首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 328 毫秒
1.
Chiral resolution of native DL-tartaric acid was performed by ligand-exchange capillary electrophoresis using copper(II)-D-quinic acid as a chiral selector. Factors affecting chiral resolution, migration time, and peak area of tartaric acid were studied. The running conditions for optimum separation of tartaric acid were found to be 1 mM copper(II) sulfate-10 mM D-quinic acid (pH 5.0) with an effective voltage of -15 kV at 30 degrees C, using direct detection at 250 nm, and resolution of racemic tartaric acid was approximately 1.3. With this system, chiral resolution of DL-tartaric acid in food products was conducted successfully.  相似文献   

2.
Dolezalová M  Fanali S 《Electrophoresis》2000,21(15):3264-3269
Capillary electrophoresis (CE) was successfully applied to the enantiomer resolution of racemic structurally related compounds, namely dihydroxyphenylalanine (DOPA), methyldihydroxyphenylalanine (MDOPA) and hydrazinomethyldihydroxyphenylalanine (CDOPA). The chiral resolution was performed in an untreated fused-silica capillary by using a phosphate buffer at pH 2.5 or 3.0 supplemented with sulfobutylated beta-cyclodextrin (SBE-CD). Resolution was strongly influenced by the concentration of the chiral selector added to the background electrolyte. In fact, 2-5 mM of SBE-CD enabled the resolution of DOPA and MDOPA enantiomers, while CDOPA optical isomers were resolved by using either 0.5 mM or 6-20 mM of SBE-CD. The latter separation conditions (reversed polarity mode) made it possible to obtain inversion of migration order.  相似文献   

3.
Using two kinds of central metal ions in a background electrolyte, ligand exchange CE was investigated for the simultaneous enantioseparation of dl ‐malic, dl ‐tartaric, and dl ‐isocitric acids. Ligand exchange CE with 100 mM d ‐quinic acid as a chiral selector ligand and 10 mM Cu(II) ion as a central metal ion could enantioseparate dl ‐tartaric acid but not dl ‐malic acid or dl ‐isocitric acid. A dual central metal ion system containing 0.5 mM Al(III) ion in addition to 10 mM Cu(II) ion in the background electrolyte enabled the simultaneous enantioseparation of the three α‐hydroxy acids. These results suggest that the use of a dual central metal ion system can be useful for enantioseparation by ligand exchange CE.  相似文献   

4.
Chiral resolution of native DL-malic acid was achieved by ligand-exchange capillary electrophoresis using copper(II)-L-tartrate as a chiral selector. Factors affecting chiral resolution, migration time, and peak area of malic acid were studied. The running conditions for optimum separation of malic acid were found to be 1 mM copper(II) sulfate-1 mM L-tartrate (pH 5.1) with an effective voltage of -20 kV at 30 degrees C, using direct detection at 280 nm, and resolution (Rs) of racemic malic acid was approximately 4. With this system, D- and L-malic acids in apple juice were analyzed successfully.  相似文献   

5.
Ali I  Aboul-Enein HY 《Electrophoresis》2003,24(12-13):2064-2069
The chiral resolution of baclofen was achieved by capillary electrophoresis using a fused-silica capillary (60 cm x 75 microm ID). The background electrolyte (BGE) was phosphate buffer (pH 7.0, 50 mM)-acetonitrile (95:5 v/v) containing 10 mM beta-cyclodextrin. The applied voltage was 15 kV. The values of alpha and R(s) were 1.06 and 1.00, respectively. The electrophoretic conditions were optimized varying the pH and the ionic strength of the BGE, concentrations of beta-cyclodextrin and acetonitrile and the applied voltage.  相似文献   

6.
Matsunaga H  Haginaka J 《Electrophoresis》2001,22(15):3251-3256
Separations of basic drug enantiomers by capillary electrophoresis (CE) using ovoglycoprotein (OGCHI) as a chiral selector are described. The effects of running buffer pH and 2-propanol content on the migration times and resolution of basic drug enantiomers were examined using a linear polyacrylamide-coated capillary. High resolution of basic drug enantiomers was attained using a mixture of 50 mM sodium phosphate buffer (pH 4.5-6.0) and 2-propanol (5-30%) including 50 microM OGCHI. It was found that ionic and hydrophobic interactions could work for the recognition of basic drug enantiomers. Further, we compared the chiral resolution ability of OGCHI with that of completely deglycosylated OGCHI (cd-OGCHI) using them as chiral selectors in CE. OGCHI showed higher resolution for basic drug enantiomers tested than cd-OGCHI. The results suggest that the chiral recognition site(s) for OGCHI exists on the protein domain of OGCHI.  相似文献   

