首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
糖苷广泛存在于自然界中,常以糖苷酯形式存在,这有效地提高了它们的酯溶性,增加它们在肠内和胞内的吸收[1-3]。红景天苷是一种具有抗疲劳、抗辐射、抗缺氧、提高记忆、延缓衰老等药理活性的天然糖苷[4-8],在此先导化合物的基础上合成了各种红景天苷酯。本文对这类红景天苷酯的E  相似文献   

2.
Coupling mass spectrometers in tandem (MS/MS) can greatly increase the specificity of MS analysis without significantly decreasing its unusual sensitivity and speed, particularly for trace levels of preselected compounds in complex organic mixtures. MS/MS also gives more detailed structural information for larger organic molecules in submicrogram quantities.  相似文献   

3.
Two mass spectrometers, in parallel, were employed simultaneously for analysis of triacylglycerols in canola oil, for analysis of triolein oxidation products, and for analysis of triacylglycerol positional isomers separated using reversed-phase high-performance liquid chromatography. A triple quadrupole mass spectrometer was interfaced via an atmospheric pressure chemical ionization (APCI) interface to two reversed-phase liquid chromatographic columns in series. An ion trap mass spectrometer was coupled to the same two columns using an electrospray ionization (ESI) interface, with ammonium formate added as electrolyte. Electrospray ionization mass spectrometry (ESI-MS) under these conditions produced abundant ammonium adduct ions from triacylglycerols, which were then fragmented to produce MS/MS spectra and then fragmented further to produce MS/MS/MS spectra. ESI-MS/MS of the ammoniated adduct ions gave product ion mass spectra which were similar to mass spectra obtained by APCI-MS. ESI-MS/MS produced diacylglycerol fragment ions, and additional fragmentation (MS/MS/MS) produced [RCO](+) (acylium) ions, [RCOO+58](+) ions, and other related ions which allowed assignment of individual acyl chain identities. APCI-MS of triacylglycerol oxidation products produced spectra like those reported previously using APCI-MS. APCI-MS/MS produced ions related to individual fatty acid chains. ESI-MS of triacylglycerol oxidation products produced abundant ammonium adduct ions, even for those molecules which previously produced little or no intact molecular ions under APCI-MS conditions. Fragmentation (MS/MS) of the [M+NH(4)](+) ions produced results similar to those obtained by APCI-MS. Further fragmentation (MS/MS/MS) of the diacylglycerol fragments of oxidation products provided information on the oxidized individual fatty acyl chains. ESI-MS and APCI-MS were found to be complementary techniques, which together contributed to a better understanding of the identities of the products formed by oxidation of triacylglycerols.  相似文献   

4.
Tryptic digests were analyzed by means of online microbore liquid chromatography combined with mass spectrometry (LC/MS) for some common proteins. Following conventional enzymatic digestion with trypsin, the freeze-dried residues were dissolved in high-performance liquid chromatography (HPLC) eluent and subjected to gradient reversed-phase microbore HPLC separation with mass spectrometric detection. The latter was done in the full-scan single or tandem (MS/MS) mass spectrometry mode. The formation of gas-phase ions from dissolved analytes was accomplished at atmospheric pressure by pneumatically assisted electrospray (ion spray) ionization. This produced field-assisted ion evaporation of dissolved ions, which could then be mass-analyzed for molecular mass or structure. In the full-scan LC/MS mode, the masses for the peptide fragments in the tryptic digests can be determined as either their singly or multiply charged ions. When the molecular weights of the peptides lie outside the mass range of the mass spectrometer, the multiply charged feature of these experimental conditions still provides reliable molecular weight determinations. In addition, collision-activated dissociation (CAD) on selected peptide precursor ions provides online LC/MS/MS sequence information for the tryptic fragments. Results are shown for the tryptic digests of horse heart cytochrome c, bovine β-lactoglobulin A, and bovine β-lactoglobulin B.  相似文献   

