1.
A new type of electron ionization LC‐MS with supersonic molecular beams (EI‐LC‐MS with SMB) is described. This system and its operational methods are based on pneumatic spray formation of the LC liquid flow in a heated spray vaporization chamber, full sample thermal vaporization and subsequent electron ionization of vibrationally cold molecules in supersonic molecular beams. The vaporized sample compounds are transferred into a supersonic nozzle via a flow restrictor capillary. Consequently, while the pneumatic spray is formed and vaporized at above atmospheric pressure the supersonic nozzle backing pressure is about 0.15 Bar for the formation of supersonic molecular beams with vibrationally cold sample molecules without cluster formation with the solvent vapor. The sample compounds are ionized in a fly‐though EI ion source as vibrationally cold molecules in the SMB, resulting in ‘Cold EI’ (EI of vibrationally cold molecules) mass spectra that exhibit the standard EI fragments combined with enhanced molecular ions. We evaluated the EI‐LC‐MS with SMB system and demonstrated its effectiveness in NIST library sample identification which is complemented with the availability of enhanced molecular ions. The EI‐LC‐MS with SMB system is characterized by linear response of five orders of magnitude and uniform compound independent response including for non‐polar compounds. This feature improves sample quantitation that can be approximated without compound specific calibration. Cold EI, like EI, is free from ion suppression and/or enhancement effects (that plague ESI and/or APCI) which facilitate faster LC separation because full separation is not essential. The absence of ion suppression effects enables the exploration of fast flow injection MS‐MS as an alternative to lengthy LC‐MS analysis. These features are demonstrated in a few examples, and the analysis of the main ingredients of Cannabis on a few Cannabis flower extracts is demonstrated. Finally, the advantages of EI‐LC‐MS with SMB are listed and discussed. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

2.
Gas chromatography–mass spectrometry (GC–MS) with Cold EI is based on interfacing GC and MS with supersonic molecular beams (SMBs) along with electron ionization of vibrationally cold sample compounds in SMB in a fly-through ion source (hence the name Cold EI). Cold EI improves all the central performance aspects of GC–MS, and in this paper, we focus on its improvement of signal-to-noise ratio (S/N) and limits of detection (LODs). We found that the harder the compound for analysis with standard EI, the greater the Cold EI gain in S/N and LOD. The lower LOD and higher S/N of Cold EI emerge from a few reasons: (a) similar ionization yield as standard EI, (b) enhanced abundance of molecular ions, (c) elimination of vacuum background noise, (d) elimination of ion source-related peak tailing and degradation, (e) ability to lower the elution temperatures via the use of high column flow rates, and (f) greater range of thermally labile and low-volatility compounds that can be analyzed. We demonstrate the superior S/N and lower LOD of Cold EI versus standard EI in a range of compounds, from the simple-to-analyze octafluoronaphthalene all the way to reserpine and an organo-metallic compound that cannot be analyzed by standard EI. These compounds include methyl stearate, cholesterol, n-C32H66, large polycyclic aromatic hydrocarbons, dioctyl phthalates, diundecyl phthalate, pentachlorophenol, benzidine, lambda-cyhalothrin, and methidathion. The significantly lower Cold EI LODs that can be over 1000 times better than in standard EI further result in far superior response linearity and greater measurement dynamic range.  相似文献   

