首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Pretreatment of silica gel sample containing 1-naphthylamine by microwave-assisted desorption (MAD) coupled to in situ headspace solid phase microextraction (HS-SPME) has been investigated as a possible alternative to conventional methods prior to gas chromatographic (GC) analysis. The 1-naphthylamine desorbs from silica gel to headspace under microwave irradiation, and directly absorbs onto a SPME fiber located in a controlled-temperature headspace area. After being collected on the SPME fiber, and desorbed in the GC injection port, 1-naphthylamine is analyzed by GC-FID. Parameters that influence the extraction efficiency of the MAD/HS-SPME, such as the extraction media and its pH, the microwave irradiation power and irradiation time as well as desorption conditions of the GC injector, have been investigated. Experimental results indicate that the extraction of a 150 mg silica gel sample by using 0.8 ml of 1.0 M NaOH solution and a PDMS/DVB fiber under high-powered irradiation (477 W) for 5 min maximizes the extraction efficiency. Desorption of 1-naphthylamine from the SPME fiber in GC injector is optimal at 250 °C held for 3 min. The detection limit of method is 8.30 ng. The detected quantity of 1-naphthylamine obtained by the proposed method is 33.3 times of that obtained by the conventional solvent extraction method for the silica gel sample containing 100 ng of 1-naphthylamine. It provides a simple, fast, sensitive and organic-solvent-free pretreatment procedure prior to the analysis of 1-naphthylamine collected on a silica gel adsorbent.  相似文献   

2.
Formaldehyde dimethylhydrazone (FADMH) is one of the important transformation products of residual rocket fuel 1,1-dimethylhydrazine (1,1-DMH). Thus, recent studies show that FADMH toxicity is comparable to that of undecomposed 1,1-DMH. In this study, a new method for quantification of FADMH in water based on solid phase microextraction (SPME) in combination with gas chromatography (GC) with mass spectrometric (MS) and nitrogen-phosphorus detection (NPD) is presented. Effects of SPME fiber coating type, extraction and desorption temperatures, extraction time, and pH on analyte recovery were studied. The optimized method used 65 micron polydimethylsiloxane/divinylbenzene fiber coating for 1?min headspace extractions at 30?°C. Preferred pH and desorption temperature from the SPME fiber are >8.5 and 200?°C, respectively. Detection limits were estimated to be 1.5 and 0.5?μg?L(-1) for MS and NPD, respectively. The method was applied to laboratory-scale experiments to quantify FADMH. Results indicate applicability for in situ sampling and analysis and possible first-time detection of free FADMH in water.  相似文献   

3.
Solid‐phase microextraction (SPME) has been directly coupled to an ion‐trap mass spectrometer (MS) for the determination of the model compound lidocaine in urine, hereby applying MS/MS [fragmentation of [M + H]+ (m/z 235) to a fragment with m/z 86]. The throughput of samples has been increased using non‐equilibrium SPME with polydimethylsiloxane (PDMS) fibers. The effect of temperature on the sorption and the desorption was studied. Elevated temperatures during sorption (65°C) and desorption (55°C) had a considerable influence on the speed of the extraction. The desorption was carried out with a home‐made desorption chamber allowing thermostating. Only 1 min sorption and 1 min desorption were performed, after which MS detection took place, resulting in a total analysis time of 3 min. Detection limits below 1 ng/mL could be obtained despite yields of only 2.1 and 1.5% for a 100‐ and a 30‐μm PDMS‐coated fiber, respectively. Furthermore, the determination of lidocaine in urine had acceptable reproducibilities, i.e., relative standard deviations (RSDs) below 10%. A limit of quantitation (RSD < 15%) of about 1 ng/mL was obtained. No extra wash step of the extraction fiber was required after desorption if a 30‐μm coating was used, whereas not all the analyte was desorbed from the 100‐μm coating in a single desorption. Therefore, the SPME‐MS/MS system with a 30‐μm PDMS‐coated fiber for rapid non‐equilibrium SPME at elevated temperatures has interesting potential for high‐throughput analysis of biological samples.  相似文献   