5.
Quadrupole Orbitrap instruments (Q Orbitrap) permit high‐resolution mass spectrometry‐based full scan acquisitions and have a number of acquisition modes where the quadrupole isolates a particular mass range prior to a possible fragmentation and high‐resolution mass spectrometry‐based acquisition. Selecting the proper acquisition mode(s) is essential if trace analytes are to be quantified in complex matrix extracts. Depending on the particular requirements, such as sensitivity, selectivity of detection, linear dynamic range, and speed of analysis, different acquisition modes may have to be chosen. This is particularly important in the field of multi‐residue analysis (eg, pesticides or veterinary drugs in food samples) where a large number of analytes within a complex matrix have to be detected and reliably quantified. Meeting the specific detection and quantification performance criteria for every targeted compound may be challenging. It is the aim of this paper to describe the strengths and the limitations of the currently available Q Orbitrap acquisition modes. In addition, the incorporation of targeted acquisitions between full scan experiments is discussed. This approach is intended to integrate compounds that require an additional degree of sensitivity or selectivity into multi‐residue methods.  相似文献   

6.
Protein phosphorylation regulates many cellular processes and pathways, such as cell cycle progression, signal transduction cascades and gene expression. Selective detection of phosphopeptides from proteolytic digests is a challenging and highly relevant task in many proteomics applications. Often phosphopeptides are present in small amounts and need selective isolation or enrichment before identification. Here we report a novel approach to label selectively phospho-Ser/-Thr residues by exploiting the features of a novel linear ion trap mass spectrometer. Using dansyl labelling and MS3 fragmentation, we developed a method useful for the large-scale proteomic profiling of phosphorylation sites. The new residues in the sequence were stable and easily identifiable under general conditions for tandem mass spectrometric sequencing.  相似文献   

7.
The fragmentation pathways of seven types of taxoids were investigated by using a LC-MS/MS method, namely: (1) neutral taxoids with a C-4(20) double bond; (2) taxoids with a C-4(20) double bond and oxygenation at C-14; (3) 5-cinnamoyl taxoids with a C-4(20) double bond; (4) a basic taxoid with a C-4(20) double bond; (5) a taxoid with a C-4(20) epoxide; (6) taxoids with an oxetane ring; and (7) taxoids with an oxetane ring and a phenylisoserine C-13 side chain. Depending on the class of core structure and the substitution pattern, each taxoid gave either the molecular adduct ion [M+NH4]+ or [M+H]+. In the MS/MS, the molecular adduct ion gave characteristic product ions corresponding to the loss of water, acetic acid, benzoic acid, and cinnamic acid or the phenylisoserine group. These could reflect the difference of the substitutions and structural modifications and should be utilized for the structure elucidation oftaxoids by LC-MS.  相似文献   

8.
9.
A simple and robust impulse-driven droplet deposition system was developed for off-line liquid chromatography matrix-assisted laser desorption ionization mass spectrometry (LC-MALDI MS). The system uses a solenoid operated with a pulsed voltage power supply to generate impulses that dislodge the hanging droplets from the LC outlet directly to a MALDI plate via a momentum transfer process. There is no contact between the LC outlet and the collection surface. The system is compatible with solvents of varying polarity and viscosity, and accommodates the use of hydrophobic and hydrophilic MALDI matrices. MALDI spots are produced on-line with the separation, and do not require further processing before MS analysis. It is shown that high quality MALDI spectra from 5 fmol of pyro-Glu-fibrinopeptide deposition after LC separation could be obtained using the device, indicating that there was no sample loss in the interface. To demonstrate the analytical performance of the system as a proteome analysis tool, a range of BSA digest concentrations covering about 3 orders of magnitude, from 5 fmol to 1 pmol, were analyzed by LC-MALDI quadrupole time-of-flight MS, yielding 6 and 57% amino acid sequence coverage, respectively. In addition, a complex protein mixture of an E. coli cell extract was tryptically digested and analyzed by LC-MALDI MS, resulting in the detection of a total of 409 unique peptides from 100 fractions of 15-s intervals.  相似文献   

10.
王志鹏  王鑫  刘伟 《化学教育》2017,38(12):1-6
串级质谱(MS/MS)分析是近年来迅猛发展的仪器分析技术,对于化学相关学科与其他交叉领域都起到了极大的推动作用。在使用计算机辅助解析后,常常需要进一步进行图谱指认,而这部分内容常常被化学教学所忽略。从串级质谱的原理出发,详细分析了肽段在二级质谱中可能的断裂模式与结构特性,并进一步以模型蛋白为例详细分析了串级质谱的图谱指认和峰的归属的基本原理与实用性方法,以期对教学与科研有助。  相似文献   