3.
Keshet  Uri  Fialkov  Alexander B.  Alon  Tal  Amirav  Aviv 《Chromatographia》2016,79(11):741-754

We designed and operated a new system of pulsed flow modulation (PFM) two dimensional comprehensive gas chromatography (GC × GC) mass spectrometry (MS). This system is based on the combination of PFM–GC × GC with a quadrupole mass spectrometer of GC–MS via a supersonic molecular beams interface and its fly-through Cold EI ion source and applied this system for the analysis of JP8 jet fuel. PFM is a simple GC × GC modulator that does not consume cryogenic gases while providing tunable second GC × GC column injection time for enabling the use of quadrupole based mass spectrometry regardless its limited scanning speed. We analyzed JP8 jet fuel with our new PFM–GC × GC–MS with Cold EI system and found that as the second dimension GC elution time is increased the observed molecular ion mass is reduced. This unique observation that helped in improved sample compounds identification under co-elution conditions was enabled via having abundant molecular ions in Cold EI for all the fuel compounds. We named this type of analysis as PFM–GC × GC × MS. We found and discuss in this paper that PFM–GC × GC–MS with Cold EI combines improved separation of GC × GC with Cold EI benefits of tailing-free ultra-fast ion source response time and enhanced molecular ions and mass spectral isomer and isotope information for the provision of increased sample identification information.

  相似文献   

4.
Electron ionization (EI) mass spectra of 46 compounds from several different compound classes were measured. Their molecular ion abundances were compared as obtained with 70‐eV EI, with low eV EI (such as 14 eV), and with EI mass spectra of vibrationally cold molecules in supersonic molecular beams (Cold EI). We further compared these mass spectra in their National Institute of Standards and Technology (NIST) library identification probabilities. We found that
  1. Low eV EI is not a soft ionization method, and it has little or no influence on the molecular ion relative abundances for large molecules and those with weak or no molecular ions.
  2. Low eV EI for compounds with abundant or dominant molecular ions in their 70 eV mass spectra results in the reduction of low mass fragment ions abundances thereby reducing their NIST library identification probabilities thus rarely justifies its use in real‐world applications.
  3. Cold EI significantly enhances the relative abundance of the molecular ions particularly for large compounds; yet, it retains the low mass fragment ions; hence, Cold EI mass spectra can be effectively identified by the NIST library.
  4. Different standard EI ion sources provide different 70 eV EI mass spectra. Among the Agilent technologies ion sources, the “Extractor” exhibits relatively abundant molecular ions compared with the “Inert” ion source, while the “High efficiency source” (HES) provides mass spectra with depleted molecular ions compared with the “Inert” ion source or NIST library mass spectra.
These conclusions are demonstrated and supported by experimental data in nine figures and two tables.  相似文献   

5.
Gas chromatography-mass spectrometry (GC-MS) with supersonic molecular beams (SMBs) (also named Supersonic GC-MS) is based on GC and MS interface with SMBs and on the electron ionization (EI) of vibrationally cold analytes in the SMBs (cold EI) in a fly-through ion source. This ion source is inherently inert and further characterized by fast response and vacuum background filtration capability. The same ion source offers three modes of ionization including cold EI, classical EI and cluster chemical ionization (CI). Cold EI, as a main mode, provides enhanced molecular ions combined with an effective library sample identification, which is supplemented and complemented by a powerful isotope abundance analysis method and software. The range of low-volatility and thermally labile compounds amenable for analysis is significantly increased owing to the use of the contact-free, fly-through ion source and the ability to lower sample elution temperatures through the use of high column carrier gas flow rates. Effective, fast GC-MS is enabled particularly owing to the possible use of high column flow rates and improved system selectivity in view of the enhancement of the molecular ion. This fast GC-MS with SMB can be further improved via the added selectivity of MS-MS, which by itself benefits from the enhancement of the molecular ion, the most suitable parent ion for MS-MS. Supersonic GC-MS is characterized by low limits of detection (LOD), and its sensitivity is superior to that of standard GC-MS, particularly for samples that are hard for analysis. The GC separation of the Supersonic GC-MS can be improved with pulsed flow modulation (PFM) GC x GC-MS. Electron ionization LC-MS with SMB can also be combined with the Supersonic GC-MS, with fast and easy switching between these two modes of operation.  相似文献   