4.
Ming-Chi Wei 《Talanta》2007,72(4):1269-1274
The novel pretreatment technique, microwave-assisted heating coupled to headspace solid-phase microextraction (MA-HS-SPME) has been studied for one-step in situ sample preparation for polycyclic aromatic hydrocarbons (PAHs) in aqueous samples before gas chromatography/flame ionization detection (GC/FID). The PAHs evaporated into headspace with the water by microwave irradiation, and absorbed directly on a SPME fiber in the headspace. After being desorbed from the SPME fiber in the GC injection port, PAHs were analyzed by GC/FID. Parameters affecting extraction efficiency, such as SPME fiber coating, adsorption temperature, microwave power and irradiation time, and desorption conditions were investigated.Experimental results indicated that extraction of 20 mL aqueous sample containing PAHs at optional pH, by microwave irradiation with effective power 145 W for 30 min (the same as the extraction time), and collection with a 65 μm PDMS/DVB fiber at 20 °C circular cooling water to control sampling temperature, resulted in the best extraction efficiency. Optimum desorption of PAHs from the SPME fiber in the GC hot injection port was achieved at 290 °C for 5 min. The method was developed using spiked water sample such as field water with a range of 0.1-200 μg/L PAHs. Detection limits varied from 0.03 to 1.0 μg/L for different PAHs based on S/N = 3 and the relative standard deviations for repeatability were <13%. A real sample was collected from the scrubber water of an incineration system. PAHs of two to three rings were measured with concentrations varied from 0.35 to 7.53 μg/L. Recovery was more than 88% and R.S.D. was less than 17%. The proposed method is a simple, rapid, and organic solvent-free procedure for determination of PAHs in wastewater.  相似文献   

5.
Yan CT  Shih TS  Jen JF 《Talanta》2004,64(3):650-654
Microwave-assisted desorption (MAD) coupled to in situ headspace solid-phase microextraction (HS-SPME) was first proposed as a possible alternative pretreatment of samples in absorbent collected from workplace monitoring. Aniline collected on silica gel was investigated. Under microwave irradiation, the aniline was desorbed from silica gel and directly absorbed onto the SPME fiber in the headspace. Having been sampled on the SPME fiber, and desorbed in the GC injection port, aniline was analyzed using a GC-FID system. Parameters that affect the proposed extraction efficiency, including the extraction media and its pH, the microwave irradiation power and the irradiation time as well as desorption parameters of the GC injector, were investigated. Experimental results revealed that the extraction of a 150-mg silica gel sample using a 0.8-ml aqueous solution (pH 12) and a PDMS/DVB fiber under medium-high-powered irradiation (345 W) for 3 min maximized the efficiency of extraction. Desorption of aniline from the SPME fiber was optimal at 230 °C held for 3 min. The detection limit was 0.09 ng. The proposed method provided a simple, fast, and organic solvent-free procedure to analyze aniline from a silica gel matrix.  相似文献   

6.
建立了顶空固相微萃取(HS-SPME)/气相色谱-质谱(GC-MS)同时测定液态化妆品中8种邻苯二甲酸酯类增塑剂(PAEs)的分析方法,并对萃取涂层、萃取温度、搅拌速率、盐浓度等参数进行了优化。最终采用65μm聚二甲基硅氧烷/二乙烯基苯(PDMS/DVB)固相微萃取纤维头,调节待萃取液盐浓度为360 g.L-1,在搅拌速率600 r/min及萃取温度90℃条件下萃取60 min,在250℃进样口解吸4 min后供GC-MS分析。结果表明,该方法对除邻苯二甲酸二苯酯(DPhP)外的7种目标化合物的线性范围为10~2 000μg.kg-1,检出限为0.7~13.6μg.kg-1,回收率为83%~97%,相对标准偏差(RSD)为2.5%~10.0%;由于DPhP在萃取涂层上的保留较弱,其回收率为70%,检出限为75μg.kg-1,RSD为13.9%。该方法能很好地富集基体中的目标化合物,满足液态化妆品中多种PAEs的分析要求。  相似文献   

