首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple procedure was developed for the speciation of inorganic arsenic by electrochemical hydride generation atomic absorption spectrometry (EcHG–AAS), without pre-reduction of As(V). Glassy carbon was selected as cathode material in the flow cell. An optimum catholyte concentration for simultaneous generation of arsine from As(III) and As(V) was 0.06 mol l−1 H2SO4. Under the optimized conditions, adequate sensitivity and difference in ratio of slopes of the calibration curves for As(III) and As(V) can be achieved at the electrolytic currents of 0.6 and 1 A. The speciation of inorganic arsenic can be performed by controlling the electrolytic currents, and the concentration of As(III) and As(V) in the sample can be calculated according to the equations of absorbance additivity obtained at two selected electrolytic currents. The calibration curves were linear up to 50 ng ml−1 for both As(III) and As(V) at 0.6 and 1 A. The detection limits of the method were 0.2 and 0.5 ng ml−1 for As(III) and As(V) at 0.6 A, respectively. The relative standard deviations were of 2.1% for 20 ng ml−1 As(III) and 2.5% for 20 ng ml−1 As(V). The method was validated by the analysis of human hair certified reference material and successfully applied to speciation of soluble inorganic arsenic in Chinese medicine.  相似文献   

2.
A novel pervaporation-flow injection (PFI) system for the determination of As(III) in aqueous samples at μg l−1 level is described. The analytical procedure involved stopping the acceptor stream and injecting acidified As(III) samples into a 0.3 M HCl stream which was mixed with a 0.14 M sodium borohydride in 0.025 M NaOH stream. The arsine generated was transported in the pervaporation unit across a semi-permeable membrane (1.5 mm thickness) into the static acceptor solution containing 1.0×10−4 M KMnO4 in 0.1 M H2SO4 where it was oxidised. The acceptor stream was restarted after 6.5 min, and the decrease in permanganate absorbance at 528 nm was monitored to determine the initial concentration of As(III) in the samples. The method is characterised by a linear calibration range from 0.25 to 2000 μg l−1, a detection limit of 0.18 μg l−1 and a sampling frequency of 7 h−1. Samples containing As(V) were pre-treated with KI and HCl prior to injection to reduce As(V) to As(III). The effects of common anionic and cationic interferences, and the elimination of some metallic interferences using -cysteine are discussed. The method was applied to the analysis of environmental waters and the results were in good agreement with hydride generation atomic absorption spectrometric data.  相似文献   

3.
A new assay of nucleic acids at nanogram level was established based on the enhanced resonance light scattering (RLS) signals of two zwitterionics cocamidopropyl hydroxysultaine (HSB) and lauryl betaine (BS-12). Under optimum conditions, the weak RLS signal of HSB is enhanced by nucleic acids, and the enhanced RLS intensity is proportional to the concentration of nucleic acids in the range of 0.02–7.3 mg l−1 for calf thymus DNA and 0.01–8.6 mg l−1 for fish sperm DNA. The detection limits were 1.5 ng ml−1 for calf thymus DNA and 1.9 ng ml−1 for fish sperm DNA. Plasmid DNA extracted from K-12-HB101 colt was determined with satisfactory results.  相似文献   

4.
A new analytical procedure for the reliable and direct determination of arsenic (As) in nitric acid digests of ombrotrophic peat samples in the low ng l−1 range has been developed based on hydride generation-atomic absorption spectrometry (HG-AAS). The pre-reduction capabilities of KI/ascorbic acid and of l-cysteine in nitric acid digests of peat and plant samples for the conversion of As(V) to As(III) were tested systematically. Samples were digested with high purity nitric acid in a high-pressure microwave autoclave at 240 °C and subsequently measured using HG-AAS or ICP-SF-MS (inductively coupled plasma-sector field-mass spectrometry). Using KI/ascorbic acid as pre-reductant, the accuracy and precision were poor when digests of complex matrices, such as peat were analyzed for As by HG-AAS. However, 10 g l−1 l-cysteine was successfully employed as pre-reductant in diluted nitric acid digests (3%, v/v) of peat samples prior to hydride generation of As with 0.5% (m/v) of NaBH4 and 7 mol l−1 HCl. The analytical procedure was critically evaluated by analyzing several certified plant reference materials, two in-house peat reference materials and by the determination of As in diluted digests of peat samples with ICP-SF-MS. The results for the determination of As in various peat and plant materials showed excellent agreement with the reference values. The method detection limits for the determination of As by the optimized HG-AAS procedure and by ICP-SF-MS were 23 ng g−1 and 1.4 ng g−1 in solid peat, respectively. The newly developed analytical procedure was applied to the determination of As in selected peat samples. Results for As in these peat samples obtained by the developed HG-AAS procedure and the optimized procedure for the determination of As with ICP-SF-MS were highly correlated (R2 = 0.993, n = 12).  相似文献   

