首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Shenkang injection is a traditional Chinese formula with good curative effect on chronic renal failure. In this paper, a novel, rapid and sensitive ultra‐high‐performance liquid chromatography coupled with Q Exactive hybrid quadrupole Orbitrap high‐resolution accurate mass spectrometry was developed and validated for simultaneous determination of seven bioactive constituents of Shenkang injection in rat plasma and tissues after intravenous administration. Acetonitrile was used as a protein precipitation agent in biological samples disposal with carbamazepine as internal standard. The chromatographic separation was carried out on a C18 column with a gradient mobile phase consisting of acetonitrile and water (containing 0.1% formic acid). The MS analysis was performed in the full‐scan positive and negative ion mode. The lower limits of quantification for the seven analytes in rat plasma and tissues were 0.1–10 ng/mL. The validated method was successfully applied to tissue distribution and pharmacokinetic studies of Shenkang injection after intravenous administration. The results of the tissue distribution study showed that the high concentrations of seven constituents were primarily in the kidney tract. This is the first report of the application of Q‐Orbitrap with full‐scan mass spectrometry in tissue distribution and pharmacokinetic studies of Shenkang injection.  相似文献   

2.
Gas chromatography with electron ionization and full scan high resolution mass spectrometry with an Orbitrap mass analyzer (GC-EI-full scan Orbitrap HRMS) was evaluated for residue analysis. Pesticides in fruit and vegetables were taken as an example application.  相似文献   

3.
A simple and rapid method was developed for the determination of three free cytokinins, namely, N6‐(Δ2‐isopentenyl)adenine, zeatin, and dihydrozeatin, in plants using TurboFlow on‐line cleanup liquid chromatography combined with hybrid quadrupole‐Orbitrap high‐resolution mass spectrometry. The samples were extracted using acetonitrile, and then the extract was purified on a C18‐p column, in which the sample matrix was removed and the analytes were retained. Subsequently, the analytes were eluted from the extraction column onto the analytical column (Hypersil Gold C18 column) prior to chromatographic separation and hybrid Q‐Orbitrap detection using the targeted‐MS2 scan mode. The linearity was satisfactory with a correlation coefficient of >0.999 at concentrations ranging from 5–5000 pg/mL. The limits of quantification for the analytes ranged from 4.2–5.2 pg/mL. The intra‐ and inter‐day average recoveries of analytes fortified at three levels ranged from 85.4–108.2%, and the intra‐ and inter‐day relative standard deviations ranged from 4.04–8.57%. The method was successfully applied for the determination of free cytokinins in different tissue samples of Oryza sativa and Arabidopsis thaliana.  相似文献   

4.
In this work, gas chromatography tandem with electron ionization and full‐scan high‐resolution mass spectrometry with a time‐of‐flight mass analyzer was evaluated for analyzing pesticide residues in teas. The relevant aspects for mass spectrometry analysis, including the resolution and mass accuracy, acquisition rate, temperature of ion source, were investigated. Under acquisition condition in 2‐GHz extended dynamic range mode, accurate mass spectral library including 184 gas chromatography detectable pesticides was established and retrieval parameters were optimized. The mass spectra were consistent over a wide concentration range (three orders) with good match values to those of NIST (EI‐quadrupole). The methodology was verified by the validation of 184 pesticides in four tea matrices. A wide linear range (1–1000 μg/kg) was obtained for most compounds in four matrices. Limit of detection, limit of quantification, and limit of identification values acquired in this study could satisfy the requirements for maximum residue levels prescribed by the European Community. Recovery studies were performed at three concentrations (10, 50, and 100 μg/kg). Most of the analytes were recovered at an acceptable range of 70–120% with relative standard deviations ≤ 20% in four matrices. The potential extension of qualitative screening scope makes gas chromatography tandem with electron ionization and mass spectrometry with a time‐of‐flight mass analyzer a more powerful tool compared with gas chromatography with tandem mass spectrometry.  相似文献   