7.
A new method is described for the qualitative and quantitative analysis of cyanide, a very short-acting and powerful toxic agent, in human whole blood. It involves the conversion of cyanide into hydrogen cyanide and its subsequent headspace solid-phase microextraction (HS-SPME) and detection by gas chromatography/mass spectrometry (GC/MS) in selected ion monitoring (SIM) mode. Optimizing the conditions for the GC/MS (type of column, injection conditions, temperature program) and SPME (choice of SPME fiber, effect of salts, adsorption and desorption times, adsorption temperature) led to the choice of a 75-microm carboxen/polydimethylsiloxane SPME fiber, with D3-acetonitrile as internal standard, and a capillary GC column with a polar stationary phase. Method validation was carried out in terms of linearity, precision and accuracy in both aqueous solutions and blood. The limit of detection (LOD) and limit of quantitation (LOQ) were determined only in aqueous solutions. The assay is linear over three orders of magnitude (water 0.01-10, blood 0.05-10 microg/mL); and the LOD and LOQ in water were 0.006 and 0.01 microg/mL, respectively. Good intra- and inter-assay precision was obtained, always <8%. The method is simple, fast and sensitive enough for the rapid diagnosis of cyanide intoxication in clinical and forensic toxicology.  相似文献   

8.
A solid-phase microextraction (SPME) procedure has been developed for the determination of 16 US Environmental Protection Agency promulgated polycyclic aromatic hydrocarbons (PAHs). Five kinds of SPME fibers were used and compared in this study. The extracted sample was analyzed by gas chromatography with flame ionization detection or mass spectrometry. Parameters affecting the sorption of analyte into the fibers, including sampling time, thickness of the fiber coating, and the effect of temperature, have been examined. Moreover, the feasibility of headspace SPME with different working temperatures was evaluated. The method was also applied to real samples. The 85-microm polyacrylate (PA) and 100-microm poly(dimethylsiloxane) (PDMS) fibers were shown to have the highest affinities for the selected PAHs. The PA fiber was more suitable than the PDMS fiber for the determination of low-ring PAHs while high sensitivity of high-ring PAHs was observed when a 100-microm PDMS fiber was used. The method showed good linearity between 0.1 and 100 ng/ml with regression coefficients ranging from 0.94 to 0.999. The reproducibility of the measurements between fibers was found to be very good. The precisions of PA and PDMS fibers were from 3 to 24% and from 3 to 14%, respectively. Headspace SPME is a valid alternative for the determination of two- to five-ring PAHs. A working temperature of 60 degrees C provides significant enhancement in sensitivity of two- to five-ring PAHs having low vapor pressures (>10(-6) mmHg at 25 degrees C) (1 mmHg = 133.3 Pa) and low Henry's constants (>10 atm ml/mol) (1 atm = 1.01 x 10(5) Pa).  相似文献   

9.
The solid‐phase microextraction (SPME) technique using a 100 μm film polydimethylsiloxane (PDMS) coated fiber has been examined with the aim to determine dichlorobenzene in aqueous samples. The feasibility of SPME‐GC‐ECD analysis has been evaluated. Absorption time of 30 min was selected and 1 min was long enough for complete desorption of the analytes in the injection port of the gas chromatograph. Linear ranges from 0.03 to 5 μg/L and method detection limits between 7 and 9 ng/L for dichlorobenzenes were obtained. The relative standard deviations were less than 12% for a spiking level of 3 μg/L. The proposed method was applied to determine dichlorobenzenes in spiked deionized water, ground water, and in industrial effluent samples.  相似文献   

10.
溶胶-凝胶固相微萃取涂层及其在农药残留分析中的应用   总被引:1,自引:0,他引:1  
利用溶胶-凝胶(sol-gel)技术制备固相微萃取(SPME)涂层材料.通过硅醇盐前驱体与涂层聚合物羟基硅油(OH-TSO)的水解共聚的方法,成功地制备了聚二甲基硅氧烷sol-gel 涂层的SPME 萃取头,并以农药的混合标准水溶液为研究对象,用直接-固相微萃取-气相色谱法(GC)对涂层的性能进行考察,制成的萃取头适用于多种农药残留的萃取分离分析.  相似文献   