5.
Flow injection determination of nitrite by fluorescence quenching   总被引:2,自引:0,他引:2  
A simple, sensitive and selective fluorimetric method for the determination of nitrite ion in waters using a merging zones flow injection system is described. The fluorimetric determination is based on the measurement of the quenching effect produced by nitrite on proflavine (3,6-diaminoacridine) fluorescence (λexem=290/519 nm).

The optimum experimental conditions were investigated by merging 0.5 ml of the sample and 0.5 ml of a solution of 5 mg l−1 of proflavine (in 0.1 M HCl) in a flow injection system, on-line connected to a flow-cell placed in the conventional sample compartment of a spectrofluorimeter. The selected carrier solution and final flow rate were 0.1 M HCl and 0.5 ml min−1, respectively. A reaction coil of 2 ml was used. As a result of the simplicity of this system, a sample throughput of about 50 samples h−1 can be achieved with the proposed methodology.

The detection limit was 1.1 ng ml−1 (3σ criterion) of nitrite. The repeatability for five sample injections containing 100 ng ml−1 of nitrite was ±0.3% and the observed linear range extended up to 400 ng ml−1. Also, the effect of interferences from various metals and anions commonly present in waters was also studied.

The method was successfully applied to the determination of low levels of nitrite in different water samples (river, fountain, tap and commercial drinking waters).  相似文献   


6.
A HPLC method with automated column switching and UV-diode array detection is described for the simultaneous determination of Vitamin D3 and 25-hydroxyvitamin D3 (25-OH-D3) in a sample of human plasma. The system uses a BioTrap precolumn for the on-line sample cleanup. A sample of 1 ml of human plasma was treated with 2 ml of a mixture of ethanol–acetonitrile (2:1 (v/v)). Following centrifugation, the supernatant was evaporated to dryness under a stream of dry and pure nitrogen. The residue was reconstituted in 250 μL of a solution of methanol 5 mmol l−1 phosphate buffer, pH 6.5 (4:1 (v/v)), and a 200 μl aliquot of this solution was injected onto the BioTrap precolumn. After washing during 5 min with a mobile phase constituted by a solution of 6% acetonitrile in 5 mmol l−1 phosphate buffer, pH 6.5 (extraction mobile phase), the retained analytes were then transferred to the analytical column in the backflush mode. The analytical separation was then performed by reverse-phase chromatography in the gradient elution mode with the solvents A and B (Solvent A: acetonitrile–phosphate buffer 5 mmol l−1, pH 6.5; 20:80 (v/v); solvent B: methanol–acetonitrile–tetrahydrofuran, 65:20:15 (v/v)). The compounds of interest were detected at 265 nm. The method was linear in the range 3.0–32.0 ng ml−1 with a limit of quantification of 3.0 ng ml−1. Quantitative recoveries from spiked plasma samples were between 91.0 and 98.0%. In all cases, the coefficient of variation (CV) of the intra-day and inter-day-assay precision was ≤2.80%. The proposed method permitted the simultaneous determination of Vitamin D3 and 25-OH-D3 in 16 min, with an adequate precision and sensitivity. However, the overlap of the sample cleanup step with the analysis increases the sampling frequency to five samples h−1. The method was successfully applied for the determination of Vitamin D3 and 25-OH-D3 in plasma from 46 female volunteers, ranging from 50 to 94 years old. Vitamin D3 and 25-OH-D3 concentrations in plasma were found from 4.30–40.70 ng ml−1 (19.74 ± 9.48 ng ml−1) and 3.1–36.52 ng ml−1 (7.13 ± 7.80 ng ml−1), respectively. These results were in good agreement with data published by other authors.  相似文献   

7.
Leal LO  Semenova NV  Forteza R  Cerdà V 《Talanta》2004,64(5):1335-1342
A new multisyringe flow injection system for inorganic arsenic determination at trace levels by hydride generation-atomic fluorescence spectrometry (HGAFS) is presented. Preconcentration on a solid-phase was carried out using a column packed with an anion-exchange resin (Amberlite IRA-410). The reagents are dispensed to the system using a multisyringe burette coupled with two multi-port selection valves.