7.
Edwards SH  Shamsi SA 《Electrophoresis》2002,23(9):1320-1327
Chiral separation of moderately to highly hydrophobic polychlorinated biphenyls (PCBs) using a conventional chiral micelle or a polymeric chiral surfactant, as the single chiral selector is very difficult since the hydrophobic interactions between the chiral PCB and the monomeric or polymeric surfactant is very strong. Combined use of a polymeric chiral surfactant, polysodium N-undecanoyl-D-valinate (poly-D-SUV) with hydroxypropyl-gamma-cyclodextrin (HP-gamma-CD) was successful in cyclodextrin modified electrokinetic chromatography (CD-EKC) enantioseparation of PCB congeners. Addition of HP-gamma-CD to the background electrolyte containing poly-D-SUV functioned to improved chiral resolution for the PCBs and reduce the analysis time for these congeners. In addition, concentration of methanol, concentration of 2-(N-cyclohexylamino) ethanesulfonic acid (CHES) buffer and separation voltage was also varied to optimize multicomponent separation of five chiral PCBs. Simultaneous separation and enantioseparation of all five PCBs was possible in less than 50 min under optimized conditions that requires a 5 mM CHES solution buffered at about pH 10 with 1.5% w/v (ca. 60 mM) poly-D-SUV and 16 mM HP-gamma-CD. In addition, 1 M urea and 20% v/v methanol should be added as organic modifier and the capillary temperature maintained at 45 degrees C. As expected the polymeric surfactant showed improved chiral resolution of PCBs over conventional micelles of SUV. Under optimized conditions, when CD-EKC of chiral PCBs using poly-D-SUV was compared to sodium dodecyl sulfate (SDS), better resolution, higher efficiency and shorter analysis time was achieved with poly-D-SUV.  相似文献   

8.
A new capillary electrophoretic method for the chiral separation of four major Cinchona alkaloids (quinine/quinidine and cinchonine/cinchonidine) was developed using heptakis-(2,6-di-O-methyl)-beta-cyclodextrin as the chiral selector. The inner walls of the separation capillary were modified with a thin polyacrylamide layer, which substantially reduced the electroosmotic flow and improved the chiral resolution and the reproducibility of the migration time of the analytes. Various operation parameters were optimised, including the pH, the capillary temperature, the concentration of the background electrolyte, and the concentration of the chiral selector. Baseline separation of the two diastereomer pairs was achieved in 12 minutes in ammonium acetate background electrolyte pH 5.0 with addition of cyclodextrin in a concentration of 3 mM or higher.  相似文献   

9.
The potential of tert.-butylcarbamoylquinine as chiral selector (SO) added to a non-aqueous background electrolyte for the capillary electrophoretic separation of the enantiomers of N-derivatized amino acids (selectands, SAs) is evaluated. Separation is based on different ion-pair formation equilibrium constants of (R) and (S) enantiomers of the negatively charged chiral analytes with the positively charged quinine-derived chiral SO and on mobility differences of free and complexed SAs, so that differences in the overall migration behavior of the SA enantiomers result. To suppress problems associated with the high UV absorption of the chiral SO and thus the high detector background in the 'total filling technique', the 'partial filling technique' has been adopted. Several parameters including filling time and length of SO zone, respectively, SO concentration, type of background electrolyte, have been evaluated. Using such an optimized method, for example, (R) and (S) enantiomers of 2,4-dinitrophenyl (DNP)-protected proline could be separated with alpha=1.08, R(S)=6.60, and N=130,000 theoretical plates within 15 min. Similar alpha values, resolution, and efficiencies were observed for other DNP-protected, as well as for diverse, N-derivatized amino acids like N-benzoyl, N-9-fluorenylmethoxycarbonyl, N-3,5-dinitrobenzyloxycarbonyl amino acids. A repeatability study clearly validated the robustness of the method and revealed its practical applicability.  相似文献   