11.
自制固相微萃取装置对水中5种农药残留量的分析   总被引:2,自引:0,他引:2  
合成了一种丙烯酸酯聚合物,并将其作为固相微萃取涂层,使用自制的SPME装置和气质联用仪对水样中5种农药残留量进行分析,该装置制作简单、价格低廉.对影响分析灵敏度的各种实验因素进行了优化,在优化条件下分析5种农药标准样品质量浓度在1~1000 μg/L内与色谱峰面积呈良好的线性关系(r=0.995~0.999),检出限为0.391~1.170 ng/L.将自制涂层与商品涂层(PA)进行了比较,自制涂层对5种农药具有优良的吸附特性,较低的检出限.  相似文献   

12.
Methylation of carboxylic acids upon syringe injection of a mixture of the acid sample and phenyltrimethylammonium hydroxide (PTMAH) into the GC injection port is a convenient but under-utilized derivatization procedure. To minimize potential instrumental problems due to the sample matrix, it was shown that solid-phase microextraction (SPME) is effective for the absorption of both the carboxylic acid (RCOOH) and PTMAH permitting on-line methylation from the fiber. A comparison of three fibers, polydimethylsiloxane (PDMS), polyacrylate (PA), and carboxene/PDMS for decanoic and stearic acids showed the carboxene/PDMS fiber was about five times more effective for the extraction of the RCOOH-PTMAH mixture dissolved in methanol. The optimum fiber absorption time was about 20 min and the optimum desorption time in the injection port held at 280 degrees C was about 5-10 min. The optimum PTMAH/RCOOH ratio was about 125:1. Linearity for C18:0 at 3.3 x 10(-6)-3.3 x 10(-4) M was demonstrated by GC-MS with a detection limit of 1 microM. This SPME method is also effective for the methylation of C18:1, C18:2, and C18:3 fatty acids. Transesterification of olive oil using PTMAH and then on-line methylation either by the syringe method or by SPME gave comparable fatty acid methyl ester profiles.  相似文献   

13.
The use of two modes for mass spectrometry (MS) detection with an ion trap instrument, selected ion storage (SIS) and tandem mass spectrometry (MS/MS), are compared for the solid-phase microextraction (SPME)–gas chromatography (GC) coupled to mass spectrometry (GC-MS) determination of 16 priority organochlorine pesticides (OCPs) in drinking water samples at the ultratrace levels (ng?L?1) required by official guidelines in the European legislation. Experimental parameters investigated for the SPME sample preparation were: the type of coating (100?µm polydimethylsiloxane, PDMS, and 65?µm poly(dimethylsiloxane)–divinylbenzene, PDMS/DVB), SPME modality, extraction and desorption times and desorption temperature and the methanol percentage in the SPME working solution. Under the calculated optimal conditions two methodologies were developed, one for SIS and the other for MS/MS modes. The detection limits, precision and accuracy were evaluated for both alternatives and were appropriate to the official guidelines requirements. The SPME–GC-MS(SIS) methodology offered LODs from 0.2–6.6?ng?L?1, precision below 13% and recoveries between 83 and 110%. The SPME–GC–MS/MS methodology provided limits of detection (LODs) ranging from 0.3 to 7.6 ng?L?1, % RSD were ≤14% and recoveries of 79–108% were achieved. After the results observed within an Interlaboratory Exercise, the latest MS methodology was selected for the pursued analysis in real drinking water samples. Also, the good results in this round-robin exercise validate the proposed SPME–GC–MS/MS methodology.  相似文献   

