首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Derivatization of tryptic peptides using an Ettan CAF matrix-assisted laser desorption/ionization (MALDI) sequencing kit in combination with MALDI-post source decay (PSD) is a fast, accurate and convenient way to obtain de novo or confirmative peptide sequencing data. CAF (chemically assisted fragmentation) is based on solid-phase derivatization using a new class of water stable sulfonation agents, which strongly improves PSD analysis and simplifies the interpretation of acquired spectra. The derivatization is performed on solid supports, ZipTip(microC18, limiting the maximum peptide amount to 5 microg. By performing the derivatization in solution enabled the labeling of tryptic peptides derived from 100 microg of protein. To increase the number of peptides that could be sequenced, derivatized peptides were purified using multidimensional liquid chromatography (MDLC) prior to MALDI sequencing. Following the first dimension strong cation exchange (SCX) chromatography step, modified peptides were separated using reversed-phase chromatography (RPC). During the SCX clean up step, positively charged peptides are retained on the column while properly CAF-derivatized peptides (uncharged) are not. A moderately complex tryptic digest, prepared from six different proteins of equimolar amounts, was CAF-derivatized and purified by MDLC. Fractions from the second dimension nano RPC step were automatically sampled and on-line dispensed to MALDI sample plates and analyzed using MALDI mass spectrometry fragmentation techniques. All proteins in the derivatized protein mixture digest were readily identified using MALDI-PSD or MALDI tandem mass spectrometry (MS/MS). More than 40 peptides were unambiguously sequenced, representing a seven-fold increase in the number of sequenced peptides in comparison to when the CAF-derivatized protein mix digest was analyzed directly (no MDLC-separation) using MALDI-PSD. In conclusion, MDLC purification of CAF-derivatized peptides significantly increases the success rate for de novo and confirmative sequencing using various MALDI fragmentation techniques. This new approach is not only applicable to single protein digests but also to more complex digests and could, thus, be an alternative to electrospray ionization MS/MS for peptide sequencing.  相似文献   

2.
In this study, the advantages of carrying out the analysis of peptides and tryptic digests of proteins under gradient elution conditions at pH 6.5 by reversed-phase liquid chromatography (RP-HPLC) and in-line electrospray ionisation mass spectrometry (ESI-MS) are documented. For these RP separations, a double endcapped, bidentate anchored n-octadecyl wide pore silica adsorbent was employed in a capillary column format. Compared to the corresponding analysis of the same peptides and protein tryptic digests using low pH elution conditions for their RP-HPLC separation, this alternative approach provides improved selectivity and more efficient separation of these analytes, thus allowing a more sensitive identification of proteins at different abundance levels, i.e. more tryptic peptides from the same protein could be confidently identified, enabling higher sequence coverage of the protein to be obtained. This approach was further evaluated with very complex tryptic digests derived from a human plasma protein sample using an online two-dimensional (2D) strong cation-exchange (SCX)-RP-HPLC-ESI-MS/MS system. Again, at pH 6.5, with mobile phases of different compositions, improved chromatographic selectivities were obtained, concomitant with more sensitive on-line electrospray ionisation tandem mass spectrometric (ESI-MS/MS) analysis. As a consequence, more plasma proteins could be confidently identified, highlighting the potential of these RP-HPLC methods with elution at pH 6.5 to extend further the scope of proteomic investigations.  相似文献   

3.
As the serum peptidome gets increasing attention for biomarker discovery, one of the important issues is how to efficiently extract the peptides from highly complex human serum for peptidome analysis. Here we developed a fully automated platform for direct injection, on-line extraction, multidimensional separation and MS detection of peptides present in human serum. A capillary SPE column packed with a novel mix mode restricted access material (RAM) exhibiting strong cation exchange and size exclusion chromatography (SCX/SEC) properties were coupled with a nanoliquid chromatography–mass spectrometry (nanoLC-MS) system. The capillary SPE column excludes the high abundant serum proteins such as HSA by size exclusion chromatography and simultaneously extracts the low molecular weight peptides by binding to sulfonic acid residues. Subsequently, the trapped peptides are eluted to a capillary LC column packed with a RP-C18 stationary phase. After injection of only 2 μL human serum to the one-dimensional nanoLC-MS system around 400 peptides could be identified. When conducting a multidimensional separation, the described SCX/SEC/RP-MS platform allows the separation and identification of 1286 peptides present in human serum by the injection and on-line processing of 20 μL human serum sample.  相似文献   