Different parameters were changing in order to make the system as effective as possible. An analytical curve was obtained for arsenic determination between 50 and 2000 ng l−1. This new approach improved five times the sensitivity over a MSFIA–HGAFS technique developed previously by the authors. Detection limit of the proposed technique was (3σb/S) of 30 ng l−1. The relative standard deviation (R.S.D.) of As at 1 μg l−1 was 4.8% (n=7). A sample throughput of 10 h−1 has been achieved. The proposed method has been applied to different reference solid and water materials with satisfactory results.  相似文献   


8.
Using zinc hexamethylenedithiocarbamate (Zn(HMDC)2) and flame atomic absorption spectrometry (FAAS) and/or flow injection hydride generation atomic absorption spectrometry (FI-HGAAS), solvent extraction of As(III) from HCl and H2SO4 media into 2,6-dimethyl-4-heptanone (diisobutyl ketone, DIBK) was examined. Arsenic(III) was quantitatively extracted with 2.41×10−3 mol l−1 Zn(HMDC)2 from about 0.004 (pH 2.4) to 4 mol l−1 HCl and H2SO4 aqueous solutions. The logarithmic conditional extraction constant of As(HMDC)3 in the HCl–DIBK system was determined to be 8.3±0.7, by the measurement of the distribution ratios of Zn(II) and As(III). The effectiveness of the proposed extraction method was ascertained in the determination of As in geochemical standard reference materials supplied by the Geological Survey of Japan. Furthermore, the analysis of arsenic in procedural blanks was 0.083±0.003 μg l−1.  相似文献   

9.
Li ZX  Guo YA 《Talanta》2005,65(5):1318-1325
A new and sample technique for the simultaneous determination of trace arsenic, antimony, bismuth and selenium in biologic samples by hydride generation-four-channel nondispersive atomic fluorescence spectrometry was development. The conditions of instrumentation and hydride generation of arsenic, antimony, bismuth and selenium were optimized. For reducing hexavalent Se to the tetravalent state was to heat the sample with 6 mol l−1 HCl, and then pre-reducing pentavalent As and Sb to the trivalent state was achieved by the addition of 0.05 mol l−1 thiourea. The interferences of coexisting ions were evaluated. Under optimal conditions, the detection limits for As, Sb, Bi and Se were determined to be 0.03, 0.04, 0.04 and 0.03 ng ml−1, respectively. The precision for seven replicate determinations at the 5 ng ml−1 of As, Sb, Bi and Se were 0.9, 1.2, 1.3 and 1.5% (R.S.D.), respectively. The proposed method was successfully applied to the simultaneous determination of As, Sb, Bi and Se in a series of Chinese certified biological reference materials using simple aqueous standard calibration technique, the results obtained are in good agreement with the certified values.  相似文献   

10.
A new po1y(acrylphenylamidrazone phenylhydrazide) chelating fiber is synthesized from polyacrylonitrile fiber and used for preconcentration and separation of trace Ga(III), In(III), Bi(III), V(V) and Ti(IV) from solution (5–50 ng ml−1 Ti(IV) or V(V) and 50–500 ng ml−1 Ga(III), In (III) or Bi(III) in 1000–100 ml of solution can be enriched quantitatively by 0.15 g of fiber at a 4 ml min−1 flow rate in the pH range 5–7 with recoveries >95%). These ions can be desorbed quantitatively with 20 ml of 4 M hydrochloric acid at 2 ml min−1 from the fiber column. When the fiber which had been treated with concentrated hydrochloric acid and washed with distilled water until neutral was reused eight times, the recoveries of the above ions by enrichment were still >95%. Two-hundred-fold to 10 000-fold excesses of Cu(II), Zn(II), Ca(II), Mn(II), Cr(III), Fe(III), Ba(II) and Al(III) caused little interference in the determination of these ions by inductively coupled plasma-atomic emission spectrometers (ICP-AES). The relative standard deviations for enrichment and determination of 50 ng ml−1 Ga, In or Bi and 10 ng ml−1 V or Ti are in the range 1.2–2.7%. The contents of these ions in real solution samples determined by this method were in agreement with the certified values of the samples with average errors <3.7%.  相似文献   

