首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A comparison of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography for the separation of synthetic cathinones has been conducted. Nine different mixtures of bath salts were analyzed in this study. The three different chromatographic techniques were examined using a general set of controlled synthetic cathinones as well as a variety of other synthetic cathinones that exist as positional isomers. Overall 35 different synthetic cathinones were analyzed. A variety of column types and chromatographic modes were examined for developing each separation. For the ultra high performance supercritical fluid chromatography separations, analyses were performed using a series of Torus and Trefoil columns with either ammonium formate or ammonium hydroxide as additives, and methanol, ethanol or isopropanol organic solvents as modifiers. Ultra high performance liquid chromatographic separations were performed in both reversed phase and hydrophilic interaction chromatographic modes using SPP C18 and SPP HILIC columns. Gas chromatography separations were performed using an Elite‐5MS capillary column. The orthogonality of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography was examined using principal component analysis. For the best overall separation of synthetic cathinones, the use of ultra high performance supercritical fluid chromatography in combination with gas chromatography is recommended.  相似文献   

2.
By combining separation efficiency data as a function of flow rate with the column permeability, the kinetic plot method allows to determine the limits of separation power (time vs. efficiency) of different chromatographic techniques and methods. The technique can be applied for all different types of chromatography (liquid, gas, or supercritical fluid), for different types of column morphologies (packed beds, monoliths, open tubular, micromachined columns), for pressure and electro‐driven separations and in both isocratic and gradient elution mode. The present contribution gives an overview of the methods and calculations required to correctly determine these kinetic performance limits and their underlying limitations.  相似文献   

3.
Citicoline and piracetam were subjected separately to different stress conditions as recommended by the international conference on harmonization. In addition, new stability indicating thin layer chromatographic and ultra high performance liquid chromatographic methods have been developed and validated for simultaneous determination of citicoline and piracetam in presence of their degradation products. Separation on the proposed thin layer chromatographic method was carried out using a developing system containing methanol:chloroform:ammonium chloride buffer (9:1:2, v/v/v) on silica gel plates at 230 nm. On the other hand, the mobile phase in the ultra high performance liquid chromatographic method was composed of water (containing 0.1% triethylamine):ethanol (92:8, v/v). The flow rate was 1 mL/min and ultraviolet detection was at 230 nm. Moreover, results of the developed methods were statistically compared to those obtained by the reported high‐performance liquid chromatography method and no significant difference between them was found. The greenness profile of ultra high performance liquid chromatographic method was assessed and compared with those of the previously published high‐performance liquid chromatography methods, it was noticed that the proposed ultra high performance liquid chromatographic method more environmentally friendly and greener than other methods.  相似文献   

4.
Ultra high performance liquid chromatography and supercritical fluid chromatography techniques are favored because of their high efficiency and fast analysis speed. Although many sample preparation techniques have been coupled with common liquid chromatography online, the online coupling of sample preparation with the two popular chromatography techniques have gained increasing attention owing to the increasing requirements of efficiency and sensitivity. In this review, we have discussed and summarized the recent advances of the online coupling of sample preparation with ultra high performance liquid chromatography and supercritical fluid chromatography techniques. The main sample preparation techniques that have been coupled with ultra high performance liquid chromatography online are solid‐phase extraction and in‐tube solid‐phase microextraction, while solid‐phase extraction and supercritical fluid extraction are the main techniques that have been coupled with supercritical fluid chromatography online. Especially, the strategies for online coupling of sample preparation with chromatography techniques were summarized. Typical applications and growing trends of the online coupling techniques were also discussed in detail. With the increasing demands of improving the efficiency, throughput, and analytical capability toward complex samples of the analysis methods, online coupling of sample preparation with chromatography techniques will acquire further development.  相似文献   

5.
The separation of enantiomers by chromatographic methods, such as gas chromatography, high‐performance liquid chromatography and capillary electrochromatography, has become an increasingly significant challenge over the past few decades due to the demand of pharmaceutical, agrochemical, and food analysis. Among these chromatographic resolution methods, high‐performance liquid chromatography based on chiral stationary phases has become the most popular and effective method used for the analytical and preparative separation of optically active compounds. This review mainly focuses on the recent development trends for novel chiral stationary phases based on chitosan derivatives, cyclofructan derivatives, and chiral porous materials that include metal‐organic frameworks and covalent organic frameworks in high‐performance liquid chromatography. The enantioseparation performance and chiral recognition mechanisms of these newly developed chiral selectors toward enantiomers are discussed in detail.  相似文献   