10.
Nine racemic arylglycine amides were synthesized and successfully enantioseparated by capillary electrophoresis (CE) using highly sulfated beta-cyclodextrin (HS-beta-CD) as a chiral selector. Baseline enantioseparation of the analytes was obtained around neutral pH but not in the acidic conditions that are commonly used. HS-beta-CD content, buffer pH, type and concentration, and organic modifier concentration were studied and optimized for fast and efficient separation. A chiral CE separation system composed of 1.5% (w/v) HS-beta-CD, 0 to 10% (v/v) methanol and 20 mM 3-(N-morpholino)propanesulfonic acid at pH 6.5 was shown suitable for baseline enantioseparation of the mentioned amides within 6 min, including simultaneous enantioseparation of three positional isomer series (methyl-, methoxyl or chloro-substituted). By using this system, D-enantiomers migrated ahead of the L-enantiomers and the enantiomeric resolution order of arylglycine amides was more or less parallel to the pK(a), order of the analytes.  相似文献   

11.
Ong TT  Tang W  Muderawan W  Ng SC  Chan HS 《Electrophoresis》2005,26(20):3839-3848
Novel single isomers of positively charged beta-CDs were prepared via nucleophilic substitution of 6-monotosyl-beta-CD with alkylimidazoles to afford 6-mono(alkylimidazolium)-beta-CD tosylates and then 6-mono(alkylimidazolium)-beta-CD chlorides by anion exchange. The chiral resolution abilities of these cationic CDs were studied by CE using dansyl (Dns)-amino acids as model analytes. From the experimental results, it was found that both resolution and selectivity of these cationic CDs were dependent on the following parameters: concentration of chiral selectors, pH of the running buffer, counteranions of the CDs, side chain length of the n-alkyl-imidazolium cation, temperature of the capillary column, and organic modifier used. The concentration of chiral selectors required for enantioseparation varied from 3 to 30 mM. The BGE pH played an important role in the resolution of Dns-amino acids. For acidic BGEs, chiral resolution increased with pH (4.0-6.0) and reached a local maximum at pH 6.0. However, better resolutions were obtained with basic phosphate buffer at pH 9.6. Methanol was found to be an effective organic modifier for the resolution of Dns-amino acids by CE.  相似文献   

12.
DL-Penicillamine has been resolved into its enantiomers by normal-phase TLC using L-tartaric acid as chiral impregnating reagent as well as chiral mobile phase additive, while (R)-mandelic acid has been found to be successful as a chiral impregnating reagent. The solvent system acetonitrile-methanol-water (5:1:1, v/v) was found to be successful when L-tartaric acid was used as impregnating agent while the solvent combination acetonitrile-methanol-(0.5% l-tartaric acid in water, pH 5)-glacial acetic acid (7:1:1.1:0.7, v/v) was successful as mobile phase as it contained L-tartaric acid as the chiral additive. (R)-mandelic acid was successful as chiral impregnating reagent with ethyl acetate-methanol-water (3:1:1, v/v), as the mobile phase. The effects of concentration of chiral selectors, temperature and pH were examined on enantiomeric resolution. The spots were detected with iodine vapors and the detection limits were found to be 0.12 microg for each enantiomer of penicillamine with L-tartaric acid, under both the conditions, and 0.11 microg with (R)-mandelic acid.  相似文献   

13.
A liquid chromatographic chiral stationary phase (CSP) based on (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid was applied for the first time to the resolution of biologically important 1-aryl-1,2,3,4-tetrahydroisoquinolines. The unusual resolution of cyclic secondary amino compounds on a chiral crown ether-based CSP was quite successful with the use of a mixture of methanol-acetonitrile-triethylamine at a ratio of 30/70/0.5 (v/v/v) as a mobile phase. From the chromatographic behaviours for the resolution of seven 1-aryl-1,2,3,4-tetrahydroisoquinolines, the steric bulkiness of the 1-phenyl ring at the chiral center of analytes was concluded to play an important role in the chiral recognition.  相似文献   