6.
A new gas chromatography/mass spectrometry (GC/MS) system was designed and evaluated which we have named 'Supersonic GC/MS'. It is based on a modification of a commercially available GC/MS system to include a supersonic molecular beam (SMB) MS interface. In this system the standard electron ionization (EI) ion source was replaced with a fly-through EI ion source mounted in the path of the SMB. A hyperthermal surface ionization (HSI) ion source combined with a 90 degrees ion mirror (for the EI-produced ions) was also added, and placed inside the quadrupole mass analyzer in place of its original EI ion source. The 'Supersonic GC/MS' system requires 18 cm added bench space plus the addition of an air-cooled 60 L/s diffusion pump and a 537 L/min rotary pump. The system is user friendly since all the gas flow rates, heated zones, sampling and data analysis are performed the same way as the original system and are computer-controlled via the original software. Similar EI sensitivity was obtained as with the original system for hexachlorobenzene and octafluoronaphthalene, while improved EI detection limits were demonstrated for methyl stearate and eicosane due to the significant enhancement of their molecular ion abundances. A GC/MS detection limit of 500 ag for pyrene was demonstrated using HSI. Good supersonic expansion cooling was achieved with large alkanes, despite the use of a rotary pump at the nozzle chamber instead of a diffusion pump. High temperature GC/MS analysis was demonstrated for large polycyclic aromatic hydrocarbons (PAHs) including ovalene and decacyclene (ten rings). Library searches with EI mass spectra are demonstrated, and it is explained why the enhancement of the molecular ion actually improves the library search in most cases. The analysis of large phthalate esters is also described, and the improvement obtained is shown to originate from their enhanced molecular and high mass fragment ions.  相似文献   

7.
A major benefit of gas chromatography/mass spectrometry (GC/MS) with a supersonic molecular beam (SMB) interface and its fly-through ion source is the ability to obtain electron ionization of vibrationally cold molecules (cold EI), which show enhanced molecular ions. However, GC/MS with an SMB also has the flexibility to perform 'classical EI' mode of operation which provides mass spectra to mimic those in commercial 70 eV electron ionization MS libraries. Classical EI in SMB is obtained through simple reduction of the helium make-up gas flow rate, which reduces the SMB cooling efficiency; hence the vibrational temperatures of the molecules are similar to those in traditional EI ion sources. In classical EI-SMB mode, the relative abundance of the molecular ion can be tuned and, as a result, excellent identification probabilities and very good matching factors to the NIST MS library are obtained. Classical EI-SMB with the fly-through dual cage ion source has analyte sensitivity similar to that of the standard EI ion source of a basic GC/MS system. The fly-through EI ion source in combination with the SMB interface can serve for cold EI, classical EI-SMB, and cluster chemical ionization (CCI) modes of operation, all easily exchangeable through a simple and quick change (not involving hardware). Furthermore, the fly-through ion source eliminates sample scattering from the walls of the ion source, and thus it offers full sample inertness, tailing-free operation, and no ion-molecule reaction interferences. It is also robust and enables increased column flow rate capability without affecting the sensitivity.  相似文献   

8.
The determination of 14 N-nitrosamines by a supersonic molecular beam electron ionization mass spectrometer equipped with triple quadruple analyzer, GC/SMB/EI/QQQ/MS is presented. The supersonic molecular beam electron ionization ion source allows the elucidation of the molecular ion of 13 out of the 14 examined nitrosamines (except for diphenylnitrosamine which was degraded before the analysis). It was possible to use the molecular ions of all the nitrosamines as the parent ions for multiple reactions monitoring mode, which in turn allows significant increase of specificity and lowering of the method limit of detection of the higher molecular weight nitrosamines. The instrumental LOD for different N-nitrosamines was 1–5 pg injection−1. The proposed method was exemplified by analysis of N-nitrosamines and N-nitrosatables in rubber teats according to the British Standard BS EN 12868:1999.  相似文献   

