首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   53篇
  免费   2篇
化学   50篇
物理学   5篇
  2015年   6篇
  2014年   9篇
  2013年   8篇
  2012年   7篇
  2011年   8篇
  2010年   7篇
  2009年   2篇
  2008年   2篇
  2007年   2篇
  2006年   1篇
  2005年   1篇
  1997年   1篇
  1981年   1篇
排序方式: 共有55条查询结果,搜索用时 615 毫秒
31.
In this work, a new method employing capillary electrophoresis (CE) for the determination of several species in biodiesel is introduced. The concentrations of inorganic species (Na+, K+, Ca2+, Mg2+, SO42−, and PO43−) and glycerol are of interest to the regulatory authorities due to their ability to form undesirable compounds in engines. Additionally, other species of low molecular weight (e.g., acetate, formate, and propionate) are of interest because they contribute towards increasing the acidity. These species are formed by the degradation of biodiesel and cause damage to engines and the environment. The cation separation was performed in background electrolyte (BGE) composed of 30 mmol L−1 of 2-(n-morpholino)ethanesulfonic acid (MES)/L-histidine (His), pH 6. The separation of anionic species was carried out in similar BGE with 0.2 mmol L−1 cetyltrimethylammonium bromide (CTAB) added. For glycerol, a neutral species, its oxidation with periodate was employed. This well-known reaction is specific to polyols and generates iodate. The amount of iodate produced by the reaction was determined by CE. The separation was carried out in approximately 1 min using BGE composed of 30 mmol L−1 acetic acid, pH 3. The analytical parameters evaluated were: linearity (r > 0.99), the RSD values for area and migration time were < 3.4% and 0.9%, respectively, and recovery was in the range of 89 to 107%.  相似文献   
32.
Three major elements, carbon, hydrogen, and nitrogen, in twenty-four bituminous coal samples, were measured by laser-induced breakdown spectroscopy. Argon and helium were applied as ambient gas to enhance the signals and eliminate the interference of nitrogen from surrounding air. The relative standard deviation of the related emission lines and the performance in the partial least squares (PLS) modeling were compared for different ambient environments. The results showed that argon not only improved the intensity, but also reduced signal fluctuation. The PLS model also had the optimal performance in multi-element analysis using argon as ambient gas. The root mean square error of prediction of carbon concentration decreased from 4.25% in air to 3.49% in argon, while the average relative error reduced from 4.96% to 2.98%. Hydrogen line demonstrated similar improvement. Yet, the nitrogen lines were too weak to be detected even in an argon environment which suggested the nitrogen signal measured in air come from the breakdown of nitrogen molecules in the atmosphere.  相似文献   
33.
In the present paper, a critical overview of the most commonly used techniques for the characterization and the determination of carbon nanotubes (CNTs) is given on the basis of 170 references (2000–2014). The analytical techniques used for CNT characterization (including microscopic and diffraction, spectroscopic, thermal and separation techniques) are classified, described, and illustrated with applied examples. Furthermore, the performance of sampling procedures as well as the available methods for the determination of CNTs in real biological and environmental samples are reviewed and discussed according to their analytical characteristics. In addition, future trends and perspectives in this field of work are critically presented.  相似文献   
34.
In recent years the number of environmental applications of elemental speciation analysis using inductively coupled plasma mass spectrometry (ICP-MS) as detector has increased significantly. The analytical characteristics, such as extremely low detection limits (LOD) for almost all elements, the wide linear range, the possibility for multi-elemental analysis and the possibility to apply isotope dilution mass spectrometry (IDMS) make ICP-MS an attractive tool for elemental speciation analysis. Two methodological approaches, i.e. the combination of ICP-MS with high performance liquid chromatography (HPLC) and gas chromatography (GC), dominate the field. Besides the investigation of metals and metalloids and their species (e.g. Sn, Hg, As), representing “classic” elements in environmental science, more recently other elements (e.g. P, S, Br, I) amenable to ICP-MS determination were addressed. In addition, the introduction of isotope dilution analysis and the development of isotopically labeled species-specific standards have contributed to the success of ICP-MS in the field. The aim of this review is to summarize these developments and to highlight recent trends in the environmental application of ICP-MS coupled to GC and HPLC.  相似文献   
35.
In this paper, a new version of salting-out homogenous liquid–liquid extraction based on counter current mode combined with dispersive liquid–liquid microextraction has been developed for the extraction and preconcentration of some pesticides from aqueous samples and their determination by gas chromatography–flame ionization detection. In order to perform the method, aqueous solution of the analytes containing acetonitrile and 1,2-dibromoethane is transferred into a narrow bore tube which is filled partially with NaCl. During passing the solution through the tube, fine droplets of the organic phase are produced at the interface of solution and salt which go up through the tube and form a separated layer on the aqueous phase. The collected organic phase is removed and injected into de-ionized water for more enrichment of the analytes. Under the optimum extraction conditions, the method shows broad linear ranges for the target analytes. Enrichment factors and limits of detection for the selected pesticides are obtained in the ranges of 3480–3800 and 0.1–5 μg L−1, respectively. Relative standard deviations are in the range of 2–7% (n = 6, C = 50 or 100 μg L−1, each analyte). Finally, some aqueous samples were successfully analyzed using the developed method.  相似文献   
36.