4.
Luo Q  Gu Y  Wu SL  Rejtar T  Karger BL 《Electrophoresis》2008,29(8):1604-1611
This study expands the capabilities for ultratrace proteomic analysis of our previous work by incorporating on-line sample desalting using a triphasic (RP/strong cation exchange (SCX)/micro-SPE) trapping column connected to a 3.2 m x 10 microm id poly(styrene-divinylbenzene) (PS-DVB) porous layer open tubular (PLOT) column. To minimize extra sample handling steps, C18 RP packing was incorporated in the capillary tubing upstream of the SCX column for the on-line desalting. For the micro-SPE column, a 50 microm id PS-DVB monolithic column was positioned downstream of the SCX column. High-performance separation was achieved on the PLOT column at a mobile phase flow rate of 20 nL/min. The sensitivity and high resolution capability of the new multidimensional platform was evaluated using an in-gel tryptic digested sample of a cervical cancer (SiHa) cell line. For the injected amount of 1200 cells ( approximately 500 ng), over 2700 peptides covering greater than 850 unique proteins were identified from the triphasic SCX/PLOT/MS analysis of a single SDS gel section (>40 kDa). The 2-D LC/MS platform demonstrated good separation performance, such that more than 85% of the identified peptides were detected from only one salt fraction. In a triplicate analysis of the above >40 kDa gel section, 4497 peptides and 1209 unique proteins were identified when applying stringent filtering criteria, with a false-positive rate of 2.4%. When all three SDS-PAGE gel sections of the lysed SiHa cells were analyzed, 5047 peptides and 1857 unique proteins (false-positive rate 1.8%), including cancer-related proteins such as MAP kinases, were identified.  相似文献   

5.
Comprehensive proteomic analyses necessitate efficient separation of peptide mixtures for the subsequent identification of proteins by mass spectrometry (MS). However, digestion of proteins extracted from cells and tissues often yields complex peptide mixtures that confound direct comprehensive MS analysis. This study investigated a zwitterionic hydrophilic interaction liquid chromatography (ZIC‐HILIC) technique for the peptide separation step, which was verified by subsequent MS analysis. Human serum albumin (HSA) was the model protein used for this analysis. HSA was digested with trypsin and resolved by ZIC‐HILIC or conventional strong cation exchange (SCX) prior to MS analysis for peptide identification. Separation with ZIC‐HILIC significantly improved the identification of HSA peptides over SCX chromatography. Detailed analyses of the identified peptides revealed that the ZIC‐HILIC has better peptide fractionation ability. We further demonstrated that ZIC‐HILIC is useful for quantitatively surveying cell surface markers specifically expressed in undifferentiated embryonic stem cells. These results suggested the value of ZIC‐HILIC as a novel and efficient separation method for comprehensive and quantitative proteomic analyses. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