9.
Gas chromatography–mass spectrometry (GC-MS) with Cold EI is based on interfacing GC and MS with a supersonic molecular beam (SMB) and sample compounds ionization with a fly-through ion source as vibrationally cold compounds in the SMB (hence the name Cold EI). We explored the use of nitrogen and hydrogen as carrier and make-up gases with Cold EI and found:
  1. Nitrogen is very effective in cooling compounds in SMB and while helium requires 60 ml/min nitrogen provides effective cooling with only 7–8 ml/min combined column and make-up flow rate. Hydrogen is less effective than helium and requires higher flow rates.
  2. The transition from helium to nitrogen (or hydrogen) is simple and fast and requires just closing the helium valve and opening the nitrogen valve.
  3. The same column used with helium can be used with nitrogen or hydrogen.
  4. The same elution times could be obtained with nitrogen or hydrogen as with helium.
  5. The GC separation with nitrogen was reduced compared with helium and peak widths were increased by an average factor of 1.5 for similar elution times. Hydrogen provided ~0.7 narrower peak widths than helium.
  6. The signal with nitrogen was reduced compared with helium by an average factor of 3.3 and the signal loss was reduced with higher compounds mass. With hydrogen the signal loss was about a factor of 1.5 but the baseline noise was higher thus with similar S/N as with nitrogen.
  7. USEPA 8270 semivolatile mixture was easily analyzed with both nitrogen and hydrogen carrier gases.
  相似文献   

10.
Pharmaceuticals require careful and precise determination of their impurities that might harm the user upon consumption. Although today, the most common technique for impurities identification is liquid chromatography‐mass spectrometry (LC‐MS/MS), it has several downsides due to the nature of the ionization method. Also, the analyses in many cases are targeted thus despite being present, some of the compounds will not be revealed. In this paper, we propose and show a new method for untargeted analysis and identification of impurities in active pharmaceutical ingredients (APIs). The instrument used for these analyses is a novel electron ionization (EI) LC‐MS with supersonic molecular beams (SMB). The EI‐LC‐MS‐SMB was implemented for analyses of several drug samples spiked with an impurity. The instrument provides EI mass spectra with enhanced molecular ions, named Cold EI, which increases the identification probabilities when the compound is identified with the aid of an EI library like National Institute of Standards and Technology (NIST). We analyzed ibuprofen and its impurities, and both the API and the expected impurity were identified with names and structures by the NIST library. Moreover, other unexpected impurities were found and identified proving the ability of the EI‐LC‐MS‐SMB system for truly untargeted analysis. The results show a broad dynamic range of four orders of magnitude at the same run with a signal‐to‐noise ratio of over 10 000 for the API and almost uniform response.  相似文献   

11.
Photoionization mass spectrometry (PIMS) with vacuum ultraviolet (VUV) light source provides an efficient and fragmentation-free method for the soft ionization of gaseous compounds, in order to facilitate an understanding of thermal decomposition behavior and chemical composition of polymeric materials. The PIMS was applied to the evolved gas analysis (EGA) system equipped with a skimmer interface which is constituted based upon a jet separator principle between a vacuum MS chamber and an atmospheric sample chamber in a furnace. A photoionization source with a deuterium (D2) lamp was closely installed to the vacuum ionization chamber of a mass spectrometer to improve the ionization efficiency. The thermal decomposition of typical polymers in inert gas atmosphere was investigated by the EGA-PIMS and the resulting PI mass spectrum was characterized satisfactorily by only the parent ions with no contribution as a result of fragmentation during the ionization. The results suggested that the EGA-PIMS was an especially powerful and desirable in situ thermal analysis method for polymeric materials which evolve organic gases simultaneously and concurrently. The combination of EGA equipped with skimmer interface with no change of evolved gaseous species and PIMS with fragmentation-free during the ionization is described briefly, and the effective results are presented by comparing with EGA using conventional electron impact ionization mass spectrometry.  相似文献   