11.
12.
Summary. This study was aimed at analyzing the daughter ion spectra of 7 toxicologically relevant cholesterol oxidation products (COPs) i.e. cholestanetriol (cholestane-3β,5α,6β-triol), 7-ketocholesterol (cholest-5-en-3β-ol-7-one), 7α-hydroxycholesterol (cholest-5-en-3β,7α-diol), 7β-hydroxycholesterol (cholest-5-en-3β,7β-diol), 25-hydroxycholesterol (cholest-5-en-3β,25-diol), α-epoxycholesterol (cholestane-5α,6α-epoxy-3β-ol) and β-epoxycholesterol (cholestane-5β,6β-epoxy-3β-ol). In addition, 19-hydroxycholesterol (cholest-5-en-3β,19-diol) was analyzed as this serves as internal standard in COPs determination by HPLC-MS. Mass spectrometry was performed using a triple quadrupol mass spectrometer that was equipped with an APCI ion source. Our results indicate a common fragmentation pattern for COPs. The main breaking sites identified were in the sterol ring system between the carbon atoms with the position numbers 11–12, 12–13, and 8–14. Typical daughter ions of m/z = 81, 95, and 195 were used for multiple reaction monitoring analysis.  相似文献   

13.
High-throughput quantitative bioanalysis by LC/MS/MS   总被引:8,自引:0,他引:8  
This review article discusses the most recent significant advances in the sample preparation and mass spectrometry aspects of high-throughput bioanalysis by LC/MS/MS for the quantitation of drugs, metabolites and endogenous biomolecules in biological matrices. The introduction and implementation of automated 96-well extraction has brought about high-throughput approaches to the biological sample preparation techniques of solid-phase extraction, liquid-liquid extraction and protein precipitation. The fast-flow on-line extraction technique is a different high-throughput approach that has also significantly speeded up analysis by LC/MS/MS. The use of pierceable caps for biological tubes further enhances the analysis speed and improves the safety in handling biological samples. The need for adequate chromatographic separation in order to eliminate interferences due to metabolites and/or matrix effects in LC/MS/MS is discussed. To highlight our limited understanding of atmospheric pressure ionization mass spectrometry, results from recent investigations that appear to be counter-intuitive are presented. Looking ahead to the future, multiplexed LC/MS/MS systems and capillary LC are presented as areas that can bring about further improvements in analysis speed and sensitivity to quantitative bioanalysis by LC/MS/MS.  相似文献   

14.
15.
Bovine ribonuclease B (RNAse B) and asialofetuin (FETUA) were subjected to in-capillary tryptic digest (Pohlentz et al. Proteomics. 2005, 5, 1758-1763) and the obtained glycopeptides were analyzed, respectively, by nanoelectrospray ionization mass spectrometry and collision-induced dissociation (CID) during the ongoing digest. For RNAse, B glycans of the high-mannose type (Man(4) to Man(9)) attached to either a tetra- or a hexapeptide containing the sole N-glycosylation site of the protein were detected. Glycopeptides derived from all three N-glycosylation sites of FETUA were observed, and the corresponding CID spectra proved the respective glycans to be oligosaccharides of the triantennary complex type. Moreover, an O-glycopeptide carrying Gal-GalNAc at T(280) could be unambiguously identified. An in-solution tryptic/chymotryptic digest of human transferrin (TRFE) was analyzed directly for glycopeptides subsequent to the addition of methanol and formic acid. Disialylated diantennary glycans were observed in glycopeptides of both N-glycosylation sites of TRFE. These results demonstrate the feasibility of direct structure determination of glycopeptides in proteolytic mixtures without any further refurbishment.  相似文献   

16.
Steroid sex hormones and related synthetic compounds have been shown to provoke alarming estrogenic effects in aquatic organisms, such as feminization, at very low concentrations (ng/L or pg/L). In this work, different chromatographic techniques, namely, gas chromatography/mass spectrometry (GC/MS), liquid chromatography/mass spectrometry (LC/MS) and liquid chromatography/tandem mass spectrometry (LC/MS/MS), are discussed for the analysis of estrogens, both free and conjugated, and progestogens, and the sensitivities achieved with the various techniques are inter-compared. GC/MS analyses are usually carried out after derivatization of the analytes with bis(trimethylsilyl)trifluoroacetamide (BSTFA). For LC/MS and LC/MS/MS analyses, different instruments, ionization techniques (electrospray (ESI) and atmospheric pressure chemical ionization (APCI)), ionization modes (negative ion (NI) and positive ion (PI)) and monitoring modes (selected ion monitoring (SIM) and selected reaction monitoring (SRM)) are generally employed. Based on sensitivity and selectivity, LC/ESI-MS/MS is generally the method of choice for determination of estrogens in the NI mode and of progestogens in the PI mode (instrumental detection limits (IDLs) 0.1-10 ng/mL). IDLs achieved by LC/ESI-MS in the SIM mode and by LC/ESI-MS/MS in the SRM mode were, in general, comparable, although the selectivity of the latter is significantly higher and essential to avoid false positive determinations in the analysis of real samples. Conclusions and future perspectives are outlined.  相似文献   