6.
A two-dimensional capillary array liquid chromatography system coupled with matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) was developed for high-throughput comprehensive proteomic analysis, in which one strong cation-exchange (SCX) capillary chromatographic column was used as the first separation dimension and 10 parallel reversed-phase liquid chromatographic (RPLC) capillary columns were used as the second separation dimension. A novel multi-channel interface was designed and fabricated for on-line coupling of the SCX to RPLC column array system. Besides the high resolution based on the combination of SCX and RPLC separation, the developed new system provided the most rapid two-dimensional liquid chromatography (2D-LC) separation. Ten three-way micro-splitter valves used as stop-and-flow switches in transferring SCX fractions onto RPLC columns. In addition, the three-way valves also acted as mixing chambers of RPLC effluent with matrix. The system enables on-line mixing of the LC array effluents with matrix solution during the elution and directly depositing the analyte/matrix mixtures on MALDI plates from the tenplexed channels in parallel through an array of capillary tips. With the novel system, thousands of peptides were well separated and deposited on MALDI plates only in 150min for a complex proteome sample. Compared with common 2D-LC system, the parallel 2D-LC system showed about 10-times faster analytical procedure. In combination with a high throughput tandem time of flight mass spectrometry, the system was proven to be very effective for proteome analysis by analyzing a complicated sample, soluble proteins extracted from a liver cancer tissue, in which over 1202 proteins were identified.  相似文献   

7.
It was the aim of this study to compare the performance of displacement chromatography with gradient elution chromatography both applied as the cation-exchange separation step for a proteome analysis in a bottom-up approach using multidimensional chromatography for the separation of tryptic peptides prior to their mass spectrometric analysis. The tryptic digest of the human Cohn fraction IV-4 served as a sample. For both chromatography modes commonly used operating parameters were chosen thus ensuring optimal separation results of equal sample amounts for each mode. All resulting fractions were analyzed with an HPLC-chip–LC–MS system. The eluate of the HPLC-chip column was ionized by electrospray ionization (ESI) and analyzed with an ion-trap mass spectrometer. For guaranteeing high confidence concerning the identity of the peptides, the mass spectrometric data were processed by different bioinformatic tools applying stringent criteria. By the displacement approach the total amount of identified proteins (78) was significantly higher than in the gradient mode (58). The results showed that displacement chromatography is a well suited alternative in comparison to gradient elution separation for analysis of proteomes via the bottom-up approach applying multidimensional chromatography, especially in those cases when larger quantities of proteins are available.  相似文献   

8.
A mixed-mode chromatographic (MMC) sorbent was prepared by functionalizing the silica sorbent with a pentafluorophenyl (PFP) ligand. The resulting stationary phase provided a reversed-phase (RP) retention mode along with a relatively mild strong cation-exchange (SCX) retention interaction. While the mechanism of interaction is not entirely clear, it is believed that the silanols in the vicinity of the perfluorinated ligand act as strongly acidic sites. The 2.1 mm x 150 mm column packed with such sorbent was applied to the separation of peptides. Linear RP gradients in combination with salt steps were used for pseudo two-dimensional (2D) separation and fractionation of tryptic peptides. An alternative approach of using linear cation-exchange gradients combined with RP step gradients was also investigated. Besides the attractive forces, the ionic repulsion contributed to the retention mechanism. The analytes with strong negatively charged sites (phosphorylated peptides, sialylated glycopeptides) eluted in significantly different patterns than generic tryptic peptides. This retention mechanism was employed for the isolation of phosphopeptides or sialylated glycopeptides from non-functionalized peptide mixtures. The mixed-mode column was utilized in conjunction with a phosphopeptide enrichment solid phase extraction (SPE) device packed with metal oxide affinity chromatography (MOAC) sorbent. The combination of MOAC and mixed-mode chromatography (MMC) provided for an enhanced extraction selectivity of phosphopeptides and sialylated glycopeptides peptides from complex samples, such as yeast and human serum tryptic digests.  相似文献   

9.
为了在短时间内获得相对含量高的磷酸化肽段,以标准磷酸化蛋白质为模型对强阳离子交换色谱(SCX)分离磷酸化肽段体系的缓冲溶液和梯度设置进行了研究,并用酵母酶切肽段混合物考察了该路线在较复杂的样品中的应用。实验结果表明优化后的体系能够在30 min内分离出磷酸肽段,而且非磷酸化肽段的干扰很少,这样便相对提高了磷酸化肽段在质谱仪中的响应强度,重要的是该体系可以对复杂样品进行很好的分离。这说明SCX用于规模化磷酸化肽段富集的策略是可行的。本研究为磷酸化蛋白质组学规模化分析提供了实用技术。  相似文献   