12.
The heavy petroleum fractions produced during refining processes need to be upgraded to useable products to increase their value. Hydrogenated heavy paraffinic fractions can be oxidised to produce high value products that contain a variety of oxygenates. These heavy oxygenated paraffinic fractions need to be characterised to enable the control of oxidation processes and to understand product properties. The accurate identification of the oxygenates present in these fractions by electron ionisation (EI) mass spectrometry is challenging due to the complexity of these heavy fractions. Adding to this challenge is the limited applicability of EI mass spectral libraries due to the absence of molecular ions from the EI mass spectra of many oxygenates. The separation of oxygenates from the complex hydrocarbon matrix prior to high temperature GC‐MS (HT‐GC‐MS) analysis reduces the complexity of these fractions and assists in the accurate identification of these oxygenates. Solid phase extraction (SPE) and supercritical fluid chromatography (SFC) were employed as prefractionation techniques. GC‐MS with supersonic molecular beams (SMBs) (also named GC‐MS with cold‐EI) utilises a SMB interface with which EI is done with vibrationally cold sample compounds in a fly‐through ion source (cold‐EI) resulting in a substantial increase in the molecular ion signal intensity in the mass spectrum. This greatly enhances the accurate identification of the oxygenates in these fractions. This study investigated the ionisation behaviour of oxygenated compounds using cold‐EI. The prefractionation by SPE and SFC and the subsequent analysis with GC‐MS with cold‐EI were applied to an oxygenated heavy paraffinic fraction.  相似文献   

13.
A cluster-based chemical ionization method has been developed that produces protonated molecular ions from molecules introduced through a supersonic molecular beam interface. Mixed clusters of the analyte and a clustering agent (water or methanol) are produced in the expansion region of the beam, and are subsequently ionized by “fly through” electron impact (EI) ionization, which results in a mass spectrum that is a combination of protonated molecular ion peaks together with the conventional EI fragmentation pattern. The technique is presented and discussed as a tool complementary to electron impact ionization in supersonic molecular beams. Surface-induced dissociation on a rhenium oxide surface is also applied to simplify the mass spectra of clusters and reveal the analyte spectrum. The high gas flow rates involved with the supersonic molecular beam interface that enable the easy introduction of the clustering agents also have been used to introduce deuterating agents. An easy-to-use, fast, and routine on-line deuterium exchange method was developed to exchange active hydrogens (NH, OH). This method, combined with electron impact ionization, is demonstrated and discussed in terms of the unique information available through the EI fragmentation patterns, its ability to help in isomer identification, and possible applications with fast gas chromatography-mass spectrometry in supersonic molecular beams.  相似文献   

14.
Comprehensive two‐dimensional gas chromatography (GC × GC) coupled to time‐of‐flight mass spectrometry is a powerful separation tool for complex petroleum product analysis. However, the most commonly used electron ionization (EI) technique often makes the identification of the majority of hydrocarbons impossible due to the exhaustive fragmentation and lack of molecular ion preservation, prompting the need of soft‐ionization energies. In this study, three different soft‐ionization techniques including photo ionization (PI), chemical ionization (CI), and field ionization (FI) were compared against EI to elucidate their relative capabilities to reveal different base oil hydrocarbon classes. Compared with EI (70 eV), PI (10.8 eV) retained significant molecular ion (M) information for a large number of isomeric species including branched‐alkanes and saturated monocyclic hydrocarbons along with unique fragmentation patterns. However, for bicyclic/polycyclic naphthenic and aromatic compounds, EI played upper hand by retaining molecular as well as fragment ions to identify the species, whereas PI exhibited mainly molecular ion signals. On the other hand, CI revealed selectivity towards different base oil groups, particularly for steranes, sulfur‐containing thiophenes, and esters, yielding protonated molecular ions (M + H)+ for unsaturated and hydride abstracted ions (M‐H+) for saturated hydrocarbons. FI, as expected, generated intact molecular ions (M) irrespective to the base oil chemical classes. It allowed elemental composition by TOFMS with a mass resolving power up to 8000 (FWHM) and a mass accuracy of 1 mDa, leading to the calculation of heteroatomic content, double bond equivalency, and carbon number of the compounds. The qualitative and quantitative results presented herein offer a unique perspective into the detailed comparison of different ionization techniques corresponding to several hydrocarbon classes.  相似文献   