The paper proposes a simple and portable approach for the surface enhanced Raman scattering (SERS) spectroscopy in situ determination of carboxylated single walled carbon nanotubes (SWNTs) in river water samples. The method is based on the subsequent microfiltration of a bare gold nanoparticles solution and the water sample containing soluble carbon nanotubes by using a home-made filtration device with a small filtration diameter. An acetate cellulose membrane with a pore size of 0.2 μm first traps gold nanoparticles to form the SERS-active substrate and then concentrates the carbon nanotubes. The measured SERS intensity data were closely fit with a Langmuir isotherm. A portable Raman spectrometer was employed to measure SERS spectra, which enables in situ determination of SWNTs in river waters. The limit of detection was 10 μg L−1. The precision, for a 10 mg L−1 concentration of carbon nanotubes, is 1.19% intra-membrane and 10.5% inter-membrane.  相似文献   
37.
Macronutrient elements (C, N and P) and micronutrient elements (Fe, Co, Cu, Zn and Mn) are widely measured in their various physico-chemical forms in open ocean, shelf sea, coastal and estuarine waters. These measurements help to elucidate the biogeochemical cycling of these elements in marine waters and highlight the ecological and socio-economic importance of the oceans. Due to the dynamic nature of marine waters in terms of chemical, biological and physical processes, it is advantageous to make these measurements in situ and in this regard flow injection analysis (FIA) provides a suitable shipboard platform. This review, therefore, discusses the role of FIA in the determination of macro- and micro-nutrient elements, with an emphasis on manifold design and detection strategies for the reliable shipboard determination of specific nutrient species. The application of various FIA manifolds to oceanographic nutrient determinations is discussed, with an emphasis on sensitivity, selectivity, high throughput analysis and suitability for underway analysis and depth profiles. Strategies for enhancing sensitivity and minimizing matrix effects, e.g. refractive index (schlieren) effects and the important role of uncertainty budgets in underpinning method validation and data quality are discussed in some detail.  相似文献   
38.
39.
Shen Y  Qi L  Qin J  Yan H  Qiao J  Zhang H  Chen Y  Mao L  Wan L 《Talanta》2011,84(2):501-507
A new amphipathic block copolymer, poly(tert-butyl acrylate)127-block-poly(glycidyl methacrylate)86, was developed for the coating in open tubular capillary electrochromatography. The self-assembly characters of the coating, which could form micelle-like aggregates under proper conditions, were observed by atomic force microscopy. Compared with bare capillary, this coating could act as surfactant and lead to improve the separation of steroids. In addition, the influence of pH, buffer concentration and organic solvents on the separation was investigated. The best separation of the three model steroid analytes could be achieved using 20.0 mM borate buffer at pH 10.5. For covalent bonding, the coating showed good repeatability and stability with RSD of uEOF less than 3.3%. Then, this proposed method was well validated with good linearity (≥0.999), recovery (91.0-94.0%) and repeatability, and was successfully used for separation of steroids in spiked serum samples, which indicated that this new OT-CEC method could provide a potential tool to determine steroids in real biological system without interference.  相似文献   
40.
A reversible and regenerable electrochemical biosensor is fabricated for quantitative detection of antibody based on “triplex-stem” molecular switches. A hairpin-shaped oligonucleotide (hairpin DNA) labeled with ferrocene (Fc) at the 3′-end is fixed on the gold electrode serving as a signal transduction probe. Its hairpin structure leads Fc close to the surface of gold electrode and produces a strong current signal (on-state). A single-strand oligonucleotide modified with two digoxin molecules on the two arm segments (capture DNA) interact with hairpin DNA with the help of Ag+ ions. The “triplex-stem” DNA forms, which separates Fc from the electrode and reduces the electrochemical signal (off-state). Binding of digoxin antibody to digoxin releases capture DNA from the hairpin DNA, creating an effective “off-on” current signal switch. The stability of the “triplex-stem” structure of hairpin/capture DNA is critical to the signal switch and the sensitivity of the method, which can be adjusted conveniently and efficiently by changing Ag+ concentrations. Based on the “off-on” current signal switch, this biosensor is used to detect digoxin antibody sensitively in blood serum. The linear range is 1.0–500 pg with a correlation coefficient of 0.996, and the detection limit is 0.4 pg. Also, this biosensor shows excellent reversibility and reproducibility, which are significant requirements for practical biosensor applications.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号