10.
In proteomics, nanoflow multidimensional chromatography is now the gold standard for the separation of complex mixtures of peptides as generated by in-solution digestion of whole-cell lysates. Ideally, the different stationary phases used in multidimensional chromatography should provide orthogonal separation characteristics. For this reason, the combination of strong cation exchange chromatography (SCX) and reversed-phase (RP) chromatography is the most widely used combination for the separation of peptides. Here, we review the potential of hydrophilic interaction liquid chromatography (HILIC) as a separation tool in the multidimensional separation of peptides in proteomics applications. Recent work has revealed that HILIC may provide an excellent alternative to SCX, possessing several advantages in the area of separation power and targeted analysis of protein post-translational modifications. Figure Artistic impression of the HILIC separation mechanism  相似文献   

11.
An online two-dimensional (2D) strong cation-exchange (SCX)/reversed-phase (RP) nano-scale liquid chromatography/mass spectrometry (nanoLC/MS) method was developed for improved separation and hydrophobic peptide recovery. Sharper and more symmetric RP peaks were observed with the use of a "band re-focusing method", in which an analytical RP column with more hydrophobicity than the RP trap column was used in the system. To recover hydrophobic peptides still unreleased from the SCX column after a conventional salt step gradient due to hydrophobic interaction, a RP step gradient from 10% to 30% acetonitrile (ACN) was applied to the SCX column in the presence of a high salt concentration following the salt gradient. There were 301 unique hydrophobic E. coli peptides identified from the RP fractions. These peptides, which were 19% of all E. coli peptides identified from a 2D run, would not have been identified without the application of the RP gradient to the SCX column.  相似文献   

12.
This work illustrates the practical use of combined microbore reversed-phase high-performance liquid chromatography (RP-HPLC) with electrospray ionization mass spectrometry (ESI-MS) in protein identification. The approach consisted of the detection of the abnormal beta-globin chain by ESI-MS analysis of mixtures of intact globins, which simultaneously provided their molecular masses. Separation of the polypeptide globin chains was carried out using microbore C4 RP-HPLC on-line with ESI-MS. Direct peptide-mapping ESI-MS without previous chromatographic separation was performed in order to identify tryptic peptides from whole blood. For the sequence confirmation of the abnormal peptide containing the mutation point, C18 RP-HPLC tryptic separation of the globin mixture on-line with collision-induced dissociation (CID) fragmentation was done. The y series ions allowed the identification of the hemoglobin (Hb) variant as [beta134(H12) Val > Ala]. This new Hb was named Hb Mataró, after the city where it was detected.  相似文献   

13.
Zhang Z  Wang J  Hui L  Li L 《Electrophoresis》2012,33(4):661-665
Herein, we report an immobilized pH gradient (IPG) capillary isoelectric focusing-matrix-assisted laser desorption/ionization mass spectrometry (CIEF-MALDI MS) platform designed for the separation of complex neuropeptides. This platform features a poly(glycidyl methacrylate-divinylbenzene) (GMA-DVB)-based monolithic column for CIEF separation. Different from regular CIEF, carrier ampholytes are preimmobilized on the monolithic surface instead of being added to the sample. An off-line coupling of IPG-CIEF to MALDI MS has been established. Comparison with regular CIEF and optimizations are performed with bovine serum albumin tryptic peptides and extracted neuropeptide mixtures from crustacean Callinectes sapidus. It has been demonstrated that the separation of complex peptide mixtures in neutral and basic pH ranges can be achieved in less than 10 min with comparable separation efficiency with regular CIEF, while the MS signal is significantly enhanced when employing IPG-CIEF. Enhanced neuropeptide detection is also observed after coupling IPG-CIEF with MALDI MS.  相似文献   

