首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   43篇
  免费   1篇
化学   38篇
数学   2篇
物理学   4篇
  2020年   1篇
  2014年   1篇
  2010年   2篇
  2009年   1篇
  2008年   2篇
  2007年   3篇
  2006年   5篇
  2005年   3篇
  2004年   5篇
  2003年   5篇
  2002年   4篇
  2000年   1篇
  1999年   3篇
  1994年   1篇
  1992年   1篇
  1991年   2篇
  1988年   1篇
  1987年   3篇
排序方式: 共有44条查询结果,搜索用时 15 毫秒
1.
We have developed further a chromatographic model for studying the hydrophobic interactions which characterize the way a ligand binds to its receptor. This model is based on observing the retention behaviour of de novo designed model 18-residue amphipathic alpha-helical peptides (representing the hydrophobic binding domain of a ligand) on reversed-phase packings by varying hydrophobicity (representing a receptor protein with a hydrophobic binding pocket). Mutants of the "native" peptide ligand (which contains seven Leu residues in its non-polar face) were designed by replacing one residue in the center of the extremely non-polar face of the amphipathic alpha-helix. Through reversed-phase liquid chromatography of these peptides at pH 2.0 on cyano and C18 columns, we have demonstrated how an increase in receptor hydrophobicity (represented by an increase in column stationary phase hydrophobicity; cyano --> C18) significantly enhances hydrophilicity of polar amino acid side-chains at the ligand-receptor interface while moderately enhancing the hydrophobicity of non-polar side-chains. The addition of salt (100 mM sodium perchlorate) to the aqueous environment surrounding the binding site of receptor and ligand was also shown to have a profound effect on side-chain hydrophilicity/hydrophobicity in the binding interface. This effect was particularly dramatic for the positively charged side-chains Arg, Lys and His, whose significant enhancement of hydrophobicity in the presence of the cyano column contrasted with their increase in hydrophilicity in the presence of the considerably more hydrophobic C18 stationary phase. Our results have major implications to understanding the influence of hydrophobic and aqueous environment on hydrophilicity/hydrophobicity of amino acid side-chains and the role side-chains play in the folding and stability of proteins.  相似文献   
2.
Mixed-mode hydrophilic interaction/cation-exchange chromatography (HILIC/CEX) is a novel high-performance technique which has excellent potential for peptide separations. Separations by HILIX/CEX are carried out by subjecting peptides to linear increasing salt gradients in the presence of high levels of acetonitrile, which promotes hydrophilic interactions overlaid on ionic interactions with the cation-exchange matrix. In the present study, HILIC/CEX has been compared to reversed-phase liquid chromatography (RP-HPLC) for separation of mixtures of diastereomeric amphipathic alpha-helical peptide analogues, where L- and D-amino acid substitutions were made in the centre of the hydrophilic face of the amphipathic alpha-helix. Unlike RP-HPLC, temperature had a substantial effect on HILIC/CEX of the peptides, with a rise in temperature from 25 to 65 degrees C increasing the retention times of the peptides as well as improving resolution. Our results again highlight the potential of HILIC/CEX as a peptide separation mode in its own right as well as an excellent complement to RP-HPLC.  相似文献   
3.
In order to characterize the effect of temperature on the retention behaviour and selectivity of separation of polypeptides and proteins in reversed-phase high-performance liquid chromatography (RP-HPLC), the chromatographic properties of four series of peptides, with different peptide conformations, have been studied as a function of temperature (5-80 degrees C). The secondary structure of model peptides was based on either the amphipathic alpha-helical peptide sequence Ac-EAEKAAKEX(D/L)EKAAKEAEK-amide, (position X being in the centre of the hydrophobic face of the alpha-helix), or the random coil peptide sequence Ac-X(D/L)LGAKGAGVG-amide, where position X is substituted by the 19 L- or D-amino acids and glycine. We have shown that the helical peptide analogues exhibited a greater effect of varying temperature on elution behaviour compared to the random coil peptide analogues, due to the unfolding of alpha-helical structure with the increase of temperature during RP-HPLC. In addition, temperature generally produced different effects on the separations of peptides with different L- or D-amino acid substitutions within the groups of helical or non-helical peptides. The results demonstrate that variations in temperature can be used to effect significant changes in selectivity among the peptide analogues despite their very high degree of sequence homology. Our results also suggest that a temperature-based approach to RP-HPLC can be used to distinguish varying amino acid substitutions at the same site of the peptide sequence. We believe that the peptide mixtures presented here provide a good model for studying temperature effects on selectivity due to conformational differences of peptides, both for the rational development of peptide separation optimization protocols and a probe to distinguish between peptide conformations.  相似文献   
4.
Despite the continuing dominance of trifluoroacetic acid (TFA) as the anionic ion-pairing reagent of choice for peptide separations by reversed-phase high-performance liquid chromatography (RP-HPLC), we believe that a step-by-step approach to re-examining the relative efficacy of TFA compared to other ion-pairing reagents is worthwhile, particularly for the design of separation protocols for complex peptide mixtures, e.g., in proteomics applications. Thus, we applied RP-HPLC in the presence of different concentrations of anionic ion-pairing reagents - phosphoric acid, TFA, pentafluoropropionic acid (PFPA) and heptafluorobutyric acid (HFBA)--to a mixture of three groups of four 10-residue peptides, these groups containing peptides of +1, +3 or +5 net charge. Overall separation of the 12-peptide mixture improved with increasing reagent hydrophobicity (phosphate- < TFA- < PFPA- < HFBA-) and/or concentration of the anion, with reagent hydrophobicity having a considerably more pronounced effect than reagent concentration. HFBA, in particular, achieved an excellent separation at a concentration of just 10 mM, whereby the peptides were separated by charged groups (+1 < +3 < +5) and hydrophobicity within these groups. There was an essentially equal effect of reagent hydrophobicity and concentration on each positive charge of the peptides, a useful observation for prediction of the effect of varying counterion concentration hydrophobicity and/or concentration during optimization of peptide purification protocols. Peak widths were greater for the more highly charged peptides, although these could be decreased significantly by raising the acid concentration; concomitantly, peptide resolution increased with increasing concentration of ion-pairing reagent.  相似文献   
5.