15.
Orthogonal acceleration time‐of‐flight (oa‐TOF) mass spectrometry (MS) was coupled to gas chromatography (GC) to measure ion yields (ratio of ion counts to number of neutrals entering the ion source) and signal‐to‐noise (S/N) in the electron ionization (EI) mode (hard ionization) as well as in the soft ionization modes of chemical ionization (CI), electron capture negative ion chemical ionization (NICI) and field ionization (FI). Mass accuracies of the EI and FI modes were also investigated. Sixteen structurally diverse volatile organic compounds were chosen for this study. The oa‐TOF mass analyzer is highly suited for FI MS and provided an opportunity to compare the sensitivity of this ionization method to the more conventional ionization methods. Compared to the widely used quadrupole mass filter, the oa‐TOF platform offers significantly greater mass accuracy and therefore the possibility of determining the empirical formula of analytes. The findings of this study showed that, for the instrument used, EI generated the most ions with the exception of compounds able to form negative ions readily. Lower ion yields in the FI mode were generally observed but the chromatograms displayed greater S/N and in many cases gave spectra dominated by a molecular ion. Ion counts in CI are limited by the very small apertures required to maintain sufficiently high pressures in the ionization chamber. Mass accuracy for molecular and fragment ions was attainable at close to manufacturer's specifications, thus providing useful information on molecular ions and neutral losses. The data presented also suggests a potentially useful instrumental combination would result if EI and FI spectra could be collected simultaneously or in alternate scans during GC/MS. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
Although the coupling of GC/MS with atmospheric pressure ionization (API) has been reported in 1970s, the interest in coupling GC with atmospheric pressure ion source was expanded in the last decade. The demand of a “soft” ion source for preserving highly diagnostic molecular ion is desirable, as compared to the “hard” ionization technique such as electron ionization (EI) in traditional GC/MS, which fragments the molecule in an extensive way. These API sources include atmospheric pressure chemical ionization (APCI), atmospheric pressure photoionization (APPI), atmospheric pressure laser ionization (APLI), electrospray ionization (ESI) and low temperature plasma (LTP). This review discusses the advantages and drawbacks of this analytical platform. After an introduction in atmospheric pressure ionization the review gives an overview about the history and explains the mechanisms of various atmospheric pressure ionization techniques used in combination with GC such as APCI, APPI, APLI, ESI and LTP. Also new developments made in ion source geometry, ion source miniaturization and multipurpose ion source constructions are discussed and a comparison between GC-FID, GC-EI-MS and GC-API-MS shows the advantages and drawbacks of these techniques. The review ends with an overview of applications realized with GC-API-MS.  相似文献   

17.
We have developed a combined EI/FI source for gas chromatography/orthogonal acceleration time‐of‐flight mass spectrometry (GC/oaTOFMS). In general, EI (electron ionization) and FI (field ionization) mass spectra are complementary: the EI mass spectrum contains information about fragment ions, while the FI mass spectrum contains information about molecular ions. Thus, the comparative study of EI and FI mass spectra is useful for GC/MS analyses. Unlike the conventional ion sources for FI and EI measurements, the newly developed source can be used for both measurements without breaking the ion source vacuum or changing the ion source. Therefore, the combined EI/FI source is more preferable than the conventional EI or FI ion source from the viewpoint of the reliability of measurements and facility of operation. Using the combined EI/FI source, the complementarity between EI and FI mass spectra is demonstrated experimentally with n‐hexadecane (100 pg): characteristic fragment ions for the n‐alkane such as m/z 43, 57, 71, and 85 are obtained in the EI mass spectrum, while only the parent peak of m/z 226 (M+) without any fragment ions is observed in the FI mass spectrum. Moreover, the field desorption (FD) measurement is also demonstrated with poly(ethylene glycol)s M600 (10 ng) and M1000 (15 ng). Signals of [M+H]+, [M+Na]+ and [M+K]+ are clearly detected in the FD mass spectra. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

