首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 718 毫秒
1.
Capillary electrophoresis can be a valuable tool for the on-line monitoring of bioprocesses. The enzymatic conversion of nucleotide adenosine triphosphate (ATP) to adenosine diphosphate (ADP) by hexokinase (HK) was monitored in the bioreactor interfaced by a laboratory-built microsampler to a capillary electrophoresis unit. The use of this specially designed sampling device enabled rapid consecutive injections to be performed without high-voltage (HV) interruptions. No additional sample preparation was required. The method of micellar electrokinetic chromatography, employing reversed electroosmotic flow (EOF) by cationic surfactant and reversed polarity mode provided a good resolution and short analysis time of less than 5 min. The samples were injected electrokinetically, using -25 kV voltage for 3 s and detected by their UV absorbance at 254 nm. The analytes were detected at a microg/ml level with a reproducibility of about 7%. To demonstrate the potential of CE in understanding the processes of biological interest, such as nucleotide degradation and metabolism, the investigation of the efficiency and the time course of the enzymatic transformation was carried out.  相似文献   

2.
Recent investigations have shown that capillary electrophoresis (CE) can be an alternative to other techniques such as polyacrylamide gel electrophoresis (PAGE) or sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) in the qualitative analysis and separation of the different casein fractions in cow's and ewe's milk. However, past work has not yet clarified whether that method can achieve good quantifications. The present study has used a commercial whole ovine casein standard and a mixture of the standard and whole casein extracted from ewe's milk cheese to test the reliability of the technique. The results show that CE was able to quantify the ewe's milk caseins. The areas under four of the most representative peaks on the electrophoretogram for two alpha and two beta-caseins (designated alpha-casein1CE, alpha-casein2CE, beta-casein1CE, and beta-casein2CE in order of elution) were used to validate the method. In relation to linearity, coefficient of determination (r2) values greater than 99% were obtained for the regressions of each of the caseins. Moreover, each casein yielded response factors with a relative standard deviation (R.S.D.) of less than or equal to 5. The coefficients obtained in the day-to-day reproducibility analysis were higher than those for the same-day repeatability, but all the values were within acceptable limits. In the study of accuracy, the percentage recovery rates for the alpha-casein fractions were higher than those for the beta-casein fractions, hence quantification of the latter using this technique would appear to be more accurate under the conditions employed.  相似文献   

3.
The objective of this study was to monitor the release of short-chain free fatty acids (FFA) from milk fat during hydrolysis with lipase using capillary electrophoresis. Sample and run buffer allowed FFA to be maintained in solution by using cyclodextrin and methanol. Indirect UV detection at 270 nm was used, employing p-anisate as a chromophore. Calibration curves constructed for each individual FFA followed linear relationships with highly significant (p < 0.01) correlation coefficients. Electrophoretic FFA profiles of fresh milk fat and lipolyzed milk fat showed marked qualitative and quantitative differences. Butanoic acid (C4) was found in a concentration of 64 ppm, while hexanoic (C6) and octanoic (C8) acids were found in concentrations of 3.8 ppm in fresh milk fat. After a 60-min hydrolysis with commercial lipase, FFA released from milk fat consisted mainly of high concentrations (ppm) of butanoic (C4) (900), followed by hexanoic (C6) (427), octanoic (C8) (282), decanoic (C10) (92), pentanoic (C5) (47), and dodecanoic (C12) (37.5) acids. Ratios of FFA that were associated with flavor balance were calculated. The application of CE for lipolysis monitoring in milk fat offers a simple and fast method for the determination of FFA. Quantitative data can be obtained in 20 min, including sample preparation. The lengthy and laborious steps required in traditional chromatographic techniques, such as lipid extraction, FFA isolation, and derivatization, were not required in this CE method. The implementation of CE for milk fat lipolysis monitoring may be a useful quality control tool for dairy flavor development and production.  相似文献   

