首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Secondary organic aerosol (SOA) is formed when organic molecules react with oxidants in the gas phase to form particulate matter. Recent measurements have shown that more than half of the mass of laboratory-generated SOA consists of high molecular weight oligomeric compounds. In this work, the formation mechanisms of oligomers produced in the laboratory by ozonolysis of α-pinene, an important SOA precursor in ambient air, are studied by MS and MS/MS measurements with high accuracy and resolving power to characterize monomer building blocks and the reactions that couple them together. The distribution of oligomers in an SOA sample is complex, typically yielding over 1000 elemental formulas that can be assigned from an electrospray ionization mass spectrum. Despite this complexity, MS/MS spectra can be found that give strong evidence for specific oligomer formation pathways that have been postulated but not confirmed. These include aldol and gem-diol reactions of carbonyls as well as peroxyhemiacetal formation from hydroperoxides. The strongest evidence for carbonyl reactions is in the formation of hydrated products. Less compelling evidence is found for dehydrated products and secondary ozonide formation. The number of times that a monomer building block is observed as a fragmentation product in the MS/MS spectra is shown to be independent of the monomer vapor pressure, suggesting that oligomer formation is not driven by equilibrium partitioning of a monomer between the gas and particle phases, but rather by reactive uptake where a monomer collides with the particle surface and rapidly forms an oligomer.  相似文献   

2.
以煤和生物质为主要原料的商用型煤为研究对象,采用还原热解(AP-TPR)在线质谱(MS)联用,以及离线色谱/质谱(GC/MS)分析法,定性和定量研究了家用型煤释放的含硫化合物。不同组成的型煤表现出各自不同的硫释放特性。对于生物型煤来说,仅检测到少量二烷基硫醚和脂肪硫醇的存在。褐煤型煤检测到种类最多的有机硫化物。在高阶煤制成的型煤中没有检测到氧化态的硫化物,其典型特征是存在一些噻吩类硫化物。  相似文献   

3.
The present work describes the development and optimization of a capillary (zone) electrophoresis/mass spectrometric (CE/MS) analysis method for polar hydrophilic aromatic sulfonates (ASs). The compounds were detected by negative ion electrospray ionization (NIESI) and selected ion monitoring (SIM). In comparison with CE/UV, for CE/MS a lower-concentration volatile ammonium acetate buffer (5 mM) without organic modifier and a higher separation voltage were better suited for separation. Sensitivity of CE/MS was slightly better than for CF/UV, with the limit of detection (LOD) ranging between 0.1 and 0.4 mg l(-1). For verification of the CE/MS results, ASs were also analysed by ion-pair liquid chromatography/diode array UV detection coupled in series with electrospray mass spectrometry (IPC/DAD/ESI-MS). Real water samples of different waste water treatment plants (WWTPs) in Catalonia (NE Spain) were extracted by solid-phase extraction (SPE) with LiChrolut EN and analysed with CE/MS and LC/MS. ASs were found in influent and effluent water samples of the WWTPs in the microg l(-1) concentration range. LC/MS offered a higher separation efficiency and sensitivity than CE/MS. Therefore with LC/MS more compounds could be identified in the WWTPs. The persistency of the ASs was distinct: some compounds were well degraded during the water treatment process, while others were quite persistent.  相似文献   

4.
Matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI TOF MS) was used to analyze a series of synthetic organic ions bearing fixed multiple charges. Despite the multiple intrinsic charges, only singly charged ions were recorded in each case. In addition to the pseudo‐molecular ions formed by counterion adduction, deprotonation and electron capture, a number of fragment ions were also observed. Charge splitting by fragmentation was found to be a viable route for charge reduction leading to the formation of the observed singly charged fragment ions. Unlike multivalent metal ions, organic ions can rearrange and/or fragment during charge reduction. This fragmentation process will evidently complicate the interpretation of the MALDI MS spectrum. Because MALDI MS is usually considered as a soft ionization technique, the fragment ion peaks can easily be erroneously interpreted as impurities. Therefore, the awareness and understanding of the underlying MALDI‐induced fragmentation pathways is essential for a proper interpretation of the corresponding mass spectra. Due to the fragment ions generated during charge reduction, special care should be taken in the MALDI MS analysis of multiply charged ions. In this work, the possible mechanisms by which the organic ions bearing fixed multiple charges fragment are investigated. With an improved understanding of the fragmentation mechanisms, MALDI TOF MS should still be a useful technique for the characterization of organic ions with fixed multiple charges.  相似文献   

