLC formats, including micro- and large-scale HPLC modes.  相似文献   
13.
In recent years the use of monolithic polymers in separation science has greatly increased due to the advantages these materials present over particle-based stationary phases, such as their relative ease of preparation and good permeability. For these reasons, these materials present high potential as stationary phases for the separation and purification of large molecules such as proteins, peptides, nucleic acids and cells. An example of this is the wide range of commercial available polymer-based monolithic columns now present in the market.  相似文献   
14.
Hui-Ling Lee 《Talanta》2007,73(1):76-80
A sensitive and robust high-performance liquid chromatography-electrospray ionization tandem mass spectrometry method to analyze 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK) and its five metabolites in one passage was developed and validated. The method achieved excellent reproducibility and accuracy. Linearity was observed for all six compounds (R2 = 0.999) with detection limits (S/N ≥ 3) ranging from 0.2 to 2.4 pg on column and 0.01-0.12 ng ml−1 in samples injected. Average intra-day and inter-day variations (% R.S.D.) were 1.2 and 3.5%, respectively. A sample preparation method involving C8 and C18 solid phase extraction provided satisfactory recovery of the analytes in mouse urine. Each NNK metabolite was identified by its chromatographic retention time and specific fragmentation pattern. Since the carcinogenicity of NNK is related to its metabolism, the method described in this report should facilitate toxicological investigations into the carcinogenesis due to NNK exposure in the environment.  相似文献   
15.
The control of pesticides in surface, drinking and groundwater is nowadays a real necessity. In the European Community, their concentration must comply with the established parametric and environmental quality standards (EQSs). Regarding the new legislation, this article updates the information concerning the monitoring of pesticides and the technical specifications for their measurement in water samples where ultra-sensitive analytical methods are required. For some compounds, like pesticides, there is still a need to improve the performance of the existing methods. High sensitive techniques like gas chromatography tandem mass spectrometry (GC–MS/MS) and liquid chromatography coupled with mass spectrometry (LC–MS) have been developed. However, for most of the substances present at trace and ultra-trace levels the extraction and preconcentration steps are so far essential for their detection. Advances at a micro scale have been made and different types of microextractions are being developed. Liquid-phase microextraction (LPME) is an example. The study of this technique has increased in the last years and some innovations have been recently reported for pesticides water analysis. This article reviews the new developed LPME-based techniques and compares its performance with the analytical specifications established for pesticides water monitoring. The results show that LPME-based techniques can be a promising tool to improve the nowadays performance of methods used in pesticides water control.  相似文献   
16.
A new, simple, fast and sensitive ion chromatography (IC) method, for the simultaneous analysis of fluoride, chloride, nitrite, bromide, nitrate, phosphate and sulphate in edible seaweeds was developed and reported for the first time. The validation of the analytical method was studied in terms of linearity, sensitivity, precision and accuracy. All standard calibration curves showed very good correlation between anion peak area and concentration (r > 0.999). Limits of detection and quantitation ranged between 0.002-0.05 mg/L and 0.01-0.1 mg/L, respectively and indicated the high sensitivity of the method. Relative standard deviation values of repeatability and inter-day precision for standard anions with the same sample were less than 2%. Anion recoveries ranged from 97 to 113% for chloride and from 87 to 105% for sulphate, respectively and showed the fairly good accuracy of the method. The method was applied to the analysis of inorganic anions in brown and red edible seaweeds. Brown seaweeds were characterized by higher chloride content up to 33.7-36.9%, while red seaweeds were characterized by higher sulphate content (45-57%). Sulphate content in seaweeds is related to the presence of sulphated polysaccharides of biological importance. The method developed was well applicable to mineral anion analysis in edible seaweeds and shows suitability and reliability of use in other food samples of nutritional importance.  相似文献   
17.