14.
固相微萃取气相色谱法测定水相中邻苯二甲酸二酯   总被引:4,自引:0,他引:4  
刘振岭  肖春华  吴采樱  韩惠敏 《色谱》2000,18(6):568-570
 采用m(聚硅氧烷 (OV 1) )∶m (富勒烯聚二甲基硅氧烷 (PSO C60 ) ) =4∶1的混合固定相自制萃取头 ,利用顶空固相微萃取与气相色谱联用技术 (HS SPME GC)分析了水中 5种邻苯二甲酸二酯。考察了萃取温度、离子强度、吸附和热解吸时间等因素对该方法灵敏度的影响。结果表明该萃取头萃取选择性优于商用PDMS萃取头。方法的检出限为 0 331ng/L~ 12 5 μg/L ;除邻苯二甲酸二正壬酯外 ,相对标准偏差均在 12 %以下。  相似文献   

15.
Determination of aniline in wastewater was investigated by microwave-assisted headspace solid-phase microextraction (MA-HS-SPME), for one-step in-situ sample preparation, and gas chromatography. Aniline in the water was evaporated into the headspace under the action of microwave irradiation and adsorbed directly by the SPME fiber. After desorption in the GC injection port and gas chromatography aniline was detected by FID. Conditions affecting the extraction efficiency, for example the pH of the water, addition of salt, microwave power and irradiation time, and desorption conditions were investigated. Experimental results indicated that adjustment of the pH of the water sample to 12 and headspace SPME sampling with a PDMS-DVB fiber under medium–high power irradiation (345 W) for 3 min resulted in the best extraction efficiency. Desorption of aniline was optimum when the SPME fiber was heated at 230 °C for 3 min. The detection limit was approximately 0.01 g mL–1. The proposed method is a simple, fast, and organic-solvent-free procedure for analysis of aniline in water. Application was illustrated by analysis of aniline in wastewater from a polymer factory.  相似文献   

16.
固相微萃取-气相色谱/质谱分析栀子花的头香成分   总被引:30,自引:0,他引:30  
刘百战  高芸 《色谱》2000,18(5):452-455
 分别用固相微萃取和动态顶空法分离栀子鲜花的头香成分,用GC/MS技术分析鉴定,并用GC/MS总离子流色谱峰的峰面积进行归一化定量。在固相微萃取方法中,共鉴定了54种化学成分,占总峰面积的99.98%。主要成分(质量分数)依次为金合欢烯(64.86%)、罗勒烯(29.33%)、芳樟醇(2.74%)、惕各酸顺式叶醇酯(1.34%)和苯甲酸甲酯(0.25%)等。经与动态顶空法的分析结果比较发现,固相微萃取法不仅操作简便,而且具有较高的采样灵敏度,获得的化学成分的信息量多于动态顶空法。  相似文献   

17.
F Lestremau  V Desauziers  J L Fanlo 《The Analyst》2001,126(11):1969-1973
Solid-phase micro extraction (SPME) is a promising technique for fast and low cost trace analysis. However, some limitations of the technique were encountered when using a PDMS (polydimethylsiloxane)/Carboxen fibre for sampling a mixture of volatile aliphatic amines in air. On the GC chromatogram, two supplementary peaks were noticed in addition to the analyte peaks, thus limiting qualitative and quantitative analysis in this particular case. This paper presents the investigations to identify the artefacts and determine the origin of their formation. First, GC-MS identification, by both electron impact and chemical ionisation modes, demonstrated that the two artefacts were unsaturated amines assumed to be formed by a dehydrogenation reaction of the target amines. This reaction was found to occur during thermal desorption of analytes in the GC injection port and to be catalysed by temperature and by metals consisting of the inox (stainless-steel) needle of the SPME device. It was also demonstrated that artefact formation was not significant when using PDMS or PDMS/divinylbenzene fibres. This difference with PDMS/Carboxen fibre can be explained by the high desorption temperature required for this fibre. Moreover, the microporosity of Carboxen induces a longer desorption time which increases the contact between analytes and inox and thereby enhances artefact formation.  相似文献   