5.
毛细管色谱-质谱法测定了环境大气中挥发性污染物。用液氧冷冻法和常温吸附法(TenaxGC)分别采集大气样品,然后用两种系统进行浓缩,并进入毛细管色谱-质谱体系,完成了有机污染物的定性定量分析。解决了一些色谱-质谱联用中的问题。并且还讨论了无分流进样问题,比较了两种采样方法。用此方法测定了某炼油厂环境大气中的污染物。  相似文献   

6.
Phthalocyanines are a class of macrocyclic organic compounds known for their high tinctorial properties, thermal stability, chemical inertness, catalytic activity, and photoconductivity. A mass spectral study on metal phthalocyanines presented many difficulties because of their excellent thermal stability. The present work deals with MS and GC–MS studies of phthalocyanine, copper, and nickel phthalocyanine monomers at various temperatures. Tentative mechanism for the modes of fragmentation is proposed.  相似文献   

7.
Everolimus (40-O-(2-hydroxyethyl)rapamycin, Certican) is a 31-membered macrolide lactone. In lymphocytes, it inhibits the mammalian target of rapamycin (mTOR) and is used as an immunosuppressant after organ transplantation. Due to its instability in pure organic solvents and insufficient HPLC separation, NMR spectroscopy analysis of its metabolite structures is nearly impossible. Therefore, structural identification based on tandem mass spectrometry (MS/MS) and MS(n) fragmentation patterns is critical. Here, we have systematically assessed the fragmentation pattern of everolimus during liquid chromatography (LC)-electrospray ionization (ESI)-MS/MS and validated the fragment structures by (1) comparison with structurally identified derivatives (sirolimus), (2) high-resolution mass spectrometry, (3) elucidation of fragmentation pathways using ion trap mass spectrometry (up to MS(5)) and (4) H/D exchange. In comparison with the structurally related immunosuppressants tacrolimus and sirolimus, our study was complicated by the low ionization efficiency of everolimus. Detection of positive ions gave the best sensitivity, and everolimus and its fragments were mainly detected as sodium adducts. LC-ESI-MS/MS of everolimus in combination with collision-induced dissociation (CID) resulted in a complex fragmentation pattern and the structures of 53 fragments were identified. These detailed fragmentation pathways of everolimus provided the basis for structural elucidation of all everolimus metabolites generated in vivo und in vitro.  相似文献   

8.
The analysis of low volatile compounds by (GC)2/MS using high-temperature stable glass-capillary columns and a commercially available GC/quadrupole MS instrument is described. It will be shown that no special modifications or procedures are required in analyzing organic compounds exceeding carbon numbers of 50. The application to industrially and naturally occuring high boiling mixtures will be discussed.  相似文献   

9.
A new analytical technique for the structural elucidation of four representative phenidate analogues possessing a secondary amine residue, which leads to a major/single amine‐representative fragment/product ion at m/z 84 both in their GC‐EI‐MS and LC‐ESI‐MS/MS spectra, making their identification ambiguous, was developed. The method is based on “in vial” chemical derivatization with isobutyl chloroformate in both aqueous and organic solutions, followed by liquid chromatography‐electrospray ionization mass spectrometry (LC‐ESI‐MS/MS). The resulting carbamate derivatives promote rich fragmentation patterns with full coverage of all substructures of the molecule, enabling detailed structural elucidation and unambiguous identification of the original compounds at low ng/mL levels.  相似文献   