5.
Kaufmann A  Butcher P  Maden K  Walker S  Widmer M 《Talanta》2011,85(2):991-1000
A simple method for the determination of some anthelmintic drugs and phenylbutazone residues in milk and muscle was developed. Following a fast and easy extraction and evaporation procedure, the extract was injected into an ultra performance liquid chromatography system coupled to a single stage Orbitrap detector. The high mass resolution of 50,000 full width at half maximum and corresponding narrow mass windows permitted a very selective and sensitive detection of analytes without requiring fragmentation of the observed [M+H]+ or [M+Na]+ ions. This eliminated some difficulties which have plagued the analysis of compounds belonging to the group of avermectins. The analytical method was validated according to the EU commission decision for Orbitrap based, but also for more traditional tandem mass spectrometry based detection and quantification. Equal repeatability but significantly higher sensitivity for critical compounds (avermectins) was obtained for the Orbitrap based detection. A result of this study was the conclusion that analytes with poor fragmentation properties (e.g. sodium-cationized molecules) can be more easily quantified by single stage high resolution mass spectrometry than by tandem mass spectrometry.  相似文献   

6.
Flunitrazepam (FNZ) is a potent hypnotic, sedative, and amnestic drug used to treat severe insomnia. In our recent study, FNZ metabolic profiles were investigated carefully. Six authentic human urine samples were purified using solid phase extraction (SPE) without enzymatic hydrolysis, and urine extracts were then analyzed by liquid chromatography‐Q exactive‐HF hybrid quadrupole‐Orbitrap‐mass spectrometry (LC‐QE‐HF‐MS), using the full scan positive ion mode and targeted MS/MS (ddms2) technique to make accurate mass measurements. There were 25 metabolites, including 13 phase I and 12 phase II metabolites, which were detected and tentatively identified by LC‐QE‐HF‐MS. In addition, nine previously unreported phase II glucuronide conjugates and four phase I metabolites are reported here for the first time. Eight metabolic pathways, including N‐reduction and O‐reduction, N‐glucuronidation, O‐glucuronidation, mono‐hydroxylation and di‐hydroxylation, demethylation, acetylation, and combinations, were implicated in this work, and 2‐O‐reduction together with dihydroxylation were two novel metabolic pathways for FNZ that were identified tentatively. Although 7‐amino FNZ is widely considered to be the primary metabolite, a previously unreported metabolites (M12) can also serve as a potential biomarker for FNZ misuse.  相似文献   

7.
A multiclass and multiresidue method for screening veterinary drugs and pesticides in infant formula was developed and validated using ultrahigh‐performance liquid chromatography coupled to Quadrupole‐Orbitrap high‐resolution mass spectrometry (UHPLC‐HRMS). A total of 49 veterinary drugs and pesticides investigated belong to 11 classes including antivirals, anticoccidials, macrolides, pyrethroids, insecticides, sulfonamides, beta‐agonists, sedatives, thyreostats, nonsteroidal anti‐inflammatory drugs, and other pharmacologically active substances. A generic sample preparation and highly selective acquisition mode of parallel reaction monitoring (PRM) were deliberately incorporated to perform efficient screening analysis. As a result, the screening target concentrations of the analytes varied from 1 to 500 μg/kg with ≤5% of false compliant rate as specified in Decision 2002/657/EC for screening analysis. The average recoveries ranged from 40.7 to 124.9% as well as the relative standard deviations from 4.2 to 26.6%, respectively. The matrix effects and interferences were effectively controlled by integrated application of dispersive solid phase extraction, PRM scan mode, and matrix‐matched standard calibration. The proposed method will be helpful to provide applicable strategy for screening residues in infant formula with surveillance purpose.  相似文献   