11.
Arancibia V  López A  Zúñiga MC  Segura R 《Talanta》2006,68(5):1567-1573
The separation of arsenic based on in situ chelation with ammonium diethyl dithiophosphate (ADDTP) has been carried out using methanol-modified supercritical CO2. Aliquots of extract were added to an electroanalytical cell and arsenic was determined by square wave cathodic stripping voltammetry (SWCSV) at a hanging mercury drop electrode (HMDE). Quantitative extractions of As(DDTP)3 were achieved when the experiments were carried out at a pressure of 2500 psi, a temperature of 90 °C, 2.0 mL of methanol, 20.0 min of static extraction and 5.0 min of dynamic extraction in the presence of 18 mg of ADDTP. Analysis of arsenic was made using 150 mg L−1 of Cu(II) in 1 M HCl solution as supporting electrolyte in the presence of ADDTP as ligand. Preconcentration was carried out by deposition at a potential of −0.50 V and the intermetallic compound CuxAsy was reduced at a potential of −0.77 to −0.82 V, depending on ligand concentration. The results showed that the presence of ligand plays an important role, increasing the method's sensitivity and preventing the oxidation of As(III). The calibration graph of the As(DDTP)3 solution was linear from 0.8 to 12.5 μg L−1 of arsenic (LOD 0.5 μg L−1, R = 0.9992, tacc = 60 s). The method was validated using carrot pulp spiked with arsenic solution. This method was applied to the determination of arsenic in samples of carrots, beets and irrigation water. Arsenic in beets was: skin 4.10 ± 0.18 mg kg−1; pulp 3.83 ± 0.19 mg kg−1 and juice 0.71 ± 0.09 mg L−1; arsenic in carrots was: skin 2.15 ± 0.09 mg kg−1; pulp 0.59 ± 0.11 mg kg−1 and juice 0.71 ± 0.03 mg L−1. Arsenic in water were: Chiu-Chiu 0.08 mg L−1, Inacaliri 1.12 mg L−1, and Salado river 0.17 ± 0.07 mg L−1.  相似文献   

12.
A reversed flow injection colorimetric procedure for determining iron(III) at the μg level was proposed. It is based on the reaction between iron(III) with norfloxacin (NRF) in 0.07 mol l−1 ammonium sulfate solution, resulting in an intense yellow complex with a suitable absorption at 435 nm. Optimum conditions for determining iron(III) were investigated by univariate method. The method involved injection of a 150 μl of 0.04% w/v colorimetric reagent solution into a merged streams of sample and/or standard solution containing iron(III) and 0.07 mol l−1 ammonium sulfate in sulfuric acid (pH 3.5) solution which was then passed through a single bead string reactor. Subsequently the absorbance as peak height was monitored at 435 nm. Beer's law obeyed over the range of 0.2–1.4 μg ml−1 iron(III). The method has been applied to the determination of total iron in water samples digested with HNO3–H2O2 (1:9 v/v). Detection limit (3σ) was 0.01 μg ml−1 the sample through of 86 h−1 and the coefficient of variation of 1.77% (n=12) for 1 μg ml−1 Fe(III) were achieved with the recovery of the spiked Fe(III) of 92.6–99.8%.  相似文献   

13.
Yun Fei Long  Cheng Zhi Huang   《Talanta》2007,71(5):1939-1943
The interaction of Amido black 10B (AB) with DNA in basic medium was studied in the presence of cetyltrimethylammonium bromide (CTMAB) based on the measurements of resonance light scattering (RLS), UV–vis, CD spectra, and RLS imaging. The interaction has been proved to give a ternary complex of CTMAB–DNA–AB in Britton–Robinson buffer of pH 11.55, which exhibits strong negative Cotton effect at 233.3 nm and 642.8 nm, and strong RLS signals characterized at 469 nm. Experiments showed that the enhanced RLS intensities (ΔIRLS) against the mixture of AB and CTMAB are proportional to the concentration of fish sperm DNA (fsDNA) and calf thymus DNA (ctDNA), respectively over the range of 0.03–1.0 and 0.05–1.5 μg ml−1, with the limits of determination (3σ) of 7.3 ng ml−1 for fsDNA and 7.0 ng ml−1 for ctDNA.  相似文献   

14.
Xiaohong Li  Yingying Su  Kailai Xu  Xiandeng Hou  Yi Lv   《Talanta》2007,72(5):1728-1732
A simple, sensitive and interference-free method was proposed for the determination of arsenic, based on the generation of volatile arsenic trichloride coupled with atomic fluorescence spectrometry. Thiourea, together with l-ascorbic acid, was used to reduce As(V) to As(III), and the chloride generation was based on the reaction between As(III) and hydrochloric acid. Under the optimized experimental conditions, the present procedure allows for the quantification of arsenic in the concentration range of 0.01–4.0 mg L−1, with a limit of detection (3σ) of 6.0 μg L−1. The relative standard deviation (R.S.D.) is 4.0% for 0.1 mg L−1 arsenic (n = 7). Finally, the proposed method was successfully applied to the determination of arsenic in several certified reference samples (stainless steel, alloy steel, copper alloy and water sample) and real samples (brass material and spiked cobalt material), with analytical results well-agreed with those by ICP-MS.  相似文献   