10.
Two mass spectrometers, in parallel, were employed simultaneously for analysis of triacylglycerols in canola oil, for analysis of triolein oxidation products, and for analysis of triacylglycerol positional isomers separated using reversed-phase high-performance liquid chromatography. A triple quadrupole mass spectrometer was interfaced via an atmospheric pressure chemical ionization (APCI) interface to two reversed-phase liquid chromatographic columns in series. An ion trap mass spectrometer was coupled to the same two columns using an electrospray ionization (ESI) interface, with ammonium formate added as electrolyte. Electrospray ionization mass spectrometry (ESI-MS) under these conditions produced abundant ammonium adduct ions from triacylglycerols, which were then fragmented to produce MS/MS spectra and then fragmented further to produce MS/MS/MS spectra. ESI-MS/MS of the ammoniated adduct ions gave product ion mass spectra which were similar to mass spectra obtained by APCI-MS. ESI-MS/MS produced diacylglycerol fragment ions, and additional fragmentation (MS/MS/MS) produced [RCO](+) (acylium) ions, [RCOO+58](+) ions, and other related ions which allowed assignment of individual acyl chain identities. APCI-MS of triacylglycerol oxidation products produced spectra like those reported previously using APCI-MS. APCI-MS/MS produced ions related to individual fatty acid chains. ESI-MS of triacylglycerol oxidation products produced abundant ammonium adduct ions, even for those molecules which previously produced little or no intact molecular ions under APCI-MS conditions. Fragmentation (MS/MS) of the [M+NH(4)](+) ions produced results similar to those obtained by APCI-MS. Further fragmentation (MS/MS/MS) of the diacylglycerol fragments of oxidation products provided information on the oxidized individual fatty acyl chains. ESI-MS and APCI-MS were found to be complementary techniques, which together contributed to a better understanding of the identities of the products formed by oxidation of triacylglycerols.  相似文献   

11.
This study describes a method for the simultaneous determination of 12 synthetic cannabinoids by MEKC–MS/MS using a volatile surfactant (ammonium perfluorooctanoate) as a constituent of the micellar pseudostationary phase. Although most synthetic cannabinoids comigrated by a CZE method, sufficient separation could be achieved by the proposed method. The best separation was made possible by 50 mM ammonium perfluorooctanoate in 20% v/v acetonitrile/water (apparent pH* 9.0) as the BGE, followed by MS detection using a sheath liquid composed of 5 mM ammonium formate in 50% v/v methanol/water mixed hydro‐organic solvent. The standard calibration curve for all analytes showed good linearity (r > 0.99). Satisfactory recoveries, ranging from 89.5 to 101.7%, were obtained. The LODs were 6.5–76.5 μg/g for the target analytes. This method appears to be a useful tool for the identification of synthetic cannabinoids in illegal herbal incense blends.  相似文献   

12.
The goal of this work was to evaluate the improvement in proteome coverage of complex protein mixtures gained by analyzing samples using both LC/ESI/MS/MS and LC/MALDI/MS/MS. Parallel analyses of a single sample were accomplished by interfacing a Probot fractionation system with a nanoscale LC system. The Probot was configured to perform a post-column split such that a fraction (20%) of the column effluent was sent for on-line LC/ESI/MS/MS data acquisition, and the majority of the sample (80%) was mixed with a matrix solution and deposited onto the MALDI target plate. The split-flow approach takes advantage of the concentration sensitive nature of ESI and provides sufficient quantity of sample for MALDI/MS/MS. Hybrid quadrupole time-of-flight mass spectrometers were used to acquire LC/ESI/MS/MS data and LC/MALDI/MS/MS data from a tryptic digest of a preparation of mammalian mitochondrial ribosomes. The mass spectrometers were configured to operate in a data dependent acquisition mode in which precursor ions observed in MS survey scans are automatically selected for interrogation by MS/MS. This type of acquisition scheme maximizes the number of peptide fragmentation spectra obtained and is commonly referred to as shotgun analysis. While a significant degree of overlap (63%) was observed between the proteins identified in the LC/ESI/MS/MS and LC/MALDI/MS/MS data sets, both unique peptides and unique proteins were observed by each method. These results demonstrate that improved proteome coverage can be obtained using a combination of these ionization techniques.  相似文献   