6.
A new analytical method for multiresidue determination of 16 multiclass pesticides in lettuce was developed using ultra‐high performance liquid chromatography with tandem mass spectrometry with a triple quadrupole mass analyzer and positive mode electrospray ionization, using a previously optimized quick, easy, cheap, effective, rugged, and safe method for sample preparation. Validation studies, according to document SANTE/11945/2015, demonstrated that the developed method is selective, accurate, and precise, providing recoveries of 70–120%, relative standard deviations ≤20% and quantification limits from 3 μg/kg. The method was compared with one based on high‐performance liquid chromatography with tandem mass spectrometry, in terms of chromatographic performance, detectability and matrix effect for five varieties of lettuce. The new method provided a reduction in the time for the chromatographic analysis of 50%, from 30 to 15 min, using a lower mobile phase flow rate (0.147 mL/min), which reduced the consumption of mobile phase by 25%, and injection of smaller amounts of sample (1.7 μL). Lower limits of quantification were obtained for almost all pesticides studied for green‐leaf lettuce. However, in relation to the matrix effect, four of the five types of lettuce studied presented higher matrix effects.  相似文献   

7.
The newest results in the employment of carbon‐based composites in various chromatographic techniques such as gas–liquid chromatography, high‐performance liquid chromatography and electrically driven separation techniques for the separation, quantitative determination and identification of a wide variety of compounds in complicated matrices are compiled. The results are concisely described and critically evaluated. The future trends in the application of carbon‐based compounds in the chromatographic separation methods are briefly discussed. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

8.
戴朝政  徐小平 《色谱》2020,38(5):581-586
研究了色谱分离过程中物质的径向扩散和流动相发热对柱效能的影响。从热传导方程出发,运用色谱过程动力学原理推导了包括考虑流动相径向扩散、色谱柱发热影响的液相色谱塔板高度方程:

该方程概括了高效液相色谱(HPLC)、超高效液相色谱(UPLC)、毛细管电色谱(CEC)和消滞留层液相色谱(ESFLC)塔板高度与各种因素的关系。方程最后一项代表了径向扩散和柱发热对塔板高度的贡献。当流动相线速度较低且柱内径较细时,流动相摩擦生热和径向扩散对塔板高度的贡献趋近于零,塔板高度方程还原成Horvath和Lin的方程;当流动相线速度较高时,由于流动相摩擦生热,柱轴心与边缘温差增加,导致流动相线速度径向分布差异,使得柱效率降低。柱轴心与边缘的温差与流动相线速度平方成正比。该文指出,在流动相高线速度情况下,液相色谱的柱效率与柱内径密切相关,采用细内径柱有利于实现高速与高效率;过高的流动相线速度将导致色谱柱效率崩溃。  相似文献   

9.
在纤维素-三-(3,5-二甲基苯基氨基甲酸酯)(Chiralcel OD-H)手性柱上对硅氟唑对映体的分离进行了研究.考察了流动相中改性剂的种类和浓度、流速以及柱温对分离效果的影响,并对手性拆分机制进行了讨论.实验结果表明:5种醇改性剂中,异丙醇的改性效果最佳,当异丙醇含量为2%时,分离度(Rs)达最大值10.19;在...  相似文献   

10.
A new capillary high‐performance liquid chromatography method with atmospheric pressure chemical ionization mass spectrometry was developed for the analysis of fatty acid methyl esters and long‐chain alcohols. The chromatographic separation was achieved using a Zorbax SB‐C18 HPLC column (0.3 × 150 mm, 3.5 μm) with a mobile phase composed of acetonitrile and formic acid and delivered isocratically at a flow rate of 10 μL/min. The column temperature was programmed simply, using a common column oven. Good reproducibility of the temperature profile and retention times were achieved. The temperature programming during the isocratic high‐performance liquid chromatography run had a similar effect as a solvent gradient; it reduced retention times of later eluting analytes and improved their detection limits. Two atmospheric pressure chemical ionization sources of the mass spectrometry detector were compared: an enclosed conventional ion source and an in‐house made ion source with a glass microchip nebulizer. The enclosed source provided better detectability of saturated fatty acid methyl esters and made it possible to determine the double bond positions using acetonitrile‐related adducts, while the open chip‐based source provided better analytical figures of merit for unsaturated fatty acid methyl esters. Temperature‐programmed capillary high‐performance liquid chromatography is a promising method for analyzing neutral lipids in lipidomics and other applications.  相似文献   