15.
A highly sensitive cathodic stripping voltammetric method for the determination of naringin is presented. It is based on the formation and accumulation of two naringin–mercury complexes at the electrode surface, followed by reduction of the surface species during a differential pulse voltammetric scan. The cathodic stripping responses at −0.25 V and −0.42 V, are evaluated with respect to various experimental conditions, such as composition and pH of the supporting electrolyte, naringin concentration, accumulation potential and preconcentration time. The new method is suitable for the determination of naringin concentrations between 0.1 mg l−1 (1.72×10−7 mol l−1) and 40 mg l−1 (6.88×10−5 mol l−1). A 3σ limit of detection of 32 μg l−1 (55 nmol l−1) can be reached. The relative standard deviation (r.s.d.) is <1.5%. Recovery experiments yielded a mean recovery of 97% (r.s.d.=4.1%). The application of the procedure to the selective determination of naringin in grapefruit juice is demonstrated.  相似文献   

16.
A sample solution was passed at 20 ml min−1 through a column (150×4 mm2) of Amberlite IRA-410Stron anion-exchange resin for 60 s. After washing, a solution of 0.1% sodium borohydride was passed through the column for 60 s at 5.1 ml min−1. Following a second wash, a solution of 8 mol l−1 hydrochloric acid was passed at 5.1 ml min−1 for 45 s. The hydrogen selenide was stripped from the eluent solution by the addition of an argon flow at 150 ml min−1 and the bulk phases were separated by a glass gas–liquid separator containing glass beads. The gas stream was dried by passing through a Nafion® dryer and fed, via a quartz capillary tube, into the dosing hole of a transversely heated graphite cuvette containing an integrated L’vov platform which had been pretreated with 120 μg of iridium as trapping agent. The furnace was held at a temperature of 250°C during this trapping stage and then stepped to 2000°C for atomization. The calibration was performed with aqueous standards solution of selenium (selenite, SeO32−) with quantification by peak area. A number of experimental parameters, including reagent flow rates and composition., nature of the gas–liquid separator, nature of the anion-exchange resin, column dimensions, argon flow rate and sample pH, were optimized. The effects of a number of possible interferents, both anionic and cationic were studies for a solution of 500 ng 1−1 of selenium. The most severe depressions were caused by iron (III) and mercury (II) for which concentrations of 20 and 10 mg  1−1 caused a 5% depression on the selenium signal. For the other cations (cadmium, cobalt, copper, lead,. magnesium, and nickel) concentrations of 50–70 mg 1−1 could be tolerated. Arsenate interfered at a concentration of 3 mg−1, whereas concentrations of chloride, bromide, iodide, perchlorate, and sulfate of 500–900 mg l−1 could be tolerated. A linear response was obtained between the detection limit of 4 ng 1−1, with a characteristic mass of 130 pg. The RSDs for solutions containing 100 and 200 ng 1−1 selenium were 2.3% and 1.5%, respectively.  相似文献   

17.
Bismuth as BiCl4 and BH4 ware successively retained in a column (150 mm × 4 mm, length × i.d.) packed with Amberlite IRA-410 (strong anion-exchange resin). This was followed by passage of an injected slug of hydrochloric acid resulting in bismuthine generation (BiH3). BiH3 was stripped from the eluent solution by the addition of a nitrogen flow and the bulk phases were separated in a gas–liquid separator. Finally, bismutine was atomized in a quartz tube for the subsequent detection of bismuth by atomic absorption spectrometry. Different halide complexes of bismuth (namely, BiBr4, BiI4 and BiCl4) were tested for its pre-concentration, being the chloride complexes which produced the best results. Therefore, a concentration of 0.3 mol l−1 of HCl was added to the samples and calibration solutions. A linear response was obtained between the detection limit (3σ) of 0.225 and 80 μg l−1. The R.S.D.% (n = 10) for a solution containing 50 μg l−1 of Bi was 0.85%. The tolerance of the system to interferences was evaluated by investigating the effect of the following ions: Cu2+, Co2+, Ni2+, Fe3+, Cd2+, Pb2+, Hg2+, Zn2+, and Mg2+. The most severe depression was caused by Hg2+, which at 60 mg l−1 caused a 5% depression on the signal. For the other cations, concentrations between 1000 and 10,000 mg l−1 could be tolerated. The system was applied to the determination of Bi in urine of patients under therapy with bismuth subcitrate. The recovery of spikes of 5 and 50 μg l−1 of Bi added to the samples prior to digestion with HNO3 and H2O2 was in satisfactory ranges from 95.0 to 101.0%. The concentrations of bismuth found in six selected samples using this procedure were in good agreement with those obtained by an alternative technique (ETAAS). Finally, the concentration of Bi determined in urine before and after 3 days of treatment were 1.94 ± 1.26 and 9.02 ± 5.82 μg l−1, respectively.  相似文献   