4.
The discovery of biomarkers is currently attracting much interest as it harbors great potential for the diagnosis and monitoring of human diseases. Here we have used two advanced mass spectroscopy based technologies, surface enhanced laser desorption ionization (SELDI-MS) and capillary electrophoresis/mass spectrometry (CE/MS), to obtain proteomic patterns of urine samples from patients suffering from membranous glomerulonephritis (MGN) and healthy volunteers. The results indicate that CE/MS analysis is able to display a rich and complex pattern of polypeptides with high resolution and high mass accuracy. In order to analyze these patterns, the MosaiqueVisu software was developed for peak identification, deconvolution and the display of refined maps in a three-dimensional format. The polypeptide profiles obtained with SELDI-MS from the same samples are much sparser and show lower resolution and mass accuracy. The SELDI-MS profiles are further heavily dependent on analyte concentration. SELDI-MS analysis identified three differentially expressed polypeptides, which are potential biomarkers that can distinguish healthy donors from patients with MGN. In contrast, approximately 200 potential biomarkers could be identified by CE/MS. Thus, while SELDI-MS is easy to use and requires very little sample, CE/MS generates much richer data sets that enable an in-depth analysis.  相似文献   

5.
Chiral resolution of native DL-tartaric acid was achieved by ion-pair capillary electrophoresis (CE) using an aqueous-ethanol background electrolyte with (1R,2R)-(-)-1,2-diaminocyclohexane (R-DACH) as a chiral counterion. Factors affecting chiral resolution and migration time of tartaric acid were studied. By increasing the viscosity of the background electrolyte and the ion-pair formation, using organic solvents with a lower relative dielectric constant, resulted in a longer migration time. The optimum conditions for both high resolution and short migration time of tartaric acid were found to be a mixture of 65% v/v ethanol and 35% v/v aqueous solution containing 30 mM R-DACH and 75 mM phosphoric acid (pH 5.1) with an applied voltage of -30 kV at 25 degrees C, using direct detection at 200 nm. By using this system, the resolution (Rs) of racemic tartaric acid was approximately 1. The electrophoretic patterns of tartaric and malic acids suggest that two carboxyl groups and two hydroxyl groups of tartaric acid are associated with the enantioseparation of tartaric acid by the proposed CE method.  相似文献   

6.
Flow analysis is the science of performing quantitative analytical chemistry in flowing streams. Because of its efficiency and speed of analysis, capillary electrophoresis (CE) is a prospective method for the monitoring of a flow composition withdrawn from various processes (e.g., occurring in bioreactors, fermentations, enzymatic assays, and microdialysis samples). However, interfacing CE to a various flow of interest requires further study. In this paper, several ingenious approaches on interfacing flow from various chemical or bioprocesses to a capillary electrophoresis instrument are reviewed. Most of these interfaces can be described as computer-controlled autosamplers. Even though most of the described interfaces waste too many samples, many interesting and important applications of the devices are reported. However, the lack of commercially available devices prevents the wide application of CE for flow analysis. On the contrary, this fact opens up a potential avenue for future research in the field of flow sampling by CE.  相似文献   

7.
This study develops a novel capillary electrophoresis (CE) microfluidic device featuring a conventional cross-form injection system and an expansion chamber located at the inlet of the separation channel. The combined injection system/expansion chamber arrangement is designed to deliver a high-quality sample band into the separation channel such that the detection performance of the device is enhanced. Numerical simulations are performed to investigate the electrokinetic transport processes in the microfluidic device and to establish the optimal configuration of the expansion chamber. The results indicate that an expansion chamber with an expansion ratio of 2.5 and an expansion length of 500 microm delivers a sample plug with the correct shape and orientation. With this particular configuration, the peak intensities of the sample are sharp and clearly distinguishable in the detection region of the separation channel. Therefore, this configuration is well suited for capillary electrophoresis applications which require a highly sensitive resolution of the sample plug. The novel CE microfluidic device developed in this study has an exciting potential for use in high-performance, high-throughput chemical analysis applications and in many other applications throughout the field of micro-total-analysis-systems.  相似文献   

8.
A hollow fiber sampling inlet end of capillary electrophoresis (CE) for small ions in complex samples is described. A short piece of hollow fiber, which only permits small ions to pass through its wall, was directly connected to one end of a capillary. Small ions in complex samples were injected into the capillary through the hollow fiber by an electrokinetic method. The experimental results of CE for standard anion mixture solutions, river water, and milk samples show that the hollow fiber sampling inlet end is a simple and useful method for the CE of complex samples. Furthermore, it has been shown that the method can be used to study small anion changes during the milk storing process.  相似文献   