14.
A chiral non-aqueous CE system with UV and mass spectrometric detection has been developed. The enantioseparation was promoted by diastereomeric complex (ion-pair) formation between the amines (e.g. salbutamol, atenolol) and the chiral selector, (-)-2,3:4,6-di-O-isopropylidene-2-keto-L-gulonic acid [(-)-DIKGA]. Different solvent mixtures were studied, as well as different concentrations of (-)-DIKGA and ammonium acetate in the background electrolyte. A partial filling technique was developed with a selector plug composed of (-)-DIKGA and ammonium acetate in a solvent mixture of methanol and 2-propanol. The separated enantiomers of pronethalol were detected by a Q-TOF MS system equipped with a sheath-flow electrospray ionization interface.  相似文献   

15.
A non-aqueous CE method was developed for evaluating the chiral discrimination potential of cinchona alkaloids and different kinds of carbamoylated derivatives of quinine and quinidine type chiral selectors towards acidic analytes, in particular a series of various Bz (benzoyl), DNB (3,5-dinitrobenzoyl) and DNZ (3,5-dinitrobenzyloxycarbonyl) amino acid derivatives. In this study, the enantioselectivity values obtained in non-aqueous CE with tert.-butyl carbamoylated quinine as chiral additive have been compared with the values found for the same series of selectands in HPLC using the same selector immobilized onto silica as chiral stationary phase. Similarly to the background electrolyte used in CE an ethanol-methanol mixture (60:40, v/v) containing 100 mM octanoic acid and 12.5 mM ammonia has been selected as HPLC mobile phase. Under these conditions, a good correlation (r = 0.954) between the enantioselectivities observed with the two techniques has been obtained. Thus the non-aqueous CE method can be applied as a screening tool for the rapid evaluation of the chiral discrimination potential of a large set of newly developed chiral selectors derived from quinine and related alkaloids.  相似文献   

16.
Diastereomers derived from (R,S)-tetrahydroisoquinoline-3-carboxylic acid (Tic), a potential neurotoxin with a chiral fluorescence tagging reagent, (R)-4-nitro-7-(3-aminopyrrolidin-1-yl)-2,1,3-benzoxadiazole (NBD-APy), are well resolved by capillary electrophoresis (CE). For a better understanding of the separation mechanism, a semiempirical computational method (i.e., AM1 method) is used to study the molecular geometry, relative energy, and size of the derivatives. The molecular sizes are estimated to be 216.3 and 240.6 cm3/mol for (R)-NBD-APy-(R)-Tic and (R)-NBD-APy-(S)-Tic, respectively. The CE elution order of the diastereomeric derivatives confirms the AM1 computational results: (R)-NBD-APy-(R)-Tic elutes before (R)-NBD-APy-(S)-Tic. The effects of running buffer pH and the addition of a chiral selector, beta-cyclodextrin (beta-CD), on the separation are studied. In the presence of beta-CD, the migration behavior of the diastereomers is changed because of the formation of CD inclusion complexes. Study of the space-filling models for optimized conformations of the diastereomeric derivatives and beta-CD suggests that the geometries of the diastereomers decides that the diastereomers are incorporated into the CD cavity to form CD inclusion complexes with different volumes. Experimental results from CE separations conclude the same.  相似文献   

17.
Han Y  Chen Y 《Electrophoresis》2007,28(15):2765-2770
A novel method has been developed for the on-column labeling of amino acid enantiomers with 9-fluoroenylmethyl chloroformate (FMOC), followed by chiral CE with a binary chiral selector system and UV detection. Efficient labeling was achieved by sequential injection of amino acids, borate buffer, and FMOC labeling solution at 0.2 psi for 6 s. After injection, the sandwich sections were electrically mixed at 250 V/cm for 6 s and allowed to react (electric field-free) at room temperature for 2 min. With this procedure, successful online-labeling and chiral CE separation of 19 pairs of amino acids (AA) have been conducted, giving 17 pairs fully enantioresolved (R(s) = 1.73-5.79) and two pairs partially resolved (Ala, R(s) = 0.39 and Arg, R(s) = 1.15) using a running buffer of 150 mM borate containing 30 mM beta-CD, 30 mM sodium taurodeoxycholate (STDC), and 15% isopropanol (IPA) at pH 9.0. Chiral CE of some mixed pairs was also demonstrated, much the same as using precolumn labeling. Surprisingly, Met, Asp, Asn, Gln, and His gained even higher enantioresolution (up to 2.5%) compared with the case of precolumn labeling. As validated by both artificially prepared solutions and serum samples, the method was applicable to the quantitative determination of AA, with LODs down to 4.0 microM. The method allowed the determination of D-AA at the ratio of 1:100 (D:L).  相似文献   