14.
Capillary high-performance liquid chromatography has been coupled on-line with an ion trap storage/reflectron time-of-flight mass spectrometer to perform tandem mass spectrometry for tryptic peptides. Selection and fragmentation of the precursor ions were performed in a three-dimensional ion trap, and the resulting fragment ions were pulsed out of the trap into a reflectron time-of-flight mass spectrometer for mass analysis. The stored waveform inverse Fourier transform waveform was applied to perform ion selection and an improved tickle voltage optimization scheme was used to generate collision-induced dissociation. Tandem mass spectra of various doubly charged tryptic peptides were investigated where a conspicuous y ion series over a certain mass range defined a partial amino acid sequence. The partial sequence was used to determine the identity of the peptide or even the protein by database search using the sequence tag approach. Several peptides from tryptic digests of horse heart myoglobin and bovine cytochrome c were selected for tandem mass spectrometry (MS/MS) where it was demonstrated that the proteins could be identified based on sequence tags derived from MS/MS spectra. This approach was also utilized to identify protein spots from a two-dimensional gel separation of a human esophageal adenocarcinoma cell line.  相似文献   

15.
A dual-purpose sample-trapping column is introduced for the capacity enhancement of proteome analysis in on-line two-dimensional nanoflow liquid chromatography (strong cation-exchange chromatography followed by reversed-phase liquid chromatography) and tandem mass spectrometry. A home-made dual trap is prepared by sequentially packing C18 reversed-phase (RP) particles and SCX resin in a silica capillary tubing (1.5 cm x 200 microm I.D. for SCX, 0.7 cm x 200 microm for RP) ended with a home-made frit and is connected to a nanoflow column having a pulled tip treated with an end frit. Without having a separate fraction collection and concentration process, digested peptide mixtures were loaded directly in the SCX part of the dual trap, and the SCX separation of peptides was performed with a salt step elution initiated by injecting only 8 microL of NH4HCO3 solution from the autosampler to the dual trap. The fractionated peptides at each salt step were directly transferred to the RP trap packed right next to the SCX part for desalting, and a nanoflow LC-MS-MS run was followed. During the sample loading-SCX fractionation-desalting, flow direction was set to bypass the analytical column to prevent contamination. The entire 2D-LC separation and MS-MS analysis were automated. Evaluation of the technique was made with an injection of 15 microg peptide mixtures from human Jurkat T-cell proteome, and the total seven salt step cycles followed by each RPLC run resulted in an identification of 681 proteins.  相似文献   

16.
High-efficiency peptide analysis using multimode pressure-assisted capillary electrochromatography/capillary electrophoresis (pCEC/pCE) monolithic polymeric columns and the separation of model peptide mixtures and protein digests by isocratic and gradient elution under an applied electric field with UV and electrospray ionization-mass spectrometry (ESI-MS) detection is demonstrated. Capillary multipurpose columns were prepared in silanized fused-silica capillaries of 50, 75, and 100 microm inner diameters by thermally induced in situ copolymerization of methacrylic monomers in the presence of n-propanol and formamide as porogens and azobisisobutyronitrile as initiator. N-Ethylbutylamine was used to modify the chromatographic surface of the monolith from neutral to cationic. Monolithic columns were termed as multipurpose or multimode columns because they showed mixed modes of separation mechanisms under different conditions. Anion-exchange separation ability in the liquid chromatography (LC) mode can be determined by the cationic chromatographic surface of the monolith. At acidic pH and high voltage across the column, the monolithic stationary phase provided conditions for predominantly capillary electrophoretic migration of peptides. At basic pH and electric field across the column, enhanced chromatographic retention of peptides on monolithic capillary column made CEC mechanisms of migration responsible for separation. The role of pressure, ionic strength, pH, and organic content of the mobile phase on chromatographic performance was investigated. High efficiencies (exceeding 300 000 plates/m) of the monolithic columns for peptide separations are shown using volatile and nonvolatile, acidic and basic buffers. Good reproducibility and robustness of isocratic and gradient elution pressure-assisted CEC/CE separations were achieved for both UV and ESI-MS detection. Manipulation of the electric field and gradient conditions allowed high-throughput analysis of complex peptide mixtures. A simple design of sheathless electrospray emitter provided effective and robust low dead volume interfacing of monolithic multimode columns with ESI-MS. Gradient elution pressure-assisted mixed-mode separation CE/CEC-ESI-MS mass fingerprinting and data-dependent pCE/pCEC-ESI-MS/MS analysis of a bovine serum albumin (BSA) tryptic digest in less than 5 min yielding high sequence coverage (73%) demonstrated the potential of the method.  相似文献   