9.
When optimizing a capillary electrophoresis/electrospray ionization mass spectrometry (CE/ESI-MS) system, consideration has to be given not only to the separation but also to the electrospray stability. Methods developed for CE/UV analysis of drugs and peptides were considered and modified to be suitable for a CE/MS system with a robust sheathless interface. Different concentrations of the organic modifiers acetonitrile, methanol and 2-propanol were used in the separation buffer. The type and concentrations of these modifiers were also compared with reference to electrospray stability, sensitivity and time of analysis. In addition, different ionic strengths in the buffers were evaluated with reference to electrospray stability. The repeatability was used for the estimation of electrospray stability. The degree to which these parameters influenced the separation and the ESI stability was studied using a nine-peptide standard mixture and the antibiotic drugs bacampicillin and ampicillin as test substances. The analysis time and resolution were used as measures of the efficiency of the separation. A time-of-flight MS analyzer was used since it has the potential advantages of becoming a better fit for integration of CE with MS owing to the speed and sensitivity of this mass analyzer. The detection limit, i.e. 1 microM, for bacampicillin was comparable to what could be achieved with CE/MS on a quadrupole instrument using selected ion monitoring and sheath flow ESI.  相似文献   

10.
A sheathless and electrodeless nanospray interface has been used to interface a polycarbonate capillary electrophoresis (CE) chip to a mass spectrometer (MS). The chip was made of two flat polycarbonate plates which were bolted together. Channels were imprinted in one of the plates with metal wires, using a hydraulic press. A short tapered capillary connected to the chip was used as the nanospray emitter. The advantage of this electrodeless interface is that it was not necessary to apply a electrospray voltage to the chip or the nanospray emitter. Instead, the CE voltage already applied to the buffer compartment on the chip, to drive the electrophoresis, was used to generate the spray also. A low conductivity buffer of 1.25 mmol/L ammonium acetate in 80% methanol was used to obtain a large electric field across the buffer channel. The performance of the device was evaluated by analyzing a mixture of three beta-agonists Relative standard deviation (RSD) values obtained were between 4.8 and 5.0%. A sample concentration of 40 nmol/L resulted in a signal-to-noise ratio of 2 to 5 for the different components. Compared to a conventional CE analysis in a fused silica capillary with UV detection, only a minor loss of resolution was observed, which can be attributed to the design of the chip.  相似文献   

11.
An in-capillary electrode sheathless interface was applied to the capillary electrophoresis/electrospray ionization-mass spectrometry (CE/ESI-MS) analysis of mixtures of small peptides, proteins, and tryptic digests of proteins. The effects of different experimental parameters on the performance of this CE/ESI-MS interface were studied. The distance of the in-capillary electrode from the CE outlet and the length of the electrode inside the capillary had no significant effects on the CE separation and ESI behavior under the experimental conditions used. However, significant enhancement of the sensitivity resulted from the use of narrower CE capillaries. Using a quadrupole mass spectrometer, an aminopropylsilane-coated capillary, and a wide scan mass-to-charge ratio range of 500–1400, detection limits of approximately 4, 1, and 0.6 fmol for cytochrome c and myoglobin were achieved for 75-, 50-, and 30-µm inner diameter capillaries, respectively. Approximately one order of magnitude lower detection limits were achieved under the multiple-ion monitoring mode. The application of the in-capillary electrode sheathless interface to real-world samples was demonstrated by CE/ESI-MS analysis of a human blood sample.  相似文献   

12.
Végvári A  Hjertén S 《Electrophoresis》2003,24(21):3815-3820
Recently we described the design of a hybrid microdevice for micro(nano)electrophoresis and electrochromatography, discussed its advantages and disadvantages compared to conventional microdevices and presented a few applications with low-molecular-weight samples. In this paper, we demonstrate the broad application range of this device using UV-based analyses of (i) peptides by free-zone electrophoresis and electrophoresis in a recently introduced gel (polyacrylamide cross-linked with allyl-beta-cyclodextrin), (ii) proteins by electrophoretic molecular-sieving in a polymer solution supplemented with SDS, (iii) DNA fragments by electrophoresis in the above gel, (iv) virus particles in this gel, as well as in free buffer and (v) bacteria in free buffer. To illustrate the advantages of the hybrid microdevice we can mention that electrophoresis of proteins in a polymer-containing buffer, supplemented with sodium dodecyl sulfate (SDS), in a 4.30 (2.75) cm long channel gave a resolution similar to that in conventional capillary electrophoresis in a 23.5 (18.6) cm long capillary and analysis times which were 15-fold shorter.  相似文献   