13.
An analytical method has been developed which allows the determination of 22 different neutral and weakly basic drugs belonging to several different medicinal classes like antiphlogistics, betablockers, β2-sympathomimetics, lipid regulators, antiepileptic agents, psychiatric drugs and vasodilators in waste water as well as in river and drinking water. A method including solid phase extraction, derivatization by silylation and detection by GC/MS permits detection down to 5 ng/L. The recovery rates mostly exceeded 70%. However, the determination of phenazone, carbamazepine, cyclophosphamide, ifosfamide and pentoxiphylline is frequently disturbed by organic co-extractants in real samples of rivers and waste waters. Therefore, a time saving alternative method has been developed, combining solid phase extraction (as an enrichment step) together with detection by LC-electrospray/MS/MS allowing the measurement of 5 neutral drugs. Detection limits down to 10 ng/L have been achieved even for organically highly contaminated waters like sewage treatment plant effluents.  相似文献   

14.
High-throughput quantitative bioanalysis by LC/MS/MS   总被引:8,自引:0,他引:8  
This review article discusses the most recent significant advances in the sample preparation and mass spectrometry aspects of high-throughput bioanalysis by LC/MS/MS for the quantitation of drugs, metabolites and endogenous biomolecules in biological matrices. The introduction and implementation of automated 96-well extraction has brought about high-throughput approaches to the biological sample preparation techniques of solid-phase extraction, liquid-liquid extraction and protein precipitation. The fast-flow on-line extraction technique is a different high-throughput approach that has also significantly speeded up analysis by LC/MS/MS. The use of pierceable caps for biological tubes further enhances the analysis speed and improves the safety in handling biological samples. The need for adequate chromatographic separation in order to eliminate interferences due to metabolites and/or matrix effects in LC/MS/MS is discussed. To highlight our limited understanding of atmospheric pressure ionization mass spectrometry, results from recent investigations that appear to be counter-intuitive are presented. Looking ahead to the future, multiplexed LC/MS/MS systems and capillary LC are presented as areas that can bring about further improvements in analysis speed and sensitivity to quantitative bioanalysis by LC/MS/MS.  相似文献   

15.
An analytical method has been developed which allows the determination of 22 different neutral and weakly basic drugs belonging to several different medicinal classes like antiphlogistics, betablockers, β2-sympathomimetics, lipid regulators, antiepileptic agents, psychiatric drugs and vasodilators in waste water as well as in river and drinking water. A method including solid phase extraction, derivatization by silylation and detection by GC/MS permits detection down to 5 ng/L. The recovery rates mostly exceeded 70%. However, the determination of phenazone, carbamazepine, cyclophosphamide, ifosfamide and pentoxiphylline is frequently disturbed by organic co-extractants in real samples of rivers and waste waters. Therefore, a time saving alternative method has been developed, combining solid phase extraction (as an enrichment step) together with detection by LC-electrospray/MS/MS allowing the measurement of 5 neutral drugs. Detection limits down to 10 ng/L have been achieved even for organically highly contaminated waters like sewage treatment plant effluents. Received: 18 November 1997 / Revised: 18 March 1998 / Accepted: 21 March 1998  相似文献   

16.
Groundwater samples from a former gas plant site were investigated by headspace GC/MS and general parameters with regard to organic pollution. The contamination plume was distinguished from background with GC/MS headspace and dissolved organic carbon analyses. Headspace GC/MS analyses of these samples revealed the presence of several aromatic and heterocyclic compounds typical to coal tar leachates. Selected ion monitoring GC/MS was used to establish the relative contamination level of seven selected polycyclic aromatic hydrocarbons (PAH) from 9 sampling wells. Three wells showed a high contamination level and therefore, they could be attributed to the vicinity of contamination sources. Well samples downgradient from the pollution source showed decreasing contamination levels for all compounds except acenaphthene.  相似文献   