18.
This paper describes a method for the simultaneous determination of As(III), Sb(III) and Se(IV) by combining hydride generation and gas phase molecular absorption spectrometry. A system for continuous hydride generation has been designed and developed, based on the use of a double process of gas-liquid separation, and optimal compromise operation conditions for the three compounds have been found. After generation, the hydrides are collected in a liquid nitrogen cryogenic trap, and then evaporated and driven to the flow cell of a diode array spectrophotometer, in which the transient signals over the 190–250 nm wavelength interval are measured. Under the recommended conditions (sample flow: 35 ml min−1, 0.5 M HCl; reductor flow: 4 ml min−1 of 4% NaBH4, solution) linear response ranges above 50 μg 1−1 for As(III), 30 μg 1−1 for Sb(III) and 200 μg 1−1 for Se(IV) are obtained with detection limits of 22 μg 1−1, 15 μg 1−1 and 65 μg 1−1, respectively. Multiwavelength linear regression equations were used for the simultaneous determination of the three elements in different synthetic samples, with good precision and accuracy and to study simultaneously the interference from different chemical species for the three compounds. Results were similar to those obtained by other techniques using hydride generation.  相似文献   

19.
Development of an enzyme-linked immunosorbent assay for pentachlorophenol   总被引:5,自引:0,他引:5  
Pentachlorophenol (PCP) is a hazardous pollutant with toxicity and potential carcinogenic properties being a serious threat to the environment. In this work, the development of an immunoassay for PCP is presented. A hapten was synthesised and conjugated to protein for rabbit immunisation. Three polyclonal antibodies were obtained and the best results were achieved in the antibody-coated format using antiserum R3. Calibration range was 0.3–30.5 ng ml−1, with an average I50 value of 2.9 ng ml−1 and a detection limit of 0.1 ng ml−1. The specificity of the assay was tested against PCP structurally related compounds. The method is highly specific for PCP and shows low cross-reactivity (CR) for chlorine-containing phenols, nitrophenols, benzenic and piridinic compounds. The good recoveries achieved with different water samples indicate that this assay can be a good alternative method for the determination of PCP in this kind of samples.  相似文献   

20.
A novel, rapid and simple method by hydride generation-electrothermal atomic absorption spectrometry (HG-ETAAS) after direct As, Bi, Sb and Sn hydrides generation from untreated filters of atmospheric particulate matter (PM10 and PM2.5) was optimised. PM10 and PM2.5 were not subjected to any pre-treatment: circular portions between 0.28 and 6.28 cm2 were directly placed into the reaction vessel of a batch mode generation system. A 28 × 3/64 Plackett–Burman design was used as a multivariate strategy for the evaluation of the effects of several variables affecting the hydride generation, trapping and atomisation efficiencies. Trapping temperature was the most statistically significant variable for As, Bi and Sn. Atomisation temperature was also statistically significant for Sb determination. Optimum values of significant variables were selected by using univariate optimisation approaches. An aqueous calibration method was used throughout. The developed method has been found to be precise with relative standard deviations of 6.2, 5.3, 9.1 and 7.5% for 11 determinations in a filter sample containing 0.7, 1.0, 1.4 and 1.7 μg l−1 for As, Bi, Sb and Sn, respectively. Results obtained by direct solid sampling-HG-ETAAS have been found statistically comparable with those obtained after conventional method based on an acid digestion followed to ICP-MS. Absolute detection limits were 37, 15, 30, and 41 ng l−1 for As, Bi, Sb and Sn, respectively. Detection limits referred to the air volume sampled (in the range of 0.020–0.050 ng m−3) were low enough for the determination of several hydride-forming elements from PM10 and PM2.5 samples collected in a non-polluted suburban area of A Coruña (NW Spain).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号