11.
快速高效液相色谱分离技术在中药分析中的应用   总被引:3,自引:0,他引:3  
刘颖  周建良  李萍 《色谱》2009,27(5):682-689
中药化学成分分析是中药药效物质阐明及质量控制的关键问题之一。由于中药化学成分的复杂性,中药成分分析一直存在着分离难度大、分析时间长等问题。为此,针对这些问题发展起来的快速、高效液相色谱技术(主要包括超高压液相色谱、基于整体柱的高效液相色谱和高温液相色谱)备受关注。本文结合本实验室近年的研究,对该技术在中药复杂体系化学成分分析中的应用做简要综述,内容主要包括这些技术的原理、分离性能及其在中药复杂体系中的应用。  相似文献   

12.
Low‐temperature high‐performance liquid chromatography, in which a loop injector, column, and detection cell were refrigerated at –35ºC, using liquid carbon dioxide as the mobile phase was developed. Small organic compounds (polyaromatic hydrocarbons, alkylbenzenes, and quinones) were separated by low‐temperature high‐performance liquid chromatography at temperatures from –35 to –5ºC. The combination of liquid carbon dioxide mobile phase with an octadecyl‐silica (C18) column provided reversed phase mode separation, and a bare silica‐gel column resulted in normal phase mode separation. In both the cases, nonlinear behavior at approximately –15ºC was found in the relationship between the temperature and the retention factors of the analytes (van't Hoff plots). In contrast to general trends in high‐performance liquid chromatography, the decrease in temperature enhanced the separation efficiency of both the columns.  相似文献   

13.
New, pharmacologically interesting chiral amino compounds, namely, stereoisomers of α‐hydroxynaphthyl‐ß‐carboline, benz[d]azepine and benz[c]azepine analogs as well as N‐α‐hydroxynaphthylbenzyl‐substituted isoquinolines were enantioseparated by high‐performance liquid chromatographic and subcritical fluid chromatographic methods on polysaccharide‐based chiral stationary phases. Separation of the stereoisomers was optimized in both subcritical fluid chromatography and normal phase liquid chromatographic modes by investigating the effects of the composition of the bulk solvent, temperature, and the structures of the analytes and selectors. Both normal phase liquid chromatography and subcritical fluid chromatography exhibited satisfactory performance, albeit with somewhat different effectiveness in the separation of the stereoisomers studied. The optimized methods offer the possibility to apply preparative‐scale separations thereby enabling further pharmacological investigations of the enantiomers.  相似文献   

14.
The newest achievements in the application of miscellaneous liquid chromatographic techniques such as size-exclusion, ion-exchange and reversed-phase high-performance liquid chromatography, and thin-layer chromatography for the elucidation of the various aspects of the binding of ligands to proteins are compiled and briefly discussed. Examples of employment in pharmaceutical and clinical chemistry, drug design, enzyme kinetic studies and environmental protection are presented.  相似文献   

15.
高效制备液相色谱柱技术的研究进展   总被引:16,自引:0,他引:16  
李瑞萍  黄骏雄 《化学进展》2004,16(2):273-283
本文概述了高效制备液相色谱柱的柱型结构、填料以及柱填充方法等研究的最新进展,讨论了制备柱与分析柱的不同特征,对目前普遍使用的压缩型制备柱的类型、结构及填充方法作了较为全面的评述,总结比较了工业化制备色谱填料不同于分析色谱填料的特点,探讨了高效制备液相色谱柱技术的应用和发展前景.  相似文献   

16.
Off‐line comprehensive two‐dimensional reversed‐phase countercurrent chromatography with high‐performance liquid chromatography was investigated in separation of crude ethanol extract from traditional Chinese medicinal herb Polygonum cuspidatum Sieb. et Zucc. Two‐dimensional contour plots for countercurrent chromatography with high‐performance liquid chromatography was obtained after comprehensive separation was completed. Total peak capacity was evaluated and approximately 810 peaks were obtained through a comprehensive two‐dimensional separation. A highly orthogonality of 52.23% and a large separation space occupancy of 88.86% were achieved. Meanwhile, it was found that several components could be well separated by countercurrent chromatography while they could not be separated by high‐performance liquid chromatography, and vice versa, which further indicated the orthogonality of the two separation methods. The off‐line comprehensive two‐dimensional countercurrent chromatography with high‐performance liquid chromatography provided a promising and powerful method for separation of complex natural products.  相似文献   