13.
Sixteen synthetic chemical drugs, often found in adulterated Chinese medicines, were studied by capillary electrophoresis/UV absorbance (CE/UV) and capillary electrophoresis/electrospray ionization mass spectrometry (CE/ESI-MS). Only nine peaks were detected with CZE/UV, but on-line CZE/MS provided clear identification for most compounds. For a real sample of a Chinese medicinal preparation, a few adulterants were identified by their migration times and protonated molecular ions. For coeluting compounds, more reliable identification was achieved by MS/MS in selected reaction monitoring mode. Micellar electrokinetic chromatography (MEKC) using sodium dodecyl sulfate (SDS) provided better separation than capillary zone electrophoresis (CZE), and, under optimal conditions, fourteen peaks were detected using UV detection. In ESI, the interference of SDS was less severe in positive ion mode than in negative ion mode. Up to 20 mM SDS could be used in direct coupling of MEKC with ESI-MS if the mass spectrometer was operated in positive ion mode. Because of better resolution in MEKC, adulterants can be identified without the use of MS/MS.  相似文献   

14.
Bacterial counts provide important information during the processes such as pathogen detection and hygiene inspection and these processes are critical for public health and food/pharmaceutical production. In this study, we demonstrate the quantification of the number of bacterial cells based on the autofluorescence from the cell lysate on a microfluidic chip. We tested three model pathogenic bacteria (Listeria monocytogenes F4244, Salmonella Enteritidis PT1 and Escherichia coli O157:H7 EDL 933). In the experiment, a plug of approximately 150 pL containing lysate from 240 to 4100 cells was injected into a microfluidic channel with downstream laser-induced fluorescence detection under electrophoresis conditions. We found that the autofluorescence intensity increased with the number of cells almost linearly for all three bacteria. The autofluorescence remained a single peak when the cell lysate contained a mixture of different bacterial species. We also demonstrate a simple microfluidic device that integrates entrapment and electrical lysis of bacterial cells with fluorescence detection. Such a device can carry out the quantification of bacterial cells based on lysate autofluorescence without off-chip procedures. This study offers a simple and fast solution to on-chip quantification of bacterial cells without labeling. We believe that the method can be extended to other bacterial species.  相似文献   

15.
Popa TV  Mant CT  Hodges RS 《Electrophoresis》2004,25(9):1219-1229
The present study compares a charge/hydrophobicity capillary electrophoresis (CE) approach to reversed-phase high-performance liquid chromatography (RP-HPLC) for the separation of three series of four synthetic, random coil peptide standards. Each series has peptides of the same positive charge (+1, +2 and +3 series) and length but differing in hydrophobicity. Complete resolution of the 12 peptides was achieved via a novel CE approach: a capillary zone electrophoresis (CZE) mode effected a separation of identically charged peptides; within each charged group of peptides, the addition of perfluorinated acid anionic ion-pairing reagents allowed resolution of the peptides through a mechanism based on peptide hydrophobicity which we have termed ioninteraction (II)-CZE. The peak capacity and peptide resolution of this CE approach was superior to that of RP-HPLC and stresses an important role for CE for peptide/proteomic applications.  相似文献   

16.
Compounds 1-4 are the four stereoisomers of a synthetic new potential antiviral agent (d4T analog) containing two chiral centers and a base (uracil). Both high-performance liquid chromatography (HPLC) and capillary electrophoresis (CE) techniques were used to separate and quantify enantiomers with high resolution. The determination of enantiomeric purity of the compounds was developed using both amylose chiral stationary phase by HPLC and anionic cyclodextrins (highly S-CD) as chiral selectors in CE. The HPLC method was found to be superior in sensitivity to the CE method.  相似文献   