17.
随着地质勘探研究工作的深入和发展,一些常规检测的生物标记化合物,已无法满足特殊区域地质研究的需要,地球化学家把注意力放在一些含量极微,但具有明确断代标志意义或明确生源的标志物身上,而这些组分靠常规的GC-MS分析根本检测不到。而GC-MS/MS由于是二级质谱串联比GC-MS增加  相似文献   

18.
Methylation is one of the important posttranslational modifications of biological systems. At the metabolite level, the methylation process is expected to convert bioactive compounds such as amino acids, fatty acids, lipids, sugars, and other organic acids into their methylated forms. A few of the methylated amino acids are identified and have been proved as potential biomarkers for several metabolic disorders by using mass spectrometry–based metabolomics workstation. As it is possible to encounter all the N‐methyl forms of the proteinogenic amino acids in plant/biological systems, it is essential to have analytical data of all N‐methyl amino acids for their detection and identification. In earlier studies, we have reported the ESI‐MS/MS data of all methylated proteinogenic amino acids, except that of mono‐N‐methyl amino acids. In this study, the N‐methyl amino acids of all the amino acids ( 1 ‐ 21 ; including one isomeric pair) were synthesized and characterized by ESI‐MS/MS, LC/MS/MS, and HRMS. These data could be useful for detection and identification of N‐methyl amino acids in biological systems for future metabolomics studies. The MS/MS spectra of [M + H]+ ions of most N‐methyl amino acids showed respective immonium ions by the loss of (H2O, CO). The other most common product ions detected were [MH‐(NH2CH3]+, [MH‐(RH)]+ (where R = side chain group) ions, and the selective structure indicative product ions due to side chain and N‐methyl group. The isomeric/isobaric N‐methyl amino acids could easily be differentiated by their distinct MS/MS spectra. Further, the MS/MS of immonium ions inferred side chain structure and methyl group on α‐nitrogen of the N‐methyl amino acids.  相似文献   

19.
Modification of commercial LC/MS instrumentation to allow both atmospheric pressure (AP) LC/MS and GC/MS is described. Advantages of this additional capability versus LC/MS alone include higher chromatographic resolution in the GC versus LC mode, greater peak capacity for complex mixture analysis, higher sensitivity for a variety of volatile compounds, and the ability to observe compounds of low polarity that are not readily observed in LC/MS. Advantages over conventional GC/MS include the ability to use higher carrier gas flow and shorter columns for passing less volatile materials through the gas chromatograph, selective ionization, and rapid switching between positive and negative ion modes. Other advantages include application of the enhanced capabilities of LC/MS instrumentation to GC/MS analyses such as cone voltage fragmentation, MS(n), high mass resolution, and accurate mass measurement. Limitations of APGC/MS include the inability to observe saturated hydrocarbon and certain other highly nonpolar compounds and less odd-electron fragmentation for computer aided library searching. For some analyses, the limitation related to ionization of highly nonpolar compounds is advantageous, as is the simplified mass spectrum and easy molecular weight identification that results from less fragmentation observed in the AP ionization mode.  相似文献   

20.
Their characteristics as persistent organic pollutant and their toxicity (2,3,7,8-TCDD is named as a known human carcinogen) make the dioxins and related compounds a focus of interest in environmental analytical chemistry. In view of the widespread distribution of dioxins in the environment, these compounds must be monitored in several matrices, such as air, effluents, soil, sludge and biological samples. The analytical methodologies are especially difficult owing to the complexity of the mixtures of congeners (210 PCDD/Fs and 209 PCBs) and to the low detection limits required (ppb to ppq). Moreover, time-consuming sample preparation steps are needed owing to the presence of a large number of interfering compounds. The different toxicity of each congener requires the development of congener specific methods. This review of trace dioxin determination by mass spectrometry (MS) includes sample preparation and chromatographic separation. In this Special Feature, the use of different MS techniques such as low-resolution MS (LRMS) and high-resolution MS (HRMS) is discussed in terms of selectivity and sensitivity. The performances of other MS techniques, such as tandem MS (MS/MS) and time-of-flight MS (ToFMS), are compared. Quantification techniques, especially the isotopic dilution method, are also discussed. Conclusions and future perspectives are outlined.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号