18.
In this study, a simple, rapid, and sensitive method was developed and validated for the quantification of valproic acid (VPA), an antiepileptic drug, in human plasma, which was based on water-phase derivatization followed by headspace solid-phase microextraction (HS-SPME) and gas chromatography/mass spectrometry (GC/MS). In the proposed method, VPA in plasma was rapidly derivatized with a mixture of isobutyl chloroformate, ethanol and pyridine under mild conditions (room temperature, aqueous medium), and the VPA ethyl ester formed was headspace-extracted and simultaneously concentrated using the SPME technique. Finally, the analyte extracted on SPME fiber was analyzed by GC/MS. The experimental parameters and method validations were studied. The optimal conditions were obtained: PDMS fiber, stirring rate of 1100 rpm, sample temperature of 80 degrees C, extraction time of 20 min, NaCl concentration of 30%. The proposed method had a limit of quantification (0.3 microg/mL), good recovery (89-97%) and precision (RSD value less than 10%). Because the proposed method combined a rapid water-phase derivatization with a fast, simple and solvent-free sample extraction and concentration technique of SPME, the sample preparation time was less than 25 min. This much shortens the whole analysis time of VPA in plasma. The validated method has been successfully used to analyze VPA in human plasma samples for application in pharmacokinetic studies. All these results show that water-phase derivatization followed by HS-SPME and GC/MS is an alternative and powerful method for fast determination of VPA in biological fluids.  相似文献   

19.
An application of the direct coupling of solid-phase microextraction (SPME) with mass spectrometry (MS), a technique known as fiber introduction mass spectrometry (FIMS), is described to determine organochlorine (OCP) and organophosphorus (OPP) pesticides in herbal infusions of Passiflora L. A new fiber coated with a composite of poly(dimethylsiloxane) and poly(vinyl alcohol) (PDMS/PVA) was used. Sensitive, selective, simple and simultaneous quantification of several OCP and OPP was achieved by monitoring diagnostic fragment ions of m/z 266 (chlorothalonil), m/z 195 (alpha-endosulfan), m/z 278 (fenthion), m/z 263 (methyl parathion) and m/z 173 (malathion). Simple headspace SPME extraction (25 min) and fast FIMS detection (less than 40 s) of OCP and OPP from a highly complex herbal matrix provided good linearity with correlation coefficients of 0.991-0.999 for concentrations ranging from 10 to 140 ng ml(-1) of each compound. Good accuracy (80 to 110%), precision (0.6-14.9%) and low limits of detection (0.3-3.9 ng ml(-1)) were also obtained. Even after 400 desorption cycles inside the ionization source of the mass spectrometer, no visible degradation of the novel PDMS/PVA fiber was detected, confirming its suitability for FIMS. Fast (ca 20 s) pesticide desorption occurs for the PDMS/PVA fiber owing to the small thickness of the film and its reduced water sorption.  相似文献   

20.
An application of the direct coupling of solid-phase microextraction (SPME) with mass spectrometry (MS), a technique known as fiber introduction mass spectrometry (FIMS), is described to determine organochlorine (OCP) and organophosphorus (OPP) pesticides in herbal infusions of Passiflora L. A new fiber coated with a composite of poly(dimethylsiloxane) and poly(vinyl alcohol) (PDMS/PVA) was used. Sensitive, selective, simple and simultaneous quantification of several OCP and OPP was achieved by monitoring diagnostic fragment ions of m/z 266 (chlorothalonil), m/z 195 (alpha-endosulfan), m/z 278 (fenthion), m/z 263 (methyl parathion) and m/z 173 (malathion). Simple headspace SPME extraction (25 min) and fast FIMS detection (less than 40 s) of OCP and OPP from a highly complex herbal matrix provided good linearity with correlation coefficients of 0.991-0.999 for concentrations ranging from 10 to 140 ng ml(-1) of each compound. Good accuracy (80 to 110%), precision (0.6-14.9%) and low limits of detection (0.3-3.9 ng ml(-1)) were also obtained. Even after 400 desorption cycles inside the ionization source of the mass spectrometer, no visible degradation of the novel PDMS/PVA fiber was detected, confirming its suitability for FIMS. Fast (ca 20 s) pesticide desorption occurs for the PDMS/PVA fiber owing to the small thickness of the film and its reduced water sorption.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号