8.
Historically, structural elucidation of unknown analytes by mass spectrometry alone has involved tandem mass spectrometry experiments using electron ionization. Most target molecules for bioanalysis in the metabolome are unsuitable for detection by this previous methodology. Recent publications have used high‐resolution accurate mass analysis using an LTQ‐Orbitrap with the more modern approach of electrospray ionization to identify new metabolites of known metabolic pathways. We have investigated the use of this methodology to build accurate mass fragmentation maps for the structural elucidation of unknown compounds. This has included the development and validation of a novel multi‐dimensional LC/MS/MS methodology to identify known uremic analytes in a clinical hemodialysate sample. Good inter‐ and intra‐day reproducibility of both chromatographic stages with a high degree of mass accuracy and precision was achieved with the multi‐dimensional liquid chromatography/tandem mass spectrometry (LC/MS/MS) system. Fragmentation maps were generated most successfully using collision‐induced dissociation (CID) as, unlike high‐energy CID (HCD), ions formed by this technique could be fragmented further. Structural elucidation is more challenging for large analytes >270 Da and distinguishing between isomers where their initial fragmentation pattern is insufficiently different. For small molecules (<200 Da), where fragmentation data may be obtained without loss of signal intensity, complete structures can be proposed from just the accurate mass fragmentation data. This methodology has led to the discovery of a selection of known uremic analytes and two completely novel moieties with chemical structural assignments made. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
Adulterated products are continuously detected in society and cause problems. In this study, we developed and validated a method for determining synthetic sedative‐hypnotics and sleep inducers, including barbital, benzodiazepam, zolpidem, and first‐generation antihistamines, in adulterated products using Quadrupole‐Orbitrap mass spectrometry and ultrahigh performance liquid chromatography with tandem mass spectrometry. In Quadrupole‐Orbitrap mass spectrometry analysis, target compounds were confirmed using a combination of retention time, mass tolerance, mass accuracy, and fragment ions. For quantification, several validation parameters were employed using ultrahigh performance liquid chromatography with tandem mass spectrometry. The limit of detection and limit of quantitation was 0.05–53 and 0.17–177 ng/mL, respectively. The correlation coefficient for linearity was more than 0.995. The intra‐ and interassay accuracies were 86–110 and 84–111%, respectively. Their precision values were evaluated as within 4.0 (intraday) and 10.7% (interday). Mean recoveries of target compounds in adulterated products ranged from 85 to 116%. The relative standard deviation of stability was less than 10.7% at 4°C for 48 h. The 144 adulterated products obtained over 3 years (2014–2016) from online and in‐person vendors were tested using established methods. After rapidly screening with Quadrupole‐Orbitrap mass spectrometry, the detected samples were quantified using ultrahigh performance liquid chromatography with tandem mass spectrometry. Two of them were adulterated with phenobarbital.  相似文献   

10.
Liquid chromatography coupled to high‐resolution mass spectrometry is the technique of choice for the untargeted profiling of food matrices. Despite the high potential of high‐resolution mass spectrometry, when dealing with complex mixtures, an efficient separation technique is also needed. The novel core‐shell chromatographic columns packed with sub‐2 μm sized particles are claimed to show very good resolution. However, the analytes retention can be significantly altered when working under ultra‐high performance chromatographic conditions. In this work, an evaluation of four chromatographic systems, with either a single or two in‐series Kinetex™ C18 columns, either packed with 2.6 or 1.7 μm particles, is presented for the targeted analysis of a standard mixture and the untargeted analysis of a strawberry extract. An ultra‐high performance chromatographic system coupled via an electrospray source to a hybrid quadrupole‐Orbitrap mass spectrometer was used. From the extensive comparison, a surprising result was obtained, namely, that the system identifying the largest number of features was the one with two in‐series connected columns with the larger particle size. The inconsistency among the theoretical assumptions and the applicative findings points out the importance of an extensive chromatographic evaluation for the comprehensive untargeted profiling of complex real samples.  相似文献   