18.
This study covers a new method and related instrumentation for whole blood analysis for medical diagnostics. Two-μL whole blood samples were collected using “minimal invasive” diabetes lancet and placed on a thin glass rod mounted on a newly designed BloodProbe. The BloodProbe with the whole blood sample was inserted directly into a ChromatoProbe mounted on the GC inlet, and thus, no sample preparation was involved. The analysis was performed within 10 min using a GC-MS with Cold EI that is based on interfacing GC and MS with supersonic molecular beams (SMB) along with electron ionization of vibrationally cold sample compounds in the SMB (hence the name Cold EI). Our blood analysis revealed several observations: (1) Detailed mass chromatograms were generated with full range of all the nonpolar lipids in blood including fatty acids, cholesterol, cholesteryl esters, vitamin E, monoglycerides, diglycerides, and triglycerides. (2) The analysis of whole blood was found to be as informative as the conventional clinical analysis of blood serum. (3) Cholesteryl esters were more sensitive than free cholesterol alone to the effect of diet of obese people. (4) Major enhancement of several fatty acid methyl esters was found in the blood of a cancer patient with liver dysfunction. (5) Vitamin E as both α- and β-tocopherol was found with person-dependent ratio of these two compounds. (6) Elemental sulfur S8 was identified in blood. (7) Several drugs and other compounds were found and need further study of their correlation to medical issues.  相似文献   

19.
Upon the supersonic expansion of helium mixed with vapor from an organic solvent (e.g. methanol), various clusters of the solvent with the sample molecules can be formed. As a result of 70 eV electron ionization of these clusters, cluster chemical ionization (cluster CI) mass spectra are obtained. These spectra are characterized by the combination of EI mass spectra of vibrationally cold molecules in the supersonic molecular beam (cold EI) with CI-like appearance of abundant protonated molecules, together with satellite peaks corresponding to protonated or non-protonated clusters of sample compounds with 1-3 solvent molecules. Like CI, cluster CI preferably occurs for polar compounds with high proton affinity. However, in contrast to conventional CI, for non-polar compounds or those with reduced proton affinity the cluster CI mass spectrum converges to that of cold EI. The appearance of a protonated molecule and its solvent cluster peaks, plus the lack of protonation and cluster satellites for prominent EI fragments, enable the unambiguous identification of the molecular ion. In turn, the insertion of the proper molecular ion into the NIST library search of the cold EI mass spectra eliminates those candidates with incorrect molecular mass and thus significantly increases the confidence level in sample identification. Furthermore, molecular mass identification is of prime importance for the analysis of unknown compounds that are absent in the library. Examples are given with emphasis on the cluster CI analysis of carbamate pesticides, high explosives and unknown samples, to demonstrate the usefulness of Supersonic GC/MS (GC/MS with supersonic molecular beam) in the analysis of these thermally labile compounds. Cluster CI is shown to be a practical ionization method, due to its ease-of-use and fast instrumental conversion between EI and cluster CI, which involves the opening of only one valve located at the make-up gas path. The ease-of-use of cluster CI is analogous to that of liquid CI in ion traps with internal ionization, and is in marked contrast to that of CI with most other standard GC/MS systems that require a change of the ion source.  相似文献   

20.
在超声射流冷却条件下用VUV同步辐射研究了CH3I分子的光电离过程。测定了CH3I光电离及解离电离产生的CH3I^+, CH3^+和I^+的出现势, 结合已确认的热力学数据, 估算出体系中有关离子的标准生成焓、分子和分子离子的键能、自由基的质子亲合势及母体离子的解离能等数据。对CH3I分子VUV光解离电离通道进行了分析。  相似文献   