Ochratoxin A (OTA) exhibits potent nephrotoxic, carcinogenic and teratogenic effects and its maximum level in wines has been set to 2 μg L−1 by regulation. Consequently, the analytical procedures for OTA determination in wines have to be both very sensitive and reliable. In this paper, we compared two quantification methods: the stable isotope dilution assay (SIDA) and the diastereomeric dilution assay (DIDA). For this purpose, non-natural analogues of OTA were synthesized: the labeled OTA (OTA-d4) as a diastereomeric mixture for the SIDA and one non-natural OTA’s diastereomer (OTA-dia) for the DIDA. To quantify OTA in red grapes, musts or wines, the sample preparation was optimized using immunoaffinity column extraction and the analysis was performed by LC–MS/MS in Multiple Reaction Monitoring mode. A validation procedure in agreement with the International Organization of Vine and Wine recommendations was conducted. It appeared that SIDA quantification exhibited excellent sensitivity (LOD < 1 ng L−1), accuracy (recovery = 98%), repeatability (RSD < 3%) and intermediate reproducibility (RSD < 4%) compared to quantification by DIDA. Indeed, DIDA method did not provide satisfactory results demonstrating that immunoaffinity extraction is exclusively selective for the natural OTA and not for its diastereomer, which therefore cannot be considered as a good internal standard for this particular method.  相似文献   
18.
A highly sensitive method was developed for the identification and quantification of fatty alcohols in biological tissues. In the presence of pyridine-d0 and triflic anhydride (Tf2O), fatty alcohols were converted into permanently charged N-alkylpyridinium ions. Stable isotope-labeled derivatives were generated by pyridine-d5 and added as internal standard (IS). The mixture was analyzed by liquid chromatography coupled to positive electrospray ionization tandem mass spectrometry (LC–ESI-MS/MS). This method was optimized and validated in terms of reaction time, derivatization efficiency, stability, desalting, and ion suppression effect. Besides, fatty alcohols exhibited good linear relationship (r2 > 0.993) over the concentration range of 10 ng mL−1–1 μg mL−1. The limits of detection (LODs) were lowered from previously reported 0.1 ng mL−1 to 0.25 pg mL−1. Precision (RSD% < 15.6%), accuracy (93.0–107.2%), matrix effect, and recovery (in thyroid tissues) were validated as well. Finally, this method was applied for the analysis of ten even carbon-numbered fatty alcohols (C8–C24) in human thyroid carcinoma and para-carcinoma tissues, revealing a significant decrease of fatty alcohols (free and esterified) in thyroid carcinoma tissues (< 0.05).  相似文献   
19.
The scope of this paper is to study the performance of noise barriers treated with different diffusers with/without a perforated sheet. We investigated the barrier insertion loss using a 2D boundary element method (BEM). To obtain a better depth sequence, a Random Sequence Diffuser (RSD) was designed. The results clearly showed that employing a "RSD" instead of the most popular Schroeder diffusers (Quadratic Residue Diffuser and Primitive Root Diffuser) increased the acoustic performance. We also found that the diffuser performance improved by treating the diffuser with perforated sheets either on the top surface or inside the wells. The addition of these perforated sheets inside the "RSD" (barrier model "RPI2") improved the performance by 3.59 dB (A).  相似文献   
20.
A new reliable and highly sensitive method based on high performance liquid chromatographic (HPLC) separation and high resolution tandem mass spectrometric detection (HRMS/MS) has been developed and validated for determination of 323 pesticide residues, 55 mycotoxins, and 11 plant toxins represented by pyrrolizidine alkaloids. The method was validated for three matrices, leek, wheat, and tea differing in nature/amount of co-extracts that may cause various matrix effects. For target analytes isolation, optimized QuEChERS-based (quick, easy, cheap, effective, rugged, and safe) extraction procedure was employed. Spectral HRMS/MS library has been established providing an entire spectrum of fragment ions for each analyte, which allows unbiased identification and confirmation of target compounds. The limits of quantification (LOQs) of target analytes were below 10 μg kg−1 for 82%, 81%, and 61% for matrices leek, wheat, and tea, respectively. Recoveries were in the acceptable range (70–120%) according to SANCO/12571/2013 for most of target analytes, except for highly polar ‘masked’ mycotoxin deoxynivalenol-3-glucoside with recoveries 35%, 47%, and 42% for matrices leek, wheat, and tea, respectively. The linearities of calibration curves expressed as coefficients of determination were in the range of 0.9661–1.000, and repeatabilities expressed as relative standard deviations (RSDs) at LOQs lied in the range of 0.25–13.51%. The trueness of the method was verified using several certified reference materials (CRMs) and proficiency test samples.  相似文献   