18.
The enantiomeric resolution of chiral phenoxy acid herbicides was performed by electrokinetic chromatography using a cyclodextrin as chiral pseudophase (CD-EKC). A systematic evaluation of several neutral and charged cyclodextrins was made. Among the cyclodextrins tested, (2-hydroxy)propyl beta-cyclodextrin (HP-beta-CD) was found to be the most appropriate for the enantioseparation of phenoxy acids. The influence of some experimental conditions, such as nature and pH of the background electrolyte, chiral selector concentration, and temperature, on the enantiomeric separation of phenoxy acids was also studied. The use of a 50 mM electrolyte solution in ammonium formate at pH 5 and a temperature of 40 degrees C enabled the enantiomeric resolution of four of the six phenoxy acids investigated (2-phenoxypropionic acid, 2(3-chlorophenoxy)propionic acid, 2-(4-chlorophenoxy)propionic acid, and 2-(2,4-dichlorophenoxy)propionic acid) obtaining migration times ranging from 9 to 15 min. Mixtures of the two phenoxy acids not enantiomerically resolved (2-(4-chlorophenoxy)-2-methylpropionic acid and 2-(2,4,5-trichlorophenoxy)propionic acid) and up to three of the phenoxy acids enantiomerically resolved were separated in about 15 min. Finally, the apparent binding constants for each enantiomer-HP-beta-CD pair were calculated at two temperature values (20 and 40 degrees C).  相似文献   

19.
Cation exchange type chiral stationary phases (CSPs) based on 3,5-dichlorobenzoyl amino acid and amino phosphonic acid derivatives as chiral selectors (SOs) and silica as chromatographic support were developed and applied to enantiomer separations of chiral bases by nonaqueous capillary electrochromatography (NA-CEC). As a rationale for efficient CSP development we adopted the combined use of the "reciprocity principle of chiral recognition" and nonaqueous ion-pair CE as screening assay. Thus, (S)-atenolol was employed as chiral counter-ion added to the BGE in CE and a series of N-derivatized amino acids and amino phosphonic acids were screened to derive reciprocally information on their chiral recognition abilities for atenolol enantiomers. Two SO candidates, namely N-(3,5-dichlorobenzoyl)-O-allyl-tyrosine and N-(4-allyloxy-3,5-dichlorobenzoyl)-1-amino-3-methylbutane phosphonic acid that have been identified as potential SOs in the CE screening were, after immobilization on thiol-modified silica, evaluated in cation-exchange NA-CEC. The strong chiral cation exchanger with the free phosphonic acid group exhibited enhanced enantioselectivity compared to the weak chiral cation exchanger with the carboxylic acid group. A wide variety of chiral bases could be successfully resolved on the strong chiral cation exchanger with alpha-values up to 2.2 and efficiencies up to 375000 m-1 including beta-blockers and other amino alcohols, local anesthetics like etidocaine, antimalarial agents like mefloquine, Tr?ger's base, phenothiazines like promethazine, and antihistaminics. The influence of several experimental parameters (electrolyte concentration, acid-base ratio and acetonitrile-methanol ratio) was evaluated.  相似文献   

20.
The chiral separation of simendan enantiomers using capillary electrophoresis was studied with beta-cyclodextrin (beta-CD) as chiral selector. The influences of the concentration and pH of borate buffer solution, beta-CD concentration and methanol content in the background electrolyte were investigated. These factors were compared with those in an HPLC with beta-CD as chiral mobile phase additive (CMPA-HPLC). The quantification properties of the developed CE method were examined. A baseline separation of simendan enantiomers was achieved in the background electrolyte of 20 mmol/L borate buffer (pH 11.0) containing 12 mmol/L beta-CD-methanol (50:50 in volume ratio). The CE method is comparable with CMPA-HPLC in chiral resolution, although the optimal pH in CE (11.0) is much higher than that (6.0) in CMPA-HPLC. This chiral CE method is applicable to the quantitative ananlysis and enantiomeric excess value determination of L-simendan.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号