17.
An ionic liquid was incorporated into the porous polymer monoliths to afford stationary phases with enhanced chromatographic performance for small molecules in reversed‐phase high‐performance liquid chromatography. The effect of the ionic liquid in the polymerization mixture on the performance of the monoliths was studied in detail. While monoliths without ionic liquid exhibited poor resolution and low efficiency, the addition of ionic liquid to the polymerization mixture provides highly increased resolution and high efficiency. The chromatographic performances of the monoliths were demonstrated by the separations of various small molecules including aromatic hydrocarbons, isomers, and homologues using a binary polar mobile phase. The present column efficiency reached 27 000 plates/m, which showed that the ionic liquid monoliths are alternative stationary phases in the separation of small molecules by high‐performance liquid chromatography  相似文献   

18.
In this study, complex substances such as Mint (Mentha haplocalyx Briq.) samples from different growing regions in China were analyzed for phenolic compounds by high‐performance liquid chromatography with diode array detection and for the volatile aroma compounds by gas chromatography with mass spectrometry. Chemometrics methods, e.g. principal component analysis, back‐propagation artificial neural networks, and partial least squares discriminant analysis, were applied to resolve complex chromatographic profiles of Mint samples. A total of 49 aroma components and 23 phenolic compounds were identified in 79 Mint samples. Principal component analysis score plots from gas chromatography with mass spectrometry and high‐performance liquid chromatography with diode array detection data sets showed a clear distinction among Mint from three different regions in China. Classification results showed that satisfactory performance of prediction ability for back‐propagation artificial neural networks and partial least squares discriminant analysis. The major compounds that contributed to the discrimination were chlorogenic acid, unknown 3, kaempherol 7‐O‐rutinoside, salvianolic acid L, hesperidin, diosmetin, unknown 6 and pebrellin in Mint according to regression coefficients of the partial least squares discriminant analysis model. This study indicated that the proposed strategy could provide a simple and rapid technique to distinguish clearly complex profiles from samples such as Mint.  相似文献   

19.
A rapid and sensitive ultra high performance liquid chromatography method with diode array detection was developed for the fingerprint analysis and simultaneous determination of seven active compounds in Xiaoyanlidan (XYLD) tablets. The chromatographic separations were obtained on an Agilent Eclipse plus C18 column (50 × 2.1 mm id, 1.8 μm) using gradient elution with water/formic acid (1%) and acetonitrile at a flow rate of 0.4 mL/min. Within 63 min, 36 peaks could be selected as the common peaks for fingerprint analysis to evaluate the similarities among several samples of XYLD tablets collected from different manufacturers. In quantitative analysis, seven compounds showed good regression (R > 0.9990) within test ranges and the recovery of the method was within the range of 95.9–104.3%. The method was successfully applied to the simultaneous determination of seven compounds in six batches of XYLD tablets. These results demonstrate that the combination of chromatographic fingerprint analysis and simultaneous multi‐ingredient quantification using the ultra high performance liquid chromatography method with diode array detection offers a rapid, efficient, and reliable approach for quality evaluation of XYLD tablets.  相似文献   

20.
Three columns packed with 2.0 μm superficially porous particles, 1.7 μm fully porous particles, and monodisperse 1.9 μm fully porous particles with narrow particle size distribution have been deeply characterized from a kinetic point of view. The 1.9 μm column showed excellent kinetic performance, comparable to that of the superficially porous one. These two columns also exhibit flatter c‐branches of the van Deemter curve compared to the 1.7 μm fully porous particles column, resulting in smaller loss of efficiency when they are operated at higher flow rates than the optimal ones. The independent evaluation of each contribution to band broadening has revealed that the difference in kinetic performance comes from the very small eddy dispersion contribution on the 1.9 μm column, surprisingly even lower than that of the superficially porous one. This finding suggests a very good packing of the monodisperse 1.9 μm column. On the other hand, the potential of 1.7 μm fully porous particles is completely broken down by the strong frictional heating effect already arising at relatively low flow rates.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号