11.
A smart chemometrics‐assisted strategy that combines the full scan mode of liquid chromatography with mass spectrometry with second‐order calibration method based on alternating trilinear decomposition algorithm was developed for the rapid determination of 15 glucocorticoids including the epimers betamethasone and dexamethasone illegally added into face masks. Fifteen glucocorticoids were rapidly eluted (11 min) under a simple elution program. By means of the second‐order calibration method, 15 target analytes were successfully quantified in the presence of peak overlaps, unknown interferences and baseline drifts. Notably, the epimers, namely, betamethasone and dexamethasone, were simultaneously quantified by the proposed method under a simple elution program. The average spiked recoveries for all target analytes ranged from 87.3 ± 2.2 to 119.4 ± 5.8%. The validation parameters including sensitivity, selectivity, limit of detection, limit of quantitation, and precision were calculated to validate the accuracy of the proposed method, and the quantitative analysis results were further confirmed by liquid chromatography with tandem mass spectrometry. All results proved that the proposed chemometrics‐assisted liquid chromatography with mass spectrometry strategy was an accurate and fast method to determine epimers and multiple glucocorticoids in complex face mask samples.  相似文献   

12.
The sulfonylurea urea drug glyburide (glibenclamide) is widely used for the treatment of diabetes milletus and gestational diabetes. In previous studies monohydroxylated metabolites were identified and characterized for glyburide in different species, but the metabolite owing to the loss of cyclohexyl ring was identified only in mouse. Glyburide upon incubation with hepatic microsomes resulted in 10 metabolites for human. The current study identifies new metabolites of glyburide along with the hydroxylated metabolites that were reported earlier. The newly identified drug metabolites are dihydroxylated metabolites, a metabolite owing to the loss of cyclohexyl ring and one owing to hydroxylation with dehydrogenation. Among the 10 identified metabolites, there were six monohydroxylated metabolites, one dihydroxylated metabolite, two metabolites owing to hydroxylation and dehydrogenation, and one metabolite owing to the loss of cyclohexyl ring. New metabolites of glyburide were identified and characterized using liquid chromatography–diode array detector–quadruple‐ion trap–mass spectrometry/mass spectrometry (LC‐DAD‐Q‐TRAP‐MS/MS). An enhanced mass scan–enhanced product ion scan with information‐dependent acquisition mode in a Q‐TRAP‐MS/MS system was used to characterize the metabolites. Liquid chromatography with diode array detection was used as a complimentary technique to confirm and identify the metabolites. Metabolites formed in higher amounts were detected in both diode array detection and mass spectrometry detection. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

13.
An emerging trend is recognised in hormone and veterinary drug residue analysis from liquid chromatography tandem mass spectrometry (LC/MS/MS) based screening and confirmation towards accurate mass alternatives such as LC coupled with time-of-flight (TOF), Fourier transform ion cyclotron resonance (FTICR) or Fourier transform orbitrap (FT Orbitrap) MS. In this study, mass resolution and accuracy are discussed for LC/MS screening and confirmation of targeted analytes and for the identification of unknowns using the anabolic steroid stanozolol and the designer beta-agonist "Clenbuterol-R" as model substances. It is shown theoretically and experimentally that mass accuracy criteria without proper mass resolution criteria yield false compliant (false negative) results, both in MS screening and MS/MS confirmation of stanozolol. On the other hand, previous medium resolution accurate mass TOFMS/MS data of the designer beta-agonist were fully confirmed by high resolution FT Orbitrap MS(n) experiments. A discussion is initiated through a proposal for additional criteria for the use of accurate mass LC/MS technologies, to be implemented in Commission Decision 2002/657/EC.  相似文献   