The present study uses an unique capillary electrophoresis (CE) approach, that we have termed ion-interaction capillary zone electrophoresis (II-CZE), for the separation of diastereomeric peptide pairs where a single site in the centre of the non-polar face of an 18-residue amphipathic alpha-helical peptide is substituted by the 19 L- or D-amino acids. Through the addition of perfluorinated acids at very high concentrations (up to 400 mM), such concentration levels not having been used previously in chromatography or CE, to the background electrolyte (pH 2.0), we have been able to achieve baseline resolution of all 19 diastereomeric peptide pairs with an uncoated capillary. Since each diastereomeric peptide pair has the same sequence, identical mass-to-charge ratio and identical intrinsic hydrophobicity, such a separation by CZE has previously been considered theoretically impossible. Excellent resolution was achieved due to maximum advantage being taken of even subtle disruption of peptide structure/conformation (due to the presence of D-amino acids) of the non-polar face of the amphipathic alpha-helix and its interaction with the hydrophobic anionic ion-pairing reagents. In addition, due to the excellent resolution of diastereomeric peptide pairs by this novel CZE approach, we have also been able to separate a mixture of these closely-related alpha-helical peptides.  相似文献   
6.
Popa TV  Mant CT  Hodges RS 《Electrophoresis》2004,25(9):1219-1229
The present study compares a charge/hydrophobicity capillary electrophoresis (CE) approach to reversed-phase high-performance liquid chromatography (RP-HPLC) for the separation of three series of four synthetic, random coil peptide standards. Each series has peptides of the same positive charge (+1, +2 and +3 series) and length but differing in hydrophobicity. Complete resolution of the 12 peptides was achieved via a novel CE approach: a capillary zone electrophoresis (CZE) mode effected a separation of identically charged peptides; within each charged group of peptides, the addition of perfluorinated acid anionic ion-pairing reagents allowed resolution of the peptides through a mechanism based on peptide hydrophobicity which we have termed ioninteraction (II)-CZE. The peak capacity and peptide resolution of this CE approach was superior to that of RP-HPLC and stresses an important role for CE for peptide/proteomic applications.  相似文献   
7.
An α‐helical model peptide (Ac‐EAEKAAKE‐X‐EKAAKEAEK‐amide) was used as a template to examine the efficacy of conventional reversed‐phase high‐performance liquid chromatography (RP‐HPLC) in separating peptide analogs with single substitutions (at position X) of diasteromeric amino acids Ile, allo‐Ile, d ‐Ile and d ‐allo‐Ile. We compared differences in peptide retention behavior on a C8 column and a C18 column at different temperatures. We demonstrated how subtle differences in peptide secondary structure affected by the different substitutions of amino acids with identical overall hydrophobicity enabled effective resolution of these peptide analogs. We also demonstrated the ability of RP‐HPLC to separate Ile‐ and allo‐Ile‐substituted analogs of a 26‐residue α‐helical antimicrobial peptide (AMP), with the substitution site towards the C‐terminus of the α‐helix. These peptides show different values of antibacterial activity and hemolytic activity, and different selectivity against bacteria and human cells. Our results underline the ability of RP‐HPLC to resolve even difficult diasteromeric peptide mixtures as well as its value in monitoring very subtle hydrophobicity changes in de novo‐designed AMP. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   
8.
Summary We have examined the effect of particle size of silica-based reversed-phase packings and column packing techniques on the reversed-phase analytical separation of a peptide mixture. A C18 packing of 15–20 μm average particle size produced satisfactory peptide resolution, allowing a relatively inexpensive scale up to the preparative purification of peptides. A shallow gradient (0.1% acetonitrile/min) elution procedure was developed for the preparative purification of closely related decapeptides (differing by one methyl group) on analytical (250×4.1 mm I.D.) and semipreparative (250×10 mm I.D.) columns. Up to 30 mg and 225 mg of the two-peptide mixture was efficiently resolved, with high yields of homogeneous peptides, on analytical and semipreparative columns, respectively, containing the 15–20 μm packing. We have also demonstrated the potential of our purification procedure for resolving more complex multicomponent mixtures by efficiently separating a total of 22 mg of three closely-related peptides on analytical columns containing 7 μm or 15–20 μm particle size reversed-phase packings. The use of the inexpensive 15–20 μm packing, coupled with the ability to pack efficient columns with analytical HPLC instrumentation, offers great cost saving potential.  相似文献   
9.

Background  

The archaeal exosome is formed by a hexameric RNase PH ring and three RNA binding subunits and has been shown to bind and degrade RNA in vitro. Despite extensive studies on the eukaryotic exosome and on the proteins interacting with this complex, little information is yet available on the identification and function of archaeal exosome regulatory factors.  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号