17.
A microfabricated device capable of selecting and collecting multiple components from a mixture separated by capillary electrophoresis (CE) is described. This collection is automated and can be easily controlled by a set of rules defined by an operator, enabling fast and consistent operation. The device consists of an electrokinetically steered fluidic network that can be divided into three sections: a CE part, a fractions distribution region and a set of storage channels. Sample fractions leave the CE channel and are detected in the interfacial region by fluorescence intensity measurements. If an upcoming peak is detected, separation is withheld and the potentials are reconfigured to force the fraction into one of the collection channels, where they become available for further processing or analysis. The sequence of separation and collection is repeated until all the bands of interest are captured. A mixture of three fluorescent dyes (Rhodamine 6G, Rhodamine B and Fluorescein) was used to demonstrate the principle. The components were repeatedly separated by means of CE and pooled in their respective storage channels. In comparison to previous developments, the system presented in this paper offers automatic collection of all fractions in a single run. Furthermore, it is possible to run the system in a repetitive mode for accumulative pooling if more fractionated sample is required.  相似文献   

18.
The performance of two capillary electrophoresis (CE) instruments, one commercial and one homemade device, were compared for the determination of derivatised aminated compounds with fluorescein isothiocyanate (FITC). The commercial CE system first uses an argon ion laser as excitation source; the homemade CE device uses an inexpensive blue-light-emitting diode (LED) as the light source and a charge-coupled device (CCD) as the detection system. After fine optimisation of several separation parameters in both devices, a co-electroosmotic flow CE methodology was achieved in coated capillary tubing with 0.001% hexadimetrine bromide (HDB), and 50 mmol L−1 sodium borate at pH 9.3 with 20% 2-propanol for the determination of several amines and aminoacids. Analytical performances, applicability in beer samples and other aspects such as cost or potential for miniaturization have been compared for both devices.  相似文献   

19.
毛红霞  黎源倩  裴晓方  何超  渠凌丽 《色谱》2007,25(4):473-477
建立了食品中常见致病菌大肠杆菌O157:H7的uidA基因、沙门菌的invA基因和志贺菌的ipaH基因的多重聚合酶链反应(PCR)产物的毛细管电泳快速检测方法。根据这3种致病菌的特异性基因序列设计多重PCR引物,优化PCR扩增反应体系,采用7.0 g/L 甲基纤维素为筛分介质,毛细管电泳-激光诱导荧光检测法同时检测了3种常见致病菌的PCR扩增产物。在优化的多重PCR反应和毛细管筛分电泳条件下,该方法可以同时检测沙门菌、志贺菌和大肠杆菌O157:H7基因的多重PCR扩增产物,22 min内即可完成3种常见致病菌的毛细管电泳检测。迁移时间的相对标准偏差为1.47%~2.07%。与凝胶电泳法比较,该法简便快速,灵敏度高,可用于多种致病菌脱氧核糖核酸的检测,为食品安全提供了一种可靠的快速检测方法。  相似文献   

20.
The complex dendrimeric contrast agent Gadomer has been comprehensively characterized using various mass spectrometric techniques in combination with capillary electrophoresis. The analytical challenges arising from the structure of this analyte, e.g., the presence of a complex isotopic pattern originating from multiple gadolinium chelates could be overcome using this combined approach. Results obtained from initial MALDI-TOF-MS measurements could subsequently be complemented and confirmed by CE-ESI-TOF-MS measurements. Furthermore, high resolution Fourier transform-ion cyclotron resonance-MS (FT-ICR-MS) as a stand alone technique and in combination with CE was performed to obtain mass spectra of high mass accuracy and resolution of various impurities and related dendrimers present in low concentrations in several Gadomer batches. The profile of related dendrimers and impurities of lower molecular weight present in Gadomer could be elucidated and variances in the pattern of related dendrimers present in batches obtained via different synthetic routes could be detected. The qualitative analysis of Gadomer using MS techniques in combination with CE provides the fundamental basis for a framework of analytical methodologies for the characterization of Gadomer. By designing such a framework of methodologies the challenges associated with the introduction of dendrimers into the clinical stage may be overcome and the reproducible quality and safety of these innovative products can be ensured.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号