14.
Liquid chromatography–(tandem) mass spectrometry [(LC-MS(/MS)] has become an integral part of modern sports drug testing as it offers unique capabilities complementing immunological and gas chromatography–(tandem) mass spectrometry [(GC-MS(/MS)]-based detection methods for prohibited compounds. The improved options of fast and sensitive targeted analysis as well as untargeted screening procedures utilizing high resolution/high accuracy mass spectrometry have considerably expanded the tools available to anti-doping laboratories for initial testing and confirmation methods. One approach is to focus on pre-selected target analytes that are measured with utmost specificity and sensitivity using diagnostic precursor–product ion pairs in low resolution tandem mass spectrometers. The other scenario is to measure and plot extracted ion chromatograms of protonated or deprotonated molecules as well as product ions as recorded in the full scan mode with high resolution/high accuracy mass spectrometry. Examples of recent applications of sports drug testing procedures published between 2007 and 2010 are presented and discussed, outlining the particular advantages of the selected approaches as well as their limitations in a short- and long-term perspective.  相似文献   

15.
The biotoxins, azaspiracids (AZAs), from marine phytoplankton accumulate in shellfish and affect human health by causing severe gastrointestinal disturbance, diarrhea, nausea and vomiting. Specific and sensitive methods have been developed and validated for the determination of the most commonly occurring azaspiracid analogs. An LTQ Orbitrap mass spectrometer is a hybrid instrument that combines linear ion trap (LIT) mass spectrometry (MS) with high‐resolution Fourier transform (FT) MS and this was exploited to perform simultaneous ultra‐high‐resolution full‐scan MS analysis and collision‐induced dissociation (CID) tandem mass spectrometry (MS/MS). Using the highest mass resolution setting (100 000 FWHM) in full‐scan mode, the methodology was validated for the determination of six AZAs in mussel (Mytilus galloprovincialis) tissue extracts. Ultra‐high mass resolution, together with a narrow mass tolerance window of ±2 mDa, dramatically improved detection sensitivity. In addition to employing chromatographic resolution to distinguish between the isomeric azaspiracid analogs, AZA1/AZA6 and AZA4/AZA5, higher energy collisionally induced dissociation (HCD) fragmentation on selected precursor ions were performed in parallel with full‐scan FTMS. Using HCD MS/MS, most precursor and product ion masses were determined within 1 ppm of the theoretical m/z values throughout the mass spectral range and this enhanced the reliability of analyte identity. For the analysis of mussels (M. galloprovincialis), the method limit of quantitation (LOQ) was 0.010 µg/g using full‐scan FTMS and this was comparable with the LOQ (0.007 µg/g) using CID MS/MS. The repeatability data were; intra‐day RSD% (1.8–4.4%; n = 6) and inter‐day RSD% (4.7–8.6%; n = 3). Application of these methods to the analysis of mussels (M. edulis) that were naturally contaminated with azaspiracids, using high‐resolution full‐scan Orbitrap MS and low‐resolution CID MS/MS, produced equivalent quantitative data. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

16.
The quantitative capabilities of a linear ion trap high‐resolution mass spectrometer (LTQ‐Orbitrap™) were investigated using full scan mode bracketing the m/z range of the ions of interest and utilizing a mass resolution (mass/FWHM) of 15000. Extracted ion chromatograms using a mass window of ±5–10 mmu centering on the theoretical m/z of each analyte were generated and used for quantitation. The quantitative performance of the LTQ‐Orbitrap™ was compared with that of a triple quadrupole (API 4000) operating using selected reaction monitoring (SRM) detection. Comparable assay precision, accuracy, linearity and sensitivity were observed for both approaches. The concentrations of actual study samples from 15 Merck drug candidates reported by the two methods were statistically equivalent. Unlike SRM being a tandem mass spectrometric (MS/MS)‐based detection method, a high resolution mass spectrometer operated in full scan does not need MS/MS optimization. This approach not only provides quantitative results for compounds of interest, but also will afford data on other analytes present in the sample. An example of the identification of a major circulating metabolite for a preclinical development study is demonstrated. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

17.
In the present study, we report the application of LC‐MS based on two different LC‐MS systems to mycotoxin analysis. The mycotoxins were extracted with an ACN/water/acetic acid mixture and directly injected into a LC‐MS/MS system without any dilution procedure. First, a sensitive and reliable HPLC‐ESI‐MS/MS method using selected reaction monitoring on a triple quadrupole mass spectrometer (TSQ Quantum Ultra AM) has been developed for determining 32 mycotoxins in crude extracts of wheat and maize. This method was operated both in positive and in negative ionization modes in two separate chromatographic runs. The method was validated by studies of spiked recoveries, linearity, matrix effect, intra‐assay precision and sensitivity. Further, we have developed and evaluated a method based on accurate mass measurements of extracted target ions in full scan mode using micro‐LC‐LTQ‐Orbitrap as a tool for fast quantitative analysis. Both instruments exhibited very high sensitivity and repeatability in positive ionization mode. Coupling of micro‐LC to Orbitrap technology was not applicable to the negatively ionizable compounds. The LC triple quadrupole MS method has proved to be stable in quantitation, as it is with respect to the matrix effects of grain samples.  相似文献   

18.
A rapid and sensitive liquid chromatography with high‐resolution mass spectrometry method with multiple data processing algorithms was developed and applied for the metabolite profiling of evodiamine and its analogous alkaloids in rat plasma after the administration of Wu‐Zhu‐Yu decoction. All samples were purified using hydrophilic‐lipophilic balanced solid‐phase extraction cartridges and analyzed by a Sciex TripleTOF 5600+ mass spectrometer with a 35 min liquid chromatography gradient elution. High‐resolution full‐scan mass spectrometry and information‐dependent acquisition tandem mass spectrometry data were analyzed using multiple data processing approaches. The results indicated that the detected eight prototype alkaloids could be metabolized to 58 metabolites through both phase I and phase II reactions. Oxidation was demonstrated to be the principle metabolic pathway of the parent compounds. The study contributes to the understanding of the absorption and metabolism of the alkaloids in Wu‐Zhu‐Yu decoction and provides a detailed analysis of scientific data.  相似文献   

19.
Toad parotoid gland secretion or toad venom has in recent years been increasingly shown to possess potentially beneficial pharmacological effects; this speculation has drawn much interest centred on elucidating the chemical basis of its multimodal effects. For this purpose, we explored the use of a rapid and accurate analysis method for systemic investigation of the parotoid gland chemistry, when extracted from Australian cane toads. Full‐scan data of cane toad venom extract was acquired using high‐performance liquid chromatography coupled with a hybrid quadrupole–time of flight mass spectrometry system (HPLC/MS‐Q‐TOF), with multiple ionization sources (ESI and APCI) in positive and negative mixed modes. By measuring the exact mass differences between the theoretical and measured mass of each assumed compound, we confirmed the presence of 12 key constituents. The present results demonstrate that the use of HPLC/MS‐Q‐TOF with multiple ionization sources delivers exemplary selectivity and sensitivity, allowing for the rapid and accurate identification of constituents within cane toad venom. This paves the way for this technique to be used in future routine screening of components within the genus Bufo and for key analytes too, then reliably assessed for any purported beneficial (clinic) properties. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

20.
This study describes a method for the screening of methylenedioxyamphetamine‐ and piperazine‐derived compounds in urine by liquid chromatography‐tandem mass spectrometry. These substances, characterized by possessing common moieties, are screened using precursor ion and neutral loss scan mode and then quantified in multiple reaction monitoring acquisition mode. Based on the product‐ion spectra of different known molecules, chosen as ‘model’, characteristic neutral losses and product ions were selected: piperazines were detected in precursor ion scan of m/z 44 and neutral loss of 43 and 86 while amphetamines in precursor ion scan of m/z 133, 135 and 163. The applicability of the screening approach was studied in blank urine spiked with selected analytes and processed by solid‐phase extraction. Linearity, matrix effect, precision, accuracy, limits of detection and limits of quantification were evaluated both for the screening and the quantification methods. The ability of the screening method to provide semi‐quantitative data was demonstrated. This method appears to be a useful tool for the identification of designer drugs derived from piperazines or methylenedioxyamphetamines and can be potentially applied to other drug classes. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号