17.
A multiplexed method for performing MS/MS on multiple ions simultaneously in a miniature rectilinear ion trap (RIT) mass spectrometer has been developed. This method uses an ion encoding procedure that relies on the mass bias that exists when ions are externally injected into an RIT operated with only a single phase rf applied to one pair of electrodes. The ion injection profile under such conditions ions is Gaussian-like over a wide range of rf amplitudes, or low mass cutoff (LMCO) values, during ion accumulation. We show that this distribution is related to ion m/z and is likely caused by ions having an optimal range of pseudo-potential well depths for efficient trapping. Based on this observation, precursor ion intensity changes between two different injection LMCO values can be predicted, and these ion intensity changes are found to be carried through to their corresponding product ions, enabling multiplexed MS/MS spectra to be deconvoluted.  相似文献   

18.
LC/MS/MS方法筛查新生儿苯丙酮尿症   总被引:6,自引:1,他引:5  
苯丙酮尿症 [1~ 4 ] ( PKU )发病原因是患者基因缺陷使肝脏不能合成苯丙氨酸羟化酶而导致体内苯丙氨酸 ( Phe)不能正常代谢为酪氨酸 ( Tyr) ,前者在体内大量堆积并氧化为对人体有害的苯丙酮酸 . PKU是目前筛查范围最广的氨基酸代谢遗传疾病 ,在全世界每年 [5]约有一千万婴儿接受 PKU筛查 ;在我国 ,PKU也是卫生部要求重点筛查的病种 .Chace[5]等在 1 993年报道了 MS/ MS方法筛查新生儿PKU:直接使用 MS/ MS的中性碎片丢失扫描方式检测 Phe和 Tyr,通过氘代内标与待测氨基酸的质谱峰高比来定量 .MS/ MS方法速度快、准确性好、可以…  相似文献   

19.
Phthalocyanines are a class of macrocyclic organic compounds known for their high tinctorial properties, thermal stability, chemical inertness, catalytic activity, and photoconductivity. A mass spectral study on metal phthalocyanines presented many difficulties because of their excellent thermal stability. The present work deals with MS and GC–MS studies of phthalocyanine, copper, and nickel phthalocyanine monomers at various temperatures. Tentative mechanism for the modes of fragmentation is proposed.  相似文献   

20.
Ivermectin is a semisynthetic macrocyclic lactone anthelmintic of the avermectin family derived from Streptomyces fermentation products. Avermectins are used as antiparasitic agents in domestic animals; although considered relatively safe, one must consider animal species, breed, weight, and age in dosage determinations.In January 2006, two canines were presented to the UK Livestock Disease Diagnostic Center after dying from suspected ivermectin overdoses [30-50 mg/kg body weight]. To confirm this clinical diagnosis we developed a rapid, sensitive semiquantitative ElectroSpray Ionization-Mass Spectrometry (ESI/MS) method for ivermectin in canine tissue samples. Pharmaceutical ivermectin contains two ivermectins differing by a single methyl group, and each compound forms interpretation-confounding adducts with tissue Na(+) and K(+) ions. We now report that ivermectin administration was clearly confirmed by comparison with standard and dosage forms of ivermectin, and simple proportionalities based on mass spectral intensity of respective molecular ions allowed semiquantitative estimates of injection site tissue concentrations of 20 and 40 microg/g tissue (wet weight) in these animals, consistent with the history of ivermectin administration and the clinical signs observed.There is a distinct need for both rapid detection and confirmation of toxic exposures in veterinary diagnostics, whether for interpretation of clinical cases antemortem or for forensic reasons postmortem. It is vital that interpreters of analytical results have appropriate guidance in the scientific literature and elsewhere so as to enable clear-cut answers. The method presented here is suitable for routine diagnostic work in that it allows rapid extraction of ivermectin from tissue samples, avoids the need for high-performance liquid chromatography and allows ready interpretation of the multiple ivermectin species seen by ESI(+) MS/MS in samples originating from veterinary dosage forms.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号