17.
We have revised current two-dimensional RP-RP approaches and developed a new robust 2-D RP-RP platform. This platform was implemented on an Agilent 1100 2-D liquid chromatography system and is based on high pressure switching between two high-resolution RP columns. An independent binary gradient was implemented for each dimension. The powerful combination of dual analytical columns with independent gradient elution achieves high analyte purity, effectively eliminates matrix effects, and maximizes MS sensitivity in Q1 SIM comparable to the sensitivity enhancements of MS/MS-based methods. Implementation of dual simultaneous gradient profiles (overlapped gradients) reduces 2-D method run-time to the scale of 1-D method run-times. This robust and sensitive approach is particularly suitable for hydrophobic peptides and small proteins and can be used as a routine standard technique for enhanced on-line peptide purification coupled with mass spectrometric detection.  相似文献   

18.
The identification of hemoglobin (Hb) variants is usually performed by means of different analytical steps and methodologies. Phenotypic methods, such as gel electrophoresis and high performance liquid chromatography, are used to detect the different electrophoretic or chromatographic behaviors of hemoglobin variants in comparison to HbA0 used as a control. These data often need to be combined with mass spectrometry analyses of intact globins and their tryptic peptide mixtures. As an alternative to a 'step-by-step' procedure, we have developed a 'single step' approach for the identification of Hb variants present in biological samples. This is based on the microHPLC-ESI-MS/MS analysis of the peptide mixture generated by a tryptic digestion of diluted Hb samples and an in-house new database containing solely the variant tryptic peptide of known human Hb variants. The experimental results (full MS and MS/MS spectra) are correlated with theoretical mass spectra generated from our in-house-built variant peptide database (Hbp) using the SEQUEST algorithm. Simple preparation of samples and an automated identification of the variant peptide are the main characteristics of this approach, making it an attractive method for the detection of Hb variants at the routine clinical level. We have analyzed 16 different samples, each containing a different known variant of hemoglobin.  相似文献   

19.
In high-throughput proteomics, the bottom-up approach has become a widely used method for the identification of proteins that is based on tryptic peptide MS/MS analysis. Separation methodologies that use IEF of tryptic peptides have recently been introduced and provide an extra dimension of peptide separation. In addition to its great fractionation capability, tryptic peptide prefractionation by IEF can also increase the protein identification success. The pI information of the peptide gained can be successfully used in a post-database search filtering step. We introduce a filtering algorithm that is based on the comparison of the experimental and theoretical pI's to validate peptide identifications by MS/MS data search engines.  相似文献   

20.
构建了以阳离子交换色谱-反相色谱(SCX-RPLC)为分离模式的新型全二维微柱液相色谱-质谱分离平台.采用了醋酸铵缓冲液梯度洗脱,实现了第一维肽段的分步洗脱,洗脱的肽段经富集除盐后通过接口进入反相色谱微柱,通过线性梯度实现第二维进一步分离,最后进入质谱进行检测.采用此平台分析了人胃癌组织与正常组织提取蛋白质信息,其中正常胃组织鉴定蛋白质数为537个,而癌症组织鉴定蛋白质数目为506个.对胃癌和正常组织两种提取蛋白质酶解产物的蛋白质检索结果进行比较分析,将鉴定的蛋白质按照物理性质进行分布,找出正常组织与癌症组织间蛋白质差异,筛选出一种可能发生变异的